期刊文献+
共找到3,431篇文章
< 1 2 172 >
每页显示 20 50 100
Nonlinear Response Analysis for Insulation Diagnosis of Water-tree Aged 10 kV XLPE Cable Using Pulse Voltage 被引量:3
1
作者 DU Boxue WANG Li 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1852-1857,共6页
The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged ... The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged 10 kV XLPE cables were diagnosed. The cables were subjected to electrical stress of 5.9 kV/mm and a thermal load cycle in a curved water-filled tube for 3, 6 and 12 months of aging in accor- dance with the accelerated water-tree test method. The aged cables were used as the samples for water-tree diagnosis. First, the water-tree degraded cable, was charged by a DC voltage, and then the cable was grounded while a pulse voltage was applied to it for releasing the space charge trapped in the water trees. The amount of the space charge, which corresponds to the deterioration degree of the water trees, was calculated. The effects of DC voltage amplitude, pulse voltage repetition rate and aging conditions on the amount of the space charge were studied. Obtained results show that the amount of the space charge has a positive correlation with the applied DC voltage and the ag- ing time of the cables, and that a peak value of space charge appears with the increase of the pulse voltage repetition rate. An optimum pulse voltage repetition rate under which the space charge can be released rapidly is obtained. Furthermore, the releasing mechanism of space charge by the pulse voltage is discussed. Accumulated results show that the presented method has a high resolution for the diagnosis of water tree degradation degree and is expected to be applied in practice in future. 展开更多
关键词 交联聚乙烯电缆 脉冲电压 绝缘诊断 非线性响应 水树 交联聚乙烯绝缘电缆 空间电荷 电缆老化
下载PDF
Aspects of High Voltage Cable Sections in Modern Overhead Line Transmission Systems
2
作者 T. Judendorfer S. Pack M. Muhr 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2732-2738,共7页
Electrical power transmission is dominated by overhead line systems at present.This is mainly based on more than hundred years of experience of utilities in running overhead lines.Furthermore,overhead lines have prove... Electrical power transmission is dominated by overhead line systems at present.This is mainly based on more than hundred years of experience of utilities in running overhead lines.Furthermore,overhead lines have proven their operational reliability and functional assurance.In the past,cables were used in distribution networks in urban areas for the most part with the exception of direct current submarine cables.New developments of high voltage XLPE cables make it possible to use this technology for EHV level applications in transmission networks.Within this paper,mixed network configurations,consisting of overhead lines and high voltage cables,are investigated.An exemplary EHV transmission line with a total length of about 100 km,which is quite typical for Central Europe,has been studied.Several different line combinations are discussed with varied rates between overhead line sections and cable sections length in practice.The length of the cable sections are ranging from several kilometers up to lengths of 100 km.In this paper the work focuses on the transient behavior of combined 400 kV overhead and cable lines during switching processes and lightning impacts.A number of calculations were carried out to get an overview of the transient stress in numerous network nodes along the transmission system.Numerical programs like ATP/EMTP have been used for these simulations.Peak values and wave shapes of the transient voltage stress have been evaluated,based on different systems and within possible combinations.In respect of the insulation coordination and transient stress at network nodes,the voltage-time trends are also analyzed.The combination of high voltage overhead and cable transmission systems,especially such with lengths of more than about 50 km,are making tightened and extended demands to the network design,to the operational management and of course to the network protection also.As an output of this investigations,the results might influence the strategy in running this new type of combined transmission systems. 展开更多
关键词 架空线路 输电系统 高压电缆 配电 绝缘体 混合系统
下载PDF
Statistical Characteristics of Partial Discharge Caused by Typical Defects in Cable Joint under Oscillating Voltage
3
作者 Guangmao Li Zuwei Luo +2 位作者 Jun Xiong Zucheng Huang Yajun Wang 《Journal of Energy and Power Engineering》 2015年第3期310-316,共7页
The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artifi... The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artificial defect models of cable joints in 10 kV XLPE cable. Oscillating voltage is applied to the model, by use of pulse current method to detect partial discharge signals. In order to study the statistical characteristics of partial discharge of cable joint under the oscillating voltage, three-dimensional statistical map has been made. The results show that for the same kind of defects, with the increases of the defect severity, the discharge interval extended, the magnitude and the number of partial discharge increase, for different kinds of defects, obvious differences exist among the maps, this may established a foundation for the further study of the partial discharge pattern recognition of XLPE cable under oscillating voltage. 展开更多
关键词 XLPE cable cable joint defect model partial discharge oscillating voltage three-dimensional statistical map.
