We present the thermal expansion coefficient (TEC) measurement technology of compensating for the effect of variations in the refractive index based on a Nd: YA G laser feedback system, the beam frequency is shifte...We present the thermal expansion coefficient (TEC) measurement technology of compensating for the effect of variations in the refractive index based on a Nd: YA G laser feedback system, the beam frequency is shifted by a pair of aeousto-optic modulators and then the heterodyne phase measurement technique is used. The sample measured is placed in a muffle furnace with two coaxial holes opened on the opposite furnace walls. The measurement beams hit perpendicularly and coaxially on each surface of the sample. The reference beams hit on the reference mirror and the high-refiectivity mirror, respectively. By the heterodyne configuration and computing, the influences of the vibration, distortion of the sample supporter and the effect of variations in the refractive index are measured and largely minimized. For validation, the TECs of aluminum samples are determined in the temperature range of 29-748K, confirming not only the precision within 5 × 10-7 K-1 and the accuracy within 0.4% from 298K to 448K but also the high sensitivity non-contact measurement of the lower reflectivity surface induced by the sample oxidization from 448 K to 748 K.展开更多
We present a simple but effective method for small-angle measurement based on optical feedback interferometry (or laser self-mixing interferometry). The absolute zero angle can be defined at the biggest fringe ampli...We present a simple but effective method for small-angle measurement based on optical feedback interferometry (or laser self-mixing interferometry). The absolute zero angle can be defined at the biggest fringe amplitude point, so this method can also achieve absolute angle measurement. In order to verify the method, we construct an angle measurement system. The Fourier-transform method is used to analysis the interference signal. Rotation angles are experimentally measured with a resolution of 10^-6 rad and a measurement range of approximately from -0.0007 to +0.0007 rad.展开更多
In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied ...In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied to extract reversion point in the self-mixing interference signal, thus the pulse wave profile is successfully reconstructed. Considering the blood pressure values are intrinsically related to characteristic parameters of the pulse wave, 80 samples from the MIMIC-II database are used to train the extreme learning machine blood pressure model. In the experiment, 15 measured samples of pulse wave signal are used as the prediction sets. The results show that the errors of systolic and diastolic blood pressure are both within 5 mm Hg compared with that by the Coriolis method.展开更多
This paper presents a review of recent progress in simultaneous measurement of multiparameters including strain, temperature, vibration, transverse load, based on the combinations of extrinsic fiber-optic Fabry-Perot ...This paper presents a review of recent progress in simultaneous measurement of multiparameters including strain, temperature, vibration, transverse load, based on the combinations of extrinsic fiber-optic Fabry-Perot interferometers and fiber gratings.展开更多
The equi-luminance of color stimulus in normal subjects is characterized by L-cone and M-cone activation in retina. For the protanopes and deuternopes, only the activations of one relevant remaining cone type should b...The equi-luminance of color stimulus in normal subjects is characterized by L-cone and M-cone activation in retina. For the protanopes and deuternopes, only the activations of one relevant remaining cone type should be considered. The equi-luminance turning curve was established for the recorded visual evoked potentials (VEPs) of the luminance changes of the red and green color stimulus, and the position of the equi-luminance was used to define the kind and degree of color vision deficiencies. In the test of 47 volunteers we got the VEP traces and the equi-luminance turning curves, which was in accordance with the judgment by the pseudoisochromatic plate used in clinic. The method fulfills the objective and quantitative requirements in color vision deficiencies test.展开更多
When characterizing flows in miniaturized channels, the determination of the dynamic contact angle is important. By measuring the dynamic contact angle, the flow properties of the flowing liquid and the effect of mate...When characterizing flows in miniaturized channels, the determination of the dynamic contact angle is important. By measuring the dynamic contact angle, the flow properties of the flowing liquid and the effect of material properties on the flow can be characterized. A machine vision based system to measure the contact angle of front or rear menisci of a moving liquid plug is described in this article. In this research, transparent flow channels fabricated on thermoplastic polymer and sealed with an adhesive tape are used. The transparency of the channels enables image based monitoring and measurement of flow variables, including the dynamic contact angle. It is shown that the dynamic angle can be measured from a liquid flow in a channel using the image based measurement system. An image processing algorithm has been developed in a MATLAB environment. Images are taken using a CCD camera and the channels are illuminated using a custom made ring light. Two fitting methods, a circle and two parabolas, are experimented and the results are compared in the measurement of the dynamic contact angles.展开更多
