期刊文献+
共找到542,425篇文章
< 1 2 250 >
每页显示 20 50 100
Production and test of sPHENIX W/SciFiber electromagnetic calorimeter blocks in China
1
作者 Xiao‑Zhou Yu Xi‑Yang Wang +11 位作者 Wei‑Hu Ma Shi‑Hong Fu Peng‑Fei Sun Jin‑Xing Song Wan‑Bing He Yang Shen Long Ma Jin‑Hui Chen Huan‑Zhong Huang Si‑Guang Wang Jing Zhou Xiao‑Mei Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第8期167-176,共10页
The sPHENIX experiment is a new generation of large acceptance detectors at the relativistic heavy ion collider at Brookhaven National Laboratory,with scientific goals focusing on probing the strongly interacting Quar... The sPHENIX experiment is a new generation of large acceptance detectors at the relativistic heavy ion collider at Brookhaven National Laboratory,with scientific goals focusing on probing the strongly interacting Quark–Gluon plasma with hard probes of jets,open heavy flavor particles,andγproduction.The EMCal detector,which covers the pseudo-rapidity region of|η|≤1.1,is an essential subsystem of sPHENIX.In this study,we focused on producing and testing EMCal blocks covering a pseudo-rapidity of|η|∈[0.8,1.1].These,in conjunction with the central pseudo-rapidity EMCal blocks,significantly enhance the sPHENIX physics capability of the jet andγparticle measurements.In this paper,the detector module production and testing of sPHENIX W-powder/scintillating fiber(W/ScFi)electromagnetic calorimeter blocks are presented.The selection of the tungsten powder,mold fabrication,QA procedures,and cosmic ray test results are discussed. 展开更多
关键词 sPHENIX Tungsten/scintillating fiber electromagnetic calorimeter Cosmic ray test
下载PDF
Estimation of unfrozen water content of saturated sandstones using nuclear magnetic resonance, mercury intrusion porosimetry, and ultrasonic tests
2
作者 Fei Liu Shibing Huang +1 位作者 Gang Liu Shilin Yu 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第9期3465-3484,共20页
The unfrozenwater content(UWC)is a crucial parameter that affects the strength and thermal properties of rocks in relation to engineering construction and geological disasters in cold regions.In this study,three diffe... The unfrozenwater content(UWC)is a crucial parameter that affects the strength and thermal properties of rocks in relation to engineering construction and geological disasters in cold regions.In this study,three different methods were employed to test and estimate the UWC of saturated sandstones,including nuclear magnetic resonance(NMR),mercury intrusion porosimetry(MIP),and ultrasonic methods.The NMR method enabled the direct measurement of the UWC of sandstones using the free induction decay(FID).The MIP method was used to analyze the pore structures of sandstones,with the UWC subsequently calculated based on pore ice crystallization.Therefore,the MIP test constituted an indirect measurement method.Furthermore,a correlation was established between the P-wave velocity and the UWC of these sandstones based on the mixture theory,which could be employed to estimate the UWC as an empirical method.All methods demonstrated that the UWC initially exhibited a rapid decrease from 0C to5C and then generally became constant beyond20C.However,these test methods had different characteristics.The NMR method was used to directly and accurately calculate the UWC in the laboratory.However,the cost and complexity of NMR equipment have precluded its use in the field.The UWC can be effectively estimated by the MIP test,but the estimation accuracy is influenced by the ice crystallization process and the pore size distribution.The P-wave velocity has been demonstrated to be a straightforward and practical empirical parameter and was utilized to estimate the UWC based on the mixture theory.This method may be more suitable in the field.All methods confirmed the existence of a hysteresis phenomenon in the freezing-thawing process.The average hysteresis coefficient was approximately 0.538,thus validating the GibbseThomson equation.This study not only presents alternative methodologies for estimating the UWC of saturated sandstones but also contribute to our understanding of the freezing-thawing process of pore water. 展开更多
关键词 Unfrozen water content(UWC) Nuclear magnetic resonance(NMR) Mercury intrusion porosimetry(MIP) Pore structures P-wave velocity SANDSTONE
下载PDF
Unveiling of Terahertz Emission from Ultrafast Demagnetization and the Anomalous Hall Effect in a Single Ferromagnetic Film 被引量:2
3
作者 蓝志强 李章顺 +4 位作者 徐浩然 刘凡 金钻明 彭滟 朱亦鸣 《Chinese Physics Letters》 SCIE EI CAS CSCD 2024年第4期45-50,共6页
Using THz emission spectroscopy,we investigate the elementary spin dynamics in ferromagnetic single-layer Fe on a sub-picosecond timescale.We demonstrate that THz radiation changes its polarity with reversal of the ma... Using THz emission spectroscopy,we investigate the elementary spin dynamics in ferromagnetic single-layer Fe on a sub-picosecond timescale.We demonstrate that THz radiation changes its polarity with reversal of the magnetization applied by the external magnetic field.In addition,it is found that the sign of THz polarity excited from different sides is defined by the thickness of the Fe layer and Fe/dielectric interface.Based on the thickness and symmetry dependences of THz emission,we experimentally distinguish between the two major contributions:ultrafast demagnetization and the anomalous Hall effect.Our experimental results not only enrich understanding of THz electromagnetic generation induced by femtosecond laser pulses but also provide a practical way to access laser-induced ultrafast spin dynamics in magnetic structures. 展开更多
