The in-cylinder flow field of the internal combustion engine is an important factor affecting the quality and combustion quality of the fuel mixture in the cylinder. In order to calculate the high-precision flow field...The in-cylinder flow field of the internal combustion engine is an important factor affecting the quality and combustion quality of the fuel mixture in the cylinder. In order to calculate the high-precision flow field, the paper presents a flow field calculation method based on the optical flow algorithm. The motion of the point was calculated using the change in pixel intensity within two temporally adjacent frame images. The results show the high accuracy and resolution of the flow field at small displacement conditions.展开更多
The angular light-scattering measurement(ALSM) method combined with an improved artificial bee colony algorithm is introduced to determine aerosol optical constants and aerosol size distribution(ASD) simultaneousl...The angular light-scattering measurement(ALSM) method combined with an improved artificial bee colony algorithm is introduced to determine aerosol optical constants and aerosol size distribution(ASD) simultaneously. Meanwhile, an optimized selection principle of the ALSM signals based on the sensitivity analysis and principle component analysis(PCA)is proposed to improve the accuracy of the retrieval results. The sensitivity analysis of the ALSM signals to the optical constants or characteristic parameters in the ASD is studied first to find the optimized selection region of measurement angles. Then, the PCA is adopted to select the optimized measurement angles within the optimized selection region obtained by sensitivity analysis. The investigation reveals that, compared with random selection measurement angles, the optimized selection measurement angles can provide more useful measurement information to ensure the retrieval accuracy. Finally,the aerosol optical constants and the ASDs are reconstructed simultaneously. The results show that the retrieval accuracy of refractive indices is better than that of absorption indices, while the characteristic parameters in ASDs have similar retrieval accuracy. Moreover, the retrieval accuracy in studying L-N distribution is a little better than that in studying Gamma distribution for the difference of corresponding correlation coefficient matrixes of the ALSM signals. All the results confirm that the proposed technique is an effective and reliable technique in estimating the aerosol optical constants and ASD simultaneously.展开更多
We evaluate the applicability of an optical transmission measurement method commonly used for the analysis of the Black Carbon (BC) content of aerosol sample, to determine the BC content of loess sediments. A number o...We evaluate the applicability of an optical transmission measurement method commonly used for the analysis of the Black Carbon (BC) content of aerosol sample, to determine the BC content of loess sediments. A number of different sample pretreatment procedures are developed and compared, leading to an optimum preparation process. The results include: 1) Subtraction of the optical attenuation values before and after heating of the sample filters (“ΔATN”) varies linearly with the sample mass. The slope of the regression line provides the best determination of BC concentration. 2) When the sample mass is small, (NaPO3)6 pretreatment is best for BC measurement, and the BC concentration results are given by the slope of the regression between ΔATN and sample mass, for a series of samples of varying mass. 3) HF pretreatment accompanied by centrifugation and rinsing may produce a negative bias on the result. 4) Replicate measurements of BC for loess samples showed a maximum deviation less than 5.6%, suggesting that measurements of the BC concentration of a sequence of loess samples could determine variations to this degree of significance. 5) The overall trends of BC concentration in loess section sequences were similar for all chemical pretreatments. The BC concentration result for replicate samples is comparable when pretreated by the same procedure.展开更多
Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is...Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is presented. The measurement of upward, downward and net solid fluxes was carried out in a cold model circulating fluidized bed (CFB) unit. The result shows that the profile of the net solid flux is in good agreement with the previous experimental data measured with a suction probe. The comparison between the average solid flux determined with the optical measuring system and the external solid flux was made, and the maximum deviationturned out to be 22%, with the average error being about 6.9%. These confirm that the optical fiber system can be successfully used to measure the upward, downward and net solid fluxes simultaneously by correctly processing the sampling signals obtained from the optical measuring system.展开更多
The principle of an optical method of photocathode processing control, which is one ofphotocathode processing monitoring techniques, is discussed. A designed monitoring apparatus is describedand has been applied to in...The principle of an optical method of photocathode processing control, which is one ofphotocathode processing monitoring techniques, is discussed. A designed monitoring apparatus is describedand has been applied to investigate the optical parameters of multialkali photoemitter during the process offabrication. Some actual schemes using the method to monitor the preparation of photocathodεs are sug-gested.展开更多
Abstract: A micro - power consumption non - contact temperature measuring instrument for big rotor is introduced. As it solves very well the signal coupling under high speed rotation and power supply problem for probe...Abstract: A micro - power consumption non - contact temperature measuring instrument for big rotor is introduced. As it solves very well the signal coupling under high speed rotation and power supply problem for probe, the instrument can realize persistent on - line temperature measurement for big rotor drived by the ordinary light transmitted by optical fiber under the room light.展开更多
