Rapid Profiling of Alkaloids in Several Medicinal Herbs by Matrix-assisted Laser Desorption/Ionization Mass Spectrometry 被引量:2
1
作者 LU Lin YUE Hao +3 位作者 SONG Feng-rui TSAO Rong LIU Zhi-qiang LIU Shu-ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2010年第1期11-16,共6页
A simple method was developed for rapid and direct profiling of alkaloids in medical herbs via matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF MS). The dry herbs were first gro... A simple method was developed for rapid and direct profiling of alkaloids in medical herbs via matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF MS). The dry herbs were first ground to powder and passed through a stainless steel sieve, mixed with the matrix solution to form a homogeneous suspension, which was then directly applied to MALDI analysis. Several matrices were investigated and 2,5- dihydroxybenzoic acid(DHB) was chosen as the optimized one, and the particle with small size was found to favor the analysis. Using this method, the profiles of alkaloids in several medical herbs were readily obtained, and the toxicities of crude and processed Radix Aconiti Lateralis Preparata were compared via the relative intensities of the peaks of the corresponding toxic components shown in their MALDI spectra. This method therefore provides a rapid and reliable protocol for obtaining profiles of alkaloids in medical herbs by using MALDI-TOF MS. 展开更多
关键词 matrix-assisted laser desorption/ionization ALKALOID Medical herb
下载PDF
Analysis of Single Nucleotide Polymorphism in Human Paraoxonase 1 Gene(Q192R) with Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry 被引量:1
2
作者 SUN Ya-dong SUN Shu-chen +2 位作者 WANG Zhi YANG Yang ZHANG Jin 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2006年第3期394-396,共3页
Introduction Single nucleotide polymorphisms (SNPs) are the most abundant DNA markers in the human genome occurring at a frequency of one in every 500--1000 nucleotides. A variety of methods have been used for the ... Introduction Single nucleotide polymorphisms (SNPs) are the most abundant DNA markers in the human genome occurring at a frequency of one in every 500--1000 nucleotides. A variety of methods have been used for the analysis of single nucleotide polymorphisms, including restriction fragment length polymorphism (RFLP), direct sequencing by using laser-induced fluorescence detectionTM, fluorescence energy transfer, MALDI-TOF MS combined with primer extension or invasive cleavage, and fluorescence polarization. During the past two decades, mass spectrometry has become a very popular tool in the analysis of biomolecules and is perfectly suited to the analysis of single nucleotide polymorphisms (SNPs) due to its speed, low cost, and accuracy. In this work, we used MALDI TOF mass spectrometry to detect the fragments of restriction endonuclease hydrolysis of PCR products flanking a SNP located at paraoxonase 1(Q192R). Compared with electrophoresis, this method requires less time of analysis and possess a higher accuracy. 展开更多
