Introduction Single nucleotide polymorphisms (SNPs) are the most abundant DNA markers in the human genome occurring at a frequency of one in every 500--1000 nucleotides. A variety of methods have been used for the ...Introduction Single nucleotide polymorphisms (SNPs) are the most abundant DNA markers in the human genome occurring at a frequency of one in every 500--1000 nucleotides. A variety of methods have been used for the analysis of single nucleotide polymorphisms, including restriction fragment length polymorphism (RFLP), direct sequencing by using laser-induced fluorescence detectionTM, fluorescence energy transfer, MALDI-TOF MS combined with primer extension or invasive cleavage, and fluorescence polarization. During the past two decades, mass spectrometry has become a very popular tool in the analysis of biomolecules and is perfectly suited to the analysis of single nucleotide polymorphisms (SNPs) due to its speed, low cost, and accuracy. In this work, we used MALDI TOF mass spectrometry to detect the fragments of restriction endonuclease hydrolysis of PCR products flanking a SNP located at paraoxonase 1(Q192R). Compared with electrophoresis, this method requires less time of analysis and possess a higher accuracy.展开更多
A novel sample preparation method of matrix-assisted laser desorption/ionization mass spectrometry for polystyrene was reported. Compared to the conventional dried-droplet method, the efficiency of ionization and sign...A novel sample preparation method of matrix-assisted laser desorption/ionization mass spectrometry for polystyrene was reported. Compared to the conventional dried-droplet method, the efficiency of ionization and signal intensity of mass spectra were improved. The mechanism was also analyzed.展开更多
Matrix-assisted Laser Desorption/Ionization with Time-of-flight Mass Spectrometry (MALDI-TOFMS) was investigated as a method for the rapid identifica-tion of species. Current demand in microbial identi-fication is how...Matrix-assisted Laser Desorption/Ionization with Time-of-flight Mass Spectrometry (MALDI-TOFMS) was investigated as a method for the rapid identifica-tion of species. Current demand in microbial identi-fication is how to compare unknown strains to the known one quickly, semi-automatically and accurately. In this paper, we present a software tool that allows flexibly microbial matching in a user-friendly way, by letting the users to customize comparison parameters including: in vitro transcription enzyme, mass tolerance,minimum fragment length, intensity threshold and corresponding weights. We provide three spectral scoring functions to compute the affin-ity between the species. Therefore, the precision of microbial comparison increases. To test and verify this tool, we employed experimental spectral data based on MALDI-TOFMS and the gene sequences of E.coli and Salmonella. This software is written in Java for cross-platform intention.展开更多
Background Recently, due to the rapid development of proteomic techniques, great advance has been made in many scientific fields. We aimed to use magnetic beads (liquid chip) based matrix-assisted laser desorption/i...Background Recently, due to the rapid development of proteomic techniques, great advance has been made in many scientific fields. We aimed to use magnetic beads (liquid chip) based matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) technology to screen distinctive biomarkers for lung adenocarcinoma (adCA), and to establish the diagnostic protein profiles. Methods Using weak cation exchange magnetic beads (MB-WCX) to isolate and purify low molecular weight proteins from sera of 35 lung adCA, 46 benign lung diseases (BLDs) and 44 healthy individuals. The resulting spectra gained by anchor chip-MALDI-TOF-MS were analyzed by ClinProTools and a pattern recognition genetic algorithm (GA). Results In the working mass range of 800-10 000 Da, 99 distinctive peaks were resolved in lung adCA versus BLDs, while 101 peaks were resolved in lung adCA versus healthy persons. The profile gained by GA that could distinguish adCA from BLDs was comprised of 4053.88, 4209.57 and 3883.33 Da with sensitivity of 80%, specificity of 93%, while that could separate adCA from healthy control was comprised of 2951.83 Da and 4209.73 Da with sensitivity of 94%, specificity of 95%. The sensitivity provided by carcinoembryonic antigen (CEA) in this experiment was significantly lower than our discriminatory profiles (P 〈0.005). We further identified a eukaryotic peptide chain release factor GTP-binding subunit (eRF3b) (4209 Da) and a complement C3f (1865 Da) that may serve as candidate biomarkers for lung adCA. Conclusion Magnetic beads based MALDI-TOF-MS technology can rapidly and effectively screen distinctive proteins/polypeptides from sera of lung adCA patients and controls, which has potential value for establishing a new diagnostic method for lung adCA.展开更多
