期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Magnetic Field Curves and Magnetic Equipotential Surfaces around Crossing Electrical Wires Replacing Classical Magnetic Field Lines
1
作者 Geoffroy Auvert 《Open Journal of Applied Sciences》 2024年第8期1996-2008,共13页
This article is based on a recent model specifically defining magnetic field values around electrical wires. With this model, calculations of field around parallel wires were obtained. Now, this model is extended with... This article is based on a recent model specifically defining magnetic field values around electrical wires. With this model, calculations of field around parallel wires were obtained. Now, this model is extended with the new concept of magnetic equipotential surface to magnetic field curves around crossing wires. Cases of single, double, and triple wires are described. Subsequent article will be conducted for more general scenarios where wires are neither infinite nor parallel. 展开更多
关键词 magnetic Field value magnetic Field Vector magnetic Field Line magnetic Field Curve Equipotential Surface Crossing Electrical Wires magnetic Cross Product
下载PDF
Dynamic magnetic resonance defecography in 10 asymptomatic volunteers 被引量:7
2
作者 Andreas G Schreyer Christian Paetzel +7 位作者 Alois Fürst Lena M Dendl Elisabeth Hutzel René Müller-Wille Philipp Wiggermann Stephan Schleder Christian Stroszczynski Patrick Hoffstetter 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第46期6836-6842,共7页
AIM: Evaluation of the wide range of normal findings in asymptomatic women undergoing dynamic magnetic resonance (MR) defecography. METHODS: MR defecography of 10 healthy female volunteers (median age: 31 years) witho... AIM: Evaluation of the wide range of normal findings in asymptomatic women undergoing dynamic magnetic resonance (MR) defecography. METHODS: MR defecography of 10 healthy female volunteers (median age: 31 years) without previous pregnancies or history of surgery were evaluated. The rectum was filled with 180 mL gadolinium ultrasound gel mixture. MR defecography was performed in the supine position. The pelvic floor was visualized with a dynamic T2-weighted sagittal plane where all relevant pelvic floor organs were acquired during defecation. The volunteers were instructed to relax and then to perform straining maneuvers to empty the rectum. The pubococcygeal line (PCGL) was used as the line of reference. The movement of pelvic floor organs was measured as the vertical distance to this reference line. Data were recorded in the resting position as well as during the defecation process with maximal straining. Examinations were performed and evaluated by two experienced abdominal radiologists without knowledge of patient history. RESULTS: Average position of the anorectal junction was located at -5.3 mm at rest and -29.9 mm during straining. The anorectal angle widened significantly from 93° at rest to 109° during defecation. A rectocele was diagnosed in eight out of 10 volunteers showing an average diameter of 25.9 mm. The bladder base was located at a position of +23 mm at rest and descended to -8.1 mm during defecation in relation to the PCGL. The bladder base moved below the PCGL in six out of 10 volunteers, which was formally defined as a cystocele. The uterocervical junction was located at an average level of +43.1 mm at rest and at +7.9 mm during straining. The uterocervical junction of three volunteers fell below the PCGL; described formally as uterocervical prolapse. CONCLUSION: Based on the range of standard values in asymptomatic volunteers, MR defecography values for pathological changes have to be re-evaluated. 展开更多
关键词 magnetic resonance imaging Defecography Standard values
下载PDF
A 400 MHz Low Noise Amplifier at Cryogenic Temperature for Superconductor Filter System 被引量:3
3
作者 Guo-Bin Wang Xiao-Ping Zhang Bi-Song Cao 《Journal of Electronic Science and Technology of China》 2007年第3期230-233,共4页
A cryogenic low noise amplifier (LNA) using Agilent high electron mobility transistor (HEMT) for 380 MHzto 480 MHz is designed and fabricated, and the excellent cryogenic performance in superconducting receiver fr... A cryogenic low noise amplifier (LNA) using Agilent high electron mobility transistor (HEMT) for 380 MHzto 480 MHz is designed and fabricated, and the excellent cryogenic performance in superconducting receiver front-end for communication system is achieved. A special input impedance matching topology is implemented to provide low noise figure (NF) and good input matching in this cryogenic LNA design. The measurement results show that the NF is within 0.25 dB from the minimum NF of a single transistor, the power gain is above 20 dB, the flatness is within 1 dB, and the maximum input return loss is lower than -20 dB in bandwidth. 展开更多
关键词 Cryogenic low noise amplifier HTS fiter magnetic core inductor with high Q value superconductor receiver front-end.
下载PDF