In this paper, a successfully studied and developed master - slave muld - microcomputers control system based on PC - BUS for hollow spindle fancy yarn spinning machine, mainly Its overall scheme, software and hardwar...In this paper, a successfully studied and developed master - slave muld - microcomputers control system based on PC - BUS for hollow spindle fancy yarn spinning machine, mainly Its overall scheme, software and hardware construction, is introduced. Spinning experiments show that the system achieves satisfactory result. This system can solve the diftkultles of mechatronical fusion between domestic hollow splndk fancy yarn spuming muchine and its microcomputer control technology.展开更多
The timing and master control logic (MCL) units are the most important function units of the diagnostic neutral beam (DNB) power supply control system. The units control the operation of nine power supply subsyste...The timing and master control logic (MCL) units are the most important function units of the diagnostic neutral beam (DNB) power supply control system. The units control the operation of nine power supply subsystems of the DNB system, and provide protection for the DNB system from faults such as beam source arc down. Based on the characteristics of the DNB power supply system, the timing and MCL units have been designed, fabricated and tested. Experiments prove that the timing unit is convenient, flexible and reliable, and the MCL is functional.展开更多
当微电网由并网模式进入离网模式时,储能变流器和光伏逆变器采用传统控制方式可能会造成微电网系统振荡、储能系统过充和过放的问题。采用储能变流器和光伏逆变器并联运行的微电网结构,通过分析微电网各电源出力情况,提出一种在微电网...当微电网由并网模式进入离网模式时,储能变流器和光伏逆变器采用传统控制方式可能会造成微电网系统振荡、储能系统过充和过放的问题。采用储能变流器和光伏逆变器并联运行的微电网结构,通过分析微电网各电源出力情况,提出一种在微电网离网时刻,考虑储能系统荷电状态(State of charge,SOC)的变主从协同控制策略,即将主从控制、对等控制、分层控制的优势结合起来,实现储能变流器在二次调压调频的下垂控制和PQ控制间灵活切换,实现微电网的平滑离网,防止储能系统过充和过放。最后搭建仿真模型,对所提方法的有效性进行验证。展开更多
文摘In this paper, a successfully studied and developed master - slave muld - microcomputers control system based on PC - BUS for hollow spindle fancy yarn spinning machine, mainly Its overall scheme, software and hardware construction, is introduced. Spinning experiments show that the system achieves satisfactory result. This system can solve the diftkultles of mechatronical fusion between domestic hollow splndk fancy yarn spuming muchine and its microcomputer control technology.
基金Meg-science Engineering Project of the Chinese Academy of Sciences
文摘The timing and master control logic (MCL) units are the most important function units of the diagnostic neutral beam (DNB) power supply control system. The units control the operation of nine power supply subsystems of the DNB system, and provide protection for the DNB system from faults such as beam source arc down. Based on the characteristics of the DNB power supply system, the timing and MCL units have been designed, fabricated and tested. Experiments prove that the timing unit is convenient, flexible and reliable, and the MCL is functional.
文摘当微电网由并网模式进入离网模式时,储能变流器和光伏逆变器采用传统控制方式可能会造成微电网系统振荡、储能系统过充和过放的问题。采用储能变流器和光伏逆变器并联运行的微电网结构,通过分析微电网各电源出力情况,提出一种在微电网离网时刻,考虑储能系统荷电状态(State of charge,SOC)的变主从协同控制策略,即将主从控制、对等控制、分层控制的优势结合起来,实现储能变流器在二次调压调频的下垂控制和PQ控制间灵活切换,实现微电网的平滑离网,防止储能系统过充和过放。最后搭建仿真模型,对所提方法的有效性进行验证。