Photo Diode Array (PDA) has been successfully applied in HT-7 tokamak experiments. The PDA system is almost free of electromagnetic interference from the machine. The system is compact and inexpensive, and it is conve...Photo Diode Array (PDA) has been successfully applied in HT-7 tokamak experiments. The PDA system is almost free of electromagnetic interference from the machine. The system is compact and inexpensive, and it is convenient to be arranged in experiment. With the PDA system, the particle confinement time (τp) has been systematically investigated. The relations such as τp on the center-line-averaged electron density (ne), τp on plasma current (Ip), and τp, on the toroidal magnetic field (Bt) have been obtained. The particle confinement under the Ion Berstain Wave (IBW) Heating has also been measured and analyzed.展开更多
Real time remaining useful life(RUL) prediction based on condition monitoring is an essential part in condition based maintenance(CBM). In the current methods about the real time RUL prediction of the nonlinear degrad...Real time remaining useful life(RUL) prediction based on condition monitoring is an essential part in condition based maintenance(CBM). In the current methods about the real time RUL prediction of the nonlinear degradation process, the measurement error is not considered and forecasting uncertainty is large. Therefore, an approximate analytical RUL distribution in a closed-form of a nonlinear Wiener based degradation process with measurement errors was proposed. The maximum likelihood estimation approach was used to estimate the unknown fixed parameters in the proposed model. When the newly observed data are available, the random parameter is updated by the Bayesian method to make the estimation adapt to the item's individual characteristic and reduce the uncertainty of the estimation. The simulation results show that considering measurement errors in the degradation process can significantly improve the accuracy of real time RUL prediction.展开更多
Based on split plot design method of field test,the impacts of supplemental irrigation based on soil moisture measurement and nitrogen use on winter wheat yield and nitrogen absorption and distribution were studied.Su...Based on split plot design method of field test,the impacts of supplemental irrigation based on soil moisture measurement and nitrogen use on winter wheat yield and nitrogen absorption and distribution were studied.Supplemental irrigation had three levels: 60%(W_1),70%(W_2) and 80%(W3) of the targeted relative water content at 0-40 cm of soil layer during jointing period of winter wheat.Nitrogen fertilization had three levels: not using nitrogen(N_0),using pure nitrogen of 195 kg/hm^2(N_(195)) and 255 kg/hm^2(N_(255)).Results showed that:(i)different supplemental irrigation and nitrogen fertilization significantly affected plant height and leaf area of winter wheat during key growth period.Under the same supplemental irrigation treatment,both plant height and leaf area of winter wheat showed as N_(255)> N_(195)> N_0(P <0.05).Plant height in N_(195) and N_(255)treatments was significantly higher than that in N_0 treatment,but there was not significant difference between N_(195) and N_(255)(P >0.05).Under the same nitrogen fertilization,plant height in W_2(569.4 m^3/hm^2) and W3(873.45 m^3/hm^2) treatments was significant higher than that in W_1(265.2 m^3/hm^2),but there was not significant difference between W_2 and W3(P >0.05).It illustrated that excessive nitrogen fertilization and supplemental irrigation did not significantly affect plant height and leaf area of winter wheat.(ii) Under the same nitrogen fertilization level,yield increase effect of winter wheat by supplemental irrigation showed a declining trend with nitrogen application amount increased.It illustrated that nitrogen fertilization and supplemental irrigation had certain critical values on the yield of winter wheat.When surpassing the critical value,the yield declined.When nitrogen fertilization amount was 195 kg/hm^2,and supplemental irrigation amount was 70% of field moisture capacity(569.4 m^3/hm^2),the highest yield 8500 kg/hm^2 could be obtained.(iii) During mature period of winter wheat,nitrogen accumulation amount of plant treated by nitrogen was significantly higher than that not treated by nitrogen(P <0.05).But under the treatments of W_2 and W3,nitrogen accumulation amount in N_(255) significantly declined when compared with N_(195)(P <0.05).Especially under W3(873.45 m^3/hm^2) level,nitrogen accumulation amount in N_(255) was even lower than N_0.Under the treatments of N_0 and N_(195),nitrogen accumulation amount of plant significantly increased with supplemental irrigation increased(P < 0.05).But under N_(255) treatment,there was not significant difference(P > 0.05).It illustrated that moderate supplemental irrigation and nitrogen fertilization could improve nitrogen absorption ability of winter wheat,but excessive supplemental irrigation and nitrogen fertilization were not favorable for plant's nitrogen absorption.(iv) Although the increase of supplemental irrigation during jointing period improved nitrogen absorption ability of winter wheat and promoted winter wheat absorbing more nitrogen,it inhibited nitrogen transferring and distributing to seed.Comprehensively considering growth condition of winter wheat and nitrogen risk condition,it is suggested that nitrogen application amount was 195 kg/hm^2,and supplemental irrigation reached 70% of field moisture capacity(569.4 m^3/hm^2),which could be as the suitable water and fertilizer use amounts in the region.展开更多
