A new sliding mode controller for semi-active suspension system with magnetorheological (MR) damper is presented in this paper. In the proposed sliding mode controller, a semi-active suspension based on the skyhook da...A new sliding mode controller for semi-active suspension system with magnetorheological (MR) damper is presented in this paper. In the proposed sliding mode controller, a semi-active suspension based on the skyhook damper system is chosen as the reference model to be followed, and the control law is so determined that the asymptotically stable error dynamics occurs between the controlled state and the reference model state. Numerical simulations are carried out to study the performance of the new sliding mode controller. The results show that the proposed controller yields almost perfect tracking to the reference model and has a high robustness against model parameter uncertainties and disturbances.展开更多
The control strategy is very important for semiactive control or active control systems. An integrated intelligent control strategy for building structures incorpo rated with magnetorheological (MR) dampers subjected ...The control strategy is very important for semiactive control or active control systems. An integrated intelligent control strategy for building structures incorpo rated with magnetorheological (MR) dampers subjected to earthquake excitation is proposed. In this strategy, the time-delay problem is solved by a neural network and the control currents of the MR dampers are determined quickly by a fuzzy controller. Through a numerical example of a three-storey structure with one MR damper installed in the first floor, the seismic responses of the uncontrolled, the intelligently controlled, the passiveon controlled, and the passive-off controlled structures under different earthquake excitations are analyzed. Based on the numerical results, it can be found that the time domain and the frequency domain responses are reduced effectively when the MR damper is added in the structure, and the integrated intelligent control strategy has a better earthquake mitigation effect.展开更多
The recently proposed mega-sub controlled structure (MSCS), a new type of structure associated with the design and construction of super-tall buildings, has attracted the attention of designers for use in enhancing ...The recently proposed mega-sub controlled structure (MSCS), a new type of structure associated with the design and construction of super-tall buildings, has attracted the attention of designers for use in enhancing the control effectiveness in mega-frame buildings. In this paper, a dynamic equation and method to assemble parameter matrixes for a mega-sub controlled structure under random wind loads is presented. Semi-active control using magnetorheological dampers for the MSCS under random wind loads is investigated, and is compared with a corresponding system without dampers. A parametric study of the relative stiffness ratio and relative mass ratio between the mega-frame and the substructures, as well as the additional column stiffness ratio that influences the response control effectiveness of the MSCS, is discussed. The studies reveal, for the first time, that different control mechanisms exist. The results indicate that the proposed structure employing semi-active control can offer an effective control mechanism. Guidelines for selecting parameters are provided based on the analytical study.展开更多
In the field of civil engineering, magnetorheological fluid (MRF) damper-based semi-active control systems have received considerable attention for use in protecting structures from natural hazards such as strong ea...In the field of civil engineering, magnetorheological fluid (MRF) damper-based semi-active control systems have received considerable attention for use in protecting structures from natural hazards such as strong earthquakes and high winds. In this paper, the MRF damper-based semi-active control system is applied to a long-span spatially extended structure and its feasibility is discussed. Meanwhile, a _trust-region method based instantaneous optimal semi-active control algorithm (TIOC) is proposed to improve the performance of the semi-active control system in a multiple damper situation. The proposed TIOC describes the control process as a bounded constraint optimization problem, in which an optimal semi- active control force vector is solved by the trust-region method in every control step to minimize the structural responses. A numerical example of a railway station roof structure installed with MRF-04K dampers is presented. First, a modified Bouc- Wen model is utilized to describe the behavior of the selected MRF-04K damper. Then, two semi-active control systems, including the well-known clipped-optimal controller and the proposed TIOC controller, are considered. Based on the characteristics of the long-span spatially extended structure, the performance of the control system is evaluated under uniform earthquake excitation and travelling-wave excitation with different apparent velocities. The simulation results indicate that the MR fluid damper-based semi-active control systems have the potential to mitigate the responses of full-scale long-span spatially extended structures under earthquake hazards. The superiority of the proposed TIOC controller is demonstrated by comparing its control effectiveness with the clipped-optimal controller for several different cases.展开更多