下载PDF
The Use of Life Cycle Cost Analysis to Determine the Most Effective Cost of Installation High Voltage Undersea Cable Bali Strait
4
作者 Ngapuli Sinisuka lqbal Felani Novrizal Erdiansyah 《Journal of Energy and Power Engineering》 2012年第12期2082-2089,共8页
Indonesian National Electricity Company (PT.PLN (Persero)) has planned to install additional high voltage undersea cable for circuit llI and IV Java-Bali to fulfill electricity demand in Bali. This project was mor... Indonesian National Electricity Company (PT.PLN (Persero)) has planned to install additional high voltage undersea cable for circuit llI and IV Java-Bali to fulfill electricity demand in Bali. This project was more prefered compared to building another power plant in Bali which could raise social and cultural resistance. Life cycle cost method was used to complete the financial feasibility study to ensure if the project has economic benefit, and the asset would be used effectively and efficiently along its benefit period. In this paper, a life cycle cost will be simulated to analyze which alternative is the most profitable: installation circuit III and IV in 2012 or installation circuit III in 2012 and circuit IV in 2017 in accordance with load forecasting demand. This study is used to help the management to make a decision about the project. 展开更多
关键词 Financial feasibility life cycle cost high voltage undersea cable installation.
下载PDF
Performance Evaluation for Medium Voltage MIMO-OFDM Power Line Communication System 被引量:10
5
作者 Yingxue Li Min Zhang +3 位作者 Wenguang Zhu Mengyuan Cheng Cheng Zhou Yongpeng Wu 《China Communications》 SCIE CSCD 2020年第1期151-162,共12页
Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)s... Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC. 展开更多
关键词 power line communication(PLC) MIMO-OFDM multi-conductor medium voltage underground cables turbo code
下载PDF
Key technologies for medium and low voltage DC distribution system 被引量:6
6
作者 Yiwen Fan Yongning Chi +4 位作者 Yan Li Zhibing Wang Hongzhi Liu Wei Liu Xiangyu Li 《Global Energy Interconnection》 CAS CSCD 2021年第1期91-103,共13页
Development of the medium and low voltage DC distribution system is of great significance to a regional transmission of electric energy,increasing a penetration rate of new energy,and enhancing a safety of the operati... Development of the medium and low voltage DC distribution system is of great significance to a regional transmission of electric energy,increasing a penetration rate of new energy,and enhancing a safety of the operation of the AC/DC interconnected grid.This paper first summarizes the medium and low voltage DC distribution system schemes and plans put forward by many countries,and then elaborate status of under-construction medium and low voltage DC distribution system project cases in China.Based on these project cases,this paper analyzes key issues involved in the medium and low voltage DC distribution system topologies,equipment,operation control technologies and DC fault protections,in order to provide theoretical and technical reference for future medium and low voltage DC distribution system-related projects.Finally,this paper combines a current China research status to summarize and give a prediction about the future research direction of medium and low voltage DC distribution system,which can provide reference for the research of medium and low voltage DC distribution system. 展开更多