The experimental investigation of unsteady complex flow fields in wind tunnels requires advanced measurement techniques. The most important of such image based measurement techniques are those for the measurement of p...The experimental investigation of unsteady complex flow fields in wind tunnels requires advanced measurement techniques. The most important of such image based measurement techniques are those for the measurement of planar flow velocity fields, planar pressure distribution, model location and deformation, model temperature and quantitative high speed flow visualization. The applications as carried out by DLR range from low speed flows to transonic flows, from high lift configurations to propellers and rotors, from wake vortex investigations in catapult facilities and water towing tanks to investigations of vortex break down phenomena on delta wings. The capability to use image based measurement techniques in transonic flows requires dedicated technical developments and experienced scientists due to the special environment of a transonic wind tunnel. In this paper an overview of the state-of-the art of the application of image based measurement techniques in transonic flows as performed by DLR's Institute of Aerodynamics and Flow Technology will be given.展开更多
One of the most challenging tasks in the laser-driven Hugoniot experiment is how to increase the reproducibility and precision of the experimental data to meet the stringent requirement in validating equation of state...One of the most challenging tasks in the laser-driven Hugoniot experiment is how to increase the reproducibility and precision of the experimental data to meet the stringent requirement in validating equation of state models. In such cases, the contribution of intrinsic uncertainty becomes important and cannot be ignored. A detailed analysis of the intrinsic uncertainty of the aluminum-iron impedance-match experiment based on the measurement of velocities is presented. The influence of mirror-reflection approximation on the shocked pressure of Fe and intrinsic uncertainties from the equation of state uncertainty of standard material are quantified, Furthermore, the comparison of intrinsic uncertainties of four different experimental approaches is presented. It is shown that, compared with other approaches including the most widely used approach which relies on the measurements of the shock velocities of AI and Fe, the approach which relies on the measurement of the particle velocity of Al and the shock velocity of Fe has the smallest intrinsic uncertainty, which would promote such work to significantly improve the diagnostics precision in such an approach.展开更多
The maximum entangled number state (NOON state) can improve the sensitivity of physical quantity measure- ment to the Heisenberg limit 1/N. In this work, the magnetic field measurement based on the individual solid ...The maximum entangled number state (NOON state) can improve the sensitivity of physical quantity measure- ment to the Heisenberg limit 1/N. In this work, the magnetic field measurement based on the individual solid spin NOON state is investigated. Based on the tunable effective coupling coefficient, we propose a generation scheme of the three-spin NOON state, i.e, the Creenberger-Horne-Zeilinger (CHZ) state, and discussed the mea- surement resolution reduction due to decoherence. It is unnecessary to entangle spins as many as possible when decoherence exists. In practice, defect spins in diamond and alp donors with long coherence time can be applied with current techniques in the nano-scaled high resolution magnetic measurement.展开更多
BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacia...BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacial neuralgia from the experience of puncture operator only to puncture by taking the objective data of measurement as the evidence, which is good for improving the accuracy of puncturing trigeminal ganglion and reducing side effects. OBJECTIVE : To observe the forms of foramen ovales in healthy adults displayed by volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan of skull base, and measure the longitudinal diameter and transverse diameter. DESIGN : A repetitive observation and measurement SETTINGS : Department of Neurosurgery and Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine. PARTICIPANTS: Fifty healthy adults (100 sides), who were examined with three-dimensional spiral CT scan, were randomly selected from the Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine from January 2005 to January 2006, including 26 males and 24 females, aged 25-68 years with an average of 48 years old. They were all informed and agreed with the examination. METHODS : The subjects were examined with the Philips 16-slice spiral CT-Mx 8000 IDT CT apparatus (Philips Company, Holland), the scanning ranged from 2 cm below the canthomeatal line to the level of suprasellar cistem. The width of collimator was 0.75 mm, pitch was 0.663; tube current was 350 mA, voltage was 120 kV, resolution was 512×512 matrix; slice thickness of reconstruction was 1 mm, and interval was 0.5 mm. After the three-dimensional spiral CT thin-slice scan of skull base, the image post-processing techniques including volume rendering and multi-planar reconstruction were applied to observe the forms of foramen ovales, and measure the size, longitudinal diameter and transverse diameter of the foramen ovales. The figures of the foramen ovales were drawn with mouse along the boundary of bone porous margin and soft tissue. According to the indications, the diameters were measured with computer to observe the forms of foramen ovales. MAIN OUTCOME MEASURES : The longitudinal diameter, transverse diameter and form of foramen ovales were observed. RESULTS: All the 50 healthy adults (100 sides) were involved in the analysis of results. (1) It was observed in the volume rendering images that foramen ovales had four forms of oval shape (77 sides), kidney shape (12 sides), round shape (7 sides), ribbon shape (4 sides). (2) The longitudinal diameters of left and right foramen ovales were (7.67±1.32) and (7.98±1.45) mm, and the transverse diameters were (4.04±0.83), (4.09±1.07) mm; There was no obvious difference between left and right longitudinal diameters (t = 1.63, P = 0.11 ), and left and right transverse diameters were close (t = 0.45, P= 0.65). CONCLUSION : The non-invasive techniques of volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan can clearly display the formand size of foramen ovale in healthy adults.展开更多
