BACKGROUND A meshoma formation and erosion to the small intestine is rare.Herein,we report one case of a meshoma that was not treated early;causing it to displace and erode the small intestine,with infection,complete ...BACKGROUND A meshoma formation and erosion to the small intestine is rare.Herein,we report one case of a meshoma that was not treated early;causing it to displace and erode the small intestine,with infection,complete control of symptoms was achieved after removal of the infected patch mass,no recurrence of hernia after 2 years of follow-up.CASE SUMMARY A 62-year-old male patient presented with recurrent abdominal pain repeatedly for 1 wk,which has worsened 2 d before admition,accompanied by fever.Five years before presentation he underwent right inguinal hernia Plug and patch repair approach.Two years ago,a computed tomography scan revealed a right lower abdominal mass with soft tissue density,measuring approximately 30 mm×17 mm,which was diagnosed as meshoma that was not treated.The patient had poorly controlled diabetes in the past year.CONCLUSION The formation of meshoma is rare,and that if not treated in time it might erode and require resection of the involved organ.展开更多
AIM To outline current evidence regarding prevention and treatment of parastomal hernia and to compare use of synthetic and biologic mesh.METHODS Relevant databases were searched for studies reporting hernia recurrenc...AIM To outline current evidence regarding prevention and treatment of parastomal hernia and to compare use of synthetic and biologic mesh.METHODS Relevant databases were searched for studies reporting hernia recurrence, wound and mesh infection, other complications, surgical techniques and mortality. Weighted pooled proportions (95%CI) were calculated using StatsDirect. Heterogeneity concerning outcome mea-sures was determined using Cochran’s Q test and was quantifed using I2. Random and fxed effects models were used. Meta-analysis was performed with Review Manager software with the statistical signifcance set at P ≤ 0.05.RESULTSForty-four studies were included: 5 reporting biologic mesh repairs; 21, synthetic mesh repairs; and 18, prophylactic mesh repairs. Most of the studies were retrospective cohorts of low to moderate quality. The hernia recurrence rate was higher after undergoing biologic compared to synthetic mesh repair (24.0% vs 15.1%, P = 0.01). No significant difference was found concerning wound and mesh infection (5.6% vs 2.8%; 0% vs 3.1%). Open and laparoscopic techniques were comparable regarding recurrences and infections. Prophylactic mesh placement reduced the occurrence of a parastomal hernia (OR = 0.20, P 〈 0.0006) without increasing wound infection [7.8% vs 8.2% (OR = 1.04, P = 0.91)] and without differences between the mesh types.展开更多
BACKGROUND Sacrococcygeal hernia is a very rare condition that is usually secondary to sacrococcygectomy, and its ideal treatment regimen is unclear. Herein, we report a case of sacrococcygeal hernia occurring in a pa...BACKGROUND Sacrococcygeal hernia is a very rare condition that is usually secondary to sacrococcygectomy, and its ideal treatment regimen is unclear. Herein, we report a case of sacrococcygeal hernia occurring in a patient who had no history of sacrococcygeal operation, present the operative procedures of mesh repair via a combined laparoscopic and sacrococcygeal approach that has not been described,and discuss our experience in diagnosis and treatment with a review of the literature.CASE SUMMARY A 54-year-old woman who chiefly complained of a 10-year history of a reversible bulge in her right sacrococcygeal region was admitted to our hospital. The physical examination revealed a bulge in the right sacrococcygeal region upon standing, which disappeared in the prone position but relapsed when performing the Valsalva manoeuvre. Computed tomography displayed an abnormality in the structure of the tissues between the midline of the sacrococcygeal region and the right gluteus muscle. The patient was diagnosed with sacrococcygeal hernia and received hernia repair with mesh through a combined laparoscopic and sacrococcygeal approach. On laparoscopy, the rectum was dissected posterolaterally, and a defect was identified in the right anterior sacrococcygeal region through which part of the rectum protruded. This was followed by the placement of a self-gripping polyester mesh via a sacrococcygeal approach. There were no postoperative complications. The patient was discharged on postoperative day 7 and was followed for more than 6 mo with no recurrence.CONCLUSION Laparoscopic mesh repair is recommended as a priority of surgical options for sacrococcygeal hernias, while choosing a self-gripping mesh can help avoid the risk of presacral vessel injury by reducing suture fixation.展开更多
