A "mega-earthquake" is one with an intensity larger than the most severe earthquake intensity category currently considered in design codes. For a "mega-earthquake," the design objective of a given...A "mega-earthquake" is one with an intensity larger than the most severe earthquake intensity category currently considered in design codes. For a "mega-earthquake," the design objective of a given structure is to "preserve living spaces for people in the buildings." In this paper,factors that may influence the collapse resistance of RC frames in a mega-earthquake are analyzed based on seismic damage observed in the 2008 Wenchuan earthquake. Methodologies to improve structural collapse resistance focus on three aspects:global strength margin,global redundancy and global integration of the structural system. Fundamental principles and design concepts for collapse prevention under a mega-earthquake are proposed,and issues that need further research are identified.展开更多
According to the Code for Seismic Design of Buildings (GB50011-2001), ten typical reinforced concrete (RC) frame structures, used as school classroom buildings, are designed with different seismic fortification in...According to the Code for Seismic Design of Buildings (GB50011-2001), ten typical reinforced concrete (RC) frame structures, used as school classroom buildings, are designed with different seismic fortification intensities (SFIs) (SFI=6 to 8.5) and different seismic design categories (SDCs) (SDC=B and C). The collapse resistance of the frames with SDC=B and C in terms of collapse fragility curves are quantitatively evaluated and compared via incremental dynamic analysis (IDA). The results show that the collapse resistance of structures should be evaluated based on both the absolute seismic resistance and the corresponding design seismic intensity. For the frames with SFI from 6 to 7.5, because they have relatively low absolute seismic resistance, their collapse resistance is insufficient even when their corresponding SDCs are upgraded from B to C. Thus, further measures are needed to enhance these structures, and some suggestions are proposed.展开更多
基金National Natural Science Foundation of China Under Grant No.90815025 The National Key Technologies R&D Program Under Grant No.2009BAJ28B01,2006BAJ03A02-01 for Changjiang Scholars and Innovative Research Team in Universities
文摘A "mega-earthquake" is one with an intensity larger than the most severe earthquake intensity category currently considered in design codes. For a "mega-earthquake," the design objective of a given structure is to "preserve living spaces for people in the buildings." In this paper,factors that may influence the collapse resistance of RC frames in a mega-earthquake are analyzed based on seismic damage observed in the 2008 Wenchuan earthquake. Methodologies to improve structural collapse resistance focus on three aspects:global strength margin,global redundancy and global integration of the structural system. Fundamental principles and design concepts for collapse prevention under a mega-earthquake are proposed,and issues that need further research are identified.
基金National Science Foundation of China Under Grant No.90815025&51178249the National Key Technologies R&D Program Under Grant No.2009BAJ28B01&2006BAJ03A02-01+1 种基金Tsinghua University Research Funds No.2010THZ02-1the Program for New Century Excellent Talents in University
文摘According to the Code for Seismic Design of Buildings (GB50011-2001), ten typical reinforced concrete (RC) frame structures, used as school classroom buildings, are designed with different seismic fortification intensities (SFIs) (SFI=6 to 8.5) and different seismic design categories (SDCs) (SDC=B and C). The collapse resistance of the frames with SDC=B and C in terms of collapse fragility curves are quantitatively evaluated and compared via incremental dynamic analysis (IDA). The results show that the collapse resistance of structures should be evaluated based on both the absolute seismic resistance and the corresponding design seismic intensity. For the frames with SFI from 6 to 7.5, because they have relatively low absolute seismic resistance, their collapse resistance is insufficient even when their corresponding SDCs are upgraded from B to C. Thus, further measures are needed to enhance these structures, and some suggestions are proposed.