In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution de...In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution design of multi-group baseline clustering.The effectiveness of the antenna array in this paper is verified by sufficient simulation and experiment.After the system deviation correction work,it is found that in the L/S/C/X frequency bands,the ambiguity resolution probability is high,and the phase difference system error between each channel is basically the same.The angle measurement error is less than 0.5°,and the positioning error is less than 2.5 km.Notably,as the center frequency increases,calibration consistency improves,and the calibration frequency points become applicable over a wider frequency range.At a center frequency of 11.5 GHz,the calibration frequency point bandwidth extends to 1200 MHz.This combined antenna array deployment holds significant promise for a wide range of applications in contemporary wireless communication systems.展开更多
Accurate measurement of the transverse position of a beam is crucial in particle accelerators because it plays a key role in determining the beam parameters.Existing methods for beam-position measurement rely on the d...Accurate measurement of the transverse position of a beam is crucial in particle accelerators because it plays a key role in determining the beam parameters.Existing methods for beam-position measurement rely on the detection of image currents induced on electrodes or narrow-band wake field induced by a beam passing through a cavity-type structure.However,these methods have limitations.The indirect measurement of multiple parameters is computationally complex,requiring external calibration to determine the system parameters in advance.Furthermore,the utilization of the beam signal information is incomplete.Hence,this study proposes a novel method for measuring the absolute electron beam transverse position.By utilizing the geometric relationship between the center position of the measured electron beam and multiple detection electrodes and by analyzing the differences in the arrival times of the beam signals detected by these electrodes,the absolute transverse position of the electron beam crossing the electrode plane can be calculated.This method features absolute position measurement,a position sensitivity coefficient independent of vacuum chamber apertures,and no requirement for a symmetrical detector electrode layout.The feasibility of this method is validated through numerical simulations and beam experiments.展开更多
The incidence of Crohn’s disease(CD)has increased in recent years,with most patients requiring intestinal resection.Complications after intestinal resection for CD can lead to poor prognosis and recurrence,among whic...The incidence of Crohn’s disease(CD)has increased in recent years,with most patients requiring intestinal resection.Complications after intestinal resection for CD can lead to poor prognosis and recurrence,among which infectious complic-ations are the most common.This study aimed to investigate the common risk factors,including medications,preoperative nutritional status,surgery-related factors,microorganisms,lesion location and type,and so forth,causing infectious complications after intestinal resection for CD,and to propose corresponding preventive measures.The findings provided guidance for identifying suscept-ibility factors and the early intervention and prevention of infectious complic-ations after intestinal resection for CD in clinical practice.展开更多
A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity er...A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity errors of PSD and a multilayer feedforward neural network based on error back-propagation algorithm was used to compensate errors. With the aid of computer-based data acquisition system, an automatic dynamic measuring process was realized. A series of experiments, including comparison tests with laser interferometer, were done to evaluate the performance of the measuring system. The experimental results show that the spatial straightness errors of guide rails can be measured with high accuracy. The maximum differences between the device and laser interferometer are 0.027 mm in Y direction, and 0.053 mm in X direction in the measuring distance of 6 m.展开更多
The linear motor applied in electromagnetic emission system uses a closed loop position control strategy,which needs a set of position measurement system with high reliability,high resolution and integration to achiev...The linear motor applied in electromagnetic emission system uses a closed loop position control strategy,which needs a set of position measurement system with high reliability,high resolution and integration to achieve real-time acquisition and analysis of position signals.The existing position controller is based on the simple logic chip design without memory function,and does not have the storage analysis and preprocessing function to position signals.Therefore,the system has insufficient scalability,low integration and reliability.Aiming at the improvement of the existing position measurement system,an intelligent position measurement system integrating the functions of position signals acquisition,processing and uploading,data storage and analysis is proposed in this paper,and its working principle and system composition are discussed in detail.The position,speed and acceleration obtained on the electromagnetic emission platform are in good agreement with the expected value of the system.As results,the feasibility and accuracy of the improved integrated intelligent position measurement system are verified,and the control performance of the system is also satisfied well,which can be good guidance and reference for subsequent engineering practice.展开更多