关键词 Single nucleotide polymorphism Human paraoxonase 1 gene matrix-assisted laser desorption/ionizationtime-of-flight mass spectrometry
下载PDF
A novel sample preparation method of matrix-assisted laser desorption/ionization time of flight mass spectrometry for polystyrene
3
作者 Shu Zhang Zhen Wen Zhao +3 位作者 Lei Xiong Bin Xin Wei Hua Hu Shao Xiang Xiong 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期718-721,共4页
关键词 POLYSTYRENE matrix-assisted laser desorption/ionization time of flight mass spectrometry Three-layer method
下载PDF
MicrobMatcher: a microbial comparison software based on matrix-assisted laser desorption/ionization with time-of-flight mass spectrometry
4
作者 Yizhen Fu Feng Liu Yalu Ye 《Journal of Biomedical Science and Engineering》 2011年第5期403-409,共7页
Matrix-assisted Laser Desorption/Ionization with Time-of-flight Mass Spectrometry (MALDI-TOFMS) was investigated as a method for the rapid identifica-tion of species. Current demand in microbial identi-fication is how... Matrix-assisted Laser Desorption/Ionization with Time-of-flight Mass Spectrometry (MALDI-TOFMS) was investigated as a method for the rapid identifica-tion of species. Current demand in microbial identi-fication is how to compare unknown strains to the known one quickly, semi-automatically and accurately. In this paper, we present a software tool that allows flexibly microbial matching in a user-friendly way, by letting the users to customize comparison parameters including: in vitro transcription enzyme, mass tolerance,minimum fragment length, intensity threshold and corresponding weights. We provide three spectral scoring functions to compute the affin-ity between the species. Therefore, the precision of microbial comparison increases. To test and verify this tool, we employed experimental spectral data based on MALDI-TOFMS and the gene sequences of E.coli and Salmonella. This software is written in Java for cross-platform intention. 展开更多
关键词 MICROBIAL Comparison matrix-assisted laser desorption/Ionization with TIME-OF-FLIGHT Mass spectrometry
下载PDF
Detection of lung adenocarcinoma using magnetic beads based matrix-assisted laser desorption/ionization time-of-flight mass spectrometry serum protein profiling 被引量:13
5
作者 LIN Xiu-li YANG Shuan-ying +5 位作者 DU Jie TIAN Ying-xuan BU Li-na HUO Shu-fen WANG Feng-peng NAN Yan-dong 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第1期34-39,共6页
