In order to design the technological process of desalination by electrodialysis for the industrial wastewater of an alumina plant, the limit current density of the industrial wastewater is measured, and the equations ...In order to design the technological process of desalination by electrodialysis for the industrial wastewater of an alumina plant, the limit current density of the industrial wastewater is measured, and the equations of limit current density, voltage drop of the unit membrane pair at the limiting current and desalination ratio at the limiting current were obtained.展开更多
Selective electrodialysis(SED)has surfaced as a highly promising membrane separation technique in the realm of acid recovery owing to its ability to effectively separate monovalent ions through the utilization of a po...Selective electrodialysis(SED)has surfaced as a highly promising membrane separation technique in the realm of acid recovery owing to its ability to effectively separate monovalent ions through the utilization of a potential difference.However,the current SED process is limited by conventional commercial monovalent cation permselective membranes(MCPMs).This study systematically investigates the use of an independently developed MCPM in the SED process for acid recovery.Various factors such as current density,volume ratio,initial ion concentration,and waste acid systems are considered.The independently developed MCPM offers several advantages over the commercial monovalent selective cation-exchange membrane(CIMS),including higher recovered acid concentration,better ion flux ratio,improved acid recovery efficiency,increased recovered acid purity,and higher current efficiency.The SED process with the MCPM achieves a recovered acid of 95.9%and a concentration of 2.3 mol·L^(–1) in the HCl/FeCl_(2) system,when a current density of 20 mA·cm^(-2) and a volume ratio of 1:2 are applied.Similarly,in the H_(2)SO_(4)/FeSO_(4) system,a purity of over 99%and a concentration of 2.1 mol·L^(–1) can be achieved in the recovered acid.This study thoroughly examines the impact of operation conditions on acid recovery performance in the SED process.The independently developed MCPM demonstrates outstanding acid recovery performance,highlighting its potential for future commercial utilization.展开更多
The experimental results of producing deionized water for the themoelectric factory from two types of the industrial wastewater of an alumina plant by using membrane technology are reported in this paper. For the trea...The experimental results of producing deionized water for the themoelectric factory from two types of the industrial wastewater of an alumina plant by using membrane technology are reported in this paper. For the treatment of the industrial wastewater with high salinity and pH value, the combination of electrodialysis (ED) and reverse osmosis (RO) is utilized, while for the treatment of the low salinity wastewater with low pH value, RO is directly used. The research results show that the above mentioned methods are effective. The technological process of the wastewater treatment with the capacity of 120 tons is designed on the basis of the experimental results.展开更多
糠醛废水含1~2.5%的乙酸,直接外排,污染环境,浪费资源。通过60—80对膜组装的400×800 mm 电渗析器中型试验,回收了浓度为20%的乙酸,再经萃取—精馏得到99%工业乙酸,治理后的废水含酸量<0.02%,可安全排放及回用。本文探讨了影...糠醛废水含1~2.5%的乙酸,直接外排,污染环境,浪费资源。通过60—80对膜组装的400×800 mm 电渗析器中型试验,回收了浓度为20%的乙酸,再经萃取—精馏得到99%工业乙酸,治理后的废水含酸量<0.02%,可安全排放及回用。本文探讨了影响过程性能的因素,为安全操作、放大设计提供了依据。展开更多
文摘In order to design the technological process of desalination by electrodialysis for the industrial wastewater of an alumina plant, the limit current density of the industrial wastewater is measured, and the equations of limit current density, voltage drop of the unit membrane pair at the limiting current and desalination ratio at the limiting current were obtained.
基金supported by the National Key Research and Development Program of China(2022YFB3805100)National Natural Science Foundation of China(22222812 and 22178330)+1 种基金Anhui Provincial Key Research and Development Plan(202104b11020030)Major Science and Technology Innovation Projects in Shandong Province(2022CXGC020415).
文摘Selective electrodialysis(SED)has surfaced as a highly promising membrane separation technique in the realm of acid recovery owing to its ability to effectively separate monovalent ions through the utilization of a potential difference.However,the current SED process is limited by conventional commercial monovalent cation permselective membranes(MCPMs).This study systematically investigates the use of an independently developed MCPM in the SED process for acid recovery.Various factors such as current density,volume ratio,initial ion concentration,and waste acid systems are considered.The independently developed MCPM offers several advantages over the commercial monovalent selective cation-exchange membrane(CIMS),including higher recovered acid concentration,better ion flux ratio,improved acid recovery efficiency,increased recovered acid purity,and higher current efficiency.The SED process with the MCPM achieves a recovered acid of 95.9%and a concentration of 2.3 mol·L^(–1) in the HCl/FeCl_(2) system,when a current density of 20 mA·cm^(-2) and a volume ratio of 1:2 are applied.Similarly,in the H_(2)SO_(4)/FeSO_(4) system,a purity of over 99%and a concentration of 2.1 mol·L^(–1) can be achieved in the recovered acid.This study thoroughly examines the impact of operation conditions on acid recovery performance in the SED process.The independently developed MCPM demonstrates outstanding acid recovery performance,highlighting its potential for future commercial utilization.
文摘The experimental results of producing deionized water for the themoelectric factory from two types of the industrial wastewater of an alumina plant by using membrane technology are reported in this paper. For the treatment of the industrial wastewater with high salinity and pH value, the combination of electrodialysis (ED) and reverse osmosis (RO) is utilized, while for the treatment of the low salinity wastewater with low pH value, RO is directly used. The research results show that the above mentioned methods are effective. The technological process of the wastewater treatment with the capacity of 120 tons is designed on the basis of the experimental results.