The Effects of Lower Intensity Anticoagulation Therapy on Coagulation System in Patients With Mechanical Prosthetic Valves
1
作者 杜心灵 张凯伦 +3 位作者 胡志伟 蓝鸿钧 罗军 金咏梅 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1999年第1期57-59,共3页
Summary: To evaluate the effect of lower intensity anticoagulation therapy in patients with mechanical prosthetic valves, laboratory based hematological assays including prothrombin time (PT), activity of factor X, a... Summary: To evaluate the effect of lower intensity anticoagulation therapy in patients with mechanical prosthetic valves, laboratory based hematological assays including prothrombin time (PT), activity of factor X, antithrombin Ⅲ (AT Ⅲ), D dimer, fibrinogen (Fg) and platel et al pha granular membrane protein (GMP 140) were performed in 65 patients who had been on warfarin treatment for over one month. The patients were assigned to 3 groups on the basis of their International Normalized Ratios (INR), ranging from 2.00 to 2.50; 2.51 to 3.00; 3.01 to 4.50, respectively. The results showed that the D dimer, Fg, GMP 140 levels were higher after mechanical valve replacement than those before operation, indicating the activation of coagulation and fibrinolysis system and the damage of platelets. Lower intensity anticoagulation therapy (INR 2 00 to 2.50) could effectively inhibit the activity of factor X and increase the level of AT Ⅲ. There were no appreciable differences among D dimer, Fg, GMP 140 and AT Ⅲ in the 3 anticoagulation intensity groups. These results suggest that in patients with new generation mechanical prosthetic valves, target anticoagulation level (INR 2 00 to 2.50) may result in good protection from thrombo embolism. 展开更多
关键词 anticoagulation intensity coagulation system mechanical prosthetic valve
下载PDF
INFLUENCE OF MIMIC CARDIAC RATE ON HYDRODYNAMICS OF DIFFERENT MECHANICAL PROSTHETIC CARDIAC VALVES IN VITRO 被引量:2
2
作者 Yin-pingChu Jin-lianCheng +2 位作者 Ru-kunChen Yu-boFan FangPu 《Chinese Medical Sciences Journal》 CAS CSCD 2005年第2期138-141, ,共4页
Objective To assess the influence of mimic cardiac rate on hydrodynamics of different mechanical prosthetic cardiac valves. Methods US-made CarboMedics bileaflet valve, China-made Jiuling bileaflet valve and C-L tilti... Objective To assess the influence of mimic cardiac rate on hydrodynamics of different mechanical prosthetic cardiac valves. Methods US-made CarboMedics bileaflet valve, China-made Jiuling bileaflet valve and C-L tilting disc valve were tested via a pulsatile flow simulator in the aortic position. Testing conditions were set at mimic cardiac rates of 55 bpm, 75 bpm, 100 bpm with a constant mimic cardiac output of 4 L/min. The mean pressure differences (ΔP), leakage volumes (LEV) and closing volumes (CLV) across each valve, and effective orifice areas (EOA) were analyzed. Results Within physiological range, ΔP, LEV, and CLV decreased as mimic cardiac rate increased, with a large extent of variance. EOA increased along with an increase in mimic cardiac rate. It was a different response in terms of cardiac rate alteration for different types of mechanical prosthetic cardiac valves. Conclusion Mimic cardiac rate change affects hydrodynamics of mechanical prosthetic cardiac valves. Within physiological range, the hydrodynamic of prosthetic bileaflet valve is better than that of tilting disc valve. 展开更多
关键词 mimic cardiac rate mechanical prosthetic cardiac valves HYDRODYNAMICS