期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
内齿行星齿轮传动受力特性的研究 被引量:6
1
作者 张淳 梁治国 《机械传动》 CSCD 北大核心 2000年第3期30-32,共3页
通过对内齿行星齿轮传动在单轴输入和双轴输入两种不同状态下内齿板的受力特性的研究和分析 ,得出一种比较简单、实用的内齿板受力的近似计算方法 ,从而为内齿行星齿轮传动的转臂轴及其轴承上的载荷计算提供了方便。同时 ,研究了在上述... 通过对内齿行星齿轮传动在单轴输入和双轴输入两种不同状态下内齿板的受力特性的研究和分析 ,得出一种比较简单、实用的内齿板受力的近似计算方法 ,从而为内齿行星齿轮传动的转臂轴及其轴承上的载荷计算提供了方便。同时 ,研究了在上述两种输入状态下应采用的内齿板的数目及单轴输入时的原理性载荷不均匀问题。 展开更多
关键词 内齿行星齿轮传动 力分析 内齿板 单轴输入
下载PDF
APPLICATION OF THE PROBABILISTIC FRACTURE MECHANICS METHOD OF PREDICTING THE FATIGUE LIFE OF TUBULAR JOINTS 被引量:1
2
作者 聂国华 翁智远 刘人怀 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1994年第11期1017-1023,共7页
In this paper .fatigue strength of T-type tubularjoints subjected to in-planebending or out-of-plane bending load is investigated By, considering material constantsand initial crack sizes as random variables and appl... In this paper .fatigue strength of T-type tubularjoints subjected to in-planebending or out-of-plane bending load is investigated By, considering material constantsand initial crack sizes as random variables and applying Monte Carlo simulation method, we have giyen a statistical analvsis on fatigue life. Simultaneously, linearregression analyses of computed resuldts are performed and compared with that of theknown experimental data. 展开更多
关键词 Monte Carlo simulation method probabilistie fracture mechani-cs FATIGUE tubular joints
下载PDF
Effects of the ion-beam voltage on the properties of the diamond-like carbon thin film prepared by ion-beam sputtering deposition 被引量:1
3
作者 孙鹏 胡明 +4 位作者 张锋 季一勤 刘华松 刘丹丹 冷健 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期581-585,共5页
Diamond-like carbon (DLC) thin film is one of the most widely used optical thin films. The fraction of chemical bondings has a great influence on the properties of the DLC film. In this work, DLC thin films are prep... Diamond-like carbon (DLC) thin film is one of the most widely used optical thin films. The fraction of chemical bondings has a great influence on the properties of the DLC film. In this work, DLC thin films are prepared by ion-beam sputtering deposition in Ar and CH4 mixtures with graphite as the target. The influences of the ion-beam voltage on the surface morphology, chemical structure, mechanical and infrared optical properties of the DLC films are investigated by atomic force microscopy (AFM), Raman spectroscopy, nanoindentation, and Fourier transform infrared (FTIR) spec- troscopy, respectively. The results show that the surface of the film is uniform and smooth. The film contains sp2 and sp3 hybridized carbon bondings. The film prepared by lower ion beam voltage has a higher sp3 bonding content. It is found that the hardness of DLC films increases with reducing ion-beam voltage, which can be attributed to an increase in the fraction of sp3 carbon bondings in the DLC film. The optical constants can be obtained by the whole infrared optical spectrum fitting with the transmittance spectrum. The refractive index increases with the decrease of the ion-beam voltage, while the extinction coefficient decreases. 展开更多
关键词 DLC thin film ion-beam sputtering deposition chemical bondings infrared optical and mechani-cal properties
下载PDF
POST-DEFORMATION TENSILE PROPERTIES IN A RAPIDLY SOLIDIFIED POWDER METALLURGY MR64 ALLOY
4
作者 Cui,Zhongqi Liang,Tongxiang +1 位作者 Chen, Puquan Zhang,Jiren(Harbin Institute of Technology,Harbin 150001 ,China)Lu,Yuxiong Ma,Zhongyi(Instdute of Metal Research, Acatlentia Sinica,Shenyang 110006 ,China) 《中国有色金属学会会刊:英文版》 CSCD 1994年第1期80-84,90,共6页
POSTDEFORMATIONTENSILEPROPERTIESINARAPIDLYSOLIDIFIEDPOWDERMETALLURGYMR64ALLOYOCui,Zhongqi;Liang,Tongxiang;Ch... POSTDEFORMATIONTENSILEPROPERTIESINARAPIDLYSOLIDIFIEDPOWDERMETALLURGYMR64ALLOYOCui,Zhongqi;Liang,Tongxiang;Chen,Puquan;Zhang,J... 展开更多
关键词 : MR64 ALLOY rapid solidification POWDER METALLURGY SUPERPLASTICITY mechani-cal PROPERTIES cavity
下载PDF
Comparison of the early curative effect in patients undergoing mechanical vs. bioprosthetic aortic valve replacement with concomitant annuloplasty by the Nicks procedure
5
作者 吴浩 向鸿谟 +1 位作者 王露 朱平 《South China Journal of Cardiology》 CAS 2024年第1期29-37,共9页
