The orthogonal experiments, which involves three factors: aeration intensity, suction time and suction suspended time, were designed to research membrane fouling of jet loop membrane bioreactor (JLMBR). Experimenta...The orthogonal experiments, which involves three factors: aeration intensity, suction time and suction suspended time, were designed to research membrane fouling of jet loop membrane bioreactor (JLMBR). Experimental results indicate that increasing aeration intensity, reducing suction time and increasing suction suspended time all could mitigate membrane fouling effectively. However excessive aeration intensity, too short suction time and excessive suction suspended time were bad for bioreactor running. The optimal aeration intensity, suction time and suction suspended time were 0.75 1.00 m3/(m2.h), 8 -10 min and 4 -5 min, respectively. The three factors all had effect on membrane pollution rate, while the suction time was the most important one and followed by aeration intensity and suction suspended time. It also indicates that, comparing with traditional submerged membrane bioreactors, JLMBR had lower membrane pollution rate.展开更多
在设定的膜内压力下(2 k Pa)启动并运行膜曝气生物膜反应器(MABR),对生物膜生长过程中的硝化性能及生物膜组成变化进行了分析。实验结果表明,在生物膜厚度增长到(293.3±5.8)μm的过程中,生物膜内的总氧通量先增加后减少,最高可达21...在设定的膜内压力下(2 k Pa)启动并运行膜曝气生物膜反应器(MABR),对生物膜生长过程中的硝化性能及生物膜组成变化进行了分析。实验结果表明,在生物膜厚度增长到(293.3±5.8)μm的过程中,生物膜内的总氧通量先增加后减少,最高可达21.3 g O2?m?2?d?1,证实了生物膜的存在可增强MABR的氧传质能力。在生物膜厚度增长的过程中,氨氮表面去除负荷也是先增加后减少,最高可达4.91 g N?m?2?d?1,表明在MABR硝化过程中存在最佳的生物膜厚度,根据所研究最佳生物膜厚度为(119.0±3.0)μm,此时MABR具有最高的氧通量和氨氮表面去除负荷,硝化性能最好。生物膜内胞外聚合物(EPS)成分分析结果表明,随着生物膜厚度的增加,生物膜内层紧密型EPS的含量增加,导致氧传质阻力增加,这是生物膜内氧通量及氨氮去除负荷随生物膜厚度先增加后下降的内在原因。展开更多
基金Project supported by the Cooperation Program of China and Singapore(Grant No.042307013)
文摘The orthogonal experiments, which involves three factors: aeration intensity, suction time and suction suspended time, were designed to research membrane fouling of jet loop membrane bioreactor (JLMBR). Experimental results indicate that increasing aeration intensity, reducing suction time and increasing suction suspended time all could mitigate membrane fouling effectively. However excessive aeration intensity, too short suction time and excessive suction suspended time were bad for bioreactor running. The optimal aeration intensity, suction time and suction suspended time were 0.75 1.00 m3/(m2.h), 8 -10 min and 4 -5 min, respectively. The three factors all had effect on membrane pollution rate, while the suction time was the most important one and followed by aeration intensity and suction suspended time. It also indicates that, comparing with traditional submerged membrane bioreactors, JLMBR had lower membrane pollution rate.
文摘在设定的膜内压力下(2 k Pa)启动并运行膜曝气生物膜反应器(MABR),对生物膜生长过程中的硝化性能及生物膜组成变化进行了分析。实验结果表明,在生物膜厚度增长到(293.3±5.8)μm的过程中,生物膜内的总氧通量先增加后减少,最高可达21.3 g O2?m?2?d?1,证实了生物膜的存在可增强MABR的氧传质能力。在生物膜厚度增长的过程中,氨氮表面去除负荷也是先增加后减少,最高可达4.91 g N?m?2?d?1,表明在MABR硝化过程中存在最佳的生物膜厚度,根据所研究最佳生物膜厚度为(119.0±3.0)μm,此时MABR具有最高的氧通量和氨氮表面去除负荷,硝化性能最好。生物膜内胞外聚合物(EPS)成分分析结果表明,随着生物膜厚度的增加,生物膜内层紧密型EPS的含量增加,导致氧传质阻力增加,这是生物膜内氧通量及氨氮去除负荷随生物膜厚度先增加后下降的内在原因。