期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Integration of Manufacturing Services into Virtual Environments over the Internet
1
作者 Huiping Shang Zhengxu Zhao 《International Journal of Automation and computing》 EI 2004年第1期89-106,共18页
Virtual reality (VR) is a rapidly developing technology that has a wide spectrum of industrial and commercial applications. Networked (distributed or shared) virtual environments (VE) are of growing interest to modern... Virtual reality (VR) is a rapidly developing technology that has a wide spectrum of industrial and commercial applications. Networked (distributed or shared) virtual environments (VE) are of growing interest to modern manufacturing industry; a dominating use of networked virtual manufacturing environments (VMEs) is on-line visualisation and collaborative control of 3D information. This has to be supported by real-time data transfer. To meet a broad range of common requirements for Internet-based VE communications, particularly for virtual manufacturing and collaborative design and control, this paper presents a networked virtual environment system that is designed to support networked virtual design and manufacturing. The system is implemented with manufacturing message specification (MMS) standards so as to integrate a range of manufacturing services into networked VEs over the Internet. 展开更多
关键词 Distributed virtual environment networked virtual environment shared virtual environment virtual reality (VR) virtual environment (VE) virtual manufacturing virtual manufacturing device (VMD) manufacturing message specification (MMS) communication protocol
下载PDF
Modes of failure with fractional flow reserve guidewires:Insights from the manufacturer and user facility device experience database
2
作者 Nauman Khalid Yagya Pandey +6 位作者 Umair Khalid Hassan Kamran Jason P Wermers Lovely Chhabra Mahboob Alam Hani Jneid Waleed Tallat Kayani 《World Journal of Cardiology》 2021年第7期223-229,共7页
BACKGROUND Fractional flow reserve(FFR)measurement is commonly used in the cardiac catheterization laboratory to assess the functional significance of coronary arterial plaques.Robust real-world data on complications ... BACKGROUND Fractional flow reserve(FFR)measurement is commonly used in the cardiac catheterization laboratory to assess the functional significance of coronary arterial plaques.Robust real-world data on complications and modes of failure of FFR guidewires are limited.AIM To characterize these outcomes by analyzing the post-marketing surveillance data from the United States Food and Drug Administration Manufacturer and User Facility Device Experience(MAUDE)database for commonly used FFR guidewires.METHODS The MAUDE database was queried from January 2010 through April 2020 for 3 FFR guidewires[PressureWireTM X(Abbott),CometTM(Boston Scientific),and VerrataTM(Philips)]by searching for the following events:“Injury”,“malfunction”,“death”,and“other”.This yielded 544 reports.After excluding incomplete reports,486 reports were analyzed.RESULTS Guidewire tip fracture was the most commonly reported mode of failure,in 174(35.8%)cases followed by guidewire kinking(n=152,31.3%),communication failure(n=141,29.0%),and shaft fracture(n=67,13.8%).In total,133(27.4%)device failures resulted in patient adverse events.The most common adverse event was retained guidewire tip,in 71(53.4%)cases,followed by freshly deployed stent dislodgment(n=26,19.6%)and coronary artery dissection(n=23,17.3%).Seven deaths were reported.CONCLUSION FFR guidewire failures can occur because of various mechanisms and cause patient adverse events.The MAUDE database serves as an important platform for improved collaboration among clinicians,device manufacturers,and regulators to improve device performance and optimize patient outcomes.Our analysis provides mechanistic insights of FFR guidewire failure and associated adverse events but cannot verify causality or provide a comparison among different guidewires. 展开更多
关键词 Fractional flow reserve Coronary guidewire Adverse events Modes of failure Food and Drug Administration Manufacturer and user facility device experience
下载PDF
China's Wearable Device Manufacturers Set Foot in the Global Market
3
作者 Jenny Hu 《China's Foreign Trade》 2016年第6期49-,共1页
According to Q2 Report on China’s Wearable Device Market,China’s wearable devices in Q2 2016 saw an output of 9.54 million units,up 13.2%month-on-month and 81.4%yearon-year.The basic wearable devices representing by... According to Q2 Report on China’s Wearable Device Market,China’s wearable devices in Q2 2016 saw an output of 9.54 million units,up 13.2%month-on-month and 81.4%yearon-year.The basic wearable devices representing by wristband,children watch and smart shoes increased by92.1%year-on-year and the smart wearable devices represented by smart watch increased by 3.4%year-on-year.'Unlike the overseas 展开更多
