This paper introduced the components, principle and the hardware and software design of the multiplexing measuring and control instrument to the liquid level that is based on MSP430 SCM. This system is made of pressur...This paper introduced the components, principle and the hardware and software design of the multiplexing measuring and control instrument to the liquid level that is based on MSP430 SCM. This system is made of pressure sensor, signal processing circuit, electromagnetic valve, output driving circuit, Chinese character LCD, keyboard, optic alarm circuit and MSP430MCU, and realized Liquid level automatic monitor, out range alarm and online function.展开更多
We present a method by which to determine the bulk viscosity of water from pulse duration measurements of stimulated Brillouin scattering (SBS). Beginning from a common model of Brillouin scattering, the bulk viscos...We present a method by which to determine the bulk viscosity of water from pulse duration measurements of stimulated Brillouin scattering (SBS). Beginning from a common model of Brillouin scattering, the bulk viscosity is shown to play an important role in Brillouin linewidth determination. Pulse durations of SBS back-reflected optical pulses are measured over the temperature range of 5-40℃. SBS linewidths are de- termined via Fourier transformation of the time-domain results, and the bulk viscosity of water is measured and derived from the obtained values. Our results show that the proposed method for measurement of pulse durations is an effective approach for determining bulk viscosity. The method can be easily extended to determine bulk viscosities of other Newtonian liquids.展开更多
An apparatus for measuring solubilities of gases in liquids at elevated temperatures and pressures has been constructed. Using this apparatus, the slubilities of N_2 and CO_2 in some solvents have been determined in t...An apparatus for measuring solubilities of gases in liquids at elevated temperatures and pressures has been constructed. Using this apparatus, the slubilities of N_2 and CO_2 in some solvents have been determined in the temperature range between 20 and 230℃, and at pressures up to 130 atm. The experimental results obtained generally agree well with literature values. It is shown that this apparatus is reliable; attainment of equilibria needs only about 5 hours; precision of the measure- ments is ±0.2%.展开更多
文摘This paper introduced the components, principle and the hardware and software design of the multiplexing measuring and control instrument to the liquid level that is based on MSP430 SCM. This system is made of pressure sensor, signal processing circuit, electromagnetic valve, output driving circuit, Chinese character LCD, keyboard, optic alarm circuit and MSP430MCU, and realized Liquid level automatic monitor, out range alarm and online function.
基金supported by the National Natural Sci-ence Foundation of China under Grants Nos.41206084 and 61177096
文摘We present a method by which to determine the bulk viscosity of water from pulse duration measurements of stimulated Brillouin scattering (SBS). Beginning from a common model of Brillouin scattering, the bulk viscosity is shown to play an important role in Brillouin linewidth determination. Pulse durations of SBS back-reflected optical pulses are measured over the temperature range of 5-40℃. SBS linewidths are de- termined via Fourier transformation of the time-domain results, and the bulk viscosity of water is measured and derived from the obtained values. Our results show that the proposed method for measurement of pulse durations is an effective approach for determining bulk viscosity. The method can be easily extended to determine bulk viscosities of other Newtonian liquids.
文摘An apparatus for measuring solubilities of gases in liquids at elevated temperatures and pressures has been constructed. Using this apparatus, the slubilities of N_2 and CO_2 in some solvents have been determined in the temperature range between 20 and 230℃, and at pressures up to 130 atm. The experimental results obtained generally agree well with literature values. It is shown that this apparatus is reliable; attainment of equilibria needs only about 5 hours; precision of the measure- ments is ±0.2%.