Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)s...Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC.展开更多
首先介绍了中压电力线信道噪声通用模型,对现场采集的噪声进行互相关系数计算,并采用对称分量法进行相关性分析,得出三相电力系统相间噪声具有一定相关性的结论。改变单相传输模式,根据两相噪声的一致性特点,提出基于自适应最小均方误差...首先介绍了中压电力线信道噪声通用模型,对现场采集的噪声进行互相关系数计算,并采用对称分量法进行相关性分析,得出三相电力系统相间噪声具有一定相关性的结论。改变单相传输模式,根据两相噪声的一致性特点,提出基于自适应最小均方误差(least-mean-square error,LMS)算法实现中压电力线通信(medium voltage power line communication,MV-PLC)的噪声对消。自适应LMS算法虽然收敛速度较慢,但是计算量小,易于实现。仿真结果表明,噪声对消方法的采用有效改善了10kV中压电力线的信噪比,为10kV配网自动化系统采用载波通信技术提供了新的实现途径。展开更多
The past decade has been very busy and exciting times for the underground power cable industry.This paper starts with a brief introduction of the past 100 years and then reviews papers presented at recent JICABLE and ...The past decade has been very busy and exciting times for the underground power cable industry.This paper starts with a brief introduction of the past 100 years and then reviews papers presented at recent JICABLE and CIGRE conferences.Over the past decade both on-line and off-line diagnostics have seen rapid development,HVDC cables have extended interconnection lengths to 600 km and HVAC cables are now commonly installed for distances up to 100 km.And at the same time advanced materials,higher operating voltages and improved cable accessory designs have supported all of these advances.In short,it is an excellent time to review underground power cable technology.展开更多
文摘Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC.
文摘首先介绍了中压电力线信道噪声通用模型,对现场采集的噪声进行互相关系数计算,并采用对称分量法进行相关性分析,得出三相电力系统相间噪声具有一定相关性的结论。改变单相传输模式,根据两相噪声的一致性特点,提出基于自适应最小均方误差(least-mean-square error,LMS)算法实现中压电力线通信(medium voltage power line communication,MV-PLC)的噪声对消。自适应LMS算法虽然收敛速度较慢,但是计算量小,易于实现。仿真结果表明,噪声对消方法的采用有效改善了10kV中压电力线的信噪比,为10kV配网自动化系统采用载波通信技术提供了新的实现途径。
文摘The past decade has been very busy and exciting times for the underground power cable industry.This paper starts with a brief introduction of the past 100 years and then reviews papers presented at recent JICABLE and CIGRE conferences.Over the past decade both on-line and off-line diagnostics have seen rapid development,HVDC cables have extended interconnection lengths to 600 km and HVAC cables are now commonly installed for distances up to 100 km.And at the same time advanced materials,higher operating voltages and improved cable accessory designs have supported all of these advances.In short,it is an excellent time to review underground power cable technology.