Aiming at the approximate measurement of magnetic rotation angle in optical current sensor based on light intensity detection mode,this paper proposes a current measurement method based on triangular constant transfor...Aiming at the approximate measurement of magnetic rotation angle in optical current sensor based on light intensity detection mode,this paper proposes a current measurement method based on triangular constant transformation to reconstruct magnetic rotation angle,so as to avoid the large current measurement error caused by the approximate measurement of the magnetic rotation angle.By extracting the direct current(DC)component and the alternating current(AC)component of the light intensity signal detected by the photoelectric detector(PD),the sine signal containing the magnetic rotation angle is directly obtained by dividing the two components,and then the triangular identity transformation method is used to linearly demodulate the magnetic rotation angle and reconstruct the current waveform.The experimental results show that the relative error of current measurement does not exceed 1.40%in the current range of 0.05—0.50 A,which is less than the approximate linear measurement(ALM)method,and the magnetic rotation angle and the current have a good linear relationship.展开更多
A criterion for he tquantum teleportation of an arbitrary N-particle state via a 2N-particle quantum channel is presented by introducing a term of the judgment operator''. Using the criterion, not only the qualitati...A criterion for he tquantum teleportation of an arbitrary N-particle state via a 2N-particle quantum channel is presented by introducing a term of the judgment operator''. Using the criterion, not only the qualitative judgment of the possibility of successful teleportation can be made but also the quantitative calculation of the probability of successful teleportation can be explicitly given. In addition, a new genuine four-qubit entangled state is proposed, which could not belong to the category of previously known states under stochastic local operations and classical communication.展开更多
运用含非期望产出的超效率SBM(slack based measure)模型和GML(global Malmquist-Luenberger)指数,对中国与世界主要国家1991—2016年的分别在考虑和不考虑环境约束下的技术效率和全要素生产率进行测度与比较。研究发现,不考虑环境约束...运用含非期望产出的超效率SBM(slack based measure)模型和GML(global Malmquist-Luenberger)指数,对中国与世界主要国家1991—2016年的分别在考虑和不考虑环境约束下的技术效率和全要素生产率进行测度与比较。研究发现,不考虑环境约束的测度结果忽略了一国发展所造成的污染损失,导致技术效率与生产率被高估;中国的技术效率在考虑环境因素后显著下降,总效率排名从样本中的第16位下降至第40位。时间趋势上,中国的环境效率与技术效率的差距呈现先扩大后缩小,且近年来有逐渐趋同的态势;动态视角上,不考虑环境约束时中国的全要素生产率变化总体呈现增长趋势,但在考虑环境因素后中国的环境全要素生产率转变为下降趋势,这其中,技术进步的下降是影响环境全要素生产率变化的主要因素。展开更多
We propose two schemes for realizing quantum secure direct communication (QSDC)by using a set ofordered two-photon three-dimensional hyperentangled states entangled in two degrees of freedom (DOFs)as quantuminformatio...We propose two schemes for realizing quantum secure direct communication (QSDC)by using a set ofordered two-photon three-dimensional hyperentangled states entangled in two degrees of freedom (DOFs)as quantuminformation channels.In the first scheme,the photons from Bob to Alice are transmitted only once.After insuring thesecurity of the quantum channels,Bob encodes the secret message on his photons.Then Alice performs single-photontwo-DOF Bell bases measurements on her photons.This scheme has better security than former QSDC protocols.In thesecond scheme,Bob transmits photons to Alice twice.After insuring the security of the quantum channels,Bob encodesthe secret message on his photons.Then Alice performs two-photon Bell bases measurements on each DOF.The schemehas more information capacity than former QSDC protocols.展开更多
Various technologies have recently been developed for high-speed railways, in order to boost commercial speeds from 300 km.h: to 400 km.h-1. Among these technologies, this paper introduces the 400 km-h-1 class curren...Various technologies have recently been developed for high-speed railways, in order to boost commercial speeds from 300 km.h: to 400 km.h-1. Among these technologies, this paper introduces the 400 km-h-1 class current collection performance evaluation methods that have been developed and demonstrated by Korea. Specifically, this paper reports details of the video-based monitoring techniques that have been adopted to inspect the stability of overhead contact line (OCL) components at 400 km.h-1 without direct contact with any components of the power supply system. Unlike conventional OCL monitoring systems, which detect contact wire positions using either laser sensors or line cameras, the developed system measures parameters in the active state by video data. According to experimental results that were obtained at a field-test site established at a commercial line, it is claimed that the proposed mea- surement system is capable of effectively measuring OCL parameters.展开更多
The purpose of this study is to develop a standard methodology for measuring the surface free energy (SFE),and its component parts of bamboo fiber materials.The current methods was reviewed to determine the surface te...The purpose of this study is to develop a standard methodology for measuring the surface free energy (SFE),and its component parts of bamboo fiber materials.The current methods was reviewed to determine the surface tension of natural fibers and the disadvantages of techniques used were discussed.Although numerous techniques have been employed to characterize surface tension of natural fibers,it seems that the credibility of results obtained may often be dubious.In this paper,critical surface tension estimates were obtained from computer aided machine vision based measurement.Data were then analyzed by the least squares method to estimate the components of SFE.SFE was estimated by least squares analysis and also by Schultz' method.By using the Fowkes method the polar and disperse fractions of the surface free energy of bamboo fiber materials can be obtained.Strictly speaking,this method is based on a combination of the knowledge of Fowkes theory. SFE is desirable when adhesion is required,and it avoids some of the limitations of existing studies which has been proposed.The calculation steps described in this research are only intended to explain the methods.The results show that the method that only determines SFE as a single parameter may be unable to differentiate adequately between bamboo fiber materials,but it is feasible and very efficient.In order to obtain the maximum performance from the computer aided machine vision based measurement instruments,this measurement should be recommended and kept available for reference.展开更多