Background Recently, due to the rapid development of proteomic techniques, great advance has been made in many scientific fields. We aimed to use magnetic beads (liquid chip) based matrix-assisted laser desorption/i... Background Recently, due to the rapid development of proteomic techniques, great advance has been made in many scientific fields. We aimed to use magnetic beads (liquid chip) based matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) technology to screen distinctive biomarkers for lung adenocarcinoma (adCA), and to establish the diagnostic protein profiles. Methods Using weak cation exchange magnetic beads (MB-WCX) to isolate and purify low molecular weight proteins from sera of 35 lung adCA, 46 benign lung diseases (BLDs) and 44 healthy individuals. The resulting spectra gained by anchor chip-MALDI-TOF-MS were analyzed by ClinProTools and a pattern recognition genetic algorithm (GA). Results In the working mass range of 800-10 000 Da, 99 distinctive peaks were resolved in lung adCA versus BLDs, while 101 peaks were resolved in lung adCA versus healthy persons. The profile gained by GA that could distinguish adCA from BLDs was comprised of 4053.88, 4209.57 and 3883.33 Da with sensitivity of 80%, specificity of 93%, while that could separate adCA from healthy control was comprised of 2951.83 Da and 4209.73 Da with sensitivity of 94%, specificity of 95%. The sensitivity provided by carcinoembryonic antigen (CEA) in this experiment was significantly lower than our discriminatory profiles (P 〈0.005). We further identified a eukaryotic peptide chain release factor GTP-binding subunit (eRF3b) (4209 Da) and a complement C3f (1865 Da) that may serve as candidate biomarkers for lung adCA. Conclusion Magnetic beads based MALDI-TOF-MS technology can rapidly and effectively screen distinctive proteins/polypeptides from sera of lung adCA patients and controls, which has potential value for establishing a new diagnostic method for lung adCA. 展开更多
关键词 magnetic beads matrix-assisted laser desorption/ionization-mass spectrometry lung adenocarcinoma SERUM PROTEOMICS
原文传递
Detection of Sialylated N-Linked Glycans by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry
6
作者 PENG Yanfei XU Xiaojuan 《Wuhan University Journal of Natural Sciences》 CAS 2014年第3期245-252,共8页
Native and methyl-esterified sialylated glycans were analyzed with 2,4,6-trihydroxyacetophenone(THAP)and 2,5-dihydroxybenzoic acid(DHB)as matrix by a matrix-assisted laser desorption/ionization time-of-flight mass... Native and methyl-esterified sialylated glycans were analyzed with 2,4,6-trihydroxyacetophenone(THAP)and 2,5-dihydroxybenzoic acid(DHB)as matrix by a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer(MALDI-TOF MS).High quality negative-ion spectra of commercial sialylated glycan