A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-ge...A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-generation heavy-ion-beam facility HIAF in China.Characterized by low energy loss and good performances of timing and position measurements,it would be located at focal planes in fragment separator HFRS for position monitoring,beam turning,Bq measurement,and trajectory reconstruction.Moreover,it will benefit the building-up of a magnetic-rigidity–energy-loss–time-offlight(BqDETOF)method at HFRS for high-precision in-flight particle identification of radioactive isotope beams on an event-by-event basis.Most importantly,the detector can be utilized for in-ring TOF and position measurements,beam-line TOF measurements at two achromatic foci,and position measurements at a dispersive focus of HFRS,thus making it possible to use two complementary mass measurement methods[isochronous mass spectrometry at the storage ring SRing and magnetic-rigidity–time-of-flight(BqTOF)at the beam-line HFRS]in one single experimental run.展开更多
This fully digital beam position measurement instrument is designed for beam position monitoring and machine research in Shanghai Synchrotron Radiation Facility. The signals received from four position-sensitive detec...This fully digital beam position measurement instrument is designed for beam position monitoring and machine research in Shanghai Synchrotron Radiation Facility. The signals received from four position-sensitive detectors are narrow pulses with a repetition rate up to 499.654 MHz and a pulse width of around 100 ps, and their dynamic range could vary over more than 40 dB in machine research. By the employment of the under-sampling technique based on high-speed high-resolution A/D conversion, all the processing procedure is performed fully by the digital signal processing algorithms integrated in one single Field Programmable Gate Array. This system functions well in the laboratory and commissioning tests, demonstrating a position resolution (at the turn by turn rate of 694 kHz) better than 7 μm over the input amplitude range of -40 dBm to 10 dBm which is well beyond the requirement.展开更多
This article presents a prototype of beam position and phase measurement(BPPM)electronics designed for the LINAC in China Accelerator Driven Sub-critical system(ADS).The signals received from the Beam Position Monitor...This article presents a prototype of beam position and phase measurement(BPPM)electronics designed for the LINAC in China Accelerator Driven Sub-critical system(ADS).The signals received from the Beam Position Monitor(BPM)detectors are narrow pulses with a repetition frequency of 162.5 MHz and a dynamic range more than40 dB.Based on the high-speed high-resolution Analog-to-Digital conversion technique,the input RF signals are directly converted to In-phase and Quadrature-phase(IQ)streams through under-sampling,which simplifies both the analog and digital processing circuits.All signal processing is integrated in one single FPGA,in which real-time beam position,phase and current can be obtained.A series of simulations and tests have been conducted to evaluate the performance.Initial test results indicate that this prototype achieves a phase resolution better than 0.1 degree and a position resolution better than 20μm over a 40 dB dynamic range with the bandwidth of 780 kHz,which is well beyond the application requirements.展开更多
By employing function one-direction S-rough sets and rough law generation method based on function S-rough sets, ^-f-decomposition law and ^-F-decomposition rough law are proposed, and the measurement of rough law var...By employing function one-direction S-rough sets and rough law generation method based on function S-rough sets, ^-f-decomposition law and ^-F-decomposition rough law are proposed, and the measurement of rough law variation in the process of rough law ^-F-decomposition is researched. The concepts of law energy and attdbute ^-f-interference degree are presented, which make the variation of rough law become measurable. ^-f-decomposition law energy characteristic theorem, ^-f- decomposition law energy inequality theorem, ^-F-decomposition rough law energy characteristic theorem, and ^-f-decomposition law energy mean value theorem are presented.展开更多
In this paper, we propose a new method for position-sensitive measurement of beta surface contamination. With a position-sensitive detector of enlarged sensitive detection area, accurate information of the contaminati...In this paper, we propose a new method for position-sensitive measurement of beta surface contamination. With a position-sensitive detector of enlarged sensitive detection area, accurate information of the contamination distribution can be obtained. The positionsensitive detection is based on a large-area plastic scintillator and the wavelength shifting(WLS) fibers and adopts the ‘‘light center of gravity'' method. Optical transmission of the detector is simulated with a preliminary detector model, and feasibility of the detector design and measurement method is evaluated using an experiment system.The simulation and experiment results at different beta-ray incident points on the scintillator surface show that there is a polynomial relationship between the average amplitude ratio of the output pulses from the two parallel WLS fibers in the same fiber layer and the relative distance from the incident point to the WLS fiber.展开更多
