期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Simplified Calculation of Flow Resistance of Suspension Bridge Main Cable Dehumidification System
1
作者 Zhiyuan Tu Fusheng Peng +3 位作者 Zijie Wei Guo Qian Jie Wang Chunjie Huang 《Fluid Dynamics & Materials Processing》 EI 2021年第6期1195-1211,共17页
To calculate the flow resistance of a main cable dehumidification system,this study considers the air flow in the main cable as the flow in a porous medium,and adopts the Hagen–Poiseuille equation by using average hy... To calculate the flow resistance of a main cable dehumidification system,this study considers the air flow in the main cable as the flow in a porous medium,and adopts the Hagen–Poiseuille equation by using average hydraulic radius and capillary bundle models.A mathematical derivation is combined with an experimental study to obtain a semi-empirical flow resistance formula.Additionally,Fluent software is used to simulate the flow resistance across the main cable relative to the experimental values.Based on the actual measured results for a Yangtze River bridge,this study verifies the semi-empirical formula,and indicates that it can be applied in actual engineering. 展开更多
关键词 main cable dehumidification computational fluid dynamics dry air semi-empirical flow resistance formula
下载PDF
Tribo-corrosion interaction of the parallel steel wires in the suspension bridges
2
作者 Bo WANG Dagang WANG +3 位作者 Hailang CHONG Guozheng XIE Dekun ZHANG Shirong GE 《Friction》 SCIE EI CAS CSCD 2023年第12期2221-2237,共17页
The effect of contact load and relative displacement on tribo-corrosion interaction of parallel steel wires of main cable in the suspension bridge was investigated in this study.A self-made tribo-corrosion test bench ... The effect of contact load and relative displacement on tribo-corrosion interaction of parallel steel wires of main cable in the suspension bridge was investigated in this study.A self-made tribo-corrosion test bench was employed to conduct tribo-corrosion tests of parallel steel wires in 3.5%(wt%)NaCl solution and deionized water under different contact loads and different relative displacements.The friction coefficient and wear coefficient of wires were presented.Electrochemical corrosion behavior(Tafel polarization curves,Nyquist diagram,and equivalent circuit diagram)was characterized by electrochemical analyzer.Wear morphology was observed by scanning electron microscope.Wear volume loss and corrosion‒wear interaction were quantitatively demonstrated by high-precision weighing balance.The results show that the electrochemical corrosion ability of the steel wires increases with the increase of the contact load or relative displacement.The increased contact load or relative displacement increases the volume loss of corrosion‒wear and pure wear,but decreases the wear coefficient.The wear mechanisms in 3.5%NaCl solution are adhesive wear,abrasive wear,and corrosive wear as compared to adhesive wear and abrasive wear in deionized water under different contact loads.The wear mechanisms of parallel steel wires are slightly different under different relative displacements.But the main wear mechanisms are similar to that under different contact loads.The interaction effects of corrosion and wear produced by the contact load and relative displacement are all the synergistic effects. 展开更多
关键词 main cable parallel steel wires FRICTION corrosion‒wear INTERACTION
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部