基金Supported by the National Natural Science Foundation of China under Grant No F050306
文摘We present the thermal expansion coefficient (TEC) measurement technology of compensating for the effect of variations in the refractive index based on a Nd: YA G laser feedback system, the beam frequency is shifted by a pair of aeousto-optic modulators and then the heterodyne phase measurement technique is used. The sample measured is placed in a muffle furnace with two coaxial holes opened on the opposite furnace walls. The measurement beams hit perpendicularly and coaxially on each surface of the sample. The reference beams hit on the reference mirror and the high-refiectivity mirror, respectively. By the heterodyne configuration and computing, the influences of the vibration, distortion of the sample supporter and the effect of variations in the refractive index are measured and largely minimized. For validation, the TECs of aluminum samples are determined in the temperature range of 29-748K, confirming not only the precision within 5 × 10-7 K-1 and the accuracy within 0.4% from 298K to 448K but also the high sensitivity non-contact measurement of the lower reflectivity surface induced by the sample oxidization from 448 K to 748 K.
基金supported by the National Natural Science Foundation of China under Grant No.60677019.
文摘We present a simple but effective method for small-angle measurement based on optical feedback interferometry (or laser self-mixing interferometry). The absolute zero angle can be defined at the biggest fringe amplitude point, so this method can also achieve absolute angle measurement. In order to verify the method, we construct an angle measurement system. The Fourier-transform method is used to analysis the interference signal. Rotation angles are experimentally measured with a resolution of 10^-6 rad and a measurement range of approximately from -0.0007 to +0.0007 rad.
基金supported by the National Natural Science Foundation of China (No.61675174)the Natural Science Foundation of Fujian Province (No.2020J01705)。
文摘In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied to extract reversion point in the self-mixing interference signal, thus the pulse wave profile is successfully reconstructed. Considering the blood pressure values are intrinsically related to characteristic parameters of the pulse wave, 80 samples from the MIMIC-II database are used to train the extreme learning machine blood pressure model. In the experiment, 15 measured samples of pulse wave signal are used as the prediction sets. The results show that the errors of systolic and diastolic blood pressure are both within 5 mm Hg compared with that by the Coriolis method.
文摘This paper presents a review of recent progress in simultaneous measurement of multiparameters including strain, temperature, vibration, transverse load, based on the combinations of extrinsic fiber-optic Fabry-Perot interferometers and fiber gratings.
文摘The equi-luminance of color stimulus in normal subjects is characterized by L-cone and M-cone activation in retina. For the protanopes and deuternopes, only the activations of one relevant remaining cone type should be considered. The equi-luminance turning curve was established for the recorded visual evoked potentials (VEPs) of the luminance changes of the red and green color stimulus, and the position of the equi-luminance was used to define the kind and degree of color vision deficiencies. In the test of 47 volunteers we got the VEP traces and the equi-luminance turning curves, which was in accordance with the judgment by the pseudoisochromatic plate used in clinic. The method fulfills the objective and quantitative requirements in color vision deficiencies test.
基金This research was done as part of TEKES-funded PanFlow project and as part of a project OPTIMI funded by the Academy of Finland (grant number 117587) in Micro- and Nanosystems Research Group, Tampere University of Technology, Finland.
文摘When characterizing flows in miniaturized channels, the determination of the dynamic contact angle is important. By measuring the dynamic contact angle, the flow properties of the flowing liquid and the effect of material properties on the flow can be characterized. A machine vision based system to measure the contact angle of front or rear menisci of a moving liquid plug is described in this article. In this research, transparent flow channels fabricated on thermoplastic polymer and sealed with an adhesive tape are used. The transparency of the channels enables image based monitoring and measurement of flow variables, including the dynamic contact angle. It is shown that the dynamic angle can be measured from a liquid flow in a channel using the image based measurement system. An image processing algorithm has been developed in a MATLAB environment. Images are taken using a CCD camera and the channels are illuminated using a custom made ring light. Two fitting methods, a circle and two parabolas, are experimented and the results are compared in the measurement of the dynamic contact angles.