Theoretical and practical issues concerning the multi-faceted task of mitigating the latero-torsional seismic response of a prototypal frame structure with asymmetric mass distribution are approached, Chevron braces w...Theoretical and practical issues concerning the multi-faceted task of mitigating the latero-torsional seismic response of a prototypal frame structure with asymmetric mass distribution are approached, Chevron braces with embedded magnetorheological dampers acting on the interstory drift are used to ensure additional energy dissipation. The semi-active control strategy employed to govern the modification of the damper characteristics via feedback is based on the selection of optimal forces according to a H2/LQG criterion, with respect to which the actual forces are regulated by a clipped-optimal logic. A dynamic observer is used to estimate the state through a non-collocated placement of the acceleration sensors. Several aspects to be addressed throughout the complex process including the design, modelization, and implementation phases of semi-active protection systems are discussed. Finally, experimental results obtained to mitigate the motion induced by ground excitation in a large-scale laboratory prototype, simulating the seismic response of a two-story building, are summarized.展开更多
To effectively reduce the damage to people and devices in civil defense engineering subjected to blast shock, a blast shock isolation system with magnetorheological fluid dampers (MRFD) is proposed. MRFD can provide c...To effectively reduce the damage to people and devices in civil defense engineering subjected to blast shock, a blast shock isolation system with magnetorheological fluid dampers (MRFD) is proposed. MRFD can provide continuously adjustable Coulomb friction and has many advantages for semi-active control. Numerical simulation of this isolation system is finished using Matlab simulink toolbox. General semi-active control algorithms are consided based on instantaneous optimal active control algorithm. And the results indicate that the shock isolation system can work efficiently, decreasing about 93% of the peak acceleration of the isolation floor.展开更多
A semi-active strategy for model predictive control (MPC), in which magneto-rheological dampers are used as an actuator, is presented for use in reducing the nonlinear seismic response of high-rise buildings. A mult...A semi-active strategy for model predictive control (MPC), in which magneto-rheological dampers are used as an actuator, is presented for use in reducing the nonlinear seismic response of high-rise buildings. A multi-step predictive model is developed to estimate the seismic performance of high-rise buildings, taking into account of the effects of nonlinearity, time-variability, model mismatching, and disturbances and uncertainty of controlled system parameters by the predicted error feedback in the multi-step predictive model. Based on the predictive model, a Kalman-Bucy observer suitable for semi-active strategy is proposed to estimate the state vector from the acceleration and semi-active control force feedback. The main advantage of the proposed strategy is its inherent stability, simplicity, on-line real-time operation, and the ability to handle nonlinearity, uncertainty, and time-variability properties of structures. Numerical simulation of the nonlinear seismic responses of a controlled 20-story benchmark building is carried out, and the simulation results are compared to those of other control systems. The results show that the developed semi-active strategy can efficiently reduce the nonlinear seismic response of high-rise buildings.展开更多
The theoretical study of a semi-active predictive control(SAPC) system with magnetorheological(MR) dampers to reduce the responses of seismically excited structures was presented.The SAPC scheme is based on a predicti...The theoretical study of a semi-active predictive control(SAPC) system with magnetorheological(MR) dampers to reduce the responses of seismically excited structures was presented.The SAPC scheme is based on a prediction model of the system response to obtain the control actions by minimizing an object function,which has a function of self-compensation for time delay occurring in real application.A double-ended shear mode combined with a valve mode MR damper,named MRF-04K damper,with the maximum force of 20 kN was designed and manufactured,and parameters of the Bouc-Wen hysteresis model were determined to portray the behavior of this damper.As an example,a 5-story building frame equipped with 2 MRF-04K dampers was presented to demonstrate the performance of the proposed SAPC scheme for addressing time delay and reducing the structural responses under different earthquakes.Comparison with the uncontrolled structure,the passive-off and passive-on cases indicates that both the peak and the norm values of structural responses are all clearly reduced,and the SAPC scheme has a better performance than the two passive cases.展开更多
