Light pen coordinate measuring system(LPCMS)is a kind of portable coordinate measuring technique based on vision metrology.In classical LPCMS,the measuring range is limited to the camera’s field of view.To overcome t...Light pen coordinate measuring system(LPCMS)is a kind of portable coordinate measuring technique based on vision metrology.In classical LPCMS,the measuring range is limited to the camera’s field of view.To overcome this defect,a new LPCMS is designed in this paper to fulfil whole space coordinate measurement.The camera is installed on a turntable instead of a tripod,so that the camera can rotate to track the movement of the light pen.The new system can be applied to large scale onsite measurement,and therefore it notably extends the application of LPCMS.To guarantee the accuracy of the new system,a method to calibrate the parameters of the tracking turntable is also proposed.Fixing the light pen at a stationary position,and changing the azimuth angles of the turntable’s two shafts,so that the camera can capture the images of the light pen from different view angles.According to the invariant spatial relationship between the camera and the pedestal of the tracking turntable,a system of nonlinear equations can be established to solve the parameters of the turntable.Experimental results show that the whole space coordinate measuring accuracy of the new system can reach 0.25 mm within 10 m.It can be concluded that the newly designed system can significantly expand the measuring range of LPCMS without losing too much accuracy.展开更多
This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transforma...This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transformation matrix and an extended rotating coordinate transformation matrix are investigated considering the influence of the fifth harmonic space on fault-tolerant control. These mathematical models are further analyzed in the fundamental space and the fifth harmonic space after the fault and to eliminate the coupling between the d-q axis voltage equation in the fundamental wave space and the d-q axis voltage equation in the fifth harmonic space, a secondary rotation coordinate transformation matrix is proposed. To achieve the purpose of reducing torque ripple, the fault-tolerant control method proposed in this paper not only takes the minimum copper loss as the constraint condition, but also injects the fifth harmonic current. The experimental result of current and torque is used to verify the accuracy of fault-tolerant control.展开更多
In this paper, a criterion of decomposable element in V(2) is obtained , i. e.,Z = p(i, j)eij is decomposable if and only if its adjacent coordinate matrices are all "row 1≤i≤j≤ncommute" equivalent.
Command Decision Simulation (CDS) is not only an important and difficult issue in the field of simulation, but also a technique issue to be tackled in the course of collective Modeling and Simulation in Joint Operat...Command Decision Simulation (CDS) is not only an important and difficult issue in the field of simulation, but also a technique issue to be tackled in the course of collective Modeling and Simulation in Joint Operations Experiment Center. CDS can give support to all kinds of simulation. Using computer to realize the Blue side's command deci- sion automatic execution in the operation training simulation system can improve training effect. Using computer to realize the lower level command unit's automatic command deci- sion can help to reduce the number of controllers and release them from heavy work. It can also enlarge simulation scale and increase the freedom of the simulation entity especially the command entity, thus enhance the authenticity and credibility of the simulation. Ac- cording to the command decision structure and the Joint Intention Theory, the thesis puts forward the method of making use of Coordination Matrix (CM) to realizing cooperation among the entities in CDS and constructs the calculation sketch of Task Execution, Task Monitoring and Task Replanning. At the same time, the thesis brings forward the CDS structure vision based on Partial Global Planning(PGP). As CM is an indispensable part of combat simulation, the theory and the method of CDS will become an important part for the theory of Combat Simulation.展开更多
基金State Administration of Science,Technology and Industry for the National Defense(No.JSJL2014206B001)。
文摘Light pen coordinate measuring system(LPCMS)is a kind of portable coordinate measuring technique based on vision metrology.In classical LPCMS,the measuring range is limited to the camera’s field of view.To overcome this defect,a new LPCMS is designed in this paper to fulfil whole space coordinate measurement.The camera is installed on a turntable instead of a tripod,so that the camera can rotate to track the movement of the light pen.The new system can be applied to large scale onsite measurement,and therefore it notably extends the application of LPCMS.To guarantee the accuracy of the new system,a method to calibrate the parameters of the tracking turntable is also proposed.Fixing the light pen at a stationary position,and changing the azimuth angles of the turntable’s two shafts,so that the camera can capture the images of the light pen from different view angles.According to the invariant spatial relationship between the camera and the pedestal of the tracking turntable,a system of nonlinear equations can be established to solve the parameters of the turntable.Experimental results show that the whole space coordinate measuring accuracy of the new system can reach 0.25 mm within 10 m.It can be concluded that the newly designed system can significantly expand the measuring range of LPCMS without losing too much accuracy.
基金supported by the National Natural Science Foundation of China under Grant 61603263。
文摘This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transformation matrix and an extended rotating coordinate transformation matrix are investigated considering the influence of the fifth harmonic space on fault-tolerant control. These mathematical models are further analyzed in the fundamental space and the fifth harmonic space after the fault and to eliminate the coupling between the d-q axis voltage equation in the fundamental wave space and the d-q axis voltage equation in the fifth harmonic space, a secondary rotation coordinate transformation matrix is proposed. To achieve the purpose of reducing torque ripple, the fault-tolerant control method proposed in this paper not only takes the minimum copper loss as the constraint condition, but also injects the fifth harmonic current. The experimental result of current and torque is used to verify the accuracy of fault-tolerant control.
文摘In this paper, a criterion of decomposable element in V(2) is obtained , i. e.,Z = p(i, j)eij is decomposable if and only if its adjacent coordinate matrices are all "row 1≤i≤j≤ncommute" equivalent.
基金This project is supported by National Natnral Science Foundation of China(40601059).
文摘Command Decision Simulation (CDS) is not only an important and difficult issue in the field of simulation, but also a technique issue to be tackled in the course of collective Modeling and Simulation in Joint Operations Experiment Center. CDS can give support to all kinds of simulation. Using computer to realize the Blue side's command deci- sion automatic execution in the operation training simulation system can improve training effect. Using computer to realize the lower level command unit's automatic command deci- sion can help to reduce the number of controllers and release them from heavy work. It can also enlarge simulation scale and increase the freedom of the simulation entity especially the command entity, thus enhance the authenticity and credibility of the simulation. Ac- cording to the command decision structure and the Joint Intention Theory, the thesis puts forward the method of making use of Coordination Matrix (CM) to realizing cooperation among the entities in CDS and constructs the calculation sketch of Task Execution, Task Monitoring and Task Replanning. At the same time, the thesis brings forward the CDS structure vision based on Partial Global Planning(PGP). As CM is an indispensable part of combat simulation, the theory and the method of CDS will become an important part for the theory of Combat Simulation.