期刊文献+
共找到28篇文章
< 1 2 >
每页显示 20 50 100
A Combined Antenna Array Deployment with High Positioning Accuracy and Low Angular Measurement Error
1
作者 Wangjie Chen Weiqiang Zhu +3 位作者 Zhenhong Fan Li Wu Yi He Yixiao Wang 《Journal of Beijing Institute of Technology》 EI CAS 2024年第2期141-154,共14页
In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution de... In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution design of multi-group baseline clustering.The effectiveness of the antenna array in this paper is verified by sufficient simulation and experiment.After the system deviation correction work,it is found that in the L/S/C/X frequency bands,the ambiguity resolution probability is high,and the phase difference system error between each channel is basically the same.The angle measurement error is less than 0.5°,and the positioning error is less than 2.5 km.Notably,as the center frequency increases,calibration consistency improves,and the calibration frequency points become applicable over a wider frequency range.At a center frequency of 11.5 GHz,the calibration frequency point bandwidth extends to 1200 MHz.This combined antenna array deployment holds significant promise for a wide range of applications in contemporary wireless communication systems. 展开更多
关键词 antenna array deployment ambiguity resolution phase consistency angle measurement error positioning error
下载PDF
Improved contact angle measurement in multiphase lattice Boltzmann
2
作者 钟兴国 刘阳莎 +2 位作者 姚怡辰 何冰 闻炳海 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期537-543,共7页
Contact angle is an essential parameter to characterize substrate wettability.The measurement of contact angle in experiment and simulation is a complex and time-consuming task.In this paper,an improved method of meas... Contact angle is an essential parameter to characterize substrate wettability.The measurement of contact angle in experiment and simulation is a complex and time-consuming task.In this paper,an improved method of measuring contact angle in multiphase lattice Boltzmann simulations is proposed,which can accurately obtain the real-time contact angle at a low temperature and larger density ratio.The three-phase contact point is determined by an extrapolation,and its position is not affected by the local deformation of flow field in the three-phase contact region.A series of simulations confirms that the present method has high accuracy and gird-independence.The contact angle keeps an excellent linear relationship with the chemical potential of the surface,so that it is very convenient to specify the wettability of a surface.The real-time contact angle measurement enables us to obtain the dynamic contact angle hysteresis on chemically heterogeneous surface,while the mechanical analyses can be effectively implemented at the moving contact line. 展开更多
关键词 contact angle measurement contact angle hysteresis mechanical analysis lattice Boltzmann method
下载PDF
An angular blinking jamming method based on electronically controlled corner reflectors
3
作者 GAN Lin WU Zehao +1 位作者 WANG Xuesong LI Jianbing 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第2期330-338,共9页
Passive jamming is believed to have very good potential in countermeasure community.In this paper,a passive angular blinking jamming method based on electronically controlled corner reflectors is proposed.The amplitud... Passive jamming is believed to have very good potential in countermeasure community.In this paper,a passive angular blinking jamming method based on electronically controlled corner reflectors is proposed.The amplitude of the incident wave can be modulated by switching the corner reflector between the penetration state and the reflection state,and the ensemble of multiple corner reflectors with towing rope can result in complex angle decoying effects.Dependency of the decoying effect on corner reflectors’radar cross section and positions are analyzed and simulated.Results show that the angle measured by a monopulse radar can be significantly interfered by this method while the automatic tracking is employed. 展开更多
关键词 monopulse radar angular blinking jamming corner reflector amplitude-comparison angle measurement metasurface
下载PDF
Novel Method for Spatial Angle Measurement Based on Rotating Planar Laser Beams 被引量:19
4
作者 YANG Linghui YANG Xueyou ZHU Jigui DUAN Muqiong LAO Dabao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2010年第6期758-764,共7页