This study aimed to investigate the pollution characteristics, source apportionment, and health risks associated with trace metal(loid)s(TMs) in the major agricultural producing areas in Chongqing, China. We analyzed ...This study aimed to investigate the pollution characteristics, source apportionment, and health risks associated with trace metal(loid)s(TMs) in the major agricultural producing areas in Chongqing, China. We analyzed the source apportionment and assessed the health risk of TMs in agricultural soils by using positive matrix factorization(PMF) model and health risk assessment(HRA) model based on Monte Carlo simulation. Meanwhile, we combined PMF and HRA models to explore the health risks of TMs in agricultural soils by different pollution sources to determine the priority control factors. Results showed that the average contents of cadmium(Cd), arsenic (As), lead(Pb), chromium(Cr), copper(Cu), nickel(Ni), and zinc(Zn) in the soil were found to be 0.26, 5.93, 27.14, 61.32, 23.81, 32.45, and 78.65 mg/kg, respectively. Spatial analysis and source apportionment analysis revealed that urban and industrial sources, agricultural sources, and natural sources accounted for 33.0%, 27.7%, and 39.3% of TM accumulation in the soil, respectively. In the HRA model based on Monte Carlo simulation, noncarcinogenic risks were deemed negligible(hazard index <1), the carcinogenic risks were at acceptable level(10^(-6)<total carcinogenic risk ≤ 10^(-4)), with higher risks observed for children compared to adults. The relationship between TMs, their sources, and health risks indicated that urban and industrial sources were primarily associated with As, contributing to 75.1% of carcinogenic risks and 55.7% of non-carcinogenic risks, making them the primary control factors. Meanwhile, agricultural sources were primarily linked to Cd and Pb, contributing to 13.1% of carcinogenic risks and 21.8% of non-carcinogenic risks, designating them as secondary control factors.展开更多
This paper is concerned with the following fourth-order three-point boundary value problem , where , we discuss the existence of positive solutions to the above problem by applying to the fixed point theory in cones a...This paper is concerned with the following fourth-order three-point boundary value problem , where , we discuss the existence of positive solutions to the above problem by applying to the fixed point theory in cones and iterative technique.展开更多
Pedestrian inertial positioning is an effective means when satellites fail. Heading accuracy determines the performance of pedestrian inertial positioning. To realize an accurate positioning, a heading drift correctio...Pedestrian inertial positioning is an effective means when satellites fail. Heading accuracy determines the performance of pedestrian inertial positioning. To realize an accurate positioning, a heading drift correction method was proposed. An in-situ active rotation is performed before autonomous positioning, and the error compensation coefficient of biaxial geomagnetic measurement is obtained by using the ellipse fitting correction method to achieve effective suppression of external environmental geomagnetic interference. The corrected biaxial geomagnetic measurement information is used to directly calculate the heading information and combine it with the peak stride detection method and linear step estimation model to achieve autonomous positioning of pedestrians. To verify the effectiveness and stability of the algorithm, several sets of experiments on the autonomous positioning of pedestrians are carried out in an outdoor environment. The experimental results show that the average deviation between the starting point and the endpoint of the proposed algorithm’s positioning trajectory accounts for 0.95% of the total travel in the 150 m positioning experiments.展开更多
Objective:To investigate the value of liver stiffness measurement(LSM)combined with S index in predicting the degree of liver fibrosis in hepatitis B patients.Methods:A total of 187 chronic hepatitis B patients who we...Objective:To investigate the value of liver stiffness measurement(LSM)combined with S index in predicting the degree of liver fibrosis in hepatitis B patients.Methods:A total of 187 chronic hepatitis B patients who were admitted to the Department of Infection,the First Affiliated Hospital of Hainan Medical College from January 2019 to December 2021 were selected.General data were collected,blood routine,liver function,liver fibrosis and liver stiffness measurement were tested,and S index,APRI and FIB-4 index were calculated,and liver biopsy was performed.Results:According to the pathological results of liver puncture,The patients were divided into no significant fibrosis group(n=86),significant fibrosis group(n=71)and cirrhosis group(n=30).There were significant differences in age,PLT,GGT,ALB,S index,HA,LN and LSM levels among the three groups(P<0.05).There was a good correlation between S index and the degree of hepatic fibrosis(rs=0.738,P<0.001).The AUC of S index and LSM for the diagnosis of significant fibrosis in hepatitis B were 0.873 and 0.792,respectively.And the AUC of S index and LSM for the diagnosis of liver cirrhosis were 0.966 and 0.879,respectively.The AUC for the combined diagnosis of significant fibrosis and cirrhosis were 0.908 and 0.988,respectively.The AUROC of combined detection in the diagnosis of cirrhosis was higher than that of LSM,APRI and FIB-4(P<0.05).Conclusion:LSM combined with S index has certain application value in the diagnosis of liver fibrosis/cirrhosis in hepatitis B patients.展开更多