Magnetorheological (MR) dampers have been proposed to control the vibration of offshore platforms in this paper. The semi-active control strategy based on fuzzy control algorithm was adopted to determine the optimal...Magnetorheological (MR) dampers have been proposed to control the vibration of offshore platforms in this paper. The semi-active control strategy based on fuzzy control algorithm was adopted to determine the optimal output control force based on the responses of jacket platforms. A typical jacket platform in Mexico Gulf was selected as the numerical example to investigate the effectiveness of the proposed control method. Furthermore, a model experiment was performed to validate the results of the numerical simulation. The experimental model of the jacket platform was designed based on dynamical similarity criterion by the scale of 1:50. Both of the numerical and experimental results show that the semi-active control system with the MR damper can reduce vibrations of jacket platforms effectively and at the same time the control effect is stable.展开更多
Vertical mass isolation(VMI)is one of the novel methods for the seismic control of structures.In this method,the entire structure is assumed to consist of two mass and stiffness subsystems,and an isolated layer is loc...Vertical mass isolation(VMI)is one of the novel methods for the seismic control of structures.In this method,the entire structure is assumed to consist of two mass and stiffness subsystems,and an isolated layer is located among them.In this study,the magnetorheological damper in three modes:passive-off,passive-on,and semi-active mode with variable voltage between zero and 9 volts was used as an isolated layer between two subsystems.Multi-degrees-of-freedom structures with 5,10,and 15 floors in two dimensions were examined under 11 pairs of near field earthquakes.On each level,the displacement of MR dampers was taken into account.The responses of maximum displacement,maximum inter-story drift,and maximum base shear in controlled and uncontrolled buildings were compared to assess the suggested approach for seismic control of the structures.According to the results,the semi-active control method can reduce the response by more than 12%compared to the uncontrolled mode in terms of maximum displacement of the mass subsystem of the structures.This method can reduce more than 16%and 20%of the responses compared to the uncontrolled mode in terms of maximum inter-story drift and base shear of the structure,respectively.展开更多
Due to the high viscosity of magnetorheological(MR)fluid,eliminating air pockets dissolved in the fluid is very difficult,which results in a force lag phenomenon.In order to evaluate the performance of a semi-active c...Due to the high viscosity of magnetorheological(MR)fluid,eliminating air pockets dissolved in the fluid is very difficult,which results in a force lag phenomenon.In order to evaluate the performance of a semi-active control system based on the MR damper considering the trapped air effect,a performance test on a MR damper is carried out under different loading cases,and the influence of the input current,excitation amplitude and frequency on the force lag phenomenon is analyzed.A concise and efficient parametric model,combining the simple Bouc-Wen model and a spring with small stiffness,is proposed to portray the experimental characteristics of the MR damper with force lag,and then the response analysis of the semi-active controlled single-degree-of-freedom(SDOF)structure is performed using the classic clipped-optimal control strategy based on acceleration feedback.Numerical results show that the trapped air in the MR fluid can weaken the control effect of the MR damper,and the performance of the semi-active control system will be reduced more obviously and become close to the passive-off control with the increasing content of air trapped in the MR fluid.展开更多
基金the Nature Science Foundation of China (No: 51035030) and the Applied and Basic Research Foundation of Chongqing University.
文摘A new sliding mode controller for semi-active suspension system with magnetorheological (MR) damper is presented in this paper. In the proposed sliding mode controller, a semi-active suspension based on the skyhook damper system is chosen as the reference model to be followed, and the control law is so determined that the asymptotically stable error dynamics occurs between the controlled state and the reference model state. Numerical simulations are carried out to study the performance of the new sliding mode controller. The results show that the proposed controller yields almost perfect tracking to the reference model and has a high robustness against model parameter uncertainties and disturbances.
基金the National Natural Science Foundation of China(Grant No.50508010),the Program for New Century Excellent in the Education Ministry of China,the Program for Jiangsu Province 333 Talents and the Scientific Research Foundation for the Returned Overseas Chinese Scholars,Education Ministry.of China
文摘The control strategy is very important for semiactive control or active control systems. An integrated intelligent control strategy for building structures incorpo rated with magnetorheological (MR) dampers subjected to earthquake excitation is proposed. In this strategy, the time-delay problem is solved by a neural network and the control currents of the MR dampers are determined quickly by a fuzzy controller. Through a numerical example of a three-storey structure with one MR damper installed in the first floor, the seismic responses of the uncontrolled, the intelligently controlled, the passiveon controlled, and the passive-off controlled structures under different earthquake excitations are analyzed. Based on the numerical results, it can be found that the time domain and the frequency domain responses are reduced effectively when the MR damper is added in the structure, and the integrated intelligent control strategy has a better earthquake mitigation effect.
