期刊文献+
共找到3,388篇文章
< 1 2 170 >
每页显示 20 50 100
Nonlinear Response Analysis for Insulation Diagnosis of Water-tree Aged 10 kV XLPE Cable Using Pulse Voltage 被引量:3
1
作者 DU Boxue WANG Li 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1852-1857,共6页
The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged ... The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged 10 kV XLPE cables were diagnosed. The cables were subjected to electrical stress of 5.9 kV/mm and a thermal load cycle in a curved water-filled tube for 3, 6 and 12 months of aging in accor- dance with the accelerated water-tree test method. The aged cables were used as the samples for water-tree diagnosis. First, the water-tree degraded cable, was charged by a DC voltage, and then the cable was grounded while a pulse voltage was applied to it for releasing the space charge trapped in the water trees. The amount of the space charge, which corresponds to the deterioration degree of the water trees, was calculated. The effects of DC voltage amplitude, pulse voltage repetition rate and aging conditions on the amount of the space charge were studied. Obtained results show that the amount of the space charge has a positive correlation with the applied DC voltage and the ag- ing time of the cables, and that a peak value of space charge appears with the increase of the pulse voltage repetition rate. An optimum pulse voltage repetition rate under which the space charge can be released rapidly is obtained. Furthermore, the releasing mechanism of space charge by the pulse voltage is discussed. Accumulated results show that the presented method has a high resolution for the diagnosis of water tree degradation degree and is expected to be applied in practice in future. 展开更多
关键词 交联聚乙烯电缆 脉冲电压 绝缘诊断 非线性响应 水树 交联聚乙烯绝缘电缆 空间电荷 电缆老化
下载PDF
Aspects of High Voltage Cable Sections in Modern Overhead Line Transmission Systems
2
作者 T. Judendorfer S. Pack M. Muhr 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2732-2738,共7页
Electrical power transmission is dominated by overhead line systems at present.This is mainly based on more than hundred years of experience of utilities in running overhead lines.Furthermore,overhead lines have prove... Electrical power transmission is dominated by overhead line systems at present.This is mainly based on more than hundred years of experience of utilities in running overhead lines.Furthermore,overhead lines have proven their operational reliability and functional assurance.In the past,cables were used in distribution networks in urban areas for the most part with the exception of direct current submarine cables.New developments of high voltage XLPE cables make it possible to use this technology for EHV level applications in transmission networks.Within this paper,mixed network configurations,consisting of overhead lines and high voltage cables,are investigated.An exemplary EHV transmission line with a total length of about 100 km,which is quite typical for Central Europe,has been studied.Several different line combinations are discussed with varied rates between overhead line sections and cable sections length in practice.The length of the cable sections are ranging from several kilometers up to lengths of 100 km.In this paper the work focuses on the transient behavior of combined 400 kV overhead and cable lines during switching processes and lightning impacts.A number of calculations were carried out to get an overview of the transient stress in numerous network nodes along the transmission system.Numerical programs like ATP/EMTP have been used for these simulations.Peak values and wave shapes of the transient voltage stress have been evaluated,based on different systems and within possible combinations.In respect of the insulation coordination and transient stress at network nodes,the voltage-time trends are also analyzed.The combination of high voltage overhead and cable transmission systems,especially such with lengths of more than about 50 km,are making tightened and extended demands to the network design,to the operational management and of course to the network protection also.As an output of this investigations,the results might influence the strategy in running this new type of combined transmission systems. 展开更多
关键词 架空线路 输电系统 高压电缆 配电 绝缘体 混合系统
下载PDF
Statistical Characteristics of Partial Discharge Caused by Typical Defects in Cable Joint under Oscillating Voltage
3
作者 Guangmao Li Zuwei Luo +2 位作者 Jun Xiong Zucheng Huang Yajun Wang 《Journal of Energy and Power Engineering》 2015年第3期310-316,共7页
The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artifi... The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artificial defect models of cable joints in 10 kV XLPE cable. Oscillating voltage is applied to the model, by use of pulse current method to detect partial discharge signals. In order to study the statistical characteristics of partial discharge of cable joint under the oscillating voltage, three-dimensional statistical map has been made. The results show that for the same kind of defects, with the increases of the defect severity, the discharge interval extended, the magnitude and the number of partial discharge increase, for different kinds of defects, obvious differences exist among the maps, this may established a foundation for the further study of the partial discharge pattern recognition of XLPE cable under oscillating voltage. 展开更多
关键词 XLPE cable cable joint defect model partial discharge oscillating voltage three-dimensional statistical map.