文摘Photo Diode Array (PDA) has been successfully applied in HT-7 tokamak experiments. The PDA system is almost free of electromagnetic interference from the machine. The system is compact and inexpensive, and it is convenient to be arranged in experiment. With the PDA system, the particle confinement time (τp) has been systematically investigated. The relations such as τp on the center-line-averaged electron density (ne), τp on plasma current (Ip), and τp, on the toroidal magnetic field (Bt) have been obtained. The particle confinement under the Ion Berstain Wave (IBW) Heating has also been measured and analyzed.
基金Projects(51475462,61374138,61370031)supported by the National Natural Science Foundation of China
文摘Real time remaining useful life(RUL) prediction based on condition monitoring is an essential part in condition based maintenance(CBM). In the current methods about the real time RUL prediction of the nonlinear degradation process, the measurement error is not considered and forecasting uncertainty is large. Therefore, an approximate analytical RUL distribution in a closed-form of a nonlinear Wiener based degradation process with measurement errors was proposed. The maximum likelihood estimation approach was used to estimate the unknown fixed parameters in the proposed model. When the newly observed data are available, the random parameter is updated by the Bayesian method to make the estimation adapt to the item's individual characteristic and reduce the uncertainty of the estimation. The simulation results show that considering measurement errors in the degradation process can significantly improve the accuracy of real time RUL prediction.
基金Supported by National Key Research Plan Project(2016YFD0801001,2016YFD0200103,2017YFD0800500)
文摘Based on split plot design method of field test,the impacts of supplemental irrigation based on soil moisture measurement and nitrogen use on winter wheat yield and nitrogen absorption and distribution were studied.Supplemental irrigation had three levels: 60%(W_1),70%(W_2) and 80%(W3) of the targeted relative water content at 0-40 cm of soil layer during jointing period of winter wheat.Nitrogen fertilization had three levels: not using nitrogen(N_0),using pure nitrogen of 195 kg/hm^2(N_(195)) and 255 kg/hm^2(N_(255)).Results showed that:(i)different supplemental irrigation and nitrogen fertilization significantly affected plant height and leaf area of winter wheat during key growth period.Under the same supplemental irrigation treatment,both plant height and leaf area of winter wheat showed as N_(255)> N_(195)> N_0(P <0.05).Plant height in N_(195) and N_(255)treatments was significantly higher than that in N_0 treatment,but there was not significant difference between N_(195) and N_(255)(P >0.05).Under the same nitrogen fertilization,plant height in W_2(569.4 m^3/hm^2) and W3(873.45 m^3/hm^2) treatments was significant higher than that in W_1(265.2 m^3/hm^2),but there was not significant difference between W_2 and W3(P >0.05).It illustrated that excessive nitrogen fertilization and supplemental irrigation did not significantly affect plant height and leaf area of winter wheat.(ii) Under the same nitrogen fertilization level,yield increase effect of winter wheat by supplemental irrigation showed a declining trend with nitrogen application amount increased.It illustrated that nitrogen fertilization and supplemental irrigation had certain critical values on the yield of winter wheat.When surpassing the critical value,the yield declined.When nitrogen fertilization amount was 195 kg/hm^2,and supplemental irrigation amount was 70% of field moisture capacity(569.4 m^3/hm^2),the highest yield 8500 kg/hm^2 could be obtained.(iii) During mature period of winter wheat,nitrogen accumulation amount of plant treated by nitrogen was significantly higher than that not treated by nitrogen(P <0.05).But under the treatments of W_2 and W3,nitrogen accumulation amount in N_(255) significantly declined when compared with N_(195)(P <0.05).Especially under W3(873.45 m^3/hm^2) level,nitrogen accumulation amount in N_(255) was even lower than N_0.Under the treatments of N_0 and N_(195),nitrogen accumulation amount of plant significantly increased with supplemental irrigation increased(P < 0.05).But under N_(255) treatment,there was not significant difference(P > 0.05).It illustrated that moderate supplemental irrigation and nitrogen fertilization could improve nitrogen absorption ability of winter wheat,but excessive supplemental irrigation and nitrogen fertilization were not favorable for plant's nitrogen absorption.(iv) Although the increase of supplemental irrigation during jointing period improved nitrogen absorption ability of winter wheat and promoted winter wheat absorbing more nitrogen,it inhibited nitrogen transferring and distributing to seed.Comprehensively considering growth condition of winter wheat and nitrogen risk condition,it is suggested that nitrogen application amount was 195 kg/hm^2,and supplemental irrigation reached 70% of field moisture capacity(569.4 m^3/hm^2),which could be as the suitable water and fertilizer use amounts in the region.
文摘The experimental investigation of unsteady complex flow fields in wind tunnels requires advanced measurement techniques. The most important of such image based measurement techniques are those for the measurement of planar flow velocity fields, planar pressure distribution, model location and deformation, model temperature and quantitative high speed flow visualization. The applications as carried out by DLR range from low speed flows to transonic flows, from high lift configurations to propellers and rotors, from wake vortex investigations in catapult facilities and water towing tanks to investigations of vortex break down phenomena on delta wings. The capability to use image based measurement techniques in transonic flows requires dedicated technical developments and experienced scientists due to the special environment of a transonic wind tunnel. In this paper an overview of the state-of-the art of the application of image based measurement techniques in transonic flows as performed by DLR's Institute of Aerodynamics and Flow Technology will be given.
