A novel voltammetric sensor based on gold nanoparticles (GNPs) and single-walled carbon nanotubes (SWNTs) composite was developed. The nanocomposite modified electrode was characterized using atoms force microscope (A...A novel voltammetric sensor based on gold nanoparticles (GNPs) and single-walled carbon nanotubes (SWNTs) composite was developed. The nanocomposite modified electrode was characterized using atoms force microscope (AFM). The electrochemical behavior of meclofenoxate hydrochloride (MFX) was investigated on this sensor. The results indicated that the GNPs/SWNTs modified electrode exhibited efficient electrocatalytic oxidation for MFX with relatively high sensitivity, and stability. Using square wave voltammetry (SWV), the GNPs/SWNTs modified electrode exhibited a linear voltammetric response for MFX in the concentration range of 5.0 × 10–7 – 2.0 × 10–5mol·L–1, with the limit of detection (LOD) of 1.0 × 10–7 mol·L–1. The sensor was applied to determine MFX in finished drug with a satisfactory result.展开更多
Two simple and rapid analytical methods (DSC and <sup>1</sup>H-NMR), are proposed for determination of meclofenoxate in meclofenoxate hydrochloride for injection. DSC thermogram is recorded without any sam...Two simple and rapid analytical methods (DSC and <sup>1</sup>H-NMR), are proposed for determination of meclofenoxate in meclofenoxate hydrochloride for injection. DSC thermogram is recorded without any sample pretreatment. The response linearity is ensured by linear determination factors R<sup>2</sup>, which is 0.9982. The recoveries of meclofenoxate hydrochloride in sterile powder for injection are from 98.3% to 102.3% (n = 3). The quantitative <sup>1</sup>H-NMR is quick and simple to use. The quantitation of meclofenoxate is reproducible and the relative standard deviation is 1.0%. The accuracy of two methods is validated by comparison with the results obtained by HPLC. The results show that the two methods are capable of quantifying the content of meclofenoxate in meclofenoxate hydrochloride for injection.展开更多
文摘A novel voltammetric sensor based on gold nanoparticles (GNPs) and single-walled carbon nanotubes (SWNTs) composite was developed. The nanocomposite modified electrode was characterized using atoms force microscope (AFM). The electrochemical behavior of meclofenoxate hydrochloride (MFX) was investigated on this sensor. The results indicated that the GNPs/SWNTs modified electrode exhibited efficient electrocatalytic oxidation for MFX with relatively high sensitivity, and stability. Using square wave voltammetry (SWV), the GNPs/SWNTs modified electrode exhibited a linear voltammetric response for MFX in the concentration range of 5.0 × 10–7 – 2.0 × 10–5mol·L–1, with the limit of detection (LOD) of 1.0 × 10–7 mol·L–1. The sensor was applied to determine MFX in finished drug with a satisfactory result.
文摘Two simple and rapid analytical methods (DSC and <sup>1</sup>H-NMR), are proposed for determination of meclofenoxate in meclofenoxate hydrochloride for injection. DSC thermogram is recorded without any sample pretreatment. The response linearity is ensured by linear determination factors R<sup>2</sup>, which is 0.9982. The recoveries of meclofenoxate hydrochloride in sterile powder for injection are from 98.3% to 102.3% (n = 3). The quantitative <sup>1</sup>H-NMR is quick and simple to use. The quantitation of meclofenoxate is reproducible and the relative standard deviation is 1.0%. The accuracy of two methods is validated by comparison with the results obtained by HPLC. The results show that the two methods are capable of quantifying the content of meclofenoxate in meclofenoxate hydrochloride for injection.