We present a scheme for probabilistically teleporting an arbitrary unknown two-qubit state through a quantum channel made up of two nonidentical non-maximally entangled states. In this scheme, the probabilistic telepo...We present a scheme for probabilistically teleporting an arbitrary unknown two-qubit state through a quantum channel made up of two nonidentical non-maximally entangled states. In this scheme, the probabilistic teleportation is realized by using a proper positive operator-valued measure instead of usual projective measurement.展开更多
This paper shows that a proposal for implementing all possible two-operator positive-operator-value measurements of single spin qubit can be obtained via introducing another spin qubit as ancilla. The realization proc...This paper shows that a proposal for implementing all possible two-operator positive-operator-value measurements of single spin qubit can be obtained via introducing another spin qubit as ancilla. The realization process is accomplished from the free evolution of the Heisenberg XX model by considering nearest-neighbour spin interaction. A controlled- NOT gate, which is a significant operator for this scheme is also constructed and the generalisation to multiple-operator is considered finally.展开更多
We present a scheme for conclusive teleportation of an arbitrary and unknown three-particle state by per-forming three Bell-state measurements at the sender's side and a positive operator-valued measurement at the...We present a scheme for conclusive teleportation of an arbitrary and unknown three-particle state by per-forming three Bell-state measurements at the sender's side and a positive operator-valued measurement at the receiver'sside.Moreover,we obtain the successful probability of teleportation and make a brief discussion on the average fidelityfor the conclusive teleportation scheme.展开更多
A lower bound to errors of measuring object position is constructed as a function of parameters of a monocular computer vision system (CVS) as well as of observation conditions and a shape of an observed marker. This ...A lower bound to errors of measuring object position is constructed as a function of parameters of a monocular computer vision system (CVS) as well as of observation conditions and a shape of an observed marker. This bound justifies the specification of the CVS parameters and allows us to formulate constraints for an object trajectory based on required measurement accuracy. For making the measurement, the boundaries of marker image are used.展开更多
文摘In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution design of multi-group baseline clustering.The effectiveness of the antenna array in this paper is verified by sufficient simulation and experiment.After the system deviation correction work,it is found that in the L/S/C/X frequency bands,the ambiguity resolution probability is high,and the phase difference system error between each channel is basically the same.The angle measurement error is less than 0.5°,and the positioning error is less than 2.5 km.Notably,as the center frequency increases,calibration consistency improves,and the calibration frequency points become applicable over a wider frequency range.At a center frequency of 11.5 GHz,the calibration frequency point bandwidth extends to 1200 MHz.This combined antenna array deployment holds significant promise for a wide range of applications in contemporary wireless communication systems.
基金supported by the National Key R&D Program of China(No.2022YFA1602201)。
文摘Accurate measurement of the transverse position of a beam is crucial in particle accelerators because it plays a key role in determining the beam parameters.Existing methods for beam-position measurement rely on the detection of image currents induced on electrodes or narrow-band wake field induced by a beam passing through a cavity-type structure.However,these methods have limitations.The indirect measurement of multiple parameters is computationally complex,requiring external calibration to determine the system parameters in advance.Furthermore,the utilization of the beam signal information is incomplete.Hence,this study proposes a novel method for measuring the absolute electron beam transverse position.By utilizing the geometric relationship between the center position of the measured electron beam and multiple detection electrodes and by analyzing the differences in the arrival times of the beam signals detected by these electrodes,the absolute transverse position of the electron beam crossing the electrode plane can be calculated.This method features absolute position measurement,a position sensitivity coefficient independent of vacuum chamber apertures,and no requirement for a symmetrical detector electrode layout.The feasibility of this method is validated through numerical simulations and beam experiments.
基金Supported by Scientific Research Foundation of Shanghai Municipal Health Commission of Changning District,No.20234Y038.