关键词 magnetic magnetIZATION polarity
下载PDF
Research on the Testing Methods of Instrumental System in the Marine Magnetic Survey 被引量:1
4
作者 边刚 刘雁春 +2 位作者 于波 肖付民 卞光浪 《Marine Science Bulletin》 CAS 2007年第2期1-11,共11页
Testing methods of instrumental system in the marine magnetic survey have been studied in this paper, and the feasibility of each method has been testified by the observed data. The conclusion shows that the method br... Testing methods of instrumental system in the marine magnetic survey have been studied in this paper, and the feasibility of each method has been testified by the observed data. The conclusion shows that the method brought out can effectively eliminate the systematic error caused by the instrumental system, and greatly improve the surveying precision and the reliability of the survey results. 展开更多
关键词 Marine magnetic survey instrumental system testing method
下载PDF
Failure characterization of fully grouted rock bolts under triaxial testing 被引量:1
5
作者 Hadi Nourizadeh Ali Mirzaghorbanali +3 位作者 Mehdi Serati Elamin Mutaz Kevin McDougall Naj Aziz 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第3期778-789,共12页
Confining stresses serve as a pivotal determinant in shaping the behavior of grouted rock bolts.Nonetheless,prior investigations have oversimplified the three-dimensional stress state,primarily assuming hydrostatic st... Confining stresses serve as a pivotal determinant in shaping the behavior of grouted rock bolts.Nonetheless,prior investigations have oversimplified the three-dimensional stress state,primarily assuming hydrostatic stress conditions.Under these conditions,it is assumed that the intermediate principal stress(σ_(2))equals the minimum principal stress(σ_(3)).This assumption overlooks the potential variations in magnitudes of in situ stress conditions along all three directions near an underground opening where a rock bolt is installed.In this study,a series of push tests was meticulously conducted under triaxial conditions.These tests involved applying non-uniform confining stresses(σ_(2)≠σ_(3))to cubic specimens,aiming to unveil the previously overlooked influence of intermediate principal stresses on the strength properties of rock bolts.The results show that as the confining stresses increase from zero to higher levels,the pre-failure behavior changes from linear to nonlinear forms,resulting in an increase in initial stiffness from 2.08 kN/mm to 32.51 kN/mm.The load-displacement curves further illuminate distinct post-failure behavior at elevated levels of confining stresses,characterized by enhanced stiffness.Notably,the peak load capacity ranged from 27.9 kN to 46.5 kN as confining stresses advanced from σ_(2)=σ_(3)=0 to σ_(2)=20 MPa and σ_(3)=10 MPa.Additionally,the outcomes highlight an influence of confining stress on the lateral deformation of samples.Lower levels of confinement prompt overall dilation in lateral deformation,while higher confinements maintain a state of shrinkage.Furthermore,diverse failure modes have been identified,intricately tied to the arrangement of confining stresses.Lower confinements tend to induce a splitting mode of failure,whereas higher loads bring about a shift towards a pure interfacial shear-off and shear-crushed failure mechanism. 展开更多
关键词 Rock bolts Bolt-grout interface Bond strength Push test Triaxial tests
下载PDF
Contribution of glial cells to the neuroprotective effects triggered by repetitive magnetic stimulation:a systematic review 被引量:1
6
作者 Susana A.Ferreira Nuno Pinto +2 位作者 Inês Serrenho Maria Vaz Pato Graça Baltazar 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第1期116-123,共8页
Repetitive transcranial magnetic stimulation has been increasingly studied in different neurological diseases,and although most studies focus on its effects on neuronal cells,the contribution of nonneuronal cells to t... Repetitive transcranial magnetic stimulation has been increasingly studied in different neurological diseases,and although most studies focus on its effects on neuronal cells,the contribution of nonneuronal cells to the improvement trigge red by repetitive transcranial magnetic stimulation in these diseases has been increasingly suggested.To systematically review the effects of repetitive magnetic stimulation on non-neuronal cells two online databases.Web of Science and PubMed were searched fo r the effects of high-frequency-repetitive transcranial magnetic stimulation,low-frequencyrepetitive transcranial magnetic stimulation,intermittent theta-bu rst stimulation,continuous thetaburst stimulation,or repetitive magnetic stimulation on non-neuronal cells in models of disease and in unlesioned animals or cells.A total of 52 studies were included.The protocol more