期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Melanin nanoparticles alleviate sepsis-induced myocardial injury by suppressing ferroptosis and inflammation 被引量:5
1
作者 Chang Liu Quan Zou +11 位作者 Huixin Tang Jia Liu Shiqi Zhang Caihong Fan Junwei Zhang Ruiqing Liu Yashan Liu Ruiyan Liu Yan Zhao Qiang Wu Zhi Qi Yanna Shen 《Bioactive Materials》 SCIE CSCD 2023年第6期313-321,共9页
Myocardial injury as one of the severe complications leads to the increasing morbidity and mortality in patients with sepsis.Recent studies reported that reactive oxygen species(ROS)-mediated ferroptosis plays a criti... Myocardial injury as one of the severe complications leads to the increasing morbidity and mortality in patients with sepsis.Recent studies reported that reactive oxygen species(ROS)-mediated ferroptosis plays a critical role in the development of heart diseases.Therefore,we hypothesized that anti-ferroptosis agent might be a novel potential therapeutic strategy for sepsis-induced cardiac injury.Herein,we demonstrated that a small biocompatible and MRI-visible melanin nanoparticles(MMPP)improves myocardial function by inhibiting ROS-related ferroptosis signaling pathway.In LPS-induced murine sepsis model,after a single dose intravenously injection of MMPP treatment,MMPP markedly alleviated the myocardial injury including cardiac function and heart structure disorder through suppressing iron-accumulation induced ferroptosis.In vitro,MMPP inhibited cardiomyocyte death by attenuating oxidative stress,inflammation and maintaining mitochondrial homeostasis.Collectively,our findings demonstrated that MMPP protected heart against sepsis-induced myocardial injury via inhibiting ferroptosis and inflammation,which might be a novel therapeutic approach in future. 展开更多
关键词 SEPSIS Myocardial injury melanin nanoparticles Ferroptosis INFLAMMATION
原文传递
pH Readout enhanced ELISA for point-of-care testing of cardiac troponin I
2
作者 Luyang Miao Lianhua Zhang +3 位作者 Lei Jiao Xiaofeng Tan Qin Wei He Li 《Chinese Chemical Letters》 SCIE CAS CSCD 2017年第9期1878-1880,共3页
Enzyme-linked immunosorbent assay(ELISA) as a conventional method for protein quantification has its characteristic properties,however,it is challenging to implement excellent portability and sensitivity at the same... Enzyme-linked immunosorbent assay(ELISA) as a conventional method for protein quantification has its characteristic properties,however,it is challenging to implement excellent portability and sensitivity at the same time.In this study,we described a pH ELISA using synthetic melanin nanoparticles(SMNPs) for the co-immobilization of glucose oxidase(GOx) and second antibody(Ab_2) as signal labels,portable pH meter as signal readout device for point-of-care testing(POCT) of cardiac troponin I(cTnI).In accordance with the varying amount of cTnI,following sandwich type immunoassay,proportional SMNPs-GOx-Ab_2 were immobilized specifically resulting in corresponding decrease of pH values owing to GOx loaded on SMNPs can high-efficiency convert glucose into gluconic acid.This assay is easy-to-use,portable,sensitive and able to realize POCT,affording a linear range from 0.5 pg/m L to 10 ng/m L and low limit of detection(LOD) of 0.15 pg/m L towards cTnI,which was demonstrated the significant promising in the early diagnosis and screening of acute myocardial infarction. 展开更多
关键词 pH meter Synthetic melanin nanoparticles Polydopamine nanospheres Biomarker Immunosensor
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部