基金Science and Technology Fund of NWPU Under Grant No. M450211Seed Fund of NWPU Under Grant No. Z200534
文摘The recently proposed mega-sub controlled structure (MSCS), a new type of structure associated with the design and construction of super-tall buildings, has attracted the attention of designers for use in enhancing the control effectiveness in mega-frame buildings. In this paper, a dynamic equation and method to assemble parameter matrixes for a mega-sub controlled structure under random wind loads is presented. Semi-active control using magnetorheological dampers for the MSCS under random wind loads is investigated, and is compared with a corresponding system without dampers. A parametric study of the relative stiffness ratio and relative mass ratio between the mega-frame and the substructures, as well as the additional column stiffness ratio that influences the response control effectiveness of the MSCS, is discussed. The studies reveal, for the first time, that different control mechanisms exist. The results indicate that the proposed structure employing semi-active control can offer an effective control mechanism. Guidelines for selecting parameters are provided based on the analytical study.
基金Supported by:National Science Fund for Distinguished Young Scholars of China Under Grant No. 50425824the National Natural Science Foundation of China Under Grant No.50578109,90715034 and 90715032
文摘In the field of civil engineering, magnetorheological fluid (MRF) damper-based semi-active control systems have received considerable attention for use in protecting structures from natural hazards such as strong earthquakes and high winds. In this paper, the MRF damper-based semi-active control system is applied to a long-span spatially extended structure and its feasibility is discussed. Meanwhile, a _trust-region method based instantaneous optimal semi-active control algorithm (TIOC) is proposed to improve the performance of the semi-active control system in a multiple damper situation. The proposed TIOC describes the control process as a bounded constraint optimization problem, in which an optimal semi- active control force vector is solved by the trust-region method in every control step to minimize the structural responses. A numerical example of a railway station roof structure installed with MRF-04K dampers is presented. First, a modified Bouc- Wen model is utilized to describe the behavior of the selected MRF-04K damper. Then, two semi-active control systems, including the well-known clipped-optimal controller and the proposed TIOC controller, are considered. Based on the characteristics of the long-span spatially extended structure, the performance of the control system is evaluated under uniform earthquake excitation and travelling-wave excitation with different apparent velocities. The simulation results indicate that the MR fluid damper-based semi-active control systems have the potential to mitigate the responses of full-scale long-span spatially extended structures under earthquake hazards. The superiority of the proposed TIOC controller is demonstrated by comparing its control effectiveness with the clipped-optimal controller for several different cases.
基金Project DPC-ReLUIS 2005-2008, RL n.7 "Technologies for the isolation and control of structures and infrastructures"
文摘Theoretical and practical issues concerning the multi-faceted task of mitigating the latero-torsional seismic response of a prototypal frame structure with asymmetric mass distribution are approached, Chevron braces with embedded magnetorheological dampers acting on the interstory drift are used to ensure additional energy dissipation. The semi-active control strategy employed to govern the modification of the damper characteristics via feedback is based on the selection of optimal forces according to a H2/LQG criterion, with respect to which the actual forces are regulated by a clipped-optimal logic. A dynamic observer is used to estimate the state through a non-collocated placement of the acceleration sensors. Several aspects to be addressed throughout the complex process including the design, modelization, and implementation phases of semi-active protection systems are discussed. Finally, experimental results obtained to mitigate the motion induced by ground excitation in a large-scale laboratory prototype, simulating the seismic response of a two-story building, are summarized.
基金Supported by the National Civil Defense Office of China for the Tenth Five-Year Plan and Tsinghua Basic Research Foundation (No.JC2003001)
文摘To effectively reduce the damage to people and devices in civil defense engineering subjected to blast shock, a blast shock isolation system with magnetorheological fluid dampers (MRFD) is proposed. MRFD can provide continuously adjustable Coulomb friction and has many advantages for semi-active control. Numerical simulation of this isolation system is finished using Matlab simulink toolbox. General semi-active control algorithms are consided based on instantaneous optimal active control algorithm. And the results indicate that the shock isolation system can work efficiently, decreasing about 93% of the peak acceleration of the isolation floor.
基金Fujian Province Youth Foundation for InnovativResearch Under Grant No. 2006F3008Fujian ProvincEducational Special Foundation Under Grant No. JA06027
文摘A semi-active strategy for model predictive control (MPC), in which magneto-rheological dampers are used as an actuator, is presented for use in reducing the nonlinear seismic response of high-rise buildings. A multi-step predictive model is developed to estimate the seismic performance of high-rise buildings, taking into account of the effects of nonlinearity, time-variability, model mismatching, and disturbances and uncertainty of controlled system parameters by the predicted error feedback in the multi-step predictive model. Based on the predictive model, a Kalman-Bucy observer suitable for semi-active strategy is proposed to estimate the state vector from the acceleration and semi-active control force feedback. The main advantage of the proposed strategy is its inherent stability, simplicity, on-line real-time operation, and the ability to handle nonlinearity, uncertainty, and time-variability properties of structures. Numerical simulation of the nonlinear seismic responses of a controlled 20-story benchmark building is carried out, and the simulation results are compared to those of other control systems. The results show that the developed semi-active strategy can efficiently reduce the nonlinear seismic response of high-rise buildings.