frequently used was high-frequency-repetitive magnetic stimulation,and in models of disease,most studies report that high-frequency-repetitive magnetic stimulation led to a decrease in astrocyte and mic roglial reactivity,a decrease in the release of pro-inflammatory cyto kines,and an increase of oligodendrocyte proliferation.The trend towards decreased microglial and astrocyte reactivity as well as increased oligodendrocyte proliferation occurred with intermittent theta-burst stimulation and continuous theta-burst stimulation.Few papers analyzed the low-frequency-repetitive transcranial magnetic stimulation protocol,and the parameters evaluated were restricted to the study of astrocyte reactivity and release of pro-inflammatory cytokines,repo rting the absence of effects on these paramete rs.In what concerns the use of magnetic stimulation in unlesioned animals or cells,most articles on all four types of stimulation reported a lack of effects.It is also important to point out that the studies were developed mostly in male rodents,not evaluating possible diffe rential effects of repetitive transcranial magnetic stimulation between sexes.This systematic review supports that thro ugh modulation of glial cells repetitive magnetic stimulation contributes to the neuroprotection or repair in various neurological disease models.Howeve r,it should be noted that there are still few articles focusing on the impact of repetitive magnetic stimulation on non-neuronal cells and most studies did not perform in-depth analyses of the effects,emphasizing the need for more studies in this field. 展开更多
关键词 ASTROCYTE GLIA high-frequency repetitive magnetic stimulation inflammation low-frequency repetitive magnetic stimulation MICROGLIA neurologic disorders OLIGODENDROCYTE repetitive magnetic stimulation theta-burst stimulation
下载PDF
Unbound^(28)O,the heaviest oxygen isotope observed:a cutting-edge probe for testing nuclear models 被引量:1
7
作者 Jian-Guo Li Bai-Shan Hu +1 位作者 Shuang Zhang Fu-Rong Xu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期1-2,共2页
The beyond-dripline oxygen isotopes^(27,28)O were recently observed at RIKEN,and were found to be unbound decaying into^(24)O by emitting neutrons.The unbound feature of the heaviest oxygen isotope,^(28)O,provides an ... The beyond-dripline oxygen isotopes^(27,28)O were recently observed at RIKEN,and were found to be unbound decaying into^(24)O by emitting neutrons.The unbound feature of the heaviest oxygen isotope,^(28)O,provides an excellent test for stateof-the-art nuclear models.The atomic nucleus is a self-organized quantum manybody system comprising specific numbers of protons Z and neutrons N. 展开更多
关键词 testing QUANTUM system
下载PDF
Laboratory observation of electron energy distribution near three-dimensional magnetic nulls 被引量:1
8
作者 何任川 徐田超 +7 位作者 杨肖易 肖池阶 张祖煜 袁瑞鑫 王晓钢 郭志彬 余修铭 盖跃 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期46-52,共7页
The acceleration of electrons near three-dimensional(3D)magnetic nulls is crucial to the energy conversion mechanism in the 3D magnetic reconnection process.To explore electron acceleration in a 3D magnetic null topol... The acceleration of electrons near three-dimensional(3D)magnetic nulls is crucial to the energy conversion mechanism in the 3D magnetic reconnection process.To explore electron acceleration in a 3D magnetic null topology,we constructed a pair of 3D magnetic nulls in the PKU Plasma Test(PPT)device and observed acceleration of electrons near magnetic nulls.This study measured the plasma floating potential and ion density profiles around the 3D magnetic null.The potential wells near nulls may be related to the energy variations of electrons,so we measured the electron distribution functions(EDFs)at different spatial positions.The axial variation of EDF shows that the electrons deviate from the Maxwell distribution near magnetic nulls.With scanning probes that can directionally measure and theoretically analyze based on curve fitting,the variations of EDFs are linked to the changes of plasma potential under 3D magnetic null topology.The kinetic energy of electrons accelerated by the electric field is 6 eV(v_(e)~7v_(Alfvén-e))and the scale of the region where accelerating electrons exist is in the order of serval electron skin depths. 展开更多
关键词 electron acceleration EEDF 3D magnetic null magnetic reconnection
下载PDF
Toward understanding the microstructure characteristics,phase selection and magnetic properties of laser additive manufactured Nd-Fe-B permanent magnets 被引量:1
9
作者 Bo Yao Nan Kang +6 位作者 Xiangyu Li Dou Li Mohamed EL Mansori Jing Chen Haiou Yang Hua Tan Xin Lin 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2024年第1期277-294,共18页