Background The probability of prosthesis-patient mismatch(PPM)is high in aortic valve replacement surgery for small aortic valve annulus,which increases the postoperative prosthetic valve transvalvular pressure gradie... Background The probability of prosthesis-patient mismatch(PPM)is high in aortic valve replacement surgery for small aortic valve annulus,which increases the postoperative prosthetic valve transvalvular pressure gradient.Concurrent aortic annuloplasty is a commonly applied surgical procedure,but there is currently no uniform standard or guideline on the type of prosthetic valve that should be used during surgery.Therefore,this study aimed to analyze whether there was any difference in the short-term prognosis between the choice of mechanical valves and bioprosthetic valves during aortic valve replacement surgery with concomitant aortic annuloplasty by the Nicks procedure.Methods A retrospective analysis was conducted based on the clinical data from 55 patients undergoing aortic valve replacement surgery with concomitant annuloplasty by the Nicks procedure at the Cardiac Surgery Department of Guangdong Provincial People’s Hospital from November 2021 to December 2023.In this study,all patients received aortic annuloplasty by the Nicks procedure.Among these patients,30 were in the mechanical valve group,while the other 25 were in the bioprosthetic valve group.Data including left ventricular end-diastolic/endsystolic diameters,left ventricular ejection fraction,interventricular septal thickness,left ventricular posterior wall thickness,transvalvular pressure gradient,left ventricular fractional shortening,and left ventricular mass index were collected 1 week preoperatively and 1 week and 3 months postoperatively.Information on gender,age,body surface area,types of perioperative complications,operation time,complication rates,and outcomes was also collected.Results Among the 55 patients enrolled in this study,4 died.The main causes of death included postoperative low cardiac output syndrome,severe pulmonary infection,and multi-organ dysfunction.Meanwhile,there was a statistically significant difference in left ventricular end-diastolic diameter between the mechanical valve group and the biological valve group 1 week after surgery.However,differences in other indicators such as aortic crossclamp duration,cardiopulmonary bypass duration,postoperative ventilator support duration,postoperative intensive care unit(ICU)stay,total postoperative hospital stay,and echocardiography results 1 week and 3 months postoperatively were not significant between the two groups.Conclusions For patients undergoing aortic annuloplasty by the Nicks procedure in the aortic valve replacement surgery,the postoperative recovery time is not significantly different between the bioprosthetic and mechanical valve groups.Additionally,there is no notable difference in the improvement of left ventricular function or the reduction of PPM incidence between the two types of valves.[S Chin J Cardiol 2024;25(1):29-37]. 展开更多
关键词 Valve replacement Small aortic annulus Nicks procedure Prosthesis-patient mismatch mechani-cal valve Bioprosthetic valve
原文传递
Characteristics of Joint Welded by Laser Welding of Aluminium-Lithium Alloy with Filler Wire 被引量:1
6
作者 Yang J1,2,Li X Y1,Gong S L2,Chen L2,Xu F2 1 School of Material Science and Engineering,Beijing University of Technology,Beijing 100083,China 2 Science and Technology on Power Beam Processes Laboratory,Beijing Aeronautical Manufacturing Technology Research Institute,Beijing 100024,China 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2011年第S4期138-141,共4页
The characteristics of weld shape,microstructure,mechanical properties and defects of 5A90 Al-Li alloy joint by laser welding (LBW) and laser welding with filler wire (LWFW) were studied and analyzed.The results indic... The characteristics of weld shape,microstructure,mechanical properties and defects of 5A90 Al-Li alloy joint by laser welding (LBW) and laser welding with filler wire (LWFW) were studied and analyzed.The results indicated that the microstructure of joint by LWFW was fine-grained layer and the equiaxed grain in most of seams,which were similar to the joint by LBW.Compared with the joint by LBW,the microstructure of joint by LWFW tended to fine,and the range of the columnar crystals zone was prone to decrease.The Microhardness of the joint by LWFW (92.57HV0.2) was lower than that by LBW (95.65HV0.2),but the uniformity was better.The ultimate tensile strength of the joint by LWFW was lower than that by LBW slightly,which reached to 73.03% and 79.22% of the base metal respectively.However,the elongation of the LWFW joint was higher than that of the LBW joint significantly,which reached to 38.65% and 20.38% of the base metal respectively.The microstructure and mechanical properties of 5A90 Al-Li alloy by LWFW were better than that by LBW.The defects of joint were mainly forming defects which were caused by improper parameters and porosity inside the joint,which was caused by uncleaned surface and incomplete penetration. 展开更多
关键词 AL-LI alloy LASER beam WELDING (LBW) LASER WELDING with FILLER wire (LWFW) weld shape microstructure mechani-cal properties defects
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部