were obtained with THAP as matrix.Detection limit of the glycan was less than 0.1 pmol.After methyl esterification of sialic acid(SA)residue,sialylated glycans were detected sensitively in the positive-ion mode using DHB as matrix.Neutral and sialylated glycans from the mixture of asialofetuin and fetuin were methylesterified and simultaneously recognized in one manipulation.Methyl esterification of SA residue offers a convenient and sensitive way to identify the structure of N-linked glycans for glycan profiling. 展开更多
关键词 sialic acid glycans methyl esterification matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF MS)
原文传递
Matrix-assisted laser desorption/ionization time of flight mass spectrometry in the genetic basis of systemic lupus erythematosus and the complicating kidney injury
7
作者 ZHOU Xiao-shuang LI Jing WANG Li-hua WANG Chen WU Rui-ping LI Rong-shan 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第15期2821-2825,共5页
Background It is necessary to develop some innovative methods to reveal and discover the novel (SLE)-related protein molecules. In the present study, matrix-assisted laser desorption/ionization time of flight mass s... Background It is necessary to develop some innovative methods to reveal and discover the novel (SLE)-related protein molecules. In the present study, matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI- TOF MS) was employed to detect the differential expression of serum polypeptides in the patients with systemic lupus erythematosus (SLE) presenting with a family history or complicating with kidney injury so as to identify the proteins associated with the genetic factors and kidney injury in SLE. Methods The subjects recruited were divided into four groups, that is, a group of SLE patients with both family history and kidney injury, a group of SLE patients with only kidney injury but no family history, a group of SLE patients with neither family history nor kidney injury, and a control group consisting of healthy volunteers. By adopting MALDI-TOF MS analysis, the serum samples obtained from the three groups of SLE patients were examined and compared with those from the control group; the categorized peptide fingerprint profile was established via the biological data collected from the samples. Results The expression of protein with a mlz of 4207 Da increased significantly in SLE patients; the protein with a ml z of 2658 Da was expressed in all SLE patients; three proteins (with mlz of 1465, 5332, and 5900 Da respectively) were expressed in the SLE patients complicated with kidney injury and the protein with a mlz of 1943 Da was expressed in SLE patients with family history. Conclusion A number of differential proteins were successfully detected and identified through MALDI-TOF MS detection and these proteins may be associated with the genetic basis of SLE and the complicating kidney injury. 展开更多
