Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportio...Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportional integral derivative (PID) control scheme. For the characteristics of the main steam pressure in coal-fired power plant boiler, the sliding mode control system with Smith predictive structure is proposed to look for performance and robustness improvement. First, internal model control (IMC) and Smith predictor (SP) is used to deal with the time delay, and sliding mode controller (SMCr) is designed to overcome the model mismatch. Simulation results show the effectiveness of the proposed controller compared with conventional ones.展开更多
The thermodynamic(energy and exergy)analysis of a condensate heating system,its segments,and components from a marine steam propulsion plant with steam reheating is performed in this paper.It is found that energy anal...The thermodynamic(energy and exergy)analysis of a condensate heating system,its segments,and components from a marine steam propulsion plant with steam reheating is performed in this paper.It is found that energy analysis of any condensate heating system should be avoided because it is highly influenced by the measuring equipment accuracy and precision.All the components from the observed marine condensate heating system have energy destructions lower than 3 kW,while the energy efficiencies of this system are higher than 99%.The exergy efficiency of closed condensate heaters continuously increases from the lowest to the highest steam pressures(from 70.10%to 92.29%).The ambient temperature variation between 5℃and 45℃notably influences the exergy efficiency change of both low pressure heaters and the low pressure segment equal to 31.61%,12.37%,and 18.35%,respectively.展开更多
The mechanic properties, lasting strength and microstructural properties of straight and elbow pipesof 12CrMo, 10CrMo910 and 12CrlMoV low alloy steel main steam piping system after long-time service weretested and stu...The mechanic properties, lasting strength and microstructural properties of straight and elbow pipesof 12CrMo, 10CrMo910 and 12CrlMoV low alloy steel main steam piping system after long-time service weretested and studied. The testing results showed that, for straight and elbow pipes of mainsteam piping under theconditions of high temperature and high pressure, the numerical operating performance indexes of their metalchanged with little difference, generally both within 5%, and the Values of elbow were higher than those ofstraight pipes. These phenomena proved that the aging processes of pipe metal at different positions are thesame. And the cause for higher numerical performance indexes of elbow and higher failure rate at elbow posi-tion during operation of steam pipes were investigated.展开更多
Ultra-supercritical(USC) unit is more and more popular in coal-fired power industry.In this paper,closed-loop identification based on subspace model identification(SMI) is introduced for superheated steam temperature ...Ultra-supercritical(USC) unit is more and more popular in coal-fired power industry.In this paper,closed-loop identification based on subspace model identification(SMI) is introduced for superheated steam temperature system of USC unit.Closed-loop SMI is applied to building step response model of the unit directly.The parameters selection method is proposed to deal with the parameter sensitivity and improve the reliability of the model.Finally,the model is used in model identification of real USC unit.展开更多
基金Supported by the National Natural Science Foundation of China (61174059, 60934007, 61233004)the National Basic Research Program of China (2013CB035406)Shanghai Rising-Star Tracking Program (11QH1401300)
文摘Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportional integral derivative (PID) control scheme. For the characteristics of the main steam pressure in coal-fired power plant boiler, the sliding mode control system with Smith predictive structure is proposed to look for performance and robustness improvement. First, internal model control (IMC) and Smith predictor (SP) is used to deal with the time delay, and sliding mode controller (SMCr) is designed to overcome the model mismatch. Simulation results show the effectiveness of the proposed controller compared with conventional ones.
基金This research is supported by the Croatian Science Foundation under the project IP-2018-01-3739,CEEPUS network CIII-HR-0108,European Regional Development Fund under the grant KK.01.1.1.01.0009(DATACROSS)project CEKOM under the grant KK.01.2.2.03.0004,CEI project“COVIDAi”(305.6019-20)University of Rijeka Scientific Grants uniri-tehnic-18-275-1447,uniritehnic-18-18-1146 and uniri-tehnic-18-14.
文摘The thermodynamic(energy and exergy)analysis of a condensate heating system,its segments,and components from a marine steam propulsion plant with steam reheating is performed in this paper.It is found that energy analysis of any condensate heating system should be avoided because it is highly influenced by the measuring equipment accuracy and precision.All the components from the observed marine condensate heating system have energy destructions lower than 3 kW,while the energy efficiencies of this system are higher than 99%.The exergy efficiency of closed condensate heaters continuously increases from the lowest to the highest steam pressures(from 70.10%to 92.29%).The ambient temperature variation between 5℃and 45℃notably influences the exergy efficiency change of both low pressure heaters and the low pressure segment equal to 31.61%,12.37%,and 18.35%,respectively.
文摘The mechanic properties, lasting strength and microstructural properties of straight and elbow pipesof 12CrMo, 10CrMo910 and 12CrlMoV low alloy steel main steam piping system after long-time service weretested and studied. The testing results showed that, for straight and elbow pipes of mainsteam piping under theconditions of high temperature and high pressure, the numerical operating performance indexes of their metalchanged with little difference, generally both within 5%, and the Values of elbow were higher than those ofstraight pipes. These phenomena proved that the aging processes of pipe metal at different positions are thesame. And the cause for higher numerical performance indexes of elbow and higher failure rate at elbow posi-tion during operation of steam pipes were investigated.
基金National Natural Science Foundation of China(No.60974119)
文摘Ultra-supercritical(USC) unit is more and more popular in coal-fired power industry.In this paper,closed-loop identification based on subspace model identification(SMI) is introduced for superheated steam temperature system of USC unit.Closed-loop SMI is applied to building step response model of the unit directly.The parameters selection method is proposed to deal with the parameter sensitivity and improve the reliability of the model.Finally,the model is used in model identification of real USC unit.