Spatial angle measurement, especially the measurement of horizontal and vertical angle, is a basic method used for industrial large-scale coordinate measurement. As main equipments in use, both theodolites and laser t... Spatial angle measurement, especially the measurement of horizontal and vertical angle, is a basic method used for industrial large-scale coordinate measurement. As main equipments in use, both theodolites and laser trackers can provide very high accuracy for spatial angle measurement. However, their industrial applications are limited by low level of automation and poor parallelism. For the purpose of improving measurement efficiency, a lot of studies have been conducted and several alternative methods have been proposed. Unfortunately, all these means are either low precision or too expensive. In this paper, a novel method of spatial angle measurement based on two rotating planar laser beams is proposed and demonstrated. Photoelectric receivers placed on measured points are used to receive the rotating planner laser signals transmitted by laser transmitters. The scanning time intervals of laser planes were measured, and then measured point's horizontal/vertical angles can be calculated. Laser plane's angle parameters are utilized to establish the abstract geometric model of transmitter. Calculating formulas of receiver's horizontal/vertical angles have been derived. Measurement equations' solvability conditions and judgment method of imaginary solutions are also presented after analyzing. Proposed method for spatial angle measurement is experimentally verified through a platform consisting of one laser transmitter and one optical receiver. The transmitters used in new method are only responsible for providing rotating light plane signals carrying angle information. Receivers automatically measure scanning time of laser planes and upload data to the workstation to calculate horizontal angle and vertical angle. Simultaneous measurement of multiple receivers can be realized since there is no human intervention in measurement process .Spatial angle measurement result indicates that the repeatable accuracy of new method is better than 10". Proposed method can improve measurement's automation degree and speed while ensuring measurement accuracy. 展开更多
关键词 large-scale coordinate measurement spatial angle measurement rotating planar laser beams measurement automation
下载PDF
Non-contact angle measurement based on parallel multiplex laser feedback interferometry 被引量:4
5
作者 张松 谈宜东 张书练 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第11期320-324,共5页
We present a novel precise angle measurement scheme based on parallel multiplex laser feedback interferometry (PLFI), which outputs two parallel laser beams and thus their displacement difference reflects the angle ... We present a novel precise angle measurement scheme based on parallel multiplex laser feedback interferometry (PLFI), which outputs two parallel laser beams and thus their displacement difference reflects the angle variation of the target. Due to its ultrahigh sensitivity to the feedback light, PLFI realizes the direct non-contact measurement of non- cooperative targets. Experimental results show that PLFI has an accuracy of 8" within a range of 1400". The yaw of a guide is also measured and the experimental results agree with those of the dual-frequency laser interferometer Agilent 5529A. 展开更多
关键词 laser feedback angle measurement non-cooperative targets
下载PDF
Design of a titl angle measurement system based on ADXL345 sensor 被引量:7
6
作者 SU Yan-ping GONG Mao-fa AN Bin ZHANG Jian-yu ZHAO Xu-jie 《Journal of Measurement Science and Instrumentation》 CAS 2014年第2期19-22,共4页
The titl angle measurement system based on the ADXL345 of three-axis acceleration sensor is introduced, and the composition and working principle of the system are described. The MSP430F149 microcontroller of ultra-lo... The titl angle measurement system based on the ADXL345 of three-axis acceleration sensor is introduced, and the composition and working principle of the system are described. The MSP430F149 microcontroller of ultra-low power and high performance is adopted. Firstly, the voltage value which is proportional to the acceleration value is output by ADXL345 when the system is powered. Secondly, the voltage value is converted into the corresponding digital signal by AD converter of the sensor. Thirdly, the digital signal is transformed into the titl angle according to the arithmetic processing of the MSP430F149. Finally, the corresponding angle is displayed on the liquid crystal display (LCD) screen. Experimental results show that the design has high sensitivity and response speed compared with the conventional methods. It is suitable for practical engineering application because of simple structure, low cost and low power consumption. 展开更多
关键词 ADXL345 MSP430F149 tilt angle measurement liquid crystal display (LCD)
下载PDF
External-cavity birefringence feedback effects of microchip Nd:YAG laser and its application in angle measurement 被引量:2
7
作者 任成 谈宜东 张书练 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第8期3438-3443,共6页