Nd-Fe-B permanent magnets play a crucial role in energy conversion and electronic devices.The essential magnetic properties of Nd-Fe-B magnets,particularly coercivity and remanent magnetization,are significantly infue... Nd-Fe-B permanent magnets play a crucial role in energy conversion and electronic devices.The essential magnetic properties of Nd-Fe-B magnets,particularly coercivity and remanent magnetization,are significantly infuenced by the phase characteristics and microstructure.In this work,Nd-Fe-B magnets were manufactured using vacuum induction melting(VIM),laser directed energy deposition(LDED)and laser powder bed fusion(LPBF)technologies.Themicrostructure evolution and phase selection of Nd-Fe-B magnets were then clarified in detail.The results indicated that the solidification velocity(V)and cooling rate(R)are key factors in the phase selection.In terms of the VIM-casting Nd-Fe-B magnet,a large volume fraction of theα-Fe soft magnetic phase(39.7 vol.%)and Nd2Fe17Bxmetastable phase(34.7 vol.%)areformed due to the low R(2.3×10-1?C s-1),whereas only a minor fraction of the Nd2Fe14B hard magnetic phase(5.15 vol.%)is presented.For the LDED-processed Nd-Fe-B deposit,although the Nd2Fe14B hard magnetic phase also had a low value(3.4 vol.%)as the values of V(<10-2m s-1)and R(5.06×103?C s-1)increased,part of theα-Fe soft magnetic phase(31.7vol.%)is suppressed,and a higher volume of Nd2Fe17Bxmetastable phases(47.5 vol.%)areformed.As a result,both the VIM-casting and LDED-processed Nd-Fe-B deposits exhibited poor magnetic properties.In contrast,employing the high values of V(>10-2m s-1)and R(1.45×106?C s-1)in the LPBF process resulted in the substantial formation of the Nd2Fe14B hard magnetic phase(55.8 vol.%)directly from the liquid,while theα-Fe soft magnetic phase and Nd2Fe17Bxmetastable phase precipitation are suppressed in the LPBF-processed Nd-Fe-B magnet.Additionally,crystallographic texture analysis reveals that the LPBF-processedNd-Fe-B magnets exhibit isotropic magnetic characteristics.Consequently,the LPBF-processed Nd-Fe-B deposit,exhibiting a coercivity of 656 k A m-1,remanence of 0.79 T and maximum energy product of 71.5 k J m-3,achieved an acceptable magnetic performance,comparable to other additive manufacturing processed Nd-Fe-B magnets from MQP(Nd-lean)Nd-Fe-Bpowder. 展开更多
关键词 laser additive manufacturing(LAM) Nd-Fe-B permanent magnets numerical simulation microstructure magnetic properties
下载PDF
Staging liver fibrosis with various diffusion-weighted magnetic resonance imaging models 被引量:1
10
作者 Yan-Li Jiang Juan Li +6 位作者 Peng-Fei Zhang Feng-Xian Fan Jie Zou Pin Yang Peng-Fei Wang Shao-Yu Wang Jing Zhang 《World Journal of Gastroenterology》 SCIE CAS 2024年第9期1164-1176,共13页
BACKGROUND Diffusion-weighted imaging(DWI)has been developed to stage liver fibrosis.However,its diagnostic performance is inconsistent among studies.Therefore,it is worth studying the diagnostic value of various diff... BACKGROUND Diffusion-weighted imaging(DWI)has been developed to stage liver fibrosis.However,its diagnostic performance is inconsistent among studies.Therefore,it is worth studying the diagnostic value of various diffusion models for liver fibrosis in one cohort.AIM To evaluate the clinical potential of six diffusion-weighted models in liver fibrosis staging and compare their diagnostic performances.METHODS This prospective study enrolled 59 patients suspected of liver disease and scheduled for liver biopsy and 17 healthy participants.All participants underwent multi-b value DWI.The main DWI-derived parameters included Mono-apparent diffusion coefficient(ADC)from mono-exponential DWI,intravoxel incoherent motion model-derived true diffusion coefficient(IVIM-D),diffusion kurtosis imaging-derived apparent diffusivity(DKI-MD),stretched exponential model-derived distributed diffusion coefficient(SEM-DDC),fractional order calculus(FROC)model-derived diffusion coefficient(FROC-D)and FROC model-derived microstructural quantity(FROC-μ),and continuous-time random-walk(CTRW)model-derived anomalous diffusion coefficient(CTRW-D)and CTRW model-derived temporal diffusion heterogeneity index(CTRW-α).The correlations between DWI-derived parameters and fibrosis stages and the parameters’diagnostic efficacy in detecting significant fibrosis(SF)were assessed and compared.RESULTS CTRW-D(r=-0.356),CTRW-α(r=-0.297),DKI-MD(r=-0.297),FROC-D(r=-0.350),FROC-μ(r=-0.321),IVIM-D(r=-0.251),Mono-ADC(r=-0.362),and SEM-DDC(r=-0.263)were significantly correlated with fibrosis stages.The areas under the ROC curves(AUCs)of the combined index of the six models for distinguishing SF(0.697-0.747)were higher than each of the parameters alone(0.524-0.719).The DWI models’ability to detect SF was similar.The combined index of CTRW model parameters had the highest AUC(0.747).CONCLUSION The DWI models were similarly valuable in distinguishing SF in patients with liver disease.The combined index of CTRW parameters had the highest AUC. 展开更多
关键词 Liver fibrosis magnetic resonance imaging Diffusion-weighted magnetic resonance Liver biopsy Significant fibrosis
下载PDF
Preoperative prediction of perineural invasion of rectal cancer based on a magnetic resonance imaging radiomics model:A dual-center study 被引量:2
11
作者 Yan Liu Bai-Jin-Tao Sun +3 位作者 Chuan Zhang Bing Li Xiao-Xuan Yu Yong Du 《World Journal of Gastroenterology》 SCIE CAS 2024年第16期2233-2248,共16页
BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for indivi... BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for individualized treatment of RC.Recently,several radiomics studies have been used to predict the PNI status in RC,demonstrating a good predictive effect,but the results lacked generalizability.The preoperative prediction of PNI status is still challenging and needs further study.AIM To establish and validate an optimal radiomics model for predicting PNI status preoperatively in RC patients.METHODS This retrospective study enrolled 244 postoperative patients with pathologically confirmed RC from two independent centers.The patients underwent preoperative high-resolution magnetic resonance imaging(MRI)between May 2019 and August 2022.Quantitative radiomics features were extracted and selected from oblique axial T2-weighted imaging(T2WI)and contrast-enhanced T1WI(T1CE)sequences.The radiomics signatures were constructed using logistic regression analysis and the predictive potential of various sequences was compared(T2WI,T1CE and T2WI+T1CE fusion sequences).A clinical-radiomics(CR)model was established by combining the radiomics features and clinical risk factors.The internal and external validation groups were used to validate the proposed models.The area under the receiver operating characteristic curve(AUC),DeLong test,net reclassification improvement(NRI),integrated discrimination improvement(IDI),calibration curve,and decision curve analysis(DCA)were used to evaluate the model performance.RESULTS Among the radiomics models,the T2WI+T1CE fusion sequences model showed the best predictive performance,in the training and internal validation groups,the AUCs of the fusion sequence model were 0.839[95%confidence interval(CI):0.757-0.921]and 0.787(95%CI:0.650-0.923),which were higher than those of the T2WI and T1CE sequence models.The CR model constructed by combining clinical risk factors had the best predictive performance.In the training and internal and external validation groups,the AUCs of the CR model were 0.889(95%CI:0.824-0.954),0.889(95%CI:0.803-0.976)and 0.894(95%CI:0.814-0.974).Delong test,NRI,and IDI showed that the CR model had significant differences from other models(P<0.05).Calibration curves demonstrated good agreement,and DCA revealed significant benefits of the CR model.CONCLUSION The CR model based on preoperative MRI radiomics features and clinical risk factors can preoperatively predict the PNI status of RC noninvasively,which facilitates individualized treatment of RC patients. 展开更多
关键词 Rectal cancer Perineural invasion magnetic resonance imaging Radiomics NOMOGRAM
下载PDF
Electrochemical biosensors for point-of-care testing 被引量:1
12
作者 Jinsol Kim Juho Jeong Seung Hwan Ko 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第4期548-565,共18页
Point-of-care testing(POCT)is the practice of diagnosing and monitoring diseases where the patient is located,as opposed to traditional treatment conducted solely in a medical laboratory or other clinical setting.POCT... Point-of-care testing(POCT)is the practice of diagnosing and monitoring diseases where the patient is located,as opposed to traditional treatment conducted solely in a medical laboratory or other clinical setting.POCT has been less common in the recent past due to a lack of portable medical devices capable of facilitating effective medical testing.However,recent growth has occurred in this field due to advances in diagnostic technologies,device miniaturization,and progress in wearable electronics.Among these developments,electrochemical sensors have attracted interest in the POCT field due to their high sensitivity,compact size,and affordability.They are used in various applications,from disease diagnosis to health status monitoring.In this paper we explore recent advancements in electrochemical sensors,the methods of fabricating them,and the various types of sensing mechanisms that can be used.Furthermore,we delve into methods for immobilizing specific biorecognition elements,including enzymes,antibodies,and aptamers,onto electrode surfaces and how these sensors are used in real-world POCT settings. 展开更多
关键词 Point-of-care testing(POCT) Electrochemical sensor ENZYME ANTIBODY Health care
下载PDF
Simulation of the SMILE Soft X-ray Imager response to a southward interplanetary magnetic field turning 被引量:1
13
作者 Andrey Samsonov Graziella Branduardi-Raymont +3 位作者 Steven Sembay Andrew Read David Sibeck Lutz Rastaetter 《Earth and Planetary Physics》 EI CSCD 2024年第1期39-46,共8页
The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magne... The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magnetic field turning and produce SXI count maps with a 5-minute integration time.By making assumptions about the magnetopause shape,we find the magnetopause standoff distance from the count maps and compare it with the one obtained directly from the magnetohydrodynamic(MHD)simulation.The root mean square deviations between the reconstructed and MHD standoff distances do not exceed 0.2 RE(Earth radius)and the maximal difference equals 0.24 RE during the 25-minute interval around the southward turning. 展开更多
关键词 magnetOPAUSE magnetic reconnection solar wind charge exchange southward interplanetary magnetic field numerical modeling Solar wind magnetosphere Ionosphere Link Explorer(SMILE) Soft X-ray Imager
下载PDF