下载PDF
The Use of Life Cycle Cost Analysis to Determine the Most Effective Cost of Installation High Voltage Undersea Cable Bali Strait
4
作者 Ngapuli Sinisuka lqbal Felani Novrizal Erdiansyah 《Journal of Energy and Power Engineering》 2012年第12期2082-2089,共8页
Indonesian National Electricity Company (PT.PLN (Persero)) has planned to install additional high voltage undersea cable for circuit llI and IV Java-Bali to fulfill electricity demand in Bali. This project was mor... Indonesian National Electricity Company (PT.PLN (Persero)) has planned to install additional high voltage undersea cable for circuit llI and IV Java-Bali to fulfill electricity demand in Bali. This project was more prefered compared to building another power plant in Bali which could raise social and cultural resistance. Life cycle cost method was used to complete the financial feasibility study to ensure if the project has economic benefit, and the asset would be used effectively and efficiently along its benefit period. In this paper, a life cycle cost will be simulated to analyze which alternative is the most profitable: installation circuit III and IV in 2012 or installation circuit III in 2012 and circuit IV in 2017 in accordance with load forecasting demand. This study is used to help the management to make a decision about the project. 展开更多
关键词 Financial feasibility life cycle cost high voltage undersea cable installation.
下载PDF
Performance Evaluation for Medium Voltage MIMO-OFDM Power Line Communication System 被引量:10
5
作者 Yingxue Li Min Zhang +3 位作者 Wenguang Zhu Mengyuan Cheng Cheng Zhou Yongpeng Wu 《China Communications》 SCIE CSCD 2020年第1期151-162,共12页
Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)s... Power line communication(PLC)provides intelligent electrical functions such as power quality measurement,fault surveys,and remote control of electrical network.Most of research works have been done in low voltage(LV)scenario due to the fast development of in-home PLC.The aim of this paper is to evaluate the link-level performance of a medium voltage(MV)MIMO-OFDM communication system based on transmission link under underground power line channel.The MIMO channel is modeled as a modified multipath model in the presence of impulsive noise and background noise.We first perform a measurement on the practical MV MIMO channel parameters for a section of buried cable of 1 km long in Ganzhou city,Jiangxi province,China.Based on the measured channel,we design the frame structure based on an IEEE standard for broadband over power line networks[1]to support MV MIMO-OFDM transmission.According to designed frame structure,we design an encoder and a decoder for a dual binary tail-biting turbo code and optimize some key decoder parameters for low bit error rate performance.Finally,the link-level performance for both spatial multiplexing and spatial diversity are evaluated.Numeral results show that MV MIMO-OFDM is a promising approach to provide both high data rate and link reliability for PLC. 展开更多
关键词 power line communication(PLC) MIMO-OFDM multi-conductor medium voltage underground cables turbo code
下载PDF
Key technologies for medium and low voltage DC distribution system 被引量:6
6
作者 Yiwen Fan Yongning Chi +4 位作者 Yan Li Zhibing Wang Hongzhi Liu Wei Liu Xiangyu Li 《Global Energy Interconnection》 CAS CSCD 2021年第1期91-103,共13页