关键词 China’s Wearable device Manufacturers Set Foot in the Global Market
下载PDF
Complications associated with energy-based devices during thyroidectomy from 2010–2020
4
作者 Esther Lee Jane Y.Tong +4 位作者 Luke J.Pasick Daniel A.Benito Arjun Joshi Punam G.Thakkar Joseph F.Goodman 《World Journal of Otorhinolaryngology-Head and Neck Surgery》 CSCD 2023年第1期35-44,共10页
Objective:Harmonic Focus(Ethicon,Johnson and Johnson,Cincinnati,OH,USA),LigaSure Small Jaw(Medtronic,Covidien Products,Minneapolis,MN,USA),and Thunderbeat Open Fine Jaw(Olympus,Japan)are electrosurgical instruments us... Objective:Harmonic Focus(Ethicon,Johnson and Johnson,Cincinnati,OH,USA),LigaSure Small Jaw(Medtronic,Covidien Products,Minneapolis,MN,USA),and Thunderbeat Open Fine Jaw(Olympus,Japan)are electrosurgical instruments used widely in head and neck surgery.The study aims to compare device malfunctions,adverse events to patients,operative injuries,and interventions related to Harmonic,LigaSure,and Thunderbeat use during thyroidectomy.Methods:The US Food and Drug Administration's Manufacture and User Facility Device Experience(MAUDE)database was queried for adverse events associated with Harmonic,LigaSure,and Thunderbeat from January 2005 to August 2020.Data were extracted from reports pertaining to thyroidectomy.Results:Of the 620 adverse events extracted,394(63.5%)involved Harmonic,134(21.6%)LigaSure,and 92(14.8%)Thunderbeat.The reported device malfunctions most frequently associated with Harmonic was damage to the blade(110(27.9%)),LigaSure was inappropriate function(47(43.1%)),Thunderbeat was damage to the tissue or Teflon pad(27(30.7%)),respectively.Burn injury and incomplete hemostasis were the most commonly reported adverse events.The operative injury reported most frequently when using Harmonic and LigaSure was burn injury.No operator injuries were reported with Thunderbeat use.Conclusion:The most frequently reported device malfunctions were damage to the blade,inappropriate function,and damage to the tissue or Teflon pad.The most frequently reported adverse events to patients was a burn injury and incomplete hemostasis.Interventions aimed at improving physician education may help reduce adverse events attributed to improper use. 展开更多
关键词 Adverse events HARMONIC LIGASURE Manufacture and User Facility device Experience Patient safety Quality Thunderbeat THYROIDECTOMY
原文传递
Collection and Management of Shop-floor Controller Data
5
作者 陶丹 杨建华 吴澄 《Tsinghua Science and Technology》 SCIE EI CAS 1999年第1期19-22,共4页
This paper describes shop floor data collection and management. An architecture is presented for a shop floor data collection and management system based on the analysis of the features of these data. Two critical asp... This paper describes shop floor data collection and management. An architecture is presented for a shop floor data collection and management system based on the analysis of the features of these data. Two critical aspects of the system are discussed in detail: the various communication protocols between computers and machines, and the real time demands of the shop floor controller. 展开更多
关键词 shop floor controller data collection and management real time virtual manufacturing device (VMD) manufacturing message specification (MMS)
原文传递
Preparation and characterization of In_(0.82)Ga_(0.18)As PIN photodetectors
6
作者 刘霞 曹连振 +3 位作者 逯怀新 李英德 宋航 蒋红 《Optoelectronics Letters》 EI 2016年第1期8-11,共4页
Using two-step growth method and buffer layer annealing treatment,the double heterojunction structures of In_(0.82)Ga_(0.18) As epilayer capped with In As_(0.6)P0.4 layer were prepared on In P substrate by low pressur... Using two-step growth method and buffer layer annealing treatment,the double heterojunction structures of In_(0.82)Ga_(0.18) As epilayer capped with In As_(0.6)P0.4 layer were prepared on In P substrate by low pressure metal organic chemical vapor deposition(LP-MOCVD).Based on the high quality In_(0.82)Ga_(0.18) As structures,the In_(0.82)Ga_(0.18) As PIN photodetector with cut-off wavelength of 2.56 μm at room temperature was fabricated by planar semiconductor technology,and the device performance was investigated in detail.The typical dark current at the reverse bias VR=10 m V and the resistance area product R0 A are 5.02 μA and 0.29 ?·cm2 at 296 K and 5.98 n A and 405.2 ?·cm2 at 116 K,respectively.The calculated peak detectivities of the In_(0.82)Ga_(0.18) As photodetector are 1.21×1010 cm·Hz1/2/W at 296 K and 4.39×1011 cm·Hz1/2/W at 116 K respectively,where the quantum efficiency η=0.7 at peak wavelength is supposed.The results show that the detection performance of In_(0.82)Ga_(0.18) As prepared by two-step growth method can be improved greatly. 展开更多
关键词 HETEROJUNCTIONS INDIUM Metallorganic chemical vapor deposition Organic chemicals ORGANOMETALLICS PHOTODETECTORS PHOTONS Semiconductor device manufacture
原文传递
上一页 1 下一页 到第