关键词 systemic lupus erythematosus genetic diseases kidney injury matrix-assisted laser desorption/ionization-mas sspectrometry
原文传递
磁性氮化碳复合材料的制备及其对磷酸化肽的富集
8
作者 姜丽艳 张玮璐 +1 位作者 赵璐 胡良海 《色谱》 CAS CSCD 北大核心 2024年第6期564-571,共8页
蛋白质的磷酸化在细胞信号传导和疾病发生发展中起着重要作用,但磷酸化的动态变化和低丰度的特点使得对其直接分析有着较大的困难。为了解决磷酸化肽难离子化、检测丰度低的瓶颈问题,本研究制备了一种磁性氮化碳复合材料,结合基质辅助... 蛋白质的磷酸化在细胞信号传导和疾病发生发展中起着重要作用,但磷酸化的动态变化和低丰度的特点使得对其直接分析有着较大的困难。为了解决磷酸化肽难离子化、检测丰度低的瓶颈问题,本研究制备了一种磁性氮化碳复合材料,结合基质辅助激光解吸电离飞行时间质谱(MALDI-TOF-MS),建立了一种对复杂样品中低丰度磷酸化肽富集与分析的方法。采用电子显微镜、红外光谱分析及X射线衍射分析等手段对合成的磁性氮化碳材料进行表征。以酪蛋白酶解产物为实验模型,发现磁性氮化碳材料能够实现对磷酸化肽的高选择性富集和高灵敏度检测,检出限为0.1 fmol。选择脱脂牛奶、人唾液和人血清为实际分析样品,发现磁性氮化碳材料对微量蛋白生物样品中磷酸化肽的分析具有较高的应用潜力。 展开更多
关键词 氮化碳 磁性固相萃取 基质辅助激光解吸电离飞行时间质谱 磷酸化肽 富集
下载PDF
饮用水中高分子量消毒副产物的检测识别方法
9
作者 韩亮亮 赵佳焱 +5 位作者 李梦媛 董慧峪 楚文海 周庆 施鹏 潘旸 《环境化学》 CAS CSCD 北大核心 2024年第1期160-173,共14页
消毒是饮用水处理过程中的重要步骤,但普遍采用的氯系消毒剂在杀灭细菌病毒的同时,能产生大量具有“三致”效应的卤代消毒副产物(DBPs),严重威胁了饮用水的化学安全.研究人员已在饮用水中陆续检测并识别出700多种DBPs,但这些已知DBPs均... 消毒是饮用水处理过程中的重要步骤,但普遍采用的氯系消毒剂在杀灭细菌病毒的同时,能产生大量具有“三致”效应的卤代消毒副产物(DBPs),严重威胁了饮用水的化学安全.研究人员已在饮用水中陆续检测并识别出700多种DBPs,但这些已知DBPs均为分子量小于800 Da的低分子量DBPs,目前对高分子量DBPs的认识还较为有限.本研究建立了基于基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)的高分子量DBPs检测方法,发现在基质为2,5-二羟基苯甲酸,阳离子化试剂为三氟乙酸钠,使用三明治法点靶,反射-正离子模式,90%激光强度时,信噪比和信号重现性达到最优,信噪比之和达到了136.2,变异系数(CV)则为4.77%.利用上述方法,在模拟饮用水中检测到5种新的高分子量DBPs.在此基础上,通过同位素模式分析、TOF/TOF串联质谱和数据库验证,建立了针对未知高分子量DBPs的分子式/结构式识别方法,确定新的高分子量DBPs为寡糖羧酸类物质. 展开更多
关键词 高分子量消毒副产物 基质辅助激光解吸电离飞行时间质谱 阳离子化试剂 检测 识别
下载PDF
血培养阳性样本快速菌种鉴定和药物敏感性分析
10
作者 李安琪 张澍雅 +6 位作者 何珊娜 陈巧巧 吕绮 吕婉飞 李春仙 王卫华 郑琳 《检验医学》 CAS 2024年第3期243-248,共6页
目的分析分离胶离心富集和5 h培养2种前处理方法在血培养阳性样本快速菌种鉴定和快速药物敏感性分析中的临床应用价值。方法收集2021年10月—2022年10月宁波大学附属第一医院报阳的血培养样本211例,分别采用分离胶离心富集和5 h培养(快... 目的分析分离胶离心富集和5 h培养2种前处理方法在血培养阳性样本快速菌种鉴定和快速药物敏感性分析中的临床应用价值。方法收集2021年10月—2022年10月宁波大学附属第一医院报阳的血培养样本211例,分别采用分离胶离心富集和5 h培养(快速方法),以及12 h培养(标准方法)3种方法进行前处理。采用基质辅助激光解吸电离飞行时间质谱(MALDI-TOF-MS,简称MS)对3种方法处理的血培养阳性样本进行快速菌种鉴定。采用自动化鉴定药敏仪对156例需氧瓶报阳血培养样本进行药物敏感性试验。以常规培养(18~24 h)+MS鉴定结果为标准,比较5 h培养+MS和分离胶离心富集+MS 2种快速方法菌株鉴定准确率。以培养24 h后仪器法药物敏感性试验结果为标准,判断5 h培养和分离胶离心富集后仪器法药物敏感性试验结果与标准方法的一致率。结果2种快速方法鉴定准确率最高的菌种为粪肠球菌,分别为100.00%、87.50%;5 h培养+MS对链球菌属的鉴定准确率较低(33.33%)。2种快速方法对肠杆菌科和非发酵菌的药物敏感性分析结果与标准培养+MS的药物敏感性分析结果一致性分别超过73.00%和85.00%;对葡萄球菌属和肠球菌属部分抗菌药物的药物敏感性分析结果一致性达100.00%;对万古霉素的药物敏感性分析结果一致性最低,为70.73%。结论5 h培养+MS和分离胶离心富集+MS可快速判断血培养阳性样本病原菌种类及其耐药性,准确率较高,适合在临床微生物实验室推广。 展开更多
关键词 血培养 病原菌鉴定 基质辅助激光解吸电离飞行时间质谱 短时培养法
下载PDF
MALDI-TOF MS直接靶板微滴生长测定法在CRKP快速检测中的应用
11
作者 吴昕哲 茆海丰 +2 位作者 杨晋 左春磊 金丹婷 《检验医学》 CAS 2024年第6期587-591,共5页
