Matrix solid-phase dispersion(MSPD) was developed for the extraction of four alkaloids, including aconitine, mesaconitine, hypaconitine and deoxyaconitine, from the roots ofAconitum kusnezoffii Reichb. The determina...Matrix solid-phase dispersion(MSPD) was developed for the extraction of four alkaloids, including aconitine, mesaconitine, hypaconitine and deoxyaconitine, from the roots ofAconitum kusnezoffii Reichb. The determination of the analyte was carried out by high performance liquid chromatography with UV detection. The alkaline alumina was used as sorbent. The mixture of acetonitrile and water was used as elution solvent. Several extraction parameters, such as type of sorbent, the ratio of sample to solid support material, type of the elution solvent and the volume of the elution solvent were tested. Mean recoveries ranged from 93.16% to 102.73%, with relative standard deviations from 0.27% to 4.17%. With the extraction efficiency and time expenditure taken into account, MSPD extraction should be a comparatively good method.展开更多
A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet de...A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.展开更多
以基质固相分散-气相色谱-串联质谱法(先将粉粹的竹笋样品经弗罗里硅土基质固相分散技术净化,然后用20 m L丙酮—正己烷溶液(1+2,v/v)淋洗,GC—MS/MS检测,外标法定量)检测竹笋中26种有机氯农药残留量。结果表明:26种有机氯农药在5...以基质固相分散-气相色谱-串联质谱法(先将粉粹的竹笋样品经弗罗里硅土基质固相分散技术净化,然后用20 m L丙酮—正己烷溶液(1+2,v/v)淋洗,GC—MS/MS检测,外标法定量)检测竹笋中26种有机氯农药残留量。结果表明:26种有机氯农药在5~200μg/m L范围内线性良好,相关系数均大于0.99。在0.01~0.1 mg/kg浓度范围内,26种目标物的平均加标回收率为81.1%~108.9%,相对标准偏差在3.3%~9.5%。该方法具有较好的准确度和精密度,各项技术指标均能满足竹笋中26种有机氯农药的检测需要。展开更多
An efficient method is provided to detect simultaneously some important veterinary drugs from different classes in highly complex animal tissue matrix. This method using matrix solid-phase dispersion (MSPD) and high p...An efficient method is provided to detect simultaneously some important veterinary drugs from different classes in highly complex animal tissue matrix. This method using matrix solid-phase dispersion (MSPD) and high performance liquid chromatography (HPLC) with diode array detection (DAD) is developed to effectively determine two fiuoroquinolones (enoxacin and lomefioxacin), two sulfonamides (sulfanilamide and sulfamethoxazole) and one tetracycline (tetracycline) simultaneously in porcine tissues. In the process, MSPD methodology was used to treat samples, washed by n-hexane to remove lipid, eluted the analytes with acetonitrile–dichloromethane (1:1, v/v). Solvent acetonitrile and solvent acetic acid (0.1%) were combined in a gradient. HPLC–DAD analysis of the tissue samples was performed within 15 min at a fiow rate of 1.0 mL/min. The results showed that a recovery at 0.1, 0.5 and 1.0 mg/g fortification levels ranged from 80.6% to 99.2% with satisfactory relative standard deviations (RSDs) (below 6.1%, nfi3) and the limits of quantitation (LOQ) ranged from 7 mg/kg to 34 mg/kg in porcine tissues. Utilization of the method in successfully simultaneous analysis of porcine tissue incurred with veterinary drug multiresidues is described.展开更多
Chlorinated paraffins(SCCPs) are widely used worldwide, and they can be released into the environment during their production, transport, usage and disposal, which pose potential risks for human health. In this work...Chlorinated paraffins(SCCPs) are widely used worldwide, and they can be released into the environment during their production, transport, usage and disposal, which pose potential risks for human health. In this work, an efficient, reliable and rapid pretreatment method based on matrix solid-phase dispersion(MSPD) was developed for the analysis of short-chain CPs(SCCPs) in human placenta by gas chromatograph-electron capture negative ion low-resolution mass spectrometry(GC-ECNI-LRMS) and gas chromatography–quadrupole time-of-flight mass spectrometry(GC–QTOF-HRMS). The MSPD-relevant parameters including dispersing sorbent,sample-to-sorbent mass ratio, and elution solvent were optimized using the orthogonal test.Silica gel was found to be the optimal dispersing sorbent among the selected matrices. Under the optimal conditions, 44% acidic silica gel can be used as the co-sorbent to remove lipid and eluted by the mixture of hexane and dichloromethane(7:3, V/V). The spiked recoveries of the optimized method were 77.4% and 91.4% for analyzing SCCPs in human placenta by GC-ECNI-LRMS and GC–QTOF-HRMS, and the corresponding relative standard deviations were10.2% and 5.6%, respectively. The method detection limit for the total SCCPs was 36.8 ng/g(dry weight, dw) and 19.2 ng/g(dw) as measured by GC-ECNI-LRMS and GC–QTOF-HRMS,respectively. The concentrations of SCCPs in four human placentas were in the range of展开更多
基金Supported by the Projects in the National Science & Technology Pillar Program During the Eleventh Five-Year Plan Period of China(No 2006BAI14B01)
文摘Matrix solid-phase dispersion(MSPD) was developed for the extraction of four alkaloids, including aconitine, mesaconitine, hypaconitine and deoxyaconitine, from the roots ofAconitum kusnezoffii Reichb. The determination of the analyte was carried out by high performance liquid chromatography with UV detection. The alkaline alumina was used as sorbent. The mixture of acetonitrile and water was used as elution solvent. Several extraction parameters, such as type of sorbent, the ratio of sample to solid support material, type of the elution solvent and the volume of the elution solvent were tested. Mean recoveries ranged from 93.16% to 102.73%, with relative standard deviations from 0.27% to 4.17%. With the extraction efficiency and time expenditure taken into account, MSPD extraction should be a comparatively good method.