基金Supported by the National Natural Science Foundation of China under Grant Nos 11305156 and 11305159
文摘One of the most challenging tasks in the laser-driven Hugoniot experiment is how to increase the reproducibility and precision of the experimental data to meet the stringent requirement in validating equation of state models. In such cases, the contribution of intrinsic uncertainty becomes important and cannot be ignored. A detailed analysis of the intrinsic uncertainty of the aluminum-iron impedance-match experiment based on the measurement of velocities is presented. The influence of mirror-reflection approximation on the shocked pressure of Fe and intrinsic uncertainties from the equation of state uncertainty of standard material are quantified, Furthermore, the comparison of intrinsic uncertainties of four different experimental approaches is presented. It is shown that, compared with other approaches including the most widely used approach which relies on the measurements of the shock velocities of AI and Fe, the approach which relies on the measurement of the particle velocity of Al and the shock velocity of Fe has the smallest intrinsic uncertainty, which would promote such work to significantly improve the diagnostics precision in such an approach.
基金Supported by the National Basic Research Program of China(No 2011CB921200)the Strategic Priority Research Program(B)of the Chinese Academy of Sciences under Grant (No XDB01030200)+1 种基金the National Natural Science Foundation of China(No11374290)the Fundamental Research Funds for the Central Universities and the Foundation for Authors of National Excellent Doctoral Dissertation of China
文摘The maximum entangled number state (NOON state) can improve the sensitivity of physical quantity measure- ment to the Heisenberg limit 1/N. In this work, the magnetic field measurement based on the individual solid spin NOON state is investigated. Based on the tunable effective coupling coefficient, we propose a generation scheme of the three-spin NOON state, i.e, the Creenberger-Horne-Zeilinger (CHZ) state, and discussed the mea- surement resolution reduction due to decoherence. It is unnecessary to entangle spins as many as possible when decoherence exists. In practice, defect spins in diamond and alp donors with long coherence time can be applied with current techniques in the nano-scaled high resolution magnetic measurement.
基金a grant fromTackle Key Problems in Sci-ence and Technology of FoshanCity, No. 200505075
文摘BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacial neuralgia from the experience of puncture operator only to puncture by taking the objective data of measurement as the evidence, which is good for improving the accuracy of puncturing trigeminal ganglion and reducing side effects. OBJECTIVE : To observe the forms of foramen ovales in healthy adults displayed by volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan of skull base, and measure the longitudinal diameter and transverse diameter. DESIGN : A repetitive observation and measurement SETTINGS : Department of Neurosurgery and Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine. PARTICIPANTS: Fifty healthy adults (100 sides), who were examined with three-dimensional spiral CT scan, were randomly selected from the Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine from January 2005 to January 2006, including 26 males and 24 females, aged 25-68 years with an average of 48 years old. They were all informed and agreed with the examination. METHODS : The subjects were examined with the Philips 16-slice spiral CT-Mx 8000 IDT CT apparatus (Philips Company, Holland), the scanning ranged from 2 cm below the canthomeatal line to the level of suprasellar cistem. The width of collimator was 0.75 mm, pitch was 0.663; tube current was 350 mA, voltage was 120 kV, resolution was 512×512 matrix; slice thickness of reconstruction was 1 mm, and interval was 0.5 mm. After the three-dimensional spiral CT thin-slice scan of skull base, the image post-processing techniques including volume rendering and multi-planar reconstruction were applied to observe the forms of foramen ovales, and measure the size, longitudinal diameter and transverse diameter of the foramen ovales. The figures of the foramen ovales were drawn with mouse along the boundary of bone porous margin and soft tissue. According to the indications, the diameters were measured with computer to observe the forms of foramen ovales. MAIN OUTCOME MEASURES : The longitudinal diameter, transverse diameter and form of foramen ovales were observed. RESULTS: All the 50 healthy adults (100 sides) were involved in the analysis of results. (1) It was observed in the volume rendering images that foramen ovales had four forms of oval shape (77 sides), kidney shape (12 sides), round shape (7 sides), ribbon shape (4 sides). (2) The longitudinal diameters of left and right foramen ovales were (7.67±1.32) and (7.98±1.45) mm, and the transverse diameters were (4.04±0.83), (4.09±1.07) mm; There was no obvious difference between left and right longitudinal diameters (t = 1.63, P = 0.11 ), and left and right transverse diameters were close (t = 0.45, P= 0.65). CONCLUSION : The non-invasive techniques of volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan can clearly display the formand size of foramen ovale in healthy adults.