Modern industry and science take novel optical measuring systems and laser technologies with high resolution and productivity for solving actual tasks,including safety problems for mining,oil,atomic and railway in-dus...Modern industry and science take novel optical measuring systems and laser technologies with high resolution and productivity for solving actual tasks,including safety problems for mining,oil,atomic and railway in-dustries.The TDI SIE's results in these trends are presented.展开更多
The paper presents a number of signal processing approaches for the spectral interferometric interrogation of extrinsic Fabry-Perot interferometers(EFPIs). The analysis of attainable microdisplacement resolution is pe...The paper presents a number of signal processing approaches for the spectral interferometric interrogation of extrinsic Fabry-Perot interferometers(EFPIs). The analysis of attainable microdisplacement resolution is performed and the analytical equations describing the dependence of resolution on parameters of the interrogation setup are derived. The efficiency of the proposed signal processing approaches and the validity of analytical derivations are supported by experiments. The proposed approaches allow the interrogation of up to four multiplexed sensors with attained resolution between 30 pm and 80 pm, up to three times improvement of microdisplacement resolution of a single sensor by means of using the reference interferometer and noisecompensating approach, and ability to register signals with frequencies up to 1 kHz in the case of 1 Hz spectrum acquisition rate. The proposed approaches can be used for various applications, including biomedical, industrial inspection, and others, amongst the microdisplacement measurement.展开更多
The Electro-optical sampling delay scanning technique can be used for electron beam bunch length measurement. A novel non-synchronous delay scanning technique based on the electro-optical sampling measurements is pres...The Electro-optical sampling delay scanning technique can be used for electron beam bunch length measurement. A novel non-synchronous delay scanning technique based on the electro-optical sampling measurements is presented. Based on Beijing Free Electron Laser (BFEL), the electron beam bunch length was measured with the electro-optical sampling technique for the first time in China. The result shows that the electron beam bunch length at BFEL is about 5.6±1.2 ps.展开更多
An angular light-scattering measurement (ALSM) method combined with the probability density function-bmsed ant colony optimization algorithm (PDF-ACO) is proposed for retrieval of aerosol optical constants. An optimal...An angular light-scattering measurement (ALSM) method combined with the probability density function-bmsed ant colony optimization algorithm (PDF-ACO) is proposed for retrieval of aerosol optical constants. An optimal measurement angle selection method using a principal component analysis (PCA) approach is developed to improve retrieval accuracy. Results indicate that optimized angle selection can ensure retrieval accuracy. The aerosol optical constants over Beijing, China, which are available from the Aerosol Robotic Network (AERONET), are then rec on structed. The ALSM method's con vergence properties are also studied via comparison w让h those of the light reflection-transmittance measurement (LRTM) method. Results retrieved using the ALSM method show better convergence speed and accuracy than those retrieved using the LRTM method because the ALSM method does not require solution of the radiative transfer equation and allows more useful signals to be obtained. Additionally, the inverse accuracy of the refractive index results is better than that of the absorption index results;this is attributed to differences between the monodromic characteristics of the refractive index and absorption index retrieval results. All results confirm that the combination of the ALSM method w让h the PDF-ACO algorithm and the optimal measurement angle selection method provides effective and reliable aerosol optical constant reconstructio n.展开更多
In this Letter, a test method based on oblique incidence is practically implemented in the interferometric measurement process. Three sets of wavefront data are achieved through cavity interference measurement with a ...In this Letter, a test method based on oblique incidence is practically implemented in the interferometric measurement process. Three sets of wavefront data are achieved through cavity interference measurement with a Fizeau interferometer and one oblique incidence measurement. An iterative algorithm is applied to retrieve the absolute surface shape of the test flat. By adding two sets of measurements, the absolute surface error of the interferometer's reference flat can be obtained. The new method can not only calibrate the reference flat error of interferometer, but also provide the absolute measurement method for high precision optical components applied in high power laser systems.展开更多
A non-orthogonal predefined exponential basis set is used to handle half-bounded domains in multi domain spectral method (MDSM). This approach works extremely well for real-valued semi-infinite differential problems. ...A non-orthogonal predefined exponential basis set is used to handle half-bounded domains in multi domain spectral method (MDSM). This approach works extremely well for real-valued semi-infinite differential problems. It spans simultaneously wide range of exponential decay rates with multi scaling and does not suffer from zero crossing. These two conditions are necessary for many physical problems. For comparison, the method is used to solve different problems and compared with analytical and published results. The comparison exhibits the strengths and accuracy of the presented basis set.展开更多
文摘The in-cylinder flow field of the internal combustion engine is an important factor affecting the quality and combustion quality of the fuel mixture in the cylinder. In order to calculate the high-precision flow field, the paper presents a flow field calculation method based on the optical flow algorithm. The motion of the point was calculated using the change in pixel intensity within two temporally adjacent frame images. The results show the high accuracy and resolution of the flow field at small displacement conditions.