Development of the medium and low voltage DC distribution system is of great significance to a regional transmission of electric energy,increasing a penetration rate of new energy,and enhancing a safety of the operati... Development of the medium and low voltage DC distribution system is of great significance to a regional transmission of electric energy,increasing a penetration rate of new energy,and enhancing a safety of the operation of the AC/DC interconnected grid.This paper first summarizes the medium and low voltage DC distribution system schemes and plans put forward by many countries,and then elaborate status of under-construction medium and low voltage DC distribution system project cases in China.Based on these project cases,this paper analyzes key issues involved in the medium and low voltage DC distribution system topologies,equipment,operation control technologies and DC fault protections,in order to provide theoretical and technical reference for future medium and low voltage DC distribution system-related projects.Finally,this paper combines a current China research status to summarize and give a prediction about the future research direction of medium and low voltage DC distribution system,which can provide reference for the research of medium and low voltage DC distribution system. 展开更多
关键词 medium and low voltage DC distribution system System topology Key equipment DC fault protection Operation control technology
下载PDF
A Novel Serial Hybrid Three-level NPC Topology for Multi-MW Medium Voltage Wind Power Converters 被引量:5
7
作者 CHEN Gen WANG Yong CAI Xu 《中国电机工程学报》 EI CSCD 北大核心 2013年第9期I0007-I0007,共1页
提出一种新型的串联混合三电平中点钳位(neutralpoint clamped,NPC)拓扑,该拓扑是基于传统三电平NPC拓扑的改进和优化,引入大功率IGBT的串联应用。该新型拓扑中,桥臂的两个外管分别用两个低压IGBT串联,两个内管均用高压IGBT。在多兆... 提出一种新型的串联混合三电平中点钳位(neutralpoint clamped,NPC)拓扑,该拓扑是基于传统三电平NPC拓扑的改进和优化,引入大功率IGBT的串联应用。该新型拓扑中,桥臂的两个外管分别用两个低压IGBT串联,两个内管均用高压IGBT。在多兆瓦级中压风电变流器中,大功率IGBT的开关损耗很大,从而限制了开关频率。提出的新型拓扑通过低压IGBT的串联来减小功率器件的损耗,从而提高开关频率,同时可减小输出滤波器的尺寸。通过传统三电平拓扑和新型串联混合三电平拓扑IGBT损耗的对比,说明新拓扑的优势。通过改变门极驱动电阻实现串联IGBT的均压,对新拓扑的应用具有重大意义。最后通过新拓扑的单相样机验证新拓扑的正确性和可行性。 展开更多
关键词 电压转换器 拓扑结构 风力发电 中压 NPC 三电平 混合 串联
下载PDF
Development of a Medium Voltage, High Power, High Frequency Four-Port Solid State Transformer 被引量:1
8
作者 Ahmad El Shafei Saban Ozdemir +2 位作者 Necmi Altin Garry Jean-Pierre Adel Nasiri 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第1期95-104,共10页
The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies.For that,the need for the development of a compact and highly efficie... The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies.For that,the need for the development of a compact and highly efficient solid-state transformer is becoming a critical task in-order to integrate the current AC grid with the new renewable energy systems.The objective of this paper is to present the design,implementation,and testing of a compact multi-port solid-state transformer for microgrid integration applications.The proposed system has a four-port transformer and four converters connected to the ports.The transformer has four windings integrated on a single common core.Thus,it can integrate different renewable energy resources and energy storage systems.Each port has a rated power of 25 kW,and the switching frequency is pushed to 50 k Hz.The ports are chosen to represent a realistic industrial microgrid model consisting of grid,energy storage system,photovoltaic system,and load.The grid port is designed to operate at 4.16 k VAC corresponding to 7.2 kV DC bus voltage,while the other three ports operate at 500 VDC.Moreover,the grid,energy storage and photovoltaic ports are active ports with dual active bridge topologies,while the load port is a passive port with full bridge rectifier one.The proposed design is first validated with simulation results,and then the proposed transformer is implemented and tested.Experimental results show that the designed system is suitable for 4.16 k VAC medium voltage grid integration. 展开更多
关键词 CO-SIMULATION high frequency high power medium voltage MICROGRID MULTI-PORT solid state transformer
下载PDF
Multilevel Current Source Converters for High Power Medium Voltage Applications 被引量:1
9