目的探讨基于基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)的直接靶板微滴生长测定(DOT-MGA)法快速筛查碳青霉烯类耐药肺炎克雷伯菌(CRKP)的准确性和临床应用价值。方法收集2020—2021年连云港市第一人民医院肺炎克雷伯菌临床分离株... 目的探讨基于基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)的直接靶板微滴生长测定(DOT-MGA)法快速筛查碳青霉烯类耐药肺炎克雷伯菌(CRKP)的准确性和临床应用价值。方法收集2020—2021年连云港市第一人民医院肺炎克雷伯菌临床分离株251株,其中美罗培南敏感123株,CRKP128株。采用DOT-MGA法对4和6μL 2种取样量的所有菌株进行美罗培南耐药性检测。采用微量肉汤稀释法测定菌株的美罗培南最小抑菌浓度(MIC)。以微量肉汤稀释法耐药性分析结果为标准,评价DOT-MGA法耐药性检测结果的准确性。结果以微量肉汤稀释法为标准,孵育生长4 h后,DOT-MGA法2种取样量的敏感性和阴性预测值均为100.0%,其中4μL取样量检测CRKP的特异性为92.5%,阳性预测值为92.8%;6μL取样量检测CRKP的特异性为89.8%,阳性预测值为90.1%。123株美罗培南敏感株的美罗培南MIC_(50)为0.125μg·mL^(-1),MIC_(90)为0.25μg·mL^(-1);128株美罗培南耐药株的MIC_(50)和MIC_(90)均为≥128μg·mL^(-1)。DOT-MGA法与微量肉汤稀释法的一致性分析结果显示,4μL加样量Kappa值为0.88,6μL加样量Kappa值为0.83。结论基于MALDITOF MS的DOT-MGA法筛查CRKP具有较高的准确性,且简便、快捷,可用于快速检测CRKP。 展开更多
关键词 碳青霉烯类耐药肺炎克雷伯菌 基质辅助激光解吸电离飞行时间质谱 直接靶板微滴生长测定法 微量肉汤稀释法
下载PDF
基质辅助激光解吸电离-飞行时间质谱法快速测定米饭和乳制品中蜡样芽孢杆菌呕吐毒素Cereulide
12
作者 曾羲 王宇 +3 位作者 徐巨才 黄穗东 王涓 徐振林 《食品科学》 EI CAS CSCD 北大核心 2024年第1期232-238,共7页
建立基质辅助激光解吸电离-飞行时间质谱(matrix-assisted laser desorption ionization time-of-flight mass spectrometry,MALDI-TOF MS)法分析蜡样芽孢杆菌呕吐毒素Cereulide的快速检测方法。分析了Cereulide标准物质的裂解规律,考... 建立基质辅助激光解吸电离-飞行时间质谱(matrix-assisted laser desorption ionization time-of-flight mass spectrometry,MALDI-TOF MS)法分析蜡样芽孢杆菌呕吐毒素Cereulide的快速检测方法。分析了Cereulide标准物质的裂解规律,考察基质种类、点靶方式、基质溶剂和用量、激光强度等对Cereulide的质谱信号强度的影响,并进行方法学验证和实际样品检测。结果表明,选择以α-氰基-4-羟基肉桂酸为基质,均匀分散在50%乙腈-水(含0.1%三氟乙酸)中,采用先点基质再点样品的点样方式,反射线性正离子模式下选择激光强度70%进行食品中MALDI-TOF MS筛查时,可检测到Cereulide的[M+Na]^(+)和[M+K]^(+)目标离子峰,此质谱信号稳定、强度高、响应重复性好。方法学验证结果表明,Cereulide的[M+Na]^(+)和[M+K]^(+)目标离子峰在5~100 ng/mL范围内线性好,相关系数(r)>0.99;方法的检出限分别为3.0 ng/g和5.0 ng/g;对米饭和牛乳样品的加标回收率为73.3%~118.2%,相对标准偏差为0.3%~10.9%(n=6)。本方法分析速度快、准确性高、灵敏度好、抗干扰能力强、无需内标即可实现对米饭和乳制品中Cereulide的批量筛查和检测。 展开更多
关键词 基质辅助激光解吸-电离飞行时间质谱 蜡样芽孢杆菌 呕吐毒素 α-氰基-4-羟基肉桂酸
下载PDF
半夏炮制过程中毒性凝集素蛋白的基质辅助激光解吸电离飞行时间质谱分析
13
作者 黄益曼 李春晖 +5 位作者 柏家辉 陆颖洁 李添 董志颖 苏越 郭寅龙 《质谱学报》 EI CAS CSCD 北大核心 2024年第2期226-236,共11页
基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)受灵敏度和重复性的影响,对完整蛋白的定量分析存在困难。本研究采用纤维素纳米晶体(CNC)辅助MALDI-TOF MS,结合内标法定量分析半夏炮制过程中半夏凝集素(PTL),通过优化CNC辅助样本制备... 基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)受灵敏度和重复性的影响,对完整蛋白的定量分析存在困难。本研究采用纤维素纳米晶体(CNC)辅助MALDI-TOF MS,结合内标法定量分析半夏炮制过程中半夏凝集素(PTL),通过优化CNC辅助样本制备的时长和比例,以麦胚凝集素(TVL)为内标,直接分析不同炮制程度半夏各炮制品及其浸泡上清液中PTL含量。结果表明,CNC辅助MALDI样本制备有效提升了MALDI-TOF MS定量分析的线性和重复性。随着炮制时间的延长,姜半夏、清半夏和法半夏炮制品的PTL含量逐渐下降,浸泡上清液中PTL含量逐渐上升。其中,由于pH值的改变,法半夏炮制品浸泡上清液中PTL含量呈先上升后下降的趋势。此外,将该方法应用于不同饮片生产企业的多批次半夏炮制品饮片中,均未检出PTL。该方法操作简便,可有效分析半夏炮制过程中PTL含量的变化,为研究半夏炮制过程对PTL的影响提供了参考。 展开更多
关键词 半夏 炮制方法 半夏凝集素(PTL) 纤维素纳米晶体(CNC) 基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)
下载PDF
基质辅助激光解吸电离飞行时间质谱在食源性致病菌鉴定中的应用
14
作者 任婷 史敏 +2 位作者 刘聪慧 黄一刚 裴金金 《食品安全质量检测学报》 CAS 2024年第5期62-68,共7页