基金Project supported by the Jiangsu Provincial Natural Science Foundation,China(Grant Nos.BK20170800 and BK20160794)the National Natural Science Foundation of China(Grant No.51606095)
文摘The angular light-scattering measurement(ALSM) method combined with an improved artificial bee colony algorithm is introduced to determine aerosol optical constants and aerosol size distribution(ASD) simultaneously. Meanwhile, an optimized selection principle of the ALSM signals based on the sensitivity analysis and principle component analysis(PCA)is proposed to improve the accuracy of the retrieval results. The sensitivity analysis of the ALSM signals to the optical constants or characteristic parameters in the ASD is studied first to find the optimized selection region of measurement angles. Then, the PCA is adopted to select the optimized measurement angles within the optimized selection region obtained by sensitivity analysis. The investigation reveals that, compared with random selection measurement angles, the optimized selection measurement angles can provide more useful measurement information to ensure the retrieval accuracy. Finally,the aerosol optical constants and the ASDs are reconstructed simultaneously. The results show that the retrieval accuracy of refractive indices is better than that of absorption indices, while the characteristic parameters in ASDs have similar retrieval accuracy. Moreover, the retrieval accuracy in studying L-N distribution is a little better than that in studying Gamma distribution for the difference of corresponding correlation coefficient matrixes of the ALSM signals. All the results confirm that the proposed technique is an effective and reliable technique in estimating the aerosol optical constants and ASD simultaneously.
文摘We evaluate the applicability of an optical transmission measurement method commonly used for the analysis of the Black Carbon (BC) content of aerosol sample, to determine the BC content of loess sediments. A number of different sample pretreatment procedures are developed and compared, leading to an optimum preparation process. The results include: 1) Subtraction of the optical attenuation values before and after heating of the sample filters (“ΔATN”) varies linearly with the sample mass. The slope of the regression line provides the best determination of BC concentration. 2) When the sample mass is small, (NaPO3)6 pretreatment is best for BC measurement, and the BC concentration results are given by the slope of the regression between ΔATN and sample mass, for a series of samples of varying mass. 3) HF pretreatment accompanied by centrifugation and rinsing may produce a negative bias on the result. 4) Replicate measurements of BC for loess samples showed a maximum deviation less than 5.6%, suggesting that measurements of the BC concentration of a sequence of loess samples could determine variations to this degree of significance. 5) The overall trends of BC concentration in loess section sequences were similar for all chemical pretreatments. The BC concentration result for replicate samples is comparable when pretreated by the same procedure.
文摘Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is presented. The measurement of upward, downward and net solid fluxes was carried out in a cold model circulating fluidized bed (CFB) unit. The result shows that the profile of the net solid flux is in good agreement with the previous experimental data measured with a suction probe. The comparison between the average solid flux determined with the optical measuring system and the external solid flux was made, and the maximum deviationturned out to be 22%, with the average error being about 6.9%. These confirm that the optical fiber system can be successfully used to measure the upward, downward and net solid fluxes simultaneously by correctly processing the sampling signals obtained from the optical measuring system.
文摘The principle of an optical method of photocathode processing control, which is one ofphotocathode processing monitoring techniques, is discussed. A designed monitoring apparatus is describedand has been applied to investigate the optical parameters of multialkali photoemitter during the process offabrication. Some actual schemes using the method to monitor the preparation of photocathodεs are sug-gested.