Numerical Analysis of the Magnetic Dipole Effect on a Radiative Ferromagnetic Liquid Flowing over a Porous Stretched Sheet 被引量:1
14
作者 G.Dharmaiah F.Mebarek-Oudina +1 位作者 K.S.Balamurugan N.Vedavathi 《Fluid Dynamics & Materials Processing》 EI 2024年第2期293-310,共18页
The effects of a magnetic dipole on a nonlinear thermally radiative ferromagnetic liquidflowing over a stretched surface in the presence of Brownian motion and thermophoresis are investigated.By means of a similarity t... The effects of a magnetic dipole on a nonlinear thermally radiative ferromagnetic liquidflowing over a stretched surface in the presence of Brownian motion and thermophoresis are investigated.By means of a similarity transformation,ordinary differential equations are derived and solved afterwards using a numerical(the BVP4C)method.The impact of various parameters,namely the velocity,temperature,concentration,is presented graphically.It is shown that the nanoparticles properties,in conjunction with the magnetic dipole effect,can increase the thermal conductivity of the engineered nanofluid and,consequently,the heat transfer.Comparison with earlier studies indicates high accuracy and effectiveness of the numerical approach.An increase in the Brow-nian motion parameter and thermophoresis parameter enhances the concentration and the related boundary layer.The skin-friction rises when the viscosity parameter is increased.A larger value of the ferromagnetic para-meter results in a higher skin-friction and,vice versa,in a smaller Nusselt number. 展开更多
关键词 Brownian motion thermo-phoresis radiation magnetic dipole BVP4C NON-LINEAR
下载PDF
Magnetic resonance imaging of extraocular rectus muscles abnormalities in acute acquired concomitant esotropia 被引量:1
15
作者 Jia-Yu Chen Li-Rong Zhang +5 位作者 Jia-Wen Liu Jie Hao Hui-Xin Li Qiong-Yue Zhang Zhao-Hui Liu Jing Fu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期119-125,共7页
AIM:To investigate the difference of medial rectus(MR)and lateral rectus(LR)between acute acquired concomitant esotropia(AACE)and the healthy controls(HCs)detected by magnetic resonance imaging(MRI).METHODS:A case-con... AIM:To investigate the difference of medial rectus(MR)and lateral rectus(LR)between acute acquired concomitant esotropia(AACE)and the healthy controls(HCs)detected by magnetic resonance imaging(MRI).METHODS:A case-control study.Eighteen subjects with AACE and eighteen HCs were enrolled.MRI scanning data were conducted in target-controlled central gaze with a 3-Tesla magnetic resonance scanner.Extraocular muscles(EOMs)were scanned in contiguous image planes 2-mm thick spanning the EOM origins to the globe equator.To form posterior partial volumes(PPVs),the LR and MR cross-sections in the image planes 8,10,12,and 14 mm posterior to the globe were summed and multiplied by the 2-mm slice thickness.The data were classified according to the right eye,left eye,dominant eye,and non-dominant eye,and the differences in mean cross-sectional area,maximum cross-sectional area,and PPVs of the MR and LR muscle in the AACE group and HCs group were compared under the above classifications respectively.RESULTS:There were no significant differences between the two groups of demographic characteristics.The mean cross-sectional area of the LR muscle was significantly greater in the AACE group than that in the HCs group in the non-dominant eyes(P=0.028).The maximum cross-sectional area of the LR muscle both in the dominant and non-dominant eye of the AACE group was significantly greater than the HCs group(P=0.009,P=0.016).For the dominant eye,the PPVs of the LR muscle were significantly greater in the AACE than that in the HCs group(P=0.013),but not in the MR muscle(P=0.698).CONCLUSION:The size and volume of muscles dominant eyes of AACE subjects change significantly to overcome binocular diplopia.The LR muscle become larger to compensate for the enhanced convergence in the AACE. 展开更多
关键词 acute acquired concomitant esotropia magnetic resonance imaging extraocular muscles
下载PDF
Semi-analytical investigation of heat transfer in a porous convective radiative moving longitudinal fin exposed to magnetic field in the presence of a shape-dependent trihybrid nanofluid 被引量:1
16
作者 C.G.PAVITHRA B.J.GIREESHA M.L.KEERTHI 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第1期197-216,共20页
The thermal examination of a non-integer-ordered mobile fin with a magnetism in the presence of a trihybrid nanofluid(Fe_3O_4-Au-Zn-blood) is carried out. Three types of nanoparticles, each having a different shape, a... The thermal examination of a non-integer-ordered mobile fin with a magnetism in the presence of a trihybrid nanofluid(Fe_3O_4-Au-Zn-blood) is carried out. Three types of nanoparticles, each having a different shape, are considered. These shapes include spherical(Fe_3O_4), cylindrical(Au), and platelet(Zn) configurations. The combination approach is utilized to evaluate the physical and thermal characteristics of the trihybrid and hybrid nanofluids, excluding the thermal conductivity and dynamic viscosity. These two properties are inferred by means of the interpolation method based on the volume fraction of