文摘The incidence of Crohn’s disease(CD)has increased in recent years,with most patients requiring intestinal resection.Complications after intestinal resection for CD can lead to poor prognosis and recurrence,among which infectious complic-ations are the most common.This study aimed to investigate the common risk factors,including medications,preoperative nutritional status,surgery-related factors,microorganisms,lesion location and type,and so forth,causing infectious complications after intestinal resection for CD,and to propose corresponding preventive measures.The findings provided guidance for identifying suscept-ibility factors and the early intervention and prevention of infectious complic-ations after intestinal resection for CD in clinical practice.
文摘A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity errors of PSD and a multilayer feedforward neural network based on error back-propagation algorithm was used to compensate errors. With the aid of computer-based data acquisition system, an automatic dynamic measuring process was realized. A series of experiments, including comparison tests with laser interferometer, were done to evaluate the performance of the measuring system. The experimental results show that the spatial straightness errors of guide rails can be measured with high accuracy. The maximum differences between the device and laser interferometer are 0.027 mm in Y direction, and 0.053 mm in X direction in the measuring distance of 6 m.
基金This work was supported in part by the National Natural Science Foundation of China(NSFC)under Grant 51507182 and 51477178.
文摘The linear motor applied in electromagnetic emission system uses a closed loop position control strategy,which needs a set of position measurement system with high reliability,high resolution and integration to achieve real-time acquisition and analysis of position signals.The existing position controller is based on the simple logic chip design without memory function,and does not have the storage analysis and preprocessing function to position signals.Therefore,the system has insufficient scalability,low integration and reliability.Aiming at the improvement of the existing position measurement system,an intelligent position measurement system integrating the functions of position signals acquisition,processing and uploading,data storage and analysis is proposed in this paper,and its working principle and system composition are discussed in detail.The position,speed and acceleration obtained on the electromagnetic emission platform are in good agreement with the expected value of the system.As results,the feasibility and accuracy of the improved integrated intelligent position measurement system are verified,and the control performance of the system is also satisfied well,which can be good guidance and reference for subsequent engineering practice.
基金supported by the National Natural Science Foundation of China(Nos.11605248,11605249,11605267,and 11805032.)
文摘A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-generation heavy-ion-beam facility HIAF in China.Characterized by low energy loss and good performances of timing and position measurements,it would be located at focal planes in fragment separator HFRS for position monitoring,beam turning,Bq measurement,and trajectory reconstruction.Moreover,it will benefit the building-up of a magnetic-rigidity–energy-loss–time-offlight(BqDETOF)method at HFRS for high-precision in-flight particle identification of radioactive isotope beams on an event-by-event basis.Most importantly,the detector can be utilized for in-ring TOF and position measurements,beam-line TOF measurements at two achromatic foci,and position measurements at a dispersive focus of HFRS,thus making it possible to use two complementary mass measurement methods[isochronous mass spectrometry at the storage ring SRing and magnetic-rigidity–time-of-flight(BqTOF)at the beam-line HFRS]in one single experimental run.
基金Supported by Knowledge Innovation Program of The Chinese Academy of Sciences (KJCX2-YW-N27)the National Natural Science Foundation of China (10875119)100 Talents Program of The Chinese Academy of Sciences
文摘This fully digital beam position measurement instrument is designed for beam position monitoring and machine research in Shanghai Synchrotron Radiation Facility. The signals received from four position-sensitive detectors are narrow pulses with a repetition rate up to 499.654 MHz and a pulse width of around 100 ps, and their dynamic range could vary over more than 40 dB in machine research. By the employment of the under-sampling technique based on high-speed high-resolution A/D conversion, all the processing procedure is performed fully by the digital signal processing algorithms integrated in one single Field Programmable Gate Array. This system functions well in the laboratory and commissioning tests, demonstrating a position resolution (at the turn by turn rate of 694 kHz) better than 7 μm over the input amplitude range of -40 dBm to 10 dBm which is well beyond the requirement.