External-cavity birefringence feedback effects of the microchip Nd:YAG laser are presented. When a birefringence element is placed in the external feedback cavity of the laser, two orthogonally polarized laser beams ... External-cavity birefringence feedback effects of the microchip Nd:YAG laser are presented. When a birefringence element is placed in the external feedback cavity of the laser, two orthogonally polarized laser beams with a phase difference are output. The phase difference is twice as large as the phase retardation in the external cavity along the two orthogonal directions. The variable extra-cavity birefringence, caused by rotation of the external-cavity birefringenee element, results in tunable phase difference between the two orthogonally polarized beams. This means that the roll angle information has been translated to phase difference of two output laser beams. A theoretical analysis based on the Fabry-Perot cavity equivalent model and refractive index ellipsoid is presented, which is in good agreement with the experimental results. This phenomenon has potential applications for roll angle measurement. 展开更多
关键词 microchip laser external-cavity birefringence feedback orthogonally polarized lasers angle measurement
下载PDF
STUDY ON MONOPULSE ANGLE MEASUREMENT METHOD BASED ON VIRTUAL POLARIZATION MATCHING
8
作者 Huang Yangang Xu Zhenhai Xiong Ziyuan 《Journal of Electronics(China)》 2013年第5期447-453,共7页
A monopulse angle measurement method for polarization array radar is studied in this paper.The receiving signal model is established and then a monopulse angle measurement method based on virtual polarization matching... A monopulse angle measurement method for polarization array radar is studied in this paper.The receiving signal model is established and then a monopulse angle measurement method based on virtual polarization matching is proposed.To analyze the estimation performance,the Cramer-Rao Lower Bound(CRLB)of angle estimation is derived.Both theoretical analysis and simulation show that:firstly,the proposed method is superior to the traditional angle measurement methods based on the single polarization.Secondly,the performance of the new method is unrelated to the echo polarization.Thirdly,angle estimation of this method is asymptotically optimal.The results show that this method has great potential to be used in polarization array radar. 展开更多
关键词 Polarization array radar Monopulse angle measurement Polarization estimation Virtual polarization matching
下载PDF
Measurement of Mathematical Constant π and Physical Quantity Pi
9
作者 Milan Perkovac 《Journal of Applied Mathematics and Physics》 2016年第10期1899-1905,共7页
Instead of calculating the number π in this article special attention is paid to the method of measuring it. It has been found that there is a direct and indirect measurement of that number. To perform such a measure... Instead of calculating the number π in this article special attention is paid to the method of measuring it. It has been found that there is a direct and indirect measurement of that number. To perform such a measurement, a selection was made of some mathematical and physical quantities which within themselves contain a number π. One such quantity is a straight angle Pi, which may be expressed as Pi = π rad. By measuring the angle, using the direct method, we determine the number π as π = arccos(-1). To implement an indirect measurement of the number π, a system consisting of a container with liquid and equating it with the measuring pot has been conceived. The accuracy of measurement by this method depends on the precision performance of these elements of the system. 展开更多
关键词 PI Greek Letter π Angle measurement Measuring Pot Radian
下载PDF
Biosorption of Cu^(2+) and Zn^(2+) by raw and autoclaved Rocella phycopsis 被引量:7
10
作者 Emine Yalcln Kltigin avusoglu Kadir Klnalloglu 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第3期367-373,共7页
The behavior of Cu2+ and Zn2+ biosorption onto raw and modified Roccella phycopsis from aqueous solutions was studied. Modification process was applied by autoclavation at 121°C for 30 min. The effcts of pH, in... The behavior of Cu2+ and Zn2+ biosorption onto raw and modified Roccella phycopsis from aqueous solutions was studied. Modification process was applied by autoclavation at 121°C for 30 min. The effcts of pH, initial metal concentration and biosorbent dosage were investigated. The maximum Cu2+ biosorption was achieved at pH 5.0 and the maximum biosorption capacities of 31.5 and 37.8 mg/g were recorded for raw and modified biosorbent, respectively. In the case of Zn2+ biosorption, maximum biosorption capacities were obtained at pH 4.0 as 29.1 and 35.3 mg/g for raw and modified biosorbent, respectively. Biosorption of Zn2+ and Cu2+ on all form of R. phycopsis increased much quickly with increasing initial metal concentrations from 10 to 100 mg/L. After modification process, probable changes in the surface polarity of raw and modified R. phycopsis were investigated by contact angle measurements. As expected, R. phycopsis has a polar surface and shows a highest contact angle with water, while after autoclavation water contact angle of R. phycopsis was significantly decreased from 47.5° to 34.4°. 展开更多