关键词 medium and low voltage DC distribution system System topology Key equipment DC fault protection Operation control technology
下载PDF
A Novel Serial Hybrid Three-level NPC Topology for Multi-MW Medium Voltage Wind Power Converters 被引量:5
7
作者 CHEN Gen WANG Yong CAI Xu 《中国电机工程学报》 EI CSCD 北大核心 2013年第9期I0007-I0007,共1页
提出一种新型的串联混合三电平中点钳位(neutralpoint clamped,NPC)拓扑,该拓扑是基于传统三电平NPC拓扑的改进和优化,引入大功率IGBT的串联应用。该新型拓扑中,桥臂的两个外管分别用两个低压IGBT串联,两个内管均用高压IGBT。在多兆... 提出一种新型的串联混合三电平中点钳位(neutralpoint clamped,NPC)拓扑,该拓扑是基于传统三电平NPC拓扑的改进和优化,引入大功率IGBT的串联应用。该新型拓扑中,桥臂的两个外管分别用两个低压IGBT串联,两个内管均用高压IGBT。在多兆瓦级中压风电变流器中,大功率IGBT的开关损耗很大,从而限制了开关频率。提出的新型拓扑通过低压IGBT的串联来减小功率器件的损耗,从而提高开关频率,同时可减小输出滤波器的尺寸。通过传统三电平拓扑和新型串联混合三电平拓扑IGBT损耗的对比,说明新拓扑的优势。通过改变门极驱动电阻实现串联IGBT的均压,对新拓扑的应用具有重大意义。最后通过新拓扑的单相样机验证新拓扑的正确性和可行性。 展开更多
关键词 电压转换器 拓扑结构 风力发电 中压 NPC 三电平 混合 串联
下载PDF
Development of a Medium Voltage, High Power, High Frequency Four-Port Solid State Transformer 被引量:1
8
作者 Ahmad El Shafei Saban Ozdemir +2 位作者 Necmi Altin Garry Jean-Pierre Adel Nasiri 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第1期95-104,共10页
The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies.For that,the need for the development of a compact and highly efficie... The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies.For that,the need for the development of a compact and highly efficient solid-state transformer is becoming a critical task in-order to integrate the current AC grid with the new renewable energy systems.The objective of this paper is to present the design,implementation,and testing of a compact multi-port solid-state transformer for microgrid integration applications.The proposed system has a four-port transformer and four converters connected to the ports.The transformer has four windings integrated on a single common core.Thus,it can integrate different renewable energy resources and energy storage systems.Each port has a rated power of 25 kW,and the switching frequency is pushed to 50 k Hz.The ports are chosen to represent a realistic industrial microgrid model consisting of grid,energy storage system,photovoltaic system,and load.The grid port is designed to operate at 4.16 k VAC corresponding to 7.2 kV DC bus voltage,while the other three ports operate at 500 VDC.Moreover,the grid,energy storage and photovoltaic ports are active ports with dual active bridge topologies,while the load port is a passive port with full bridge rectifier one.The proposed design is first validated with simulation results,and then the proposed transformer is implemented and tested.Experimental results show that the designed system is suitable for 4.16 k VAC medium voltage grid integration. 展开更多
关键词 CO-SIMULATION high frequency high power medium voltage MICROGRID MULTI-PORT solid state transformer
下载PDF
Multilevel Current Source Converters for High Power Medium Voltage Applications 被引量:1
9
作者 Li Ding Yujuan Lian Yun Wei Li 《CES Transactions on Electrical Machines and Systems》 2017年第3期306-314,共9页
