An integration processing system of three-dimensional laser scanning information visualization in goaf was developed. It is provided with multiple functions, such as laser scanning information management for goaf, clo...An integration processing system of three-dimensional laser scanning information visualization in goaf was developed. It is provided with multiple functions, such as laser scanning information management for goaf, cloud data de-noising optimization, construction, display and operation of three-dimensional model, model editing, profile generation, calculation of goaf volume and roof area, Boolean calculation among models and interaction with the third party soft ware. Concerning this system with a concise interface, plentiful data input/output interfaces, it is featured with high integration, simple and convenient operations of applications. According to practice, in addition to being well-adapted, this system is favorably reliable and stable.展开更多
AIM: To develop a novel three-dimensional(3D) electric ophthalmotrope to improve the ophthalmology teaching effectiveness and evaluate the teaching value. METHODS: A 3D electric ophthalmotrope was designed by simulati...AIM: To develop a novel three-dimensional(3D) electric ophthalmotrope to improve the ophthalmology teaching effectiveness and evaluate the teaching value. METHODS: A 3D electric ophthalmotrope was designed by simulating the movement of the ocular and the extraocular muscles according to Sherrington’s law. The model with joint bearing was to ensure the flexibility and centripetal rotation of the simulated ball and stepper motor as the driving device. A programmable processor was used to control the motion amplitude of the stepper motor. The size of hole was set at the back of the simulated shell to limit the amount of eye movement. Afterwards, using a 5-point Likert scale, 7 experts evaluated the 3D electric ophthalmotrope’s simulation ability and precision, compared with the traditional anatomical model. In addition, the teaching effectiveness of the 3D electric ophthalmotrope was evaluated at in-class quiz and final exam in a randomized controlled trial. RESULTS: The 3D electric ophthalmotrope could be operated easily to demonstrate the eye movements with motion of different ocular muscles. The experts agreed that the 3D electric ophthalmotrope was different from the traditional model and was easier for students to understand every extraocular muscles’ movement in each evaluation index(P<0.05). Moreover, the results of teaching effectiveness showed that the 3D electric ophthalmotrope were significantly greater than the traditional model both at in-class quiz(P<0.01) and final exam(P<0.05). CONCLUSION: This novel 3D electric ophthalmotrope is better than the traditional model, which can be to improve the ophthalmology teaching effectiveness for students to understand the extraocular muscles’ movement.展开更多
基金Project(51274250)supported by the National Natural Science Foundation of ChinaProject(2012BAK09B02-05)supported by the National Key Technology R&D Program during the 12th Five-year Plan of China
文摘An integration processing system of three-dimensional laser scanning information visualization in goaf was developed. It is provided with multiple functions, such as laser scanning information management for goaf, cloud data de-noising optimization, construction, display and operation of three-dimensional model, model editing, profile generation, calculation of goaf volume and roof area, Boolean calculation among models and interaction with the third party soft ware. Concerning this system with a concise interface, plentiful data input/output interfaces, it is featured with high integration, simple and convenient operations of applications. According to practice, in addition to being well-adapted, this system is favorably reliable and stable.
基金Supported by the National Natural Science Foundation of China (No.30901655)Shaanxi Provincial Key Research and Development Program (No.2018SF-230)
文摘AIM: To develop a novel three-dimensional(3D) electric ophthalmotrope to improve the ophthalmology teaching effectiveness and evaluate the teaching value. METHODS: A 3D electric ophthalmotrope was designed by simulating the movement of the ocular and the extraocular muscles according to Sherrington’s law. The model with joint bearing was to ensure the flexibility and centripetal rotation of the simulated ball and stepper motor as the driving device. A programmable processor was used to control the motion amplitude of the stepper motor. The size of hole was set at the back of the simulated shell to limit the amount of eye movement. Afterwards, using a 5-point Likert scale, 7 experts evaluated the 3D electric ophthalmotrope’s simulation ability and precision, compared with the traditional anatomical model. In addition, the teaching effectiveness of the 3D electric ophthalmotrope was evaluated at in-class quiz and final exam in a randomized controlled trial. RESULTS: The 3D electric ophthalmotrope could be operated easily to demonstrate the eye movements with motion of different ocular muscles. The experts agreed that the 3D electric ophthalmotrope was different from the traditional model and was easier for students to understand every extraocular muscles’ movement in each evaluation index(P<0.05). Moreover, the results of teaching effectiveness showed that the 3D electric ophthalmotrope were significantly greater than the traditional model both at in-class quiz(P<0.01) and final exam(P<0.05). CONCLUSION: This novel 3D electric ophthalmotrope is better than the traditional model, which can be to improve the ophthalmology teaching effectiveness for students to understand the extraocular muscles’ movement.