The paper investigated the equivalent continuum modeling of beam-like repetitive truss structures considering the flexibility of joints,which models the contact between the truss member and joint by spring-damper with...The paper investigated the equivalent continuum modeling of beam-like repetitive truss structures considering the flexibility of joints,which models the contact between the truss member and joint by spring-damper with six directional stiffnesses and dampings.Firstly,a two-node hybrid joint-beam element was derived for modeling the truss member with flexible end joints,and a condensed model for the repeating element with flexible joints was obtained.Then,the energy equivalence method was adopted to equivalently model the truss structure with flexible joints and material damping as a spatial viscoelastic anisotropic beam model.Afterwards,the equations of motion for the equivalent beam model were derived and solved analytically in the frequency domain.In the numerical studies,the correctness of the presented method was verified by comparisons of the natural frequencies and frequency responses evaluated by the equivalent beam model with the results of the finite element method model.展开更多
Joints are necessary components in the larger space deployable truss structures which have significant effect on the dynamics behavior of these deployable joint-dominated structures. Four kinds of joints' nonlinea...Joints are necessary components in the larger space deployable truss structures which have significant effect on the dynamics behavior of these deployable joint-dominated structures. Four kinds of joints' nonlinear force-displacement relationship are analyzed based on describing function method. The dynamic responses of one-DOF jointed system under different exciting force levels are investigated to understand the influence of joint nonlinearity on dynamic responses. The influences of joint characterizing parameters on joint nonlinearities are analyzed. Dynamic responses of the modular beam-like deployable joint-dominated truss structure are tested under different sinusoidal exciting force levels. The experimental results show obvious nonlinear behaviors contributed by joints that dynamic response shifts to lower resonance frequency and higher amplitude with the increase of exciting force. The nonlinearity of the joints in the tested structure is compared with the theoretical results and identified to meet with the hysteresis nonlinearity.展开更多
Steel truss bridges are frequently used in bridge engineering because of their good ability of spanning capacity, construction and light self-weight. Main trusses are the critical component of steel truss bridge and t...Steel truss bridges are frequently used in bridge engineering because of their good ability of spanning capacity, construction and light self-weight. Main trusses are the critical component of steel truss bridge and the main truss are made of truss members linked by integral joints. This paper presents the mechanic performance of key joints, and the codified design of joints in steel truss girders according to the latest European norms. The results showed that the fatigue resistance of welded joints evaluation is necessary to predict, detect, and repair the crack in time for the safety service life of the bridge. The stresses of integral joint are greater than that of truss members;the stresses in the center area of the integral joint are greater than the stress at the edge.展开更多
基金This work was supported by the National Natural Science Foundation of China(Grants 11702146,11732006 and 11827801)the Equipment Pre-research Foundation(Grant 6140210010202).
文摘The paper investigated the equivalent continuum modeling of beam-like repetitive truss structures considering the flexibility of joints,which models the contact between the truss member and joint by spring-damper with six directional stiffnesses and dampings.Firstly,a two-node hybrid joint-beam element was derived for modeling the truss member with flexible end joints,and a condensed model for the repeating element with flexible joints was obtained.Then,the energy equivalence method was adopted to equivalently model the truss structure with flexible joints and material damping as a spatial viscoelastic anisotropic beam model.Afterwards,the equations of motion for the equivalent beam model were derived and solved analytically in the frequency domain.In the numerical studies,the correctness of the presented method was verified by comparisons of the natural frequencies and frequency responses evaluated by the equivalent beam model with the results of the finite element method model.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50935002 and 11002039)Key Laboratory Opening Funding of Aerospace Mechanism and Control Technology(Grant No.HIT.KLOF.2009062)"111 Project"(Grant No.B07018)
文摘Joints are necessary components in the larger space deployable truss structures which have significant effect on the dynamics behavior of these deployable joint-dominated structures. Four kinds of joints' nonlinear force-displacement relationship are analyzed based on describing function method. The dynamic responses of one-DOF jointed system under different exciting force levels are investigated to understand the influence of joint nonlinearity on dynamic responses. The influences of joint characterizing parameters on joint nonlinearities are analyzed. Dynamic responses of the modular beam-like deployable joint-dominated truss structure are tested under different sinusoidal exciting force levels. The experimental results show obvious nonlinear behaviors contributed by joints that dynamic response shifts to lower resonance frequency and higher amplitude with the increase of exciting force. The nonlinearity of the joints in the tested structure is compared with the theoretical results and identified to meet with the hysteresis nonlinearity.
文摘Steel truss bridges are frequently used in bridge engineering because of their good ability of spanning capacity, construction and light self-weight. Main trusses are the critical component of steel truss bridge and the main truss are made of truss members linked by integral joints. This paper presents the mechanic performance of key joints, and the codified design of joints in steel truss girders according to the latest European norms. The results showed that the fatigue resistance of welded joints evaluation is necessary to predict, detect, and repair the crack in time for the safety service life of the bridge. The stresses of integral joint are greater than that of truss members;the stresses in the center area of the integral joint are greater than the stress at the edge.