In medium voltage high power applications,multi-level current source converters(CSCs)are good candidate to increase system power region,reliability,and the quality of output waveforms.Compared with widely researched v... In medium voltage high power applications,multi-level current source converters(CSCs)are good candidate to increase system power region,reliability,and the quality of output waveforms.Compared with widely researched voltage source multi-level converters(MLCs),the current source MLCs have the advantages of inherent short-circuit protection,high power capability and high quality of output current waveforms.The main features of MLCs include reduced harmonics,lower switching frequency and reduced current stress on each device which is a particularly important for high power application with low voltage and high current requirements.This paper conducts a general review of the current research about MLCs in higher power medium voltage application.The different types of parallel structure based MLCs and the modulation methodologies will be introduced and compared.Specifically,the circuit analysis of the common-mode(CM)loop for parallel structures will be conducted,the common-mode voltage(CMV)and circulating current suppression methods developed on the base of multilevel modulations will be addressed. 展开更多
关键词 Circulating current common-mode voltage current source converters multi-level converter high power medium voltage parallel structure
下载PDF
The Optimization on Operation Characteristicsof Urban Medium Voltage Network
10
作者 Yao Huannian Cao Meiyue(Xiamen Electric Power Administration, Xiamen) 《Electricity》 1998年第3期27-29,共3页
Traditional small current grounding system has many advantages. Pilot operation shows that optimized one has even better operation characteristics. It has proven to be a geenrallly properand relatively perfect neutyal... Traditional small current grounding system has many advantages. Pilot operation shows that optimized one has even better operation characteristics. It has proven to be a geenrallly properand relatively perfect neutyal grounding method in urban MV network. 展开更多
关键词 URBAN medium voltage NETWORK OPTIMIZATION operation characteristic small CURRENT GROUNDING SYSTEM large CURRENT GROUNDING SYSTEM
下载PDF
Study on the Reversible DC-DC Converter as Interface between Low and Medium Voltage DC Networks
11
作者 Stephan Kenzelmann Carlo Arrioja Alfred Rufer 《Journal of Energy and Power Engineering》 2012年第8期1284-1291,共8页
This paper introduces an isolated reversible DC-DC converter with a particular topology, which benefits from both the NPC (neutral point clamped) structure and the series-parallel connection of converters. The key p... This paper introduces an isolated reversible DC-DC converter with a particular topology, which benefits from both the NPC (neutral point clamped) structure and the series-parallel connection of converters. The key property of the proposed topology is the output voltage elevation above the blocking capabilities of each switch, without taking to a delicate synchronization of series-connected semiconductors. The converter is composed by two identical cells, each containing a full bridge, a medium frequency transformer and an NPC converter, connected in parallel at the input and in series at the output. The operation principle of each cell, into which a trapezoidal modulation was implemented, is similar to a DAB (dual active bridge). A new model improves the dynamic performance of the controller. Simulation and experimental results verify the proposed topology, its control and start-up strategy. 展开更多
关键词 DC-DC converter multilevel converter DC transformer medium voltage medium frequency transformer.
下载PDF