关键词 BIOSORPTION Roccella phycopsis polarity contact angle measurement
下载PDF
Orthogonality of inductosyn angle-measuring system error and error-separating technology 被引量:1
11
作者 任顺清 曾庆双 王常虹 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2003年第4期376-379,共4页
Round inductosyn is widely used in inertial navigation test equipment, and its accuracy has significant effect on the general accuracy of the equipment. Four main errors of round inductosyn,i.e. the first-order long-p... Round inductosyn is widely used in inertial navigation test equipment, and its accuracy has significant effect on the general accuracy of the equipment. Four main errors of round inductosyn,i.e. the first-order long-period (360°) harmonic error, the second-order long-period harmonic error, the first-order short-period harmonic error and the second-order short-period harmonic error, are described, and the orthogonality of these four kinds of errors is studied. An error separating technology is proposed to separate these four kinds of errors, and in the process of separating the short-period harmonic errors, the arrangement in the order of decimal part of the angle pitch number can be omitted. The effectiveness of the technology proposed is proved through measuring and adjusting the angular errors. 展开更多
关键词 INDUCTOSYN angle measurement error separation ORTHOGONALITY
下载PDF
Feasible Resolution of Angular Displacement Measurement by an Optical Angle Sensor Based on Laser Autocollimation 被引量:1
12
作者 Hyunsung Lim Yuki Shimizu 《Nanomanufacturing and Metrology》 EI 2023年第4期46-59,共14页
The feasible resolution of angular displacement measurement by an optical angle sensor based on laser autocollimation is investigated.Improving the sensor sensitivity while maintaining the noise level of the sensor si... The feasible resolution of angular displacement measurement by an optical angle sensor based on laser autocollimation is investigated.Improving the sensor sensitivity while maintaining the noise level of the sensor signal as low as possible is necessary to achieve high-resolution angular displacement measurement.In this paper,the contribution of each component,such as a photodiode,a trans-impedance amplifer,and an analog-to-digital converter in the optical angle sensor,to the noise level of the sensor signal is frst estimated on the basis of theoretical equations.The feasible sensitivity of the optical angle sensor is also estimated in numerical calculations.The sensitivity of a photodiode element at the edge of its photosensitive area is evaluated in experiments to realize the estimation of the angle sensor sensitivity.Experimental results are applied to the numerical calculations.The infuences of the measurement laser beam diameter,the spot diameter of the focused laser beam on the photosensitive area,and the focal length of the collimator objective of the optical angle sensor are also consid-ered in the numerical calculations.Finally,a prototype optical setup is developed.Experiments are performed to demonstrate that a compact optical angle sensor based on laser autocollimation with a collimator objective having a focal length shorter than 100 mm can achieve a resolution beyond 0.001 arc-second with a bandwidth of 1 kHz.This resolution is better than those achieved by commercial autocollimators employing an image sensor or a position-sensitive detector.The industrial contribution of this paper lies in the detailed breakdown of noise components in the readout signal of an angle sensor in a practical condition and the systematic estimation of its feasible resolution as well as its sensitivity. 展开更多
关键词 Angle measurement RESOLUTION Laser autocollimation PHOTODIODE Signal noise
原文传递
Angle Measurement Based on Second Harmonic Generation Using Artificial Neural Network 被引量:1
13
作者 Kuangyi Li Zhiyang Zhang +3 位作者 Jiahui Lin Ryo Sato Hiraku Matsukuma Wei Gao 《Nanomanufacturing and Metrology》 EI 2023年第4期1-15,共15页
This article proposed an angle measurement method based on second harmonic generation(SHG)using an artifcial neural network(ANN).The method comprises three sequential parts:SHG spectrum collection,data preprocessing,a... This article proposed an angle measurement method based on second harmonic generation(SHG)using an artifcial neural network(ANN).The method comprises three sequential parts:SHG spectrum collection,data preprocessing,and neural network training.First,the referenced angles and SHG spectrums are collected by the autocollimator and SHG-based angle sensor,respectively,for training.The mapping is learned by the trained ANN after completing the training process,which solves the inverse problem of obtaining the angle from the SHG spectrum.Then,the feasibility of the proposed method is verifed in multiple-peak Maker fringe and single-peak phase-matching areas,with an overall angle measurement range exceeding 20,000 arcseconds.The predicted angles by ANN are compared with the autocollimator to evaluate the measure-ment performance in all the angular ranges.Particularly,a sub-arcsecond level of accuracy and resolution is achieved in the phase-matching area. 展开更多