作者 Li Ding Yujuan Lian Yun Wei Li 《CES Transactions on Electrical Machines and Systems》 2017年第3期306-314,共9页
In medium voltage high power applications,multi-level current source converters(CSCs)are good candidate to increase system power region,reliability,and the quality of output waveforms.Compared with widely researched v... In medium voltage high power applications,multi-level current source converters(CSCs)are good candidate to increase system power region,reliability,and the quality of output waveforms.Compared with widely researched voltage source multi-level converters(MLCs),the current source MLCs have the advantages of inherent short-circuit protection,high power capability and high quality of output current waveforms.The main features of MLCs include reduced harmonics,lower switching frequency and reduced current stress on each device which is a particularly important for high power application with low voltage and high current requirements.This paper conducts a general review of the current research about MLCs in higher power medium voltage application.The different types of parallel structure based MLCs and the modulation methodologies will be introduced and compared.Specifically,the circuit analysis of the common-mode(CM)loop for parallel structures will be conducted,the common-mode voltage(CMV)and circulating current suppression methods developed on the base of multilevel modulations will be addressed. 展开更多
关键词 Circulating current common-mode voltage current source converters multi-level converter high power medium voltage parallel structure
下载PDF
The Optimization on Operation Characteristicsof Urban Medium Voltage Network
10
作者 Yao Huannian Cao Meiyue(Xiamen Electric Power Administration, Xiamen) 《Electricity》 1998年第3期27-29,共3页
Traditional small current grounding system has many advantages. Pilot operation shows that optimized one has even better operation characteristics. It has proven to be a geenrallly properand relatively perfect neutyal... Traditional small current grounding system has many advantages. Pilot operation shows that optimized one has even better operation characteristics. It has proven to be a geenrallly properand relatively perfect neutyal grounding method in urban MV network. 展开更多
关键词 URBAN medium voltage NETWORK OPTIMIZATION operation characteristic small CURRENT GROUNDING SYSTEM large CURRENT GROUNDING SYSTEM
下载PDF
Study on the Reversible DC-DC Converter as Interface between Low and Medium Voltage DC Networks
11
作者 Stephan Kenzelmann Carlo Arrioja Alfred Rufer 《Journal of Energy and Power Engineering》 2012年第8期1284-1291,共8页
This paper introduces an isolated reversible DC-DC converter with a particular topology, which benefits from both the NPC (neutral point clamped) structure and the series-parallel connection of converters. The key p... This paper introduces an isolated reversible DC-DC converter with a particular topology, which benefits from both the NPC (neutral point clamped) structure and the series-parallel connection of converters. The key property of the proposed topology is the output voltage elevation above the blocking capabilities of each switch, without taking to a delicate synchronization of series-connected semiconductors. The converter is composed by two identical cells, each containing a full bridge, a medium frequency transformer and an NPC converter, connected in parallel at the input and in series at the output. The operation principle of each cell, into which a trapezoidal modulation was implemented, is similar to a DAB (dual active bridge). A new model improves the dynamic performance of the controller. Simulation and experimental results verify the proposed topology, its control and start-up strategy. 展开更多
关键词 DC-DC converter multilevel converter DC transformer medium voltage medium frequency transformer.
