期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review 被引量:13
1
作者 Alberto Domínguez-Vicent Cari Pérez-Vives +2 位作者 Teresa Ferrer-Blasco Santiago García-Lázaro Robert Montés-Micó 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第7期1057-1065,共9页
We have reviewed a set of recently published studies that compared the anterior chamber depth(ACD) and/or white-to-white(WTW) distance obtained by means of different measuring devices.Since some of those studies r... We have reviewed a set of recently published studies that compared the anterior chamber depth(ACD) and/or white-to-white(WTW) distance obtained by means of different measuring devices.Since some of those studies reached contradictory conclusions regarding device interchangeability,this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance,among these devices:A-scan,ultrasound biomicroscopy,Orbscan and Orbscan Ⅱ(Bausch&Lomb Surgical Inc.,San Dimas,California,USA),Pentacam and Pentacam HR(Oculus,Wetzlar,Germany),Galilei(Ziemer,Switzerland),Visante optical coherence tomography(Visante OCT,Carl Zeiss Meditec Inc.,Dublin,California,USA),lOLMaster(Carl Zeiss Meditec,Jena,Germany),and Lenstar LS 900/Biograph(Haag-Streit AG,Koeniz,Switzerland/Alcon Laboratories Inc.,Ft Worth,Texas,USA). 展开更多
关键词 anterior camber depth measurement white to white measurement device interchangeability anterior chamber eye
下载PDF
Measurement Device Independent Quantum Key Distribution Based on Orbital Angular Momentum under Parametric Light Source
2
作者 Meng Wang Hong Lai Lei Pan 《Computers, Materials & Continua》 SCIE EI 2020年第4期369-387,共19页
On the one hand,existing measurement device independent quantum key distribution(MDI-QKD)protocols have usually adopted single photon source(SPS)and weak coherent photon(WCP),however,these protocols have suffered from... On the one hand,existing measurement device independent quantum key distribution(MDI-QKD)protocols have usually adopted single photon source(SPS)and weak coherent photon(WCP),however,these protocols have suffered from multi-photon problem brought from photon splitter number attacks.On the other hand,the orbital angular momentum(OAM)-MDI-QKD protocol does not need to compare and adjust the reference frame,solving the dependency of the base in the MDI-QKD protocol.Given that,we propose the OAM-MDI-QKD protocol based on the parametric light sources which mainly include single-photon-added-coherent(SPACS)and heralded single-photon sources(HSPS).Due to the stability of OAM and the participation of parametric light sources,the performance of MDI-QKD protocol gradually approaches the ideal situation.Numerical simulation shows that compared with WCP scheme,HSPS and SPACS schemes have increased the maximum secure transmission distance by 30 km and 40 km respectively. 展开更多
关键词 measurement device independent orbital angular momentum parametric light sources single-photon-added coherent state heralded single-photon sources
下载PDF
The Research and Application of the Anti-Interference Techniques of Electronic Device in Power System 被引量:1
3
作者 吴维宁 张文亮 +1 位作者 吴峡 李建建 《Electricity》 2001年第4期40-43,共4页
This paper presents the study and application of the electronic device anti-interference techniques underhigh voltage and/or heavy current electro-magnetic circumstance in power system.[
关键词 electric power system electronic measurement and/or control device anti-interference measures
下载PDF
ONLINE GRINDING WHEEL WEAR COMPENSATION BY IMAGE BASED MEASURING TECHNIQUES 被引量:10
4
作者 WAN Daping HU Dejin +1 位作者 WU Qi ZHANG Yonghong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第4期509-513,共5页
Automatic compensation of grinding wheel wear in dry grinding is accomplished by an image based online measurement method. A kind of PC-based charge-coupled device image recognition system is schemed out, which detect... Automatic compensation of grinding wheel wear in dry grinding is accomplished by an image based online measurement method. A kind of PC-based charge-coupled device image recognition system is schemed out, which detects the topography changes of the grinding wheel surface. Profile data, which corresponds to the wear and the topography, is measured by using a digital image processing method. The grinding wheel wear is evalualed by analyzing the position deviation of the grinding wheel edge. The online wear compensation is achieved according to the measure results. The precise detection and automatic compensation system is integrated into an open structure CNC curve grinding machine. A practical application is carried out to fulfil the precision curve grinding. The experimental results confirm the benefits of the proposed techniques, and the online detection accuracy is less than 5 um. The grinding machine provides higher precision according to the in-process grinding wheel error compensation. 展开更多
