期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Comprehensive Treatment Uncertainty Analysis and PTV Margin Estimation for Fiducial Tracking in Robotic Liver Stereotactic Body Radiation Therapy
1
作者 Zhi-wen LIANG Meng-lan ZHAI +7 位作者 Biao TU Xin NIE Xiao-hui ZHU Jun-ping CHENG Guo-quan LI Dan-dan YU Tao ZHANG Sheng ZHANG 《Current Medical Science》 SCIE CAS 2023年第3期572-578,共7页
Objective This study aims to quantify the uncertainties of CyberKnife Synchrony fiducial tracking for liver stereotactic body radiation therapy(SBRT)cases,and evaluate the required planning target volume(PTV)margins.M... Objective This study aims to quantify the uncertainties of CyberKnife Synchrony fiducial tracking for liver stereotactic body radiation therapy(SBRT)cases,and evaluate the required planning target volume(PTV)margins.Methods A total of 11 liver tumor patients with a total of 57 fractions,who underwent SBRT with synchronous fiducial tracking,were enrolled for the present study.The correlation/prediction model error,geometric error,and beam targeting error were quantified to determine the patient-level and fraction-level individual composite treatment uncertainties.The composite uncertainties and multiple margin recipes were compared for scenarios with and without rotation correction during treatment.Results The correlation model error-related uncertainty was 4.3±1.8,1.4±0.5 and 1.8±0.7 mm in the superior-inferior(SI),left-right,and anterior-posterior directions,respectively.These were the primary contributors among all uncertainty sources.The geometric error significantly increased for treatments without rotation correction.The fraction-level composite uncertainties had a long tail distribution.Furthermore,the generally used 5-mm isotropic margin covered all uncertainties in the left-right and anterior-posterior directions,and only 75%of uncertainties in the SI direction.In order to cover 90%of uncertainties in the SI direction,an 8-mm margin would be needed.For scenarios without rotation correction,additional safety margins should be added,especially in the superior-inferior and anterior-posterior directions.Conclusion The present study revealed that the correlation model error contributes to most of the uncertainties in the results.Most patients/fractions can be covered by a 5-mm margin.Patients with large treatment uncertainties might need a patient-specific margin. 展开更多
关键词 CYBERKNIFE fiducial tracking liver cancer stereotactic body radiation therapy margin expansion
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部