下载PDF
Study on 10 kVDC Powered Junction Box for A Cabled Ocean Observatory System 被引量:10
12
作者 陈燕虎 杨灿军 +2 位作者 李德骏 金波 陈鹰 《China Ocean Engineering》 SCIE EI CSCD 2013年第2期265-275,共11页
A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments is developed. A 10 kV direct current (kVDC) with up to 10 kW power, along with l Gigabit/s... A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments is developed. A 10 kV direct current (kVDC) with up to 10 kW power, along with l Gigabit/sec Ethemet communication, can be transmitted from the shore to the seafloor through an umbilical armored cable. A subsea junction box is fixed at a cable terminal, enabling the extension of up to nine connections. The box consists of three main pressure vessels that perform power conversion, power distribution, and real-time communication functions. A method of stacking modules is used to design the power conversion system in order to reduce the 10 kV voltage to levels that can power the attached instruments. A power distribution system and an Ethemet communication system are introduced to control the power supply and transmit data or commands between the terminals and the shore station, respectively. Specific validations of all sections were qualified in a laboratory environment prior to the sea trial. The ocean observatory system was then deployed at the coast of the East China Sea along with three in situ instruments for a 14-day test. The results show that this high voltage-powered observatory system is effective for subsea long-term and real-time observations. 展开更多
关键词 cabled ocean observatory high voltage REAL-TIME power delivery heat dissipation
下载PDF
Scheme of long distance power supply for electrified railway traction network based on traction cable 被引量:2
13
作者 Hui Wang Qunzhan Li +2 位作者 Wei Liu Chuang Wang Tongtong Liu 《Railway Sciences》 2022年第1期114-130,共17页
Purpose–The traction cable is paralleled with the existing traction network of electrified railway through transverse connecting line to form the scheme of long distance power supply for the traction network.This pap... Purpose–The traction cable is paralleled with the existing traction network of electrified railway through transverse connecting line to form the scheme of long distance power supply for the traction network.This paper aims to study the scheme composition and power supply distance(PSD)of the scheme.Design/methodology/approach–Based on the structure of parallel traction network(referred to as“cable traction network(CTN)”),the power supply modes(PSMs)are divided into cableþdirect PSM and cableþautotransformer(AT)PSM(including Japanese mode,French mode and new mode).Taking cableþJapanese AT PSM as an example,the scheme of long distance power supply for CTN under the PSMs of co-phase and out-of-phase power supply are designed.On the basis of establishing the equivalent circuit model and the chain circuit model of CTN,taking the train working voltage as the constraint condition,and based on the power flow calculation of multiple train loads,the calculation formula and process for determining the PSD of CTN are given.The impedance and PSD of CTN under the cableþAT PSM are simulated and analyzed,and a certain line is taken as an example to compare the scheme design.Findings–Results show that the equivalent impedance of CTN under the cableþAT PSM is smaller,and the PSD is about 2.5 times of that under the AT PSM,which can effectively increase the PSD and the flexibility of external power supply location.Originality/value–The research content can effectively improve the PSD of traction power supply system and has important reference value for the engineering application of the scheme. 展开更多