nanoparticles. The governing equation is transformed into a dimensionless form, and the Adomian decomposition Sumudu transform method(ADSTM) is adopted to solve the conundrum of a moving fin immersed in a trihybrid nanofluid. The obtained results agree well with those numerical simulation results, indicating that this research is reliable. The influence of diverse factors on the thermal overview for varying noninteger values of γ is analyzed and presented in graphical representations. Furthermore, the fluctuations in the heat transfer concerning the pertinent parameters are studied. The results show that the heat flux in the presence of the combination of spherical, cylindrical, and platelet nanoparticles is higher than that in the presence of the combination of only spherical and cylindrical nanoparticles. The temperature at the fin tip increases by 0.705 759% when the value of the Peclet number increases by 400%, while decreases by 11.825 13% when the value of the Hartman number increases by 400%. 展开更多
关键词 convection radiation moving longitudinal fin Adomian decomposition Sumudu transform method(ADSTM) trihybrid nanofluid magnetic field
下载PDF
High-grade pancreatic intraepithelial neoplasia diagnosed based on changes in magnetic resonance cholangiopancreatography findings:A case report 被引量:2
17
作者 Nao Furuya Atsushi Yamaguchi +13 位作者 Naohiro Kato Syuhei Sugata Takuro Hamada Takeshi Mizumoto Yuzuru Tamaru Ryusaku Kusunoki Toshio Kuwai Hirotaka Kouno Kazuya Kuraoka Yoshiyuki Shibata Sho Tazuma Takeshi Sudo Hiroshi Kohno Shiro Oka 《World Journal of Clinical Cases》 SCIE 2024年第8期1487-1496,共10页
BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most ... BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most previous cases were diagnosed based on findings of a focal stricture of the main pancreatic duct(MPD)and caudal MPD dilatation and subsequent pancreatic juice cytology using endoscopic retrograde cholangiopancreatography(ERCP).We experienced a case of high-grade PanIN with an unclear MPD over a 20-mm range,but without caudal MPD dilatation on magnetic resonance cholangiopancreatography(MRCP).CASE SUMMARY A 60-year-old female patient underwent computed tomography for a follow-up of uterine cancer post-excision,which revealed pancreatic cysts.MRCP revealed an unclear MPD of the pancreatic body at a 20-mm length without caudal MPD dilatation.Thus,course observation was performed.After 24 mo,MRCP revealed an increased caudal MPD caliber and a larger pancreatic cyst.We performed ERCP and detected atypical cells suspected of adenocarcinoma by serial pancreatic juice aspiration cytology examination.We performed a distal pancreatectomy and obtained a histopathological diagnosis of high-grade PanIN.Pancreatic parenchyma invasion was not observed,and curative resection was achieved.CONCLUSION High-grade Pan-IN may cause MPD narrowing in a long range without caudal MPD dilatation. 展开更多
关键词 Pancreatic cancer Pancreatic intraepithelial neoplasm High-grade pancreatic intraepithelial neoplasm magnetic resonance cholangiopancreatography Carcinoma in situ Case report
下载PDF
Helicobacter pylori infection may result in poor gastric cleanliness in magnetically controlled capsule gastroscopy examination: A singlecenter retrospective study
18
作者 Jingjing Xia Jie Fang +2 位作者 Liying Chen Yange Meng Lin Su 《Laparoscopic, Endoscopic and Robotic Surgery》 2024年第4期147-154,共8页
Objective:Magnetically controlled capsule gastroscopy(MCCG)is an effective method for screening gastric diseases;however,its performance may be affected by gastric cleanliness.We aimed to explore the correlation betwe... Objective:Magnetically controlled capsule gastroscopy(MCCG)is an effective method for screening gastric diseases;however,its performance may be affected by gastric cleanliness.We aimed to explore the correlation between Helicobacter pylori infection and the degree of gastric cleanliness in the MCCG.Methods:This retrospective study enrolled 297 participants from October 2020 to April 2024 at Sir Run Run Shaw Hospital,Zhejiang University School of Medicine.Participant characteristics,MCCG examination results,and(13)C-urea breath test(C13-UBT)results were collected.The gastric cleanliness in MCCG examinations was assessed using a gastric cleanliness score.Binary logistic regression was used to analyze the relationships among participant characteristics,H.pylori infection,and gastric cleanliness.Chi-square tests and Fisher's exact tests were used to analyze the relationships among gastric lesions,H.pylori infection,and gastric cleanliness.Results:Among the participants,24.2%had H.pylori infection,and 17.5%had poor gastric cleanliness.Hypertension(odds ratio[OR]:2.63;95%confidence interval[CI]:1.36e5.09;p?0.004)was associated with a greater likelihood of H.pylori infection.H.pylori infection(OR:3.76;95%CI:1.99e7.09;p<0.001)was an independent risk factor for poor gastric cleanliness in the MCCG.A significant disparity was noted in the prevalence of focal erosions(p<0.001),gastric ulcers(p?0.001),and positive gastric lesions(p?0.027)between the 2 groups with and without H.pylori infection.The proportion of positive gastric lesions was not significantly different between the good gastric cleanliness group and the poor gastric cleanliness group(25.7%vs.21.2%;p?0.490).Conclusion:The findings of this study revealed that H.pylori infection was associated with hypertension.H.pylori infection may lead to poor gastric cleanliness.Institutions are advised to perform C13-UBT before MCCG,and participants should be informed of the risk of poor gastric cleanliness if the results are positive.The decision to perform H.pylori eradication before MCCG should take into account patient willingness and the benefit-to-risk ratio. 展开更多