Native and methyl-esterified sialylated glycans were analyzed with 2,4,6-trihydroxyacetophenone(THAP)and 2,5-dihydroxybenzoic acid(DHB)as matrix by a matrix-assisted laser desorption/ionization time-of-flight mass...Native and methyl-esterified sialylated glycans were analyzed with 2,4,6-trihydroxyacetophenone(THAP)and 2,5-dihydroxybenzoic acid(DHB)as matrix by a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer(MALDI-TOF MS).High quality negative-ion spectra of commercial sialylated glycan were obtained with THAP as matrix.Detection limit of the glycan was less than 0.1 pmol.After methyl esterification of sialic acid(SA)residue,sialylated glycans were detected sensitively in the positive-ion mode using DHB as matrix.Neutral and sialylated glycans from the mixture of asialofetuin and fetuin were methylesterified and simultaneously recognized in one manipulation.Methyl esterification of SA residue offers a convenient and sensitive way to identify the structure of N-linked glycans for glycan profiling.展开更多
基质辅助激光解吸电离飞行时间质谱(matrix assisted laser desorption ionization time of flight mass spectrometry,MALDI-TOF MS)作为近年来发展的新型食源性致病菌鉴定技术,具有灵敏、准确、检测速度快等优点,该技术为食品病原微...基质辅助激光解吸电离飞行时间质谱(matrix assisted laser desorption ionization time of flight mass spectrometry,MALDI-TOF MS)作为近年来发展的新型食源性致病菌鉴定技术,具有灵敏、准确、检测速度快等优点,该技术为食品病原微生物靶标性监测和食品安全事件应急检验提供了一种高效的鉴别技术参考,在保障民众生命健康和经济社会发展上发挥了重要作用。本文检索了近年来国内外MALDI-TOF MS技术在食源性致病菌检测中的相关研究案例,简要综述了MALDI-TOF MS检测原理、工作流程,影响鉴定结果的主要因素,介绍了MALDI-TOF MS技术应用于食源性致病菌检测中的实际案例,在此基础上分别从参考菌株数据库建设、标准化程序规范等方面对MALDI-TOF MS技术在食源性致病菌检测领域的未来研究方向进行展望,以期为后续食品安全检测及快速监管食源性致病菌污染提供技术支持。展开更多
文摘Introduction Single nucleotide polymorphisms (SNPs) are the most abundant DNA markers in the human genome occurring at a frequency of one in every 500--1000 nucleotides. A variety of methods have been used for the analysis of single nucleotide polymorphisms, including restriction fragment length polymorphism (RFLP), direct sequencing by using laser-induced fluorescence detectionTM, fluorescence energy transfer, MALDI-TOF MS combined with primer extension or invasive cleavage, and fluorescence polarization. During the past two decades, mass spectrometry has become a very popular tool in the analysis of biomolecules and is perfectly suited to the analysis of single nucleotide polymorphisms (SNPs) due to its speed, low cost, and accuracy. In this work, we used MALDI TOF mass spectrometry to detect the fragments of restriction endonuclease hydrolysis of PCR products flanking a SNP located at paraoxonase 1(Q192R). Compared with electrophoresis, this method requires less time of analysis and possess a higher accuracy.
文摘A novel sample preparation method of matrix-assisted laser desorption/ionization mass spectrometry for polystyrene was reported. Compared to the conventional dried-droplet method, the efficiency of ionization and signal intensity of mass spectra were improved. The mechanism was also analyzed.
文摘Matrix-assisted Laser Desorption/Ionization with Time-of-flight Mass Spectrometry (MALDI-TOFMS) was investigated as a method for the rapid identifica-tion of species. Current demand in microbial identi-fication is how to compare unknown strains to the known one quickly, semi-automatically and accurately. In this paper, we present a software tool that allows flexibly microbial matching in a user-friendly way, by letting the users to customize comparison parameters including: in vitro transcription enzyme, mass tolerance,minimum fragment length, intensity threshold and corresponding weights. We provide three spectral scoring functions to compute the affin-ity between the species. Therefore, the precision of microbial comparison increases. To test and verify this tool, we employed experimental spectral data based on MALDI-TOFMS and the gene sequences of E.coli and Salmonella. This software is written in Java for cross-platform intention.