关键词 Traction cable Electrified railway Traction network Long distance power supply voltage drop Power flow calculation
下载PDF
Transformation optics for efficient calculation of transmembrane voltage induced on cells
14
作者 廖胤鸿 朱铧丞 +1 位作者 唐正明 黄卡玛 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期31-35,共5页
We present a novel efficient approach in calculating induced transmembrane voltage(ITV) on cells based on transformation optics. As cell membrane is much thinner than the dimension of a typical cell, discretizing th... We present a novel efficient approach in calculating induced transmembrane voltage(ITV) on cells based on transformation optics. As cell membrane is much thinner than the dimension of a typical cell, discretizing the membrane needs numerous meshes. Using an anisotropic medium based on transformation optics, the thickness of the membrane can be exaggerated by at least one order, which eliminates rigorous mesh refinement and reduces unknowns greatly. The accuracy and efficiency of the proposed method are verified by a cylindrical cell model. Moreover, the influence on ITV with bound water(BW) layers is also studied. The results show that when cells are exposed to nanosecond electric field, BW layers should be rigorously considered in calculating ITV. 展开更多
关键词 efficient calculation transmembrane voltage transformation optics anisotropic medium mem- brane bound water layer
下载PDF
The Stochastic Stability of a Viscoelastic Cable with Small Sag
15
作者 李映辉 彭荣强 高庆 《Journal of Modern Transportation》 2001年第1期59-66,共8页
In this paper, the almost sure stability of a viscoelastic cable subjected to an initial stress on the uniform cross section is studied. The constitutive of the cable material is assumed to be the hereditary integral ... In this paper, the almost sure stability of a viscoelastic cable subjected to an initial stress on the uniform cross section is studied. The constitutive of the cable material is assumed to be the hereditary integral type, the relaxation kernels of which are represented by the sums of exponents. The initial stress and the damping coefficientto the environment and also relaxation kernel coefficients are a random wide band stationary process. The partial differential integral equation of motion is derived first. Then by applying Galerkins method, the governing equation is reduced to a set of second order differential integral equations. Based on the Liapunovs direct method, sufficient conditions for almost sure stability of viscoelstic cable are obtained. 展开更多
关键词 stochastic stability viscoelastic medium mechanics cables
下载PDF
Influence of Negative Bias Voltage on the Mechanical and Tribological Properties of MoS_2/Zr Composite Films 被引量:1
16
作者 宋文龙 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2011年第3期412-416,共5页