关键词 Helicobacter pylori Gastric cleanliness C-urea breath test Hypertension magnetically controlled capsule gastroscopy
下载PDF
Outcomes and efficacy of magnetic resonance imaging-compatible sacral nerve stimulator for management of fecal incontinence: A multi-institutional study 被引量:1
19
作者 Binit Katuwal Amy Thorsen +5 位作者 Kunal Kochar Ryba Bhullar Ray King Ernesto Raul Drelichman Vijay K Mittal Jasneet Singh Bhullar 《World Journal of Radiology》 2024年第2期32-39,共8页
BACKGROUND Fecal incontinence(FI)is an involuntary passage of fecal matter which can have a significant impact on a patient’s quality of life.Many modalities of treatment exist for FI.Sacral nerve stimulation is a we... BACKGROUND Fecal incontinence(FI)is an involuntary passage of fecal matter which can have a significant impact on a patient’s quality of life.Many modalities of treatment exist for FI.Sacral nerve stimulation is a well-established treatment for FI.Given the increased need of magnetic resonance imaging(MRI)for diagnostics,the In-terStim which was previously used in sacral nerve stimulation was limited by MRI incompatibility.Medtronic MRI-compatible InterStim was approved by the United States Food and Drug Administration in August 2020 and has been widely used.AIM To evaluate the efficacy,outcomes and complications of the MRI-compatible InterStim.METHODS Data of patients who underwent MRI-compatible Medtronic InterStim placement at UPMC Williamsport,University of Minnesota,Advocate Lutheran General Hospital,and University of Wisconsin-Madison was pooled and analyzed.Patient demographics,clinical features,surgical techniques,complications,and outcomes were analyzed.Strengthening the Reporting of Observational studies in Epidemiology(STROBE)cross-sectional reporting guidelines were used.RESULTS Seventy-three patients had the InterStim implanted.The mean age was 63.29±12.2 years.Fifty-seven(78.1%)patients were females and forty-two(57.5%)patients had diabetes.In addition to incontinence,overlapping symptoms included diarrhea(23.3%),fecal urgency(58.9%),and urinary incontinence(28.8%).Fifteen(20.5%)patients underwent Peripheral Nerve Evaluation before proceeding to definite implant placement.Thirty-two(43.8%)patients underwent rechargeable InterStim placement.Three(4.1%)patients needed removal of the implant.Migration of the external lead connection was observed in 7(9.6%)patients after the stage I procedure.The explanation for one patient was due to infection.Seven(9.6%)patients had other complications like nerve pain,hematoma,infection,lead fracture,and bleeding.The mean follow-up was 6.62±3.5 mo.Sixty-eight(93.2%)patients reported significant improvement of symptoms on follow-up evaluation.CONCLUSION This study shows promising results with significant symptom improvement,good efficacy and good patient outcomes with low complication rates while using MRI compatible InterStim for FI.Further long-term follow-up and future studies with a larger patient population is recommended. 展开更多
关键词 Fecal incontinence Sacral nerve stimulation InterStim magnetic resonance imaging Sacral neuromodulation
下载PDF
Potential applications of 7 Tesla magnetic resonance imaging in paediatric neuroimaging:Feasibility and challenges 被引量:1
20
作者 Arosh S Perera Molligoda Arachchige Letterio S Politi 《World Journal of Clinical Pediatrics》 2024年第2期1-6,共6页
The integration of 7 Tesla magnetic resonance imaging(7 T MRI)in adult patients has marked a revolutionary stride in radiology.In this article we explore the feasibility of 7 T MRI in paediatric practice,emphasizing i... The integration of 7 Tesla magnetic resonance imaging(7 T MRI)in adult patients has marked a revolutionary stride in radiology.In this article we explore the feasibility of 7 T MRI in paediatric practice,emphasizing its feasibility,applications,challenges,and safety considerations.The heightened resolution and tissue contrast of 7 T MRI offer unprecedented diagnostic accuracy,particularly in neuroimaging.Applications range from neuro-oncology to neonatal brain imaging,showcasing its efficacy in detecting subtle structural abnormalities and providing enhanced insights into neurological conditions.Despite the promise,challenges such as high cost,discomfort,and safety concerns necessitate careful consideration.Research suggests that,with precautions,7 T MRI is feasible in paediatrics,yet ongoing studies and safety assessments are imperative. 展开更多
关键词 7 Tesla magnetic resonance imaging Pediatric imaging FEASIBILITY CHALLENGES
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部