关键词 Grinding wheel Wear Compensation Online measurement Charge-coupled device (CCD)
下载PDF
Loss-tolerant measurement device independent quantum key distribution with reference frame misalignment 被引量:1
5
作者 Jipeng Wang Zhenhua Li +6 位作者 Zhongqi Sun Tianqi Dou Wenxiu Qu Fen Zhou Yanxin Han Yuqing Huang Haiqiang Ma 《Chinese Optics Letters》 SCIE EI CAS CSCD 2022年第9期61-67,共7页
Reference frame independent and measurement device independent quantum key distribution(RFI-MDI-QKD)has the advantages of being immune to detector side loopholes and misalignment of the reference frame.However,several... Reference frame independent and measurement device independent quantum key distribution(RFI-MDI-QKD)has the advantages of being immune to detector side loopholes and misalignment of the reference frame.However,several former related research works are based on the unrealistic assumption of perfect source preparation.In this paper,we merge a loss-tolerant method into RFI-MDI-QKD to consider source flaws into key rate estimation and compare it with quantum coin method.Based on a reliable experimental scheme,the joint influence of both source flaws and reference frame misalignment is discussed with consideration of the finite-key effect.The results show that the loss-tolerant RFI-MDI-QKD protocol can reach longer key rate performance while considering the existence of source flaws in a real-world implementation. 展开更多
关键词 quantum key distribution source flaw measurement device independence
原文传递
Analysis of Optical Readout Sensitivity for Uncooled Infrared Detector 被引量:1
6
作者 程腾 张青川 +2 位作者 焦彬彬 陈大鹏 伍小平 《Chinese Physics Letters》 SCIE CAS CSCD 2009年第12期125-128,共4页
An optical readout uncooled infrared detector, employing a substrate-free focal plane array with pitch size 60μm, is established. The reflector deformation induced by the stress mismatching of the bi-layer structure ... An optical readout uncooled infrared detector, employing a substrate-free focal plane array with pitch size 60μm, is established. The reflector deformation induced by the stress mismatching of the bi-layer structure is discussed and, in turn, a universal solution to determine both the optical readout sensitivity and the optimal filter position is found. By applying this solution, the optical readout sensitivity for the ideal plane reflector could theoretically increase by 80% as compared with the conventional operation, and the sensitivity loss caused by the reflector deformation can also be reduced to a reasonable level. 展开更多
关键词 Electronics and devices Instrumentation and measurement Optics quantum optics and lasers
下载PDF
Electromechanical Behavior of Interdigitated SiO2 Cantilever Arrays
7
作者 管志强 罗刚 +1 位作者 MONTELIUS Lars 徐红星 《Chinese Physics Letters》 SCIE CAS CSCD 2010年第2期307-310,共4页
Bending and first flexural mode vibration behavior of electrostatic actuated nanometer-sized interdigitated cantilever arrays are characterized under vacuum conditions. The pull-in'' effect in dc driving and the har... Bending and first flexural mode vibration behavior of electrostatic actuated nanometer-sized interdigitated cantilever arrays are characterized under vacuum conditions. The pull-in'' effect in dc driving and the hard spring effect'' in ac driving are observed. A mass sensitivity of 20 fg is expected for our devices due to the ultra-small mass of the arm and relative high Q factor. The mass-spring lump model combined with Green's function method is used to fit the dc driving behaviors including the pull-in voltage. For the ac driving case, the polynomial expansion of the capacitive force is used in the model. The successfully fittings of the pull-in voltage and the hard spring effect prove that our simulation method could be used for guiding the geometrical design of cantilever-based sensors. 展开更多
关键词 Electronics and devices Instrumentation and measurement Condensed matter: structural mechanical & thermal Nanoscale science and low-D systems
下载PDF
Simulation of SET Operation in Phase-Change Random Access Memories with Heater Addition and Ring-Type Contactor for Low-Power Consumption by Finite Element Modeling
8
作者 龚岳峰 宋志棠 +2 位作者 凌云 刘燕 封松林 《Chinese Physics Letters》 SCIE CAS CSCD 2009年第11期227-230,共4页