基质辅助激光解吸电离飞行时间质谱(matrix assisted laser desorption ionization time of flight mass spectrometry,MALDI-TOF MS)作为近年来发展的新型食源性致病菌鉴定技术,具有灵敏、准确、检测速度快等优点,该技术为食品病原微... 基质辅助激光解吸电离飞行时间质谱(matrix assisted laser desorption ionization time of flight mass spectrometry,MALDI-TOF MS)作为近年来发展的新型食源性致病菌鉴定技术,具有灵敏、准确、检测速度快等优点,该技术为食品病原微生物靶标性监测和食品安全事件应急检验提供了一种高效的鉴别技术参考,在保障民众生命健康和经济社会发展上发挥了重要作用。本文检索了近年来国内外MALDI-TOF MS技术在食源性致病菌检测中的相关研究案例,简要综述了MALDI-TOF MS检测原理、工作流程,影响鉴定结果的主要因素,介绍了MALDI-TOF MS技术应用于食源性致病菌检测中的实际案例,在此基础上分别从参考菌株数据库建设、标准化程序规范等方面对MALDI-TOF MS技术在食源性致病菌检测领域的未来研究方向进行展望,以期为后续食品安全检测及快速监管食源性致病菌污染提供技术支持。 展开更多
关键词 基质辅助激光解吸电离飞行时间质谱 食源性致病菌 鉴定
下载PDF
MALDI-TOF MS技术在临床微生物检验中的应用
15
作者 段雪寒 吴华 《检验医学》 CAS 2024年第4期410-414,共5页
随着科学技术的发展,新技术在医学检验中的应用越来越广泛。相较于传统微生物鉴定繁琐、耗时的工作流程,基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS,简称MS)技术因其快速、灵敏、简便、省时和特异性高等特点,在菌种鉴定、耐药监测... 随着科学技术的发展,新技术在医学检验中的应用越来越广泛。相较于传统微生物鉴定繁琐、耗时的工作流程,基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS,简称MS)技术因其快速、灵敏、简便、省时和特异性高等特点,在菌种鉴定、耐药监测、突变菌株鉴别等方面发挥巨大的作用,逐渐成为临床微生物实验室不可或缺的微生物鉴定工具。虽然MS技术鉴定菌种高度依赖数据库,也在一定程度上受限于临床样本质量,但其在临床微生物检验中仍有较大的空间待开发。文章对MS技术在临床微生物检验中的应用进行综述。 展开更多
关键词 基质辅助激光解吸电离飞行时间质谱 快速鉴定 数据库 耐药监测
下载PDF
MALDI-TOF MS法快速鉴定散装即食食品中3种食源性致病菌 被引量:1
16
作者 崔洁 林吉恒 +3 位作者 孙瑛 严卓彦 夏瑛瑛 黄朱梁 《食品工业科技》 CAS 北大核心 2024年第5期253-270,共18页
本研究旨在利用基质辅助激光解吸电离飞行时间质谱法(Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry,MALDI-TOF MS)快速检测并鉴定散装即食食品中的沙门氏菌、金黄色葡萄球菌和蜡样芽孢杆菌3种食源性... 本研究旨在利用基质辅助激光解吸电离飞行时间质谱法(Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry,MALDI-TOF MS)快速检测并鉴定散装即食食品中的沙门氏菌、金黄色葡萄球菌和蜡样芽孢杆菌3种食源性致病菌。通过对点样方式、前处理方式、不同培养基及培养时间等各项实验条件的优化筛选确定最佳方法,并考察其检测限和稳定性,同时用所建立的方法与多重PCR法、VITEK 2等生化鉴定法进行结果比对,比较三者鉴定结果的一致性,最后进行批量食品样本检测来探寻MALDI-TOF MS鉴定法在散装即食食品中的适用性。结果表明,三种目标菌同一批次及不同传代次数的鉴定得分均大于95%,变异系数均小于2%,所建立的方法重复性和稳定性良好,且检测限为10^(5)CFU/mL,MALDI-TOF MS菌株鉴定结果与多重PCR法、生化鉴定法结果高度一致,且比二者检测用时更短,更加特异高效;在点样方式上,相较于夹心法与混合干滴法,三种覆盖法点样平均鉴定得分更高,均为99.9%,其中1μL+1μL覆盖法点样可获得的平均峰数目更多,特征峰更复杂且强度更高;而在前处理方式上,甲酸乙腈法与其他两种菌体处理方法相比可获得更多的出峰量和更高的峰强度,平均鉴定得分均在98%以上,且与数据库中图谱匹配度更高。综上所述,MALDI-TOF MS法在致病菌鉴定方面不仅灵敏特异、准确快速,且操作简便、结果直观,作为国标法的有力补充,为食源性致病菌的分析鉴定与分型溯源提供了新思路。 展开更多
关键词 基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS) 散装即食食品 沙门氏菌 黄色葡萄球菌 蜡样芽孢杆菌
下载PDF
宁夏桶装水中铜绿假单胞菌的污染情况、耐药性及同源性分析
17
作者 冯秀娟 董川 +1 位作者 苏洋 高俊峰 《现代食品科技》 CAS 北大核心 2024年第6期295-302,共8页
为综合评价宁夏桶装水生产企业铜绿假单胞菌污染情况、耐药性及系统进化关系,确定污染来源,提升产品质量,该研究对企业各生产环节的水样进行铜绿假单胞菌检测,并采用全自动微生物鉴定系统(VITEK-2)、基质辅助激光解吸电离-飞行时间质谱... 为综合评价宁夏桶装水生产企业铜绿假单胞菌污染情况、耐药性及系统进化关系,确定污染来源,提升产品质量,该研究对企业各生产环节的水样进行铜绿假单胞菌检测,并采用全自动微生物鉴定系统(VITEK-2)、基质辅助激光解吸电离-飞行时间质谱仪(Matrix Assisted Laser Desorption Ionization-time of Flight Mass Spectrometry,MALDI-TOF MS)、16S rRNA测序法对分离菌株进行鉴定。铜绿假单胞菌的耐药性实验应用微生物全自动鉴定及药敏系统检测,采用16S rRNA基因序列测序构建系统发育树,MALDI-TOF MS进行同源性分析。结果表明,VITEK-2、MALDI-TOF MS、16S rRNA鉴定结果与常规方法分离的24株阳性菌株鉴定结果100%相符。耐药性结果表明,24株铜绿假单胞菌中2株为耐药菌株,分别是5-B-1,7-C-5,耐药率为8.3%,说明水源性菌株的耐药水平总体偏低。质谱结果表明来自同一地区的阳性菌株亲缘关系较近;16S rRNA系统发育表明铜绿假单胞菌分离株与地域不存在明显的相关性,但同一来源的铜绿假单胞菌属于同一簇,其来源主要为水源。该研究为桶装水中铜绿假单胞菌的污染溯源积累了数据,为进一步研究菌种污染溯源提供理论依据。 展开更多