基金Supported by the Knowledge Innovation Program of The Chinese Academy of Sciences(KJCX2-YW-N27)the National Natural Science Foundation of China(No.11205153,11185176,and 10875119)the Fundamental Research Funds for the Central Universities(WK2030040029)
文摘This article presents a prototype of beam position and phase measurement(BPPM)electronics designed for the LINAC in China Accelerator Driven Sub-critical system(ADS).The signals received from the Beam Position Monitor(BPM)detectors are narrow pulses with a repetition frequency of 162.5 MHz and a dynamic range more than40 dB.Based on the high-speed high-resolution Analog-to-Digital conversion technique,the input RF signals are directly converted to In-phase and Quadrature-phase(IQ)streams through under-sampling,which simplifies both the analog and digital processing circuits.All signal processing is integrated in one single FPGA,in which real-time beam position,phase and current can be obtained.A series of simulations and tests have been conducted to evaluate the performance.Initial test results indicate that this prototype achieves a phase resolution better than 0.1 degree and a position resolution better than 20μm over a 40 dB dynamic range with the bandwidth of 780 kHz,which is well beyond the application requirements.
基金supported by the Natural Science Foundation of Shandong Province (Y2007H02)
文摘By employing function one-direction S-rough sets and rough law generation method based on function S-rough sets, ^-f-decomposition law and ^-F-decomposition rough law are proposed, and the measurement of rough law variation in the process of rough law ^-F-decomposition is researched. The concepts of law energy and attdbute ^-f-interference degree are presented, which make the variation of rough law become measurable. ^-f-decomposition law energy characteristic theorem, ^-f- decomposition law energy inequality theorem, ^-F-decomposition rough law energy characteristic theorem, and ^-f-decomposition law energy mean value theorem are presented.
基金supported by the Technology and Industry for National Defense(No.HK.FA1001-1)
文摘In this paper, we propose a new method for position-sensitive measurement of beta surface contamination. With a position-sensitive detector of enlarged sensitive detection area, accurate information of the contamination distribution can be obtained. The positionsensitive detection is based on a large-area plastic scintillator and the wavelength shifting(WLS) fibers and adopts the ‘‘light center of gravity'' method. Optical transmission of the detector is simulated with a preliminary detector model, and feasibility of the detector design and measurement method is evaluated using an experiment system.The simulation and experiment results at different beta-ray incident points on the scintillator surface show that there is a polynomial relationship between the average amplitude ratio of the output pulses from the two parallel WLS fibers in the same fiber layer and the relative distance from the incident point to the WLS fiber.
基金supported by Project of Chongqing Science and Technology Bureau (cstc2022jxjl0005)。
文摘This study aimed to investigate the pollution characteristics, source apportionment, and health risks associated with trace metal(loid)s(TMs) in the major agricultural producing areas in Chongqing, China. We analyzed the source apportionment and assessed the health risk of TMs in agricultural soils by using positive matrix factorization(PMF) model and health risk assessment(HRA) model based on Monte Carlo simulation. Meanwhile, we combined PMF and HRA models to explore the health risks of TMs in agricultural soils by different pollution sources to determine the priority control factors. Results showed that the average contents of cadmium(Cd), arsenic (As), lead(Pb), chromium(Cr), copper(Cu), nickel(Ni), and zinc(Zn) in the soil were found to be 0.26, 5.93, 27.14, 61.32, 23.81, 32.45, and 78.65 mg/kg, respectively. Spatial analysis and source apportionment analysis revealed that urban and industrial sources, agricultural sources, and natural sources accounted for 33.0%, 27.7%, and 39.3% of TM accumulation in the soil, respectively. In the HRA model based on Monte Carlo simulation, noncarcinogenic risks were deemed negligible(hazard index <1), the carcinogenic risks were at acceptable level(10^(-6)<total carcinogenic risk ≤ 10^(-4)), with higher risks observed for children compared to adults. The relationship between TMs, their sources, and health risks indicated that urban and industrial sources were primarily associated with As, contributing to 75.1% of carcinogenic risks and 55.7% of non-carcinogenic risks, making them the primary control factors. Meanwhile, agricultural sources were primarily linked to Cd and Pb, contributing to 13.1% of carcinogenic risks and 21.8% of non-carcinogenic risks, designating them as secondary control factors.
文摘This paper is concerned with the following fourth-order three-point boundary value problem , where , we discuss the existence of positive solutions to the above problem by applying to the fixed point theory in cones and iterative technique.