A three-dimensional finite element model for phase change random access memory (PCRAM) is established for comprehensive electrical and thermal analysis during SET operation. The SET behaviours of the heater additio... A three-dimensional finite element model for phase change random access memory (PCRAM) is established for comprehensive electrical and thermal analysis during SET operation. The SET behaviours of the heater addition structure (HS) and the ring-type contact in bottom electrode (RIB) structure are compared with each other. There are two ways to reduce the RESET current, applying a high resistivity interracial layer and building a new device structure. The simulation resuIts indicate that the variation of SET current with different power reduction ways is little. This study takes the RESET and SET operation current into consideration, showing that the RIB structure PCRAM cell is suitable for future devices with high heat efficiency and high-density, due to its high heat efficiency in RESET operation. 展开更多
关键词 Electronics and devices Instrumentation and measurement Chemical physics and physical chemistry
下载PDF
Device for determining critical wind speed of stalk breaking to evaluate maize lodging resistance 被引量:3
9
作者 Jun Xue Bo Ming +3 位作者 Keru Wang Ruizhi Xie Peng Hou Shaokun Li 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2020年第5期1-7,共7页
The accurate evaluation of the lodging resistance of maize plants can provide a basis for the breeding of lodging-resistant cultivars and the regulation of cultivation measures.However,the traditional methods for eval... The accurate evaluation of the lodging resistance of maize plants can provide a basis for the breeding of lodging-resistant cultivars and the regulation of cultivation measures.However,the traditional methods for evaluating maize lodging resistance in terms of plant morphology and stalk mechanical strength have certain limitations.The objective of this research was to develop a device for determining the critical wind speed of maize stalk breaking.The device was equipped with a centrifugal fan to supply airflow and was powered by a frequency conversion motor.The frequency converter adjusted the motor speed and thus adjusted the wind speed.The wind speed decreased first and then increased with increasing height above the outlet of the device,and maximum wind speed can reach 40 m/s.This device was convenient for transportation in the field,has a low cost,and can quickly,accurately,and objectively determine the lodging resistance.Field tests showed that the device ran stably for a long time.The coefficient of variation of three repeated measurements was between 1.5%and 4.8%for four maize cultivars.The new device can measure the critical wind speed of maize lodging and identify the lodging resistance for different maize cultivars,cultivation practices,and plant health conditions,and can thus overcome barriers to measuring the maize lodging resistance under natural wind conditions. 展开更多
关键词 MAIZE stalk lodging critical wind speed TURBOFAN measuring device wind pressure
原文传递
Modeling, measurement and simulation of the disturbance torque generated via solar array drive assembly 被引量:7
10
作者 CHEN JiangPan CHENG Wei LI Ming 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2018年第4期587-603,共17页
The disturbance torque generated via solar array drive assembly(SADA) can significantly degrade the key performance of satellite.The discussed SADA is composed of a two-phase hybrid stepping motor and a set of two-sta... The disturbance torque generated via solar array drive assembly(SADA) can significantly degrade the key performance of satellite.The discussed SADA is composed of a two-phase hybrid stepping motor and a set of two-stage straight gear reducer. Firstly, the vibration equation of the two-phase hybrid stepping motor is established via simplifying and linearizing the electromagnetic torque.Secondly, based on the vibration equation established, the disturbance torque model of SADA is created via force analysis and force system simplification. Thirdly, for precisely ground measuring the disturbance torque aroused by SADA, a measurement system,including a strain micro-vibrations measurement platform(SMMP) and a set of gravity unloading device(GUD), is designed.Fourthly, the proposed disturbance torque model is validated by measuring and simulating the disturbance torque produced via SADA driving rigid load through GUD. The results indicate that, the proposed disturbance torque model holds the ability to describe the disturbance torque caused by SADA with high precision. Finally, the disturbance torque emitted by SADA driving a flexible load, designed to simulate solar array, is modeled and simulated via using fixed-interface mode synthesis method(FIMSM). All the conclusions drawn from this article do have a meaningful help for studying the disturbance torque produced by SADA driving solar array on orbit. 展开更多
