Metal magnetic memory signals from surface of low-carbon steel and low-carbon alloyed steel 被引量:4
1
作者 董丽虹 徐滨士 +4 位作者 董世运 叶明慧 陈群志 王丹 尹大伟 《Journal of Central South University of Technology》 EI 2007年第1期24-27,共4页
In order to investigate the regularity of metal magnetic signals of ferromagnetic materials under the effect of applied load, the static tensile test of Q235 steel and 18CrNiWA steel plate specimens were conducted and... In order to investigate the regularity of metal magnetic signals of ferromagnetic materials under the effect of applied load, the static tensile test of Q235 steel and 18CrNiWA steel plate specimens were conducted and metal magnetic memory signals of specimens were measured during the test process. The influencing factors of metal magnetic memory signals and the relationship between axial applied load and signals were analyzed. The fracture and microstructure of the specimens were observed. The results show that the magnetic signals corresponding to the measured points change linearly approximately with increasing axial load. The microstructure of Q235 steel is ferrite and perlite, whereas that of 18CrNiWA steel is bainite and low-carbon martensite. The fracture of these two kinds of specimens is ductile rupture; carbon content of specimen materials and dislocation glide give much contribution to the characteristics of magnetic curves. 展开更多
关键词 metal magnetic memory low-carbon steel low-carbon alloyed steel applied load magnetic signals curve FRACTURE microstructure
下载PDF
Realization of Magnetic Signal Acquisition Scheme for Banknotes 被引量:1
2
作者 WANG Yang ZHANG Qinglin +1 位作者 CHEN Xi ZOU Lian 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2016年第4期344-350,共7页
In order to solve the problem of low signal-to-noise ratio(about 15 d B) in magnetic signal acquisition of banknotes, a new method of magnetic signal acquisition and processing is proposed taking RMB as an example. ... In order to solve the problem of low signal-to-noise ratio(about 15 d B) in magnetic signal acquisition of banknotes, a new method of magnetic signal acquisition and processing is proposed taking RMB as an example. In this method, weak signa detection is performed to reduce the noise accompanied with the signal. Seven orders of Chebyshev(Ⅰ) filter and the anti-jamming technology are used in the PCB layout, and grounding modes are introduced to reduce the noise of the amplitude waveform. The proposed method reduce the final output noise by 2/3 and the sig nal-to-noise ratio is increased to 24 d B. The experimental results show that the magnetic signal of RMB banknotes are acquired by the circuit stability, which provides an important guarantee for the improvements of the anti-counterfeit and discrimination for banknotes performance. 展开更多
关键词 magnetic signal electromagnetic interference weak signal detection seven orders of Chebyshev
原文传递
Unambiguously Resolving the Potential Neutrino Magnetic Moment Signal at Large Liquid Scintillator Detectors
3
作者 Ziping Ye Feiyang Zhang +1 位作者 Donglian Xu Jianglai Liu 《Chinese Physics Letters》 SCIE CAS CSCD 2021年第11期18-22,共5页
Non-vanishing electromagnetic properties of neutrinos have been predicted by many theories beyond the Standard Model, and an enhanced neutrino magnetic moment can have profound implications for fundamental physics. Th... Non-vanishing electromagnetic properties of neutrinos have been predicted by many theories beyond the Standard Model, and an enhanced neutrino magnetic moment can have profound implications for fundamental physics. The XENON1T experiment recently detected an excess of electron recoil events in the 1–7 keV energy range, which can be compatible with solar neutrino magnetic moment interaction at a most probable value of μ_(v) = 2.1 × 10^(-11)μ_(B).However, tritium backgrounds or solar axion interaction in this energy window are equally plausible causes.Upcoming multi-tonne noble liquid detectors will test these scenarios more in depth, but will continue to face similar ambiguity. We report a unique capability of future large liquid scintillator detectors to help resolve the potential neutrino magnetic moment scenario. With O(100) kton·year exposure of liquid scintillator to solar neutrinos, a sensitivity of μ_(v) < 10^(-11)μ_(B) can be reached at an energy threshold greater than 40 keV, where no tritium or solar axion events but only neutrino magnetic moment signal is still present. 展开更多
关键词 Unambiguously Resolving the Potential Neutrino magnetic Moment signal at Large Liquid Scintillator Detectors
下载PDF
A Classification Algorithm for Ground Moving Targets Based on Magnetic Sensors
4
作者 崔逊学 刘綦 刘坤 《Defence Technology(防务技术)》 SCIE EI CAS 2011年第1期52-58,共7页
A novel classification algorithm based on abnormal magnetic signals is proposed for ground moving targets which are made of ferromagnetic material. According to the effect of diverse targets on earth's magnetism,t... A novel classification algorithm based on abnormal magnetic signals is proposed for ground moving targets which are made of ferromagnetic material. According to the effect of diverse targets on earth's magnetism,the moving targets are detected by a magnetic sensor and classified with a simple computation method. The detection sensor is used for collecting a disturbance signal of earth magnetic field from an undetermined target. An optimum category match pattern of target signature is tested by training some statistical samples and designing a classification machine. Three ordinary targets are researched in the paper. The experimental results show that the algorithm has a low computation cost and a better sorting accuracy. This classification method can be applied to ground reconnaissance and target intrusion detection. 展开更多
关键词 information processing magnetic sensor abnormal magnetic signal target detection target classification classification algorithm
下载PDF
Mammography combined with breast dynamic contrast-enhanced-magnetic resonance imaging for the diagnosis of early breast cancer 被引量:4
5
作者 Yakun He Guohui Xu +4 位作者 Jin Ren Bin Feng Xiaolei Dong Hao Lu Changjiu He 《Oncology and Translational Medicine》 2016年第4期165-168,共4页
Objective The aim of this study was to investigate the application of mammography combined with breast dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) for the diagnosis of early breast cancer. Methods Ma... Objective The aim of this study was to investigate the application of mammography combined with breast dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) for the diagnosis of early breast cancer. Methods Mammography and DCE-MRI were performed for 120 patients with breast cancer(malignant, 102; benign; 18). Results The sensitivity of mammography for early diagnosis of breast cancer was 66.67%, specificity was 77.78%, and accuracy was 68.33%. The sensitivity of MRI for early diagnosis of breast cancer was 94.12%, specificity was 88.89%, and accuracy was 93.33%. However, the sensitivity of mammography combined with DCE-MRI volume imaging with enhanced water signal(VIEWS) scanning for early diagnosis of breast cancer was 97.06%, specificity was 94.44%, and accuracy was 96.67%. Conclusion Mammography combined with DCE-MRI increased the sensitivity, specificity, and accuracy of diagnosing early breast cancer. 展开更多
关键词 breast carcinoma mammography nuclear magnetic resonance dynamic enhancement time signal curve