基金Projects(90815025,51178034) supported by the National Natural Science Foundation of China
文摘The theoretical study of a semi-active predictive control(SAPC) system with magnetorheological(MR) dampers to reduce the responses of seismically excited structures was presented.The SAPC scheme is based on a prediction model of the system response to obtain the control actions by minimizing an object function,which has a function of self-compensation for time delay occurring in real application.A double-ended shear mode combined with a valve mode MR damper,named MRF-04K damper,with the maximum force of 20 kN was designed and manufactured,and parameters of the Bouc-Wen hysteresis model were determined to portray the behavior of this damper.As an example,a 5-story building frame equipped with 2 MRF-04K dampers was presented to demonstrate the performance of the proposed SAPC scheme for addressing time delay and reducing the structural responses under different earthquakes.Comparison with the uncontrolled structure,the passive-off and passive-on cases indicates that both the peak and the norm values of structural responses are all clearly reduced,and the SAPC scheme has a better performance than the two passive cases.
基金Supported by the National Natural Science Foundation of China (NSFC-5060900).
文摘Magnetorheological (MR) dampers have been proposed to control the vibration of offshore platforms in this paper. The semi-active control strategy based on fuzzy control algorithm was adopted to determine the optimal output control force based on the responses of jacket platforms. A typical jacket platform in Mexico Gulf was selected as the numerical example to investigate the effectiveness of the proposed control method. Furthermore, a model experiment was performed to validate the results of the numerical simulation. The experimental model of the jacket platform was designed based on dynamical similarity criterion by the scale of 1:50. Both of the numerical and experimental results show that the semi-active control system with the MR damper can reduce vibrations of jacket platforms effectively and at the same time the control effect is stable.
文摘Vertical mass isolation(VMI)is one of the novel methods for the seismic control of structures.In this method,the entire structure is assumed to consist of two mass and stiffness subsystems,and an isolated layer is located among them.In this study,the magnetorheological damper in three modes:passive-off,passive-on,and semi-active mode with variable voltage between zero and 9 volts was used as an isolated layer between two subsystems.Multi-degrees-of-freedom structures with 5,10,and 15 floors in two dimensions were examined under 11 pairs of near field earthquakes.On each level,the displacement of MR dampers was taken into account.The responses of maximum displacement,maximum inter-story drift,and maximum base shear in controlled and uncontrolled buildings were compared to assess the suggested approach for seismic control of the structures.According to the results,the semi-active control method can reduce the response by more than 12%compared to the uncontrolled mode in terms of maximum displacement of the mass subsystem of the structures.This method can reduce more than 16%and 20%of the responses compared to the uncontrolled mode in terms of maximum inter-story drift and base shear of the structure,respectively.
基金The National Science Fund for Distinguished Young Scholars(No.51625803)China and Korea International Cooperation Project of the National Key Research and Development Program(No.2016YEE0119700)+3 种基金the Fundamental Research Funds for the Central Universities(No.3205008102)the Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions(No.CE02-2-33)Research and Innovation Project for College Graduates of Jiangsu Province(No.KYLX15_0088,KYLX16_0255)the State Foundation for Studying Abroad,China
文摘Due to the high viscosity of magnetorheological(MR)fluid,eliminating air pockets dissolved in the fluid is very difficult,which results in a force lag phenomenon.In order to evaluate the performance of a semi-active control system based on the MR damper considering the trapped air effect,a performance test on a MR damper is carried out under different loading cases,and the influence of the input current,excitation amplitude and frequency on the force lag phenomenon is analyzed.A concise and efficient parametric model,combining the simple Bouc-Wen model and a spring with small stiffness,is proposed to portray the experimental characteristics of the MR damper with force lag,and then the response analysis of the semi-active controlled single-degree-of-freedom(SDOF)structure is performed using the classic clipped-optimal control strategy based on acceleration feedback.Numerical results show that the trapped air in the MR fluid can weaken the control effect of the MR damper,and the performance of the semi-active control system will be reduced more obviously and become close to the passive-off control with the increasing content of air trapped in the MR fluid.