Study on 10 kVDC Powered Junction Box for A Cabled Ocean Observatory System 被引量:10
12
作者 陈燕虎 杨灿军 +2 位作者 李德骏 金波 陈鹰 《China Ocean Engineering》 SCIE EI CSCD 2013年第2期265-275,共11页
A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments is developed. A 10 kV direct current (kVDC) with up to 10 kW power, along with l Gigabit/s... A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments is developed. A 10 kV direct current (kVDC) with up to 10 kW power, along with l Gigabit/sec Ethemet communication, can be transmitted from the shore to the seafloor through an umbilical armored cable. A subsea junction box is fixed at a cable terminal, enabling the extension of up to nine connections. The box consists of three main pressure vessels that perform power conversion, power distribution, and real-time communication functions. A method of stacking modules is used to design the power conversion system in order to reduce the 10 kV voltage to levels that can power the attached instruments. A power distribution system and an Ethemet communication system are introduced to control the power supply and transmit data or commands between the terminals and the shore station, respectively. Specific validations of all sections were qualified in a laboratory environment prior to the sea trial. The ocean observatory system was then deployed at the coast of the East China Sea along with three in situ instruments for a 14-day test. The results show that this high voltage-powered observatory system is effective for subsea long-term and real-time observations. 展开更多
关键词 cabled ocean observatory high voltage REAL-TIME power delivery heat dissipation
下载PDF
Scheme of long distance power supply for electrified railway traction network based on traction cable 被引量:2
13
作者 Hui Wang Qunzhan Li +2 位作者 Wei Liu Chuang Wang Tongtong Liu 《Railway Sciences》 2022年第1期114-130,共17页
Purpose–The traction cable is paralleled with the existing traction network of electrified railway through transverse connecting line to form the scheme of long distance power supply for the traction network.This pap... Purpose–The traction cable is paralleled with the existing traction network of electrified railway through transverse connecting line to form the scheme of long distance power supply for the traction network.This paper aims to study the scheme composition and power supply distance(PSD)of the scheme.Design/methodology/approach–Based on the structure of parallel traction network(referred to as“cable traction network(CTN)”),the power supply modes(PSMs)are divided into cableþdirect PSM and cableþautotransformer(AT)PSM(including Japanese mode,French mode and new mode).Taking cableþJapanese AT PSM as an example,the scheme of long distance power supply for CTN under the PSMs of co-phase and out-of-phase power supply are designed.On the basis of establishing the equivalent circuit model and the chain circuit model of CTN,taking the train working voltage as the constraint condition,and based on the power flow calculation of multiple train loads,the calculation formula and process for determining the PSD of CTN are given.The impedance and PSD of CTN under the cableþAT PSM are simulated and analyzed,and a certain line is taken as an example to compare the scheme design.Findings–Results show that the equivalent impedance of CTN under the cableþAT PSM is smaller,and the PSD is about 2.5 times of that under the AT PSM,which can effectively increase the PSD and the flexibility of external power supply location.Originality/value–The research content can effectively improve the PSD of traction power supply system and has important reference value for the engineering application of the scheme. 展开更多