关键词 Angle measurement Second harmonic generation Artifcial neural network Femtosecond laser
原文传递
Polarization-space joint mainlobe jamming countermeasure technique based on divided dimensions
14
作者 SHA Minghui MAO Erke ZHANG Kang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2022年第3期594-599,共6页
In order to solve the problem that the traditional space jamming countermeasure cannot deal with the mainlobe self-protecting jammings,a polarization-space joint mainlobe jamming countermeasure technique based on divi... In order to solve the problem that the traditional space jamming countermeasure cannot deal with the mainlobe self-protecting jammings,a polarization-space joint mainlobe jamming countermeasure technique based on divided dimensions is proposed.Specifically,the digital beam of each row and column is firstly formed by using dual polarization digital receiving in multi-channel.Then,the polarization-space joint cancellation in both azimuth and elevation dimensions is carried out based on the polarization-space joint difference between the target echo and the jamming,as well as the divided dimension feature of the row and column beams.Finally,the sum and difference beams of the full array in the elevation or azimuth dimension are formed by the beams after jamming cancelling,and the monopulse angle measurement is further employed to obtain target angles.The effectiveness of the proposed technique is verified by simulations,indicating that the self-protecting jamming and multiple mainlobe following jammings can be both cancelled simultaneously with the angle measurement unchanged. 展开更多
关键词 mainlobe jamming countermeasure self-protecting jamming following jamming polarization-space joint cancelling dimension-divided angle measurement
下载PDF
Three-dimensional Information Decoupling System Based on PSD and Deviation Correction
15
作者 YAN Chao-chao LU Jin YANG Hai-ma 《International English Education Research》 2015年第3期101-107,共7页
Three-dimensional Information Decoupling System Based on PSD were designed based on LabVIEW, in order to achieve precision, timeliness, reliability require-ments of the PSD used in the ATP system of Satellite Earth qu... Three-dimensional Information Decoupling System Based on PSD were designed based on LabVIEW, in order to achieve precision, timeliness, reliability require-ments of the PSD used in the ATP system of Satellite Earth quantum communication. Firstly, the laser light source was driven by a stepper motor to scan on the PSD photosensitive surface, and the voltage value was collected and calculated to get the spot position. Analyzing the cause of nonlinear, a mathematical model was built between the actual value and the measured value by using binary quadratic polynomial method, PSD nonlinear correction function would be got. Then, the object micro displacement and angle offset were measured by combining optical triangulation method, and the error of the measurement results was corrected. Experimental results showed that, after the correction, the measuring deviation could be significantly reduced, the PSD performance calibration requirements was achieved, the efficiency of the system was developed greatly by using LabVIEW. 展开更多
关键词 Position sensitive detector (PSD) Three-dimensional Information Decoupling System Binary quadratic polynomial method Microdisplacement measurement Angle measurement
下载PDF
Entanglement-free determination of pretilt angles of twisted nematic liquid-crystal cells by phase measurement
16
作者 姜哲文 林品君 楊界雄 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第8期58-61,共4页
Because of low cost, fast response time, and high light transmittance, thin-film-transistor (TFT) driven twisted nematic (TN) liquid-crystal displays (LCDs) have been widely used in calculators, computer screens... Because of low cost, fast response time, and high light transmittance, thin-film-transistor (TFT) driven twisted nematic (TN) liquid-crystal displays (LCDs) have been widely used in calculators, computer screens, and cell phones. The pretilt angle of the TN medium within the TFT-TN panel affects not only its response times and view- ing angles but also the light-leakage positions of fringed- field-induced disclination lines within pixels of theTFT-TN panel. 展开更多
关键词 TN cell LC Entanglement-free determination of pretilt angles of twisted nematic liquid-crystal cells by phase measurement
原文传递
An improved method of angle measurement with a position sensitive detector 被引量:4
17
作者 郑德锋 王向朝 唐锋 《Chinese Optics Letters》 SCIE EI CAS CSCD 2007年第7期403-406,共4页