基金This research was supported by Special Research Fund for Young Doctors of Qiqihar Medical University(QMSI2020B-03,hosted by Wenjing Li).
文摘A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.
文摘以基质固相分散-气相色谱-串联质谱法(先将粉粹的竹笋样品经弗罗里硅土基质固相分散技术净化,然后用20 m L丙酮—正己烷溶液(1+2,v/v)淋洗,GC—MS/MS检测,外标法定量)检测竹笋中26种有机氯农药残留量。结果表明:26种有机氯农药在5~200μg/m L范围内线性良好,相关系数均大于0.99。在0.01~0.1 mg/kg浓度范围内,26种目标物的平均加标回收率为81.1%~108.9%,相对标准偏差在3.3%~9.5%。该方法具有较好的准确度和精密度,各项技术指标均能满足竹笋中26种有机氯农药的检测需要。
基金supported by the Natural Science Foundation of Shaanxi Province (No. 2009jm4002-1)
文摘An efficient method is provided to detect simultaneously some important veterinary drugs from different classes in highly complex animal tissue matrix. This method using matrix solid-phase dispersion (MSPD) and high performance liquid chromatography (HPLC) with diode array detection (DAD) is developed to effectively determine two fiuoroquinolones (enoxacin and lomefioxacin), two sulfonamides (sulfanilamide and sulfamethoxazole) and one tetracycline (tetracycline) simultaneously in porcine tissues. In the process, MSPD methodology was used to treat samples, washed by n-hexane to remove lipid, eluted the analytes with acetonitrile–dichloromethane (1:1, v/v). Solvent acetonitrile and solvent acetic acid (0.1%) were combined in a gradient. HPLC–DAD analysis of the tissue samples was performed within 15 min at a fiow rate of 1.0 mL/min. The results showed that a recovery at 0.1, 0.5 and 1.0 mg/g fortification levels ranged from 80.6% to 99.2% with satisfactory relative standard deviations (RSDs) (below 6.1%, nfi3) and the limits of quantitation (LOQ) ranged from 7 mg/kg to 34 mg/kg in porcine tissues. Utilization of the method in successfully simultaneous analysis of porcine tissue incurred with veterinary drug multiresidues is described.
基金supported by the National Natural Science Foundation of China(Nos.21625702,21337002,21621064)the National Basic Research Program of China(No.2015CB453102)the Strategic Priority Research Program of the Chinese Academy of Science(No.XDB14010400)for the joint financial support
文摘Chlorinated paraffins(SCCPs) are widely used worldwide, and they can be released into the environment during their production, transport, usage and disposal, which pose potential risks for human health. In this work, an efficient, reliable and rapid pretreatment method based on matrix solid-phase dispersion(MSPD) was developed for the analysis of short-chain CPs(SCCPs) in human placenta by gas chromatograph-electron capture negative ion low-resolution mass spectrometry(GC-ECNI-LRMS) and gas chromatography–quadrupole time-of-flight mass spectrometry(GC–QTOF-HRMS). The MSPD-relevant parameters including dispersing sorbent,sample-to-sorbent mass ratio, and elution solvent were optimized using the orthogonal test.Silica gel was found to be the optimal dispersing sorbent among the selected matrices. Under the optimal conditions, 44% acidic silica gel can be used as the co-sorbent to remove lipid and eluted by the mixture of hexane and dichloromethane(7:3, V/V). The spiked recoveries of the optimized method were 77.4% and 91.4% for analyzing SCCPs in human placenta by GC-ECNI-LRMS and GC–QTOF-HRMS, and the corresponding relative standard deviations were10.2% and 5.6%, respectively. The method detection limit for the total SCCPs was 36.8 ng/g(dry weight, dw) and 19.2 ng/g(dw) as measured by GC-ECNI-LRMS and GC–QTOF-HRMS,respectively. The concentrations of SCCPs in four human placentas were in the range of