关键词 Traction cable Electrified railway Traction network Long distance power supply voltage drop Power flow calculation
下载PDF
Transformation optics for efficient calculation of transmembrane voltage induced on cells
14
作者 廖胤鸿 朱铧丞 +1 位作者 唐正明 黄卡玛 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期31-35,共5页
We present a novel efficient approach in calculating induced transmembrane voltage(ITV) on cells based on transformation optics. As cell membrane is much thinner than the dimension of a typical cell, discretizing th... We present a novel efficient approach in calculating induced transmembrane voltage(ITV) on cells based on transformation optics. As cell membrane is much thinner than the dimension of a typical cell, discretizing the membrane needs numerous meshes. Using an anisotropic medium based on transformation optics, the thickness of the membrane can be exaggerated by at least one order, which eliminates rigorous mesh refinement and reduces unknowns greatly. The accuracy and efficiency of the proposed method are verified by a cylindrical cell model. Moreover, the influence on ITV with bound water(BW) layers is also studied. The results show that when cells are exposed to nanosecond electric field, BW layers should be rigorously considered in calculating ITV. 展开更多
关键词 efficient calculation transmembrane voltage transformation optics anisotropic medium mem- brane bound water layer
下载PDF
The Stochastic Stability of a Viscoelastic Cable with Small Sag
15
作者 李映辉 彭荣强 高庆 《Journal of Modern Transportation》 2001年第1期59-66,共8页
In this paper, the almost sure stability of a viscoelastic cable subjected to an initial stress on the uniform cross section is studied. The constitutive of the cable material is assumed to be the hereditary integral ... In this paper, the almost sure stability of a viscoelastic cable subjected to an initial stress on the uniform cross section is studied. The constitutive of the cable material is assumed to be the hereditary integral type, the relaxation kernels of which are represented by the sums of exponents. The initial stress and the damping coefficientto the environment and also relaxation kernel coefficients are a random wide band stationary process. The partial differential integral equation of motion is derived first. Then by applying Galerkins method, the governing equation is reduced to a set of second order differential integral equations. Based on the Liapunovs direct method, sufficient conditions for almost sure stability of viscoelstic cable are obtained. 展开更多
关键词 stochastic stability viscoelastic medium mechanics cables
下载PDF
Influence of Negative Bias Voltage on the Mechanical and Tribological Properties of MoS_2/Zr Composite Films 被引量:1
16
作者 宋文龙 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2011年第3期412-416,共5页