An improved method of angle measurement is proposed based on a parallel plate interferometer. A position detection system is incorporated into a parallel plate interferometer in order to realize large deflection angle... An improved method of angle measurement is proposed based on a parallel plate interferometer. A position detection system is incorporated into a parallel plate interferometer in order to realize large deflection angle measurement. A reflecting mirror is introduced for increasing the measurement resolution. In experiments, a deflection angle of a measured target was measured within ~3° with high accuracy. And as a phase modulating interferometer, it was used to measure a small angular displacement with a repeatability of 5.5 × 10^-8 rad. 展开更多
关键词 An improved method of angle measurement with a position sensitive detector LENGTH
原文传递
Roll angle measurement with a large range based on the photoelectronic autocollimator 被引量:1
18
作者 李文杰 穆全全 +4 位作者 王少鑫 王海萍 杨程亮 曹召良 宣丽 《Optoelectronics Letters》 EI 2016年第1期74-76,共3页
In this paper,we propose a roll angle measurement method with a large range based on the photoelectronic autocollimator.According to the corresponding relationship between the rotation position of the measured shaft a... In this paper,we propose a roll angle measurement method with a large range based on the photoelectronic autocollimator.According to the corresponding relationship between the rotation position of the measured shaft and the spot position on the circular trajectory,the roll angle is calculated quickly and conveniently using a simple algorithm.Only a mirror,a coupler and a fine shaft are contained in the measurement system besides the photoelectronic autocollimator.Aiming at the terrible measurement error induced by the axis wobbly error,two measurement schemes are proposed,which are linking the fine precision shaft to the measured shaft for reducing the axis wobbly error and using the segment measurement to enlarge the radius of the circular trajectory.The experimental results show that the measurement error is decreased by ±0.38°.The roll angle error of the mechanism is ±0.14°,and the measurement precision is about ±2′.The proposed method can be widely used in the engineering fields. 展开更多
关键词 Angle measurement measurement errors
原文传递
Simultaneous measurement of vibration amplitude and rotation angle based on a single-channel laser self-mixing interferometer 被引量:2
19
作者 孙悟 刘建国 +3 位作者 桂华侨 鲁岸立 王焕钦 陆亦怀 《Chinese Optics Letters》 SCIE EI CAS CSCD 2016年第2期23-26,共4页
Based on a single-channel laser self-mixing interferometcr, we present a new silnultaneous measurement of the vibration amplitude and tile rotation angle of objects that both affect the power spectrum containing two p... Based on a single-channel laser self-mixing interferometcr, we present a new silnultaneous measurement of the vibration amplitude and tile rotation angle of objects that both affect the power spectrum containing two peaks of the interferometer signals. The fitted results indicate that the curve of the peak frequency versus the vibration amplitude follows a linear distribution, and the curve of the difference of the two-peak power values versus the angle follows a Gaussian distribution. A vibration amplitude with an error less than 3.0% and a rotation angle with an error less than 11.7% are calculated from the fitted results. 展开更多
关键词 Simultaneous measurement of vibration amplitude and rotation angle based on a single-channel laser self-mixing interferometer LSM
原文传递
A comprehensive survey on the methods of angle of attack measurement and estimation in UAVs
20
作者 L.SANKARALINGAM C.RAMPRASADH 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2020年第3期749-770,共22页
Angle of Attack(AOA) is a crucial parameter which directly affects the aerodynamic forces of an aircraft.The measurement of AOA is required to ensure a safe flight within its designed flight envelop.This paper intends... Angle of Attack(AOA) is a crucial parameter which directly affects the aerodynamic forces of an aircraft.The measurement of AOA is required to ensure a safe flight within its designed flight envelop.This paper intends to summarise a comprehensive survey on the measurement techniques and estimation methods for AOA, specifically in Unmanned Aerial Vehicle(UAV) applications.In the case of UAVs, weight constraint plays a major role as far as sensor suites are concerned.This results in selecting a suitable estimation method to extract AOA using the available data from the autopilot.The most feasible and widely employed AOA measurement technique is by using the Multi-Hole Probes(MHPs).The MHP measures the AOA regarding the pressure variations between the ports.Due to the importance of MHP in AOA measurement, the calibration methods for the MHP are also included in this paper.This paper discusses the AOA measurement using virtual AOA sensors, their importance and the operation. 展开更多
关键词 Angle of attack estimation Angle of attack measurement Angle of attack vane Five-hole probe Multi-hole probe Multi-hole probe calibration Nine-hole probe Seven-hole probe Virtual angle of attack sensor
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部