文摘Abstract: A micro - power consumption non - contact temperature measuring instrument for big rotor is introduced. As it solves very well the signal coupling under high speed rotation and power supply problem for probe, the instrument can realize persistent on - line temperature measurement for big rotor drived by the ordinary light transmitted by optical fiber under the room light.
文摘Modern industry and science take novel optical measuring systems and laser technologies with high resolution and productivity for solving actual tasks,including safety problems for mining,oil,atomic and railway in-dustries.The TDI SIE's results in these trends are presented.
文摘The paper presents a number of signal processing approaches for the spectral interferometric interrogation of extrinsic Fabry-Perot interferometers(EFPIs). The analysis of attainable microdisplacement resolution is performed and the analytical equations describing the dependence of resolution on parameters of the interrogation setup are derived. The efficiency of the proposed signal processing approaches and the validity of analytical derivations are supported by experiments. The proposed approaches allow the interrogation of up to four multiplexed sensors with attained resolution between 30 pm and 80 pm, up to three times improvement of microdisplacement resolution of a single sensor by means of using the reference interferometer and noisecompensating approach, and ability to register signals with frequencies up to 1 kHz in the case of 1 Hz spectrum acquisition rate. The proposed approaches can be used for various applications, including biomedical, industrial inspection, and others, amongst the microdisplacement measurement.
基金Supported by National Natural Science Foundation of China (10575116)
文摘The Electro-optical sampling delay scanning technique can be used for electron beam bunch length measurement. A novel non-synchronous delay scanning technique based on the electro-optical sampling measurements is presented. Based on Beijing Free Electron Laser (BFEL), the electron beam bunch length was measured with the electro-optical sampling technique for the first time in China. The result shows that the electron beam bunch length at BFEL is about 5.6±1.2 ps.
基金the Jiangsu Provin-cial Natural Science Foundation (grant numbers BK20170800, BK20160794)the Fundamental Research Funds for the Central Universities (grant number 1022-YAH16051)and the National Natural Science Foundation of China (grant number 51606095).
文摘An angular light-scattering measurement (ALSM) method combined with the probability density function-bmsed ant colony optimization algorithm (PDF-ACO) is proposed for retrieval of aerosol optical constants. An optimal measurement angle selection method using a principal component analysis (PCA) approach is developed to improve retrieval accuracy. Results indicate that optimized angle selection can ensure retrieval accuracy. The aerosol optical constants over Beijing, China, which are available from the Aerosol Robotic Network (AERONET), are then rec on structed. The ALSM method's con vergence properties are also studied via comparison w让h those of the light reflection-transmittance measurement (LRTM) method. Results retrieved using the ALSM method show better convergence speed and accuracy than those retrieved using the LRTM method because the ALSM method does not require solution of the radiative transfer equation and allows more useful signals to be obtained. Additionally, the inverse accuracy of the refractive index results is better than that of the absorption index results;this is attributed to differences between the monodromic characteristics of the refractive index and absorption index retrieval results. All results confirm that the combination of the ALSM method w让h the PDF-ACO algorithm and the optimal measurement angle selection method provides effective and reliable aerosol optical constant reconstructio n.
基金supported by the National Natural Science Foundation of China(Nos.11602280 and 61705246)
文摘In this Letter, a test method based on oblique incidence is practically implemented in the interferometric measurement process. Three sets of wavefront data are achieved through cavity interference measurement with a Fizeau interferometer and one oblique incidence measurement. An iterative algorithm is applied to retrieve the absolute surface shape of the test flat. By adding two sets of measurements, the absolute surface error of the interferometer's reference flat can be obtained. The new method can not only calibrate the reference flat error of interferometer, but also provide the absolute measurement method for high precision optical components applied in high power laser systems.
文摘A non-orthogonal predefined exponential basis set is used to handle half-bounded domains in multi domain spectral method (MDSM). This approach works extremely well for real-valued semi-infinite differential problems. It spans simultaneously wide range of exponential decay rates with multi scaling and does not suffer from zero crossing. These two conditions are necessary for many physical problems. For comparison, the method is used to solve different problems and compared with analytical and published results. The comparison exhibits the strengths and accuracy of the presented basis set.