基金This work was supported by grants from the National Natural Science Foundation of China (No. 30570795) and Program for New Century Excellent Talents in University (No. NECT-06-0845) and the Program in Science and Technology of Xi'an, Shaanxi Province (No. S F08009(1)).Acknowledgement: We are grateful to HU Xiao-hui for the technical guidance.
文摘Background Recently, due to the rapid development of proteomic techniques, great advance has been made in many scientific fields. We aimed to use magnetic beads (liquid chip) based matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) technology to screen distinctive biomarkers for lung adenocarcinoma (adCA), and to establish the diagnostic protein profiles. Methods Using weak cation exchange magnetic beads (MB-WCX) to isolate and purify low molecular weight proteins from sera of 35 lung adCA, 46 benign lung diseases (BLDs) and 44 healthy individuals. The resulting spectra gained by anchor chip-MALDI-TOF-MS were analyzed by ClinProTools and a pattern recognition genetic algorithm (GA). Results In the working mass range of 800-10 000 Da, 99 distinctive peaks were resolved in lung adCA versus BLDs, while 101 peaks were resolved in lung adCA versus healthy persons. The profile gained by GA that could distinguish adCA from BLDs was comprised of 4053.88, 4209.57 and 3883.33 Da with sensitivity of 80%, specificity of 93%, while that could separate adCA from healthy control was comprised of 2951.83 Da and 4209.73 Da with sensitivity of 94%, specificity of 95%. The sensitivity provided by carcinoembryonic antigen (CEA) in this experiment was significantly lower than our discriminatory profiles (P 〈0.005). We further identified a eukaryotic peptide chain release factor GTP-binding subunit (eRF3b) (4209 Da) and a complement C3f (1865 Da) that may serve as candidate biomarkers for lung adCA. Conclusion Magnetic beads based MALDI-TOF-MS technology can rapidly and effectively screen distinctive proteins/polypeptides from sera of lung adCA patients and controls, which has potential value for establishing a new diagnostic method for lung adCA.
基金Supported by the National Natural Science Foundation of China(30800193)Grant from Centre for International Mobility(CIMO),Finland
文摘Native and methyl-esterified sialylated glycans were analyzed with 2,4,6-trihydroxyacetophenone(THAP)and 2,5-dihydroxybenzoic acid(DHB)as matrix by a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer(MALDI-TOF MS).High quality negative-ion spectra of commercial sialylated glycan were obtained with THAP as matrix.Detection limit of the glycan was less than 0.1 pmol.After methyl esterification of sialic acid(SA)residue,sialylated glycans were detected sensitively in the positive-ion mode using DHB as matrix.Neutral and sialylated glycans from the mixture of asialofetuin and fetuin were methylesterified and simultaneously recognized in one manipulation.Methyl esterification of SA residue offers a convenient and sensitive way to identify the structure of N-linked glycans for glycan profiling.
文摘基质辅助激光解吸电离飞行时间质谱(matrix assisted laser desorption ionization time of flight mass spectrometry,MALDI-TOF MS)作为近年来发展的新型食源性致病菌鉴定技术,具有灵敏、准确、检测速度快等优点,该技术为食品病原微生物靶标性监测和食品安全事件应急检验提供了一种高效的鉴别技术参考,在保障民众生命健康和经济社会发展上发挥了重要作用。本文检索了近年来国内外MALDI-TOF MS技术在食源性致病菌检测中的相关研究案例,简要综述了MALDI-TOF MS检测原理、工作流程,影响鉴定结果的主要因素,介绍了MALDI-TOF MS技术应用于食源性致病菌检测中的实际案例,在此基础上分别从参考菌株数据库建设、标准化程序规范等方面对MALDI-TOF MS技术在食源性致病菌检测领域的未来研究方向进行展望,以期为后续食品安全检测及快速监管食源性致病菌污染提供技术支持。