MoS2/Zr composite films were deposited on the cemented carbide YT14 (WC+14%TiC+6%Co) by medium-frequency magnetron sputtered and coupled with multi-arc ion plated techniques.The influence of negative bias voltage ... MoS2/Zr composite films were deposited on the cemented carbide YT14 (WC+14%TiC+6%Co) by medium-frequency magnetron sputtered and coupled with multi-arc ion plated techniques.The influence of negative bias voltage on the composite film properties,including adhesion strength,micro-hardness,thickness and tribological properties were investigated.The results showed that proper negative bias voltage could significantly improve the mechanical and tribological properties of composite films.The effects of negative bias voltage on film properties were also put forward.The optimal negative bias voltage was -200 V under this experiment conditions.The obtained composite films were dense,the adhesion strength was about 60 N,the thickness was about 2.4 μm,and the micro-hardness was about 9.0 GPa.The friction coefficient and wear rate was 0.12 and 2.1×10-7 cm3/N·m respectively after 60 m sliding operation against hardened steel under a load of 20 N and a sliding speed of 200 rev·min-1. 展开更多
关键词 medium-frequency magnetron sputtering multi-arc ion plating negative bias voltage MoS2/Zr composite films tribological properties
下载PDF
基于CNN-BiLSTM-Transformer的舰船中压直流全电推进系统故障诊断设计
17
作者 张建良 韩涛 季瑞松 《实验技术与管理》 北大核心 2025年第1期11-18,共8页
针对舰船中压直流全电推进系统结构复杂度高、单元耦合性强、运行环境多变等特点造成的故障诊断准确性低和实时性差等问题,开展了基于CNN-BiLSTM-Transformer的故障诊断设计。首先,基于卷积神经网络CNN构建单点特征级联网络,开展单一时... 针对舰船中压直流全电推进系统结构复杂度高、单元耦合性强、运行环境多变等特点造成的故障诊断准确性低和实时性差等问题,开展了基于CNN-BiLSTM-Transformer的故障诊断设计。首先,基于卷积神经网络CNN构建单点特征级联网络,开展单一时刻下故障信号空间特征的深入提取,以提升故障特征提取的有效性;其次,以双向长短期记忆网络BiLSTM为核心设计多点特征依赖网络,利用门控机制和双向时序学习机制,实现故障信号在多个时刻之间特征依赖关系的有效学习,以提升故障诊断的准确性;然后,以Transformer为核心建立序列特征并行处理网络,通过自注意力机制实现对故障特征上下文关系的精确刻画,进而利用多头注意力机制实现特征序列的并行处理,以提升故障诊断的实时性;最后,设计舰船中压直流全电推进系统故障诊断实验方案,并开展不同故障模式下的诊断性能评估。该文方法在多种故障模式下诊断准确率和实时性均优于现有的主流故障诊断方法,有助于为舰船中压直流全电推进系统的安全运行提供更有力的技术保障。 展开更多
关键词 舰船 中压直流 全电推进系统 故障诊断 TRANSFORMER
下载PDF
基于特征气体的高压电缆缓冲层烧蚀缺陷检测
18
作者 李森林 陈舒昱 +4 位作者 陈奕凯 牛雷 操张鹏 戚梦辉 任成燕 《电工电能新技术》 北大核心 2025年第1期108-117,共10页
近年来,因为高压电缆缓冲层烧蚀导致的电缆运行故障严重危害到电缆系统的安全运行。高压电缆缓冲层材料在烧蚀过程中会产生特征气体,可以基于特征气体检测法实现对缓冲层烧蚀缺陷的预警和诊断。本文搭建了电缆缓冲层放电烧蚀模拟和气体... 近年来,因为高压电缆缓冲层烧蚀导致的电缆运行故障严重危害到电缆系统的安全运行。高压电缆缓冲层材料在烧蚀过程中会产生特征气体,可以基于特征气体检测法实现对缓冲层烧蚀缺陷的预警和诊断。本文搭建了电缆缓冲层放电烧蚀模拟和气体收集实验平台,用不同电极结构模型模拟缓冲层不同缺陷状态,采用气相色谱仪对烧蚀过程中缓冲层的气体进行组分分析,研究产物浓度的演变规律。结果表明缓冲层烧蚀过程中的气体产物包括CO_(2)、H_(2)、CO、低分子量烃类气体等共9种,且各组分气体浓度与缓冲层缺陷类型、烧蚀时间、接触状态等因素直接关联。基于特征气体检测的方法有望应用于高压电缆缓冲层等低场强区潜伏性缺陷的诊断。 展开更多
关键词 高压XLPE电缆 缓冲层烧蚀 气体检测 局部放电
下载PDF
中压发电车多方式应用实验
19
作者 张雷 刘栋 +2 位作者 韩晓昆 姚雁南 申海涛 《农村电气化》 2025年第1期77-81,共5页
随着社会对供电可靠性的要求不断提高,供电保障任务越来越多,中压发电车在自然灾害、10 kV配网设施故障、过载削峰、综合不停电作业等多场景应用发挥着不可替代的作用。为验证多台中压发电车不同组合方式下带负载的可行性及适用场景,开... 随着社会对供电可靠性的要求不断提高,供电保障任务越来越多,中压发电车在自然灾害、10 kV配网设施故障、过载削峰、综合不停电作业等多场景应用发挥着不可替代的作用。为验证多台中压发电车不同组合方式下带负载的可行性及适用场景,开展中压发电车多方式应用实验,共完成单机孤岛、单机正向同期并网、单机正反向同期并网、多机并机孤岛、多机正向同期并网5种典型组合方式的带负载运行,实验结果表明多台中压发电车不同组合方式下带负载是可行的,为现实应用提供了有效参考。 展开更多
关键词 中压发电车 并网 并机
下载PDF
混联线路上不对称操作引起的电压互感器铁磁谐振仿真分析
20
作者 陈浩宇 淡淑恒 +1 位作者 丁文涛 朱小贤 《高压电器》 北大核心 2025年第1期121-128,共8页
城市的配电网中电缆占比越来越大,与传统的架空线组成特殊的架空线—电缆混联线路,导致系统的对地电容发生变化,极易与系统中重要的测量保护元件电压互感器的非线性电感相匹配,从而引起系统中的铁磁谐振,轻则电压互感器熔断器烧坏,重则... 城市的配电网中电缆占比越来越大,与传统的架空线组成特殊的架空线—电缆混联线路,导致系统的对地电容发生变化,极易与系统中重要的测量保护元件电压互感器的非线性电感相匹配,从而引起系统中的铁磁谐振,轻则电压互感器熔断器烧坏,重则电压互感器发生爆炸,严重威胁到操作员的安全。基于PSCAD建立由架空线—电缆组成的10 kV混联线路仿真模型,选用可以模拟饱和特性的UMEC模型搭建电磁式电压互感器,并对其设置不同的饱和点电压。观测在线路上不对称合闸操作产生的高频暂态电压的激发下,电压互感器出现的铁磁谐振现象,并分析不同饱和特性下电压互感器一次侧电流的总谐波畸变率(THD)。通过以上分析研究为电磁式电压互感器在系统中的正确选用及安全可靠运行提供理论依据,为避免10 kV电磁式电压互感器的损坏提供了技术支持。 展开更多
关键词 架空线—电缆混联线路 电压互感器 不对称操作 铁磁谐振 谐波畸变率
下载PDF
上一页 1 2 172 下一页 到第
使用帮助 返回顶部