基金the Joint Guidance Project of Natural Science Foundation of Heilongjiang Province(No.LH2021F008)。
文摘Aiming at the approximate measurement of magnetic rotation angle in optical current sensor based on light intensity detection mode,this paper proposes a current measurement method based on triangular constant transformation to reconstruct magnetic rotation angle,so as to avoid the large current measurement error caused by the approximate measurement of the magnetic rotation angle.By extracting the direct current(DC)component and the alternating current(AC)component of the light intensity signal detected by the photoelectric detector(PD),the sine signal containing the magnetic rotation angle is directly obtained by dividing the two components,and then the triangular identity transformation method is used to linearly demodulate the magnetic rotation angle and reconstruct the current waveform.The experimental results show that the relative error of current measurement does not exceed 1.40%in the current range of 0.05—0.50 A,which is less than the approximate linear measurement(ALM)method,and the magnetic rotation angle and the current have a good linear relationship.
文摘A criterion for he tquantum teleportation of an arbitrary N-particle state via a 2N-particle quantum channel is presented by introducing a term of the judgment operator''. Using the criterion, not only the qualitative judgment of the possibility of successful teleportation can be made but also the quantitative calculation of the probability of successful teleportation can be explicitly given. In addition, a new genuine four-qubit entangled state is proposed, which could not belong to the category of previously known states under stochastic local operations and classical communication.
文摘运用含非期望产出的超效率SBM(slack based measure)模型和GML(global Malmquist-Luenberger)指数,对中国与世界主要国家1991—2016年的分别在考虑和不考虑环境约束下的技术效率和全要素生产率进行测度与比较。研究发现,不考虑环境约束的测度结果忽略了一国发展所造成的污染损失,导致技术效率与生产率被高估;中国的技术效率在考虑环境因素后显著下降,总效率排名从样本中的第16位下降至第40位。时间趋势上,中国的环境效率与技术效率的差距呈现先扩大后缩小,且近年来有逐渐趋同的态势;动态视角上,不考虑环境约束时中国的全要素生产率变化总体呈现增长趋势,但在考虑环境因素后中国的环境全要素生产率转变为下降趋势,这其中,技术进步的下降是影响环境全要素生产率变化的主要因素。
基金Supported by the National Natural Science Foundations of China under Grant Nos. 10904066 and 11004096the State Key Program for Basic Research of China under Grant No. 2011CBA00205
文摘We propose two schemes for realizing quantum secure direct communication (QSDC)by using a set ofordered two-photon three-dimensional hyperentangled states entangled in two degrees of freedom (DOFs)as quantuminformation channels.In the first scheme,the photons from Bob to Alice are transmitted only once.After insuring thesecurity of the quantum channels,Bob encodes the secret message on his photons.Then Alice performs single-photontwo-DOF Bell bases measurements on her photons.This scheme has better security than former QSDC protocols.In thesecond scheme,Bob transmits photons to Alice twice.After insuring the security of the quantum channels,Bob encodesthe secret message on his photons.Then Alice performs two-photon Bell bases measurements on each DOF.The schemehas more information capacity than former QSDC protocols.
文摘Various technologies have recently been developed for high-speed railways, in order to boost commercial speeds from 300 km.h: to 400 km.h-1. Among these technologies, this paper introduces the 400 km-h-1 class current collection performance evaluation methods that have been developed and demonstrated by Korea. Specifically, this paper reports details of the video-based monitoring techniques that have been adopted to inspect the stability of overhead contact line (OCL) components at 400 km.h-1 without direct contact with any components of the power supply system. Unlike conventional OCL monitoring systems, which detect contact wire positions using either laser sensors or line cameras, the developed system measures parameters in the active state by video data. According to experimental results that were obtained at a field-test site established at a commercial line, it is claimed that the proposed mea- surement system is capable of effectively measuring OCL parameters.
基金the National Natural Science Foundation of China(No.31101085)the Scientific Research and Development Foundation for Start-up Projects of Zhejiang Agriculture and Forestry University (No.2034020044)
文摘The purpose of this study is to develop a standard methodology for measuring the surface free energy (SFE),and its component parts of bamboo fiber materials.The current methods was reviewed to determine the surface tension of natural fibers and the disadvantages of techniques used were discussed.Although numerous techniques have been employed to characterize surface tension of natural fibers,it seems that the credibility of results obtained may often be dubious.In this paper,critical surface tension estimates were obtained from computer aided machine vision based measurement.Data were then analyzed by the least squares method to estimate the components of SFE.SFE was estimated by least squares analysis and also by Schultz' method.By using the Fowkes method the polar and disperse fractions of the surface free energy of bamboo fiber materials can be obtained.Strictly speaking,this method is based on a combination of the knowledge of Fowkes theory. SFE is desirable when adhesion is required,and it avoids some of the limitations of existing studies which has been proposed.The calculation steps described in this research are only intended to explain the methods.The results show that the method that only determines SFE as a single parameter may be unable to differentiate adequately between bamboo fiber materials,but it is feasible and very efficient.In order to obtain the maximum performance from the computer aided machine vision based measurement instruments,this measurement should be recommended and kept available for reference.