关键词 solar array drive assembly(SADA) disturbance torque stepping motor strain micro-vibrations measurement platform(SMMP) gravity unloading device(GUD) fixed-interface mode synthesis method(FIMSM)
原文传递
Fertilizer sphericity measuring device based on equatorial and meridian circles
11
作者 Hongjian Zhang Junlin Mu +3 位作者 Shuangxi Liu Zhen Wang Guikun Chu Jinxing Wang 《Information Processing in Agriculture》 EI 2021年第1期52-63,共12页
Fertilizer sphericity is an important assessment index of appearance quality that affects the fertilization effect.A fertilizer sphericity measuring device based on machine vision was designed aimed at low precision a... Fertilizer sphericity is an important assessment index of appearance quality that affects the fertilization effect.A fertilizer sphericity measuring device based on machine vision was designed aimed at low precision and heavy workload of manual fertilizer measurement,and high cost and complicated operation of high precision measuring instruments.A fertilizer sphericity measuring method based on equatorial and meridian circles was proposed.The device works in an intermittent static acquisition mode to simultaneously obtain both top and side images of a single fertilizer.First,the method performs gamma correction on the top and side images of the single fertilizer,and uses the Canny operator to detect the edge of the image to obtain the equatorial and meridian circular contour images of the fertilizer.Second,based on the fertilizer equatorial and meridian circular contour,the Least Squares Circle method was used to evaluate the roundness of the single fertilizer.Finally,the average roundness value of the equatorial and meridian circles was used as the final sphericity value of the fertilizer.The sphericity measurement test was carried out on the same batch of compound,organic and biological fertilizers by using the sphericity measuring device.The fertilizer sphericity data were obtained by different measurement and evaluation methods.The variation coefficient was used to evaluate the difference in fertilizer sphericity measured by different sphericity measurement and evaluation methods.The results show that among the different measurement and evaluation methods,the coefficient of variation of fertilizer sphericity measured by the equatorial and meridian circle method was the smallest,and the coefficient of variation of sphericity measured by the Least Squares Circle method was the smallest and accurate.This study shows that the sphericity measuring device and method can accurately measure the fertilizer sphericity,and has a significant potential to facilitate fertilizer production and quality inspection. 展开更多
关键词 FERTILIZER SPHERICITY Equatorial and meridian circles Machine vision Measuring device Measuring method
原文传递
Automatic Determination of Water Hardness by Vector Colorimetry with Acid Chrome Blue K
12
作者 Su Gao Ming-Liang Ye +2 位作者 Rui Ma Ai-Rong Liu Hong-Wen Gao 《Journal of Analysis and Testing》 EI CSCD 2023年第2期157-162,共6页
Based on the Mg^(2+)complexation with acid chrome blue K(ACBK)at pH 10.2,an automatic system was designed to determine total hardness of water.The system consists of a vector colorimeter,a multi-channel sampling pump ... Based on the Mg^(2+)complexation with acid chrome blue K(ACBK)at pH 10.2,an automatic system was designed to determine total hardness of water.The system consists of a vector colorimeter,a multi-channel sampling pump and both reagents A and B.Two kinds of reagent solutions were prepared and used in this system,i.e.,ammoniacal buffer and ACBK—disodium magnesium EDTA solutions.The experimental results of the standard solutions containing 2 and 3 mg/L of total hardness showed that the relative standard deviations(RSDs)were 1.9%and 2.2%,respectively,and the limit of detection(LOD)was only 0.035 mg/L.The detection of four natural water samples showed that the recoveries were between 85.0%and 108.6%,consistent with those obtained by ICP-AES method. 展开更多
关键词 Total hardness Online automatic detection Acid chrome blue K Vector chromaticity measuring device
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部