文摘Pedestrian inertial positioning is an effective means when satellites fail. Heading accuracy determines the performance of pedestrian inertial positioning. To realize an accurate positioning, a heading drift correction method was proposed. An in-situ active rotation is performed before autonomous positioning, and the error compensation coefficient of biaxial geomagnetic measurement is obtained by using the ellipse fitting correction method to achieve effective suppression of external environmental geomagnetic interference. The corrected biaxial geomagnetic measurement information is used to directly calculate the heading information and combine it with the peak stride detection method and linear step estimation model to achieve autonomous positioning of pedestrians. To verify the effectiveness and stability of the algorithm, several sets of experiments on the autonomous positioning of pedestrians are carried out in an outdoor environment. The experimental results show that the average deviation between the starting point and the endpoint of the proposed algorithm’s positioning trajectory accounts for 0.95% of the total travel in the 150 m positioning experiments.
基金Hainan Natural Science Foundation Project(819MS122)。
文摘Objective:To investigate the value of liver stiffness measurement(LSM)combined with S index in predicting the degree of liver fibrosis in hepatitis B patients.Methods:A total of 187 chronic hepatitis B patients who were admitted to the Department of Infection,the First Affiliated Hospital of Hainan Medical College from January 2019 to December 2021 were selected.General data were collected,blood routine,liver function,liver fibrosis and liver stiffness measurement were tested,and S index,APRI and FIB-4 index were calculated,and liver biopsy was performed.Results:According to the pathological results of liver puncture,The patients were divided into no significant fibrosis group(n=86),significant fibrosis group(n=71)and cirrhosis group(n=30).There were significant differences in age,PLT,GGT,ALB,S index,HA,LN and LSM levels among the three groups(P<0.05).There was a good correlation between S index and the degree of hepatic fibrosis(rs=0.738,P<0.001).The AUC of S index and LSM for the diagnosis of significant fibrosis in hepatitis B were 0.873 and 0.792,respectively.And the AUC of S index and LSM for the diagnosis of liver cirrhosis were 0.966 and 0.879,respectively.The AUC for the combined diagnosis of significant fibrosis and cirrhosis were 0.908 and 0.988,respectively.The AUROC of combined detection in the diagnosis of cirrhosis was higher than that of LSM,APRI and FIB-4(P<0.05).Conclusion:LSM combined with S index has certain application value in the diagnosis of liver fibrosis/cirrhosis in hepatitis B patients.
基金The project supported by National Natural Science Foundation of China under Grant No. 10304022,the Science-Technology Fund of Anhui Province for 0utstanding Youth under Grant No. 06042087, the General Fund of the Educational Committee of Anhui Province under Grant No. 2006KJ260B, the Key Fund of the Ministry of Education of China under Grant No. 206063. We are very grateful to Prof. Zhan-Jun Zhang for his detailed instructions and helps.
文摘We present a scheme for probabilistically teleporting an arbitrary unknown two-qubit state through a quantum channel made up of two nonidentical non-maximally entangled states. In this scheme, the probabilistic teleportation is realized by using a proper positive operator-valued measure instead of usual projective measurement.
基金supported by the National Natural Science Foundation of China (Grant No.60667001)
文摘This paper shows that a proposal for implementing all possible two-operator positive-operator-value measurements of single spin qubit can be obtained via introducing another spin qubit as ancilla. The realization process is accomplished from the free evolution of the Heisenberg XX model by considering nearest-neighbour spin interaction. A controlled- NOT gate, which is a significant operator for this scheme is also constructed and the generalisation to multiple-operator is considered finally.
基金the State Key Basic Research and Development Program of China under Grant No.2006CB921604National Natural Science Foundation of China under Grant Nos.60708003,60578050,and 10434060+1 种基金the Science Foundation of Shanghai Science and Technology Committee under Grant No.07JC14017the Director Fund of State Key Laboratory of Precision Spectroscopy
文摘We present a scheme for conclusive teleportation of an arbitrary and unknown three-particle state by per-forming three Bell-state measurements at the sender's side and a positive operator-valued measurement at the receiver'sside.Moreover,we obtain the successful probability of teleportation and make a brief discussion on the average fidelityfor the conclusive teleportation scheme.
文摘A lower bound to errors of measuring object position is constructed as a function of parameters of a monocular computer vision system (CVS) as well as of observation conditions and a shape of an observed marker. This bound justifies the specification of the CVS parameters and allows us to formulate constraints for an object trajectory based on required measurement accuracy. For making the measurement, the boundaries of marker image are used.