关键词 铜绿假单胞菌 耐药分析 基质辅助激光解吸电离-飞行时间质谱 16S rRNA 同源性分析
下载PDF
基质辅助激光解吸电离飞行时间质谱自建库鉴定临床常见致病丝状真菌的研究
18
作者 张璐 赵蓉芬 +4 位作者 孙艳霞 Sde Hoog Jos Houbraken 邓淑文 张虹 《广西医科大学学报》 CAS 2024年第4期500-507,共8页
目的:评估基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)技术鉴定临床常见致病丝状真菌的准确性。方法:采用AUTOF MS1000质谱系统,在原有商业参考库的基础上,增补构建自建数据库,采用125株临床分离菌株对自建库进行验证。结果:自建... 目的:评估基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)技术鉴定临床常见致病丝状真菌的准确性。方法:采用AUTOF MS1000质谱系统,在原有商业参考库的基础上,增补构建自建数据库,采用125株临床分离菌株对自建库进行验证。结果:自建库新增菌株包括:皮肤癣菌3个属15种菌种,共76株;曲霉属30个菌种,共75株。以已有商业数据库加自建数据库为比对标准,125株临床分离菌株属水平鉴定率100%,种水平鉴定率达80.8%;以分子鉴定结果为金标准,正确鉴定率94.1%。其中,69株皮肤癣菌的种水平鉴定率为79.7%,正确鉴定率92.7%;56株曲霉菌种水平鉴定率为82.1%,正确鉴定率95.6%;错误鉴定6株,集中在须癣毛癣菌复合体(T.mentagrophytes series)菌种趾间毛癣菌/须癣毛癣菌/昆可努发癣菌(T.interdigitale/T.mentagrophytes/T.quinckeanum)交叉识别及Sect.Nigri中黑曲霉(A.niger)与塔宾曲霉(A.tubingensis)交叉识别。结论:通过补充完善自建库可提高MALDI-TOF MS鉴定丝状真菌的准确率;同时,参考数据库及时扩展和更新,以确保MALDI-TOF MS准确鉴定真菌菌种的能力。 展开更多
关键词 基质辅助激光解吸电离飞行时间质谱 自建库 皮肤癣菌 曲霉
下载PDF
Autof ms 1000与MALDI Biotyper对临床常见丝状病原真菌鉴定的比较分析
19
作者 张华 蔡克亚 +7 位作者 张宏兵 石媛漾 杜明威 封松利 刘美丽 廖万清 赵高岭 潘炜华 《广西医科大学学报》 CAS 2024年第2期270-275,共6页
目的:研究比较两种基质辅助激光解吸电离飞行时间质谱仪(Autof ms 1000与MALDI Biotyper)对临床常见丝状病原真菌鉴定的准确性和效率。方法:共纳入32株丝状病原真菌标准菌株和120株临床分离菌株,按照标准操作方法分别用Autof ms 1000与M... 目的:研究比较两种基质辅助激光解吸电离飞行时间质谱仪(Autof ms 1000与MALDI Biotyper)对临床常见丝状病原真菌鉴定的准确性和效率。方法:共纳入32株丝状病原真菌标准菌株和120株临床分离菌株,按照标准操作方法分别用Autof ms 1000与MALDI Biotyper对相关菌株进行鉴定,对相关结果及测序分子鉴定结果进行对比分析。结果:在种水平上,Autof ms 1000质谱仪共检出140株丝状病原真菌,检出正确率为92.1%(140/152),其中126株分值在9.0以上,2株出现错误鉴定,误鉴定比例为1.3%(2/152);MALDI Biotyper质谱仪共正确检出98株,检出正确率为64.4%,2.0分以上的菌株47株,仅3株鉴定分值大于2.3分,7株出现误鉴定。结论:Autof ms 1000与MALDI Biotyper这两种质谱鉴定系统均能用于临床常见丝状病原真菌的快速鉴定,而Autof ms 1000质谱仪更具优势。 展开更多
关键词 丝状病原真菌 基质辅助激光解吸电离飞行时间质谱仪 质谱
下载PDF
运用基质辅助激光解吸电离飞行时间质谱技术分析分枝杆菌液体培养管污染菌菌群特征
20
作者 蓝吉慧 唐柳生 +2 位作者 黄葵 刘爱梅 董捷 《新发传染病电子杂志》 2024年第2期7-10,共4页
目的了解分枝杆菌液体培养时产生的污染菌菌群特征,分析产生污染的原因,寻找降低污染的方法。方法收集广西壮族自治区胸科医院2023年5月10日至8月25日送检的痰液和肺泡灌洗液(bronchoalveolar lavage fluid,BALF)标本进行分枝杆菌液体培... 目的了解分枝杆菌液体培养时产生的污染菌菌群特征,分析产生污染的原因,寻找降低污染的方法。方法收集广西壮族自治区胸科医院2023年5月10日至8月25日送检的痰液和肺泡灌洗液(bronchoalveolar lavage fluid,BALF)标本进行分枝杆菌液体培养,运用基质辅助激光解吸电离飞行时间质谱(matrix-assisted laser desorption/ionization time-of-flight mass spectrometry,MALDI-TOF MS)技术对分枝杆菌液体培养后产生的污染菌进行鉴定,将鉴定出的菌种进行统计归类,分析污染菌的菌群特征。结果6090份呼吸道标本中分枝杆菌阳性标本864份,培养阳性率14.19%(864/6090),污染标本71份,污染率为1.17%(71/6090)。71份污染标本中共分离出74株污染菌,主要菌属为芽孢杆菌和曲霉菌,分别占31.08%(23/74)和24.32%(18/74)。其中灌洗液标本1429份,培养出分枝杆菌阳性标本279份,培养阳性率19.52%(279/1429),污染13株,污染率0.91%(13/1429);痰标本4661份培养出分枝杆菌585株,培养阳性率12.55%(585/4661),污染标本58份,污染率1.24%(58/4661);两种标本培养的阳性率比较,差异有统计学意义(χ^(2)=43.68,P<0.05),污染率比较,差异无统计学意义(χ^(2)=1.06,P>0.05)。结论分枝杆菌液体培养时产生的污染菌菌群复杂,以芽孢杆菌、曲霉菌为主,因此,必须规范标本的采集和运送,采用有效的前处理方法,以达到降低液体培养污染率的目的。 展开更多
关键词 污染菌 分枝杆菌 基质辅助激光解吸电离飞行时间质谱
下载PDF