MoS2/Zr composite films were deposited on the cemented carbide YT14 (WC+14%TiC+6%Co) by medium-frequency magnetron sputtered and coupled with multi-arc ion plated techniques.The influence of negative bias voltage ... MoS2/Zr composite films were deposited on the cemented carbide YT14 (WC+14%TiC+6%Co) by medium-frequency magnetron sputtered and coupled with multi-arc ion plated techniques.The influence of negative bias voltage on the composite film properties,including adhesion strength,micro-hardness,thickness and tribological properties were investigated.The results showed that proper negative bias voltage could significantly improve the mechanical and tribological properties of composite films.The effects of negative bias voltage on film properties were also put forward.The optimal negative bias voltage was -200 V under this experiment conditions.The obtained composite films were dense,the adhesion strength was about 60 N,the thickness was about 2.4 μm,and the micro-hardness was about 9.0 GPa.The friction coefficient and wear rate was 0.12 and 2.1×10-7 cm3/N·m respectively after 60 m sliding operation against hardened steel under a load of 20 N and a sliding speed of 200 rev·min-1. 展开更多
关键词 medium-frequency magnetron sputtering multi-arc ion plating negative bias voltage MoS2/Zr composite films tribological properties
下载PDF
改进下垂控制下的中压直流配电系统双时间尺度分层调控方法 被引量:1
17
作者 肖迁 陆文标 +2 位作者 贾宏杰 穆云飞 余晓丹 《中国电机工程学报》 EI CSCD 北大核心 2024年第7期2507-2518,I0001,共13页
针对中压直流配电系统,在负荷激增、可再生能源出力突变等特殊工况下,传统优化调度方案与协调控制策略存在系统运行经济性有待提升、直流母线电压易越限的问题。为此,提出一种基于改进下垂控制的中压直流配电系统双时间尺度分层调控方... 针对中压直流配电系统,在负荷激增、可再生能源出力突变等特殊工况下,传统优化调度方案与协调控制策略存在系统运行经济性有待提升、直流母线电压易越限的问题。为此,提出一种基于改进下垂控制的中压直流配电系统双时间尺度分层调控方法。首先,构建一种具备直流故障穿越能力的3端混合型模块化多电平换流器(modular multilevel converter,MMC)环状±10 kV中压直流配电系统,该系统含电动汽车充电站、储能系统、分布式光伏与风电等灵活性资源。其次,制定各单元协调控制策略,并采用tan函数改进传统下垂控制,以提高系统应对大幅功率波动的能力。然后,基于改进控制策略提出一种双时间尺度分层优化调控方法:在长时间尺度的系统调度层,以运行总成本最小为优化目标,确定各换流器参考功率;在短时间尺度的换流器间协调控制层,改进下垂曲线,并优化控制系数,以兼顾系统运行经济性与电能质量。最后,以典型算例验证该文所提优化调度方案及协调控制策略的有效性:通过灵活调度多种柔性资源,系统运行总成本可降低约11%;在某数据中心负荷激增100%的工况下,各直流母线电压波动仍能维持在±3%UN(额定电压)的允许范围内。 展开更多
关键词 中压直流配电系统 分层协调控制 双时间尺度优化 改进下垂控制 系数优化
下载PDF
高压XLPE电缆缓冲层缺陷研究现状综述 被引量:1
18
作者 邱玮 章宇聪 +4 位作者 谢亿 曹先慧 刘维可 胡俊 李湘珺 《绝缘材料》 CAS 北大核心 2024年第4期13-21,共9页
高压交联聚乙烯电缆因缓冲层缺陷引发的故障频发,已严重威胁到电力系统的安全运行。本文首先介绍了缓冲层的基本结构和作用,并在此基础上梳理了目前国内外对于缓冲层失效的相关研究;其次从缓冲层的材料特征和内部结构等角度结合电场仿... 高压交联聚乙烯电缆因缓冲层缺陷引发的故障频发,已严重威胁到电力系统的安全运行。本文首先介绍了缓冲层的基本结构和作用,并在此基础上梳理了目前国内外对于缓冲层失效的相关研究;其次从缓冲层的材料特征和内部结构等角度结合电场仿真来分析缺陷发生的主要原因;之后对缓冲层缺陷中出现的白色粉末绝缘性能和理化特征进行总结,并提出其形成机理;最后对缓冲层缺陷的检测手段进行汇总,提出使用计算机断层成像技术对电缆缓冲层缺陷进行检测以弥补现有检测手段的不足,并建议对铝护套及缓冲层的材料或结构进行优化,以预防缓冲层缺陷的生成。 展开更多
关键词 高压电缆 交联聚乙烯 缓冲层缺陷 计算机断层成像 平滑铝护套
下载PDF
高比例分布式电源配电网中低压柔性互联协调规划
19
作者 彭寒梅 尹棠 +3 位作者 肖千皓 谭貌 苏永新 李辉 《中国电力》 CSCD 北大核心 2024年第8期117-129,共13页
柔性互联技术是解决高比例分布式电源(distributed generation,DG)配电网面临诸多问题的有效手段之一。提出了一种基于多层优化的配电网中压与低压柔性互联协调规划方法。首先,建立基于电力电子柔性互联设备(flexible interconnected de... 柔性互联技术是解决高比例分布式电源(distributed generation,DG)配电网面临诸多问题的有效手段之一。提出了一种基于多层优化的配电网中压与低压柔性互联协调规划方法。首先,建立基于电力电子柔性互联设备(flexible interconnected devices,FID)的中低压柔性互联配电网潮流模型。然后,构建三层协调规划模型,上层以低压FID年运行成本及台区变压器负载率的年方差最小为目标,中层以中压FID年运行成本及从上级电网年购电成本最小为目标,分别决策低压和中压FID的安装位置与容量,下层以各场景的从上级电网购电成本最小为目标优化系统运行,并采用自适应粒子群优化和二阶锥规划相结合的混合算法求解。最后,采用含高比例DG的IEEE 33节点配电网进行算例分析,通过柔性互联规划系统的年综合运行成本降低了19.01%,台区变压器负载率的年方差减少了82.59%,验证了所提规划模型的有效性。 展开更多
关键词 分布式电源 中低压柔性互联 协调规划 电力电子柔性互联设备 台区变压器负载率
下载PDF
模块化多电平中压直流变换器的高可靠自供电架构研究
20
作者 李楚杉 方恒 +3 位作者 龚青苑 李成敏 李武华 何湘宁 《中国电机工程学报》 EI CSCD 北大核心 2024年第2期670-681,I0020,共13页
随着大容量中压直流配电技术的迅速发展,模块化多电平直流变换器受到工业界和学术界的广泛关注。然而,实现高可靠的辅助供电是实现直流变换器在中压直流配电场景中应用的关键技术瓶颈之一。为此,提出一种面向模块化多电平中压直流变换... 随着大容量中压直流配电技术的迅速发展,模块化多电平直流变换器受到工业界和学术界的广泛关注。然而,实现高可靠的辅助供电是实现直流变换器在中压直流配电场景中应用的关键技术瓶颈之一。为此,提出一种面向模块化多电平中压直流变换器的高可靠自供电系统架构。该架构实现主控制器、子模块等辅电系统的中压直联馈电,从而无需额外低压直流电源,并且大幅提升系统启动速度。基于此架构设计,模块化多电平直流变换器的子模块控制器和旁路开关辅助供电均实现3倍冗余,提高系统容错运行的能力。在子模块电容预充电阶段,提出一种基于辅助电源自主控制的子模块电容均压方法,保证模块化多电平直流变换器可靠预充电。最终通过实验验证所提辅助供电系统架构的可行性。 展开更多
关键词 模块化多电平直流变换器 自供电 中压直联馈电 子模块电容均压
下载PDF
上一页 1 2 170 下一页 到第
使用帮助 返回顶部