<strong>Rationale:</strong> The three-dimensional (3D) computer-made titanium mesh is widely used in the skull repair for those patients receiving decompression of the bone flap. It can restore normal anat...<strong>Rationale:</strong> The three-dimensional (3D) computer-made titanium mesh is widely used in the skull repair for those patients receiving decompression of the bone flap. It can restore normal anatomy to a greater extent and make a better appearance. <strong>Case Presentation: </strong>We reported two cases of patients admitted to our hospital who have experienced high scalp tension after skull repair. At first, these two patients underwent decompression of the bone flap, and the physical examination results showed a defect of skull. No neurological symptoms and signs were found. The 3D computed tomography (CT) reconstruction of skull was performed, and then the skull repair with 3D titanium mesh was conducted. But because of high scalp tension, they underwent a second operation, during which we re-trimmed and reduce the arc of the titanium mesh. The scalp incision of both patients healed well and no titanium mesh was exposed. Both patients have a good prognosis. <strong>Lessons:</strong> We highlight that the high tension of scalp due to overstretching after 3D titanium mesh repair for skull defect should be paid much attention to. Trimming and reducing the arc of titanium mesh is an effective treatment for this situation.展开更多
Objective To explore the application of scalp rotation flap in reconstruction of infectious scalp defect with titanium mesh exposure. Methods Twelve patients were treated in this group including 4 males and 8 female. ...Objective To explore the application of scalp rotation flap in reconstruction of infectious scalp defect with titanium mesh exposure. Methods Twelve patients were treated in this group including 4 males and 8 female. S The defective size ranged from 2. 0 cm × 5. 0 cm to 0.展开更多
Chronic Groin Pain (Inguinodynia) following inguinal hernia repair is a significant,though under-reported problem. Mild pain lasting for a few days is common following mesh inguinal hernia repair. However,moderate to ...Chronic Groin Pain (Inguinodynia) following inguinal hernia repair is a significant,though under-reported problem. Mild pain lasting for a few days is common following mesh inguinal hernia repair. However,moderate to severe pain persisting more than 3 mo after inguinal herniorrhaphy should be considered as pathological. The major reasons for chronic groin pain have been identified as neuropathic cause due to inguinal nerve(s) damage or non-neuropathic cause due to mesh or other related factors. The symptom complex of chronic groin pain varies from a dull ache to sharp shooting pain along the distribution of inguinal nerves. Thorough history and meticulous clinical examination should be performed to identify the exact cause of chronic groin pain,as there is no single test to confirm the aetiology behind the pain or to point out the exact nerve involved. Various studies have been performed to look at the difference in chronic groin pain rates with the use of mesh vs non-mesh repair,use of heavyweight vs lightweight mesh and mesh fixation with sutures vs glue. Though there is no convincing evidence favouring one over the other,lightweight meshes are generally preferred because of their lesser foreign body reaction and better tolerance by the patients. Identification of all three nerves has been shown to be an important factor in reducing chronic groin pain,though there are no well conducted randomised studies to recommend the benefits of nerve excision vs preservation. Both nonsurgical and surgical options have been tried for chronic groin pain,with their consequent risks of analgesic sideeffects,recurrent pain,recurrent hernia and significant sensory loss. By far the best treatment for chronic groin pain is to avoid bestowing this on the patient by careful intra-operative handling of inguinal structures and better patient counselling pre-and post-herniorraphy.展开更多
Although mesenterioaxial gastric volvulus is an uncommon entity characterized by rotation at the transverse axis of the stomach, laparoscopic repair procedures have still been controversial. We reported a case of mese...Although mesenterioaxial gastric volvulus is an uncommon entity characterized by rotation at the transverse axis of the stomach, laparoscopic repair procedures have still been controversial. We reported a case of mesenterioaxial intrathoracic gastric volvulus, which was successfully treated with laparoscopic repair of the diaphragmatic hiatal defect using a polytetrafluoroethylene mesh associated with Toupet fundoplication. A 70-year-old Japanese woman was admitted to our hospital because of sudden onset of upper abdominal pain. An upper gastrointestinal series revealed an incarcerated intrathoracic mesenterioaxial volvulus of the distal portion of the stomach and the duodenum. The complete laparoscopic approach was used to repair the volvulus. The laparoscopic procedures involved the repair of the hiatal hernia using polytetrafluoroethylene mesh and Toupet fundoplication. This case highlights the feasibility and effectiveness of the laparoscopic procedure, and laparoscopic repair of the hiatal defect using a polytetrafluoroethylene mesh associated with Toupet fundoplication may be useful for preventing postoperative recurrence of hiatal her-nia, volvulus, and gastroesophageal reflux.展开更多
Perineal hernia is a rare complication of anterior exenteration.We reported this complication after an anterior exenteration for bladder cancer with bleeding complication requiring packing and second-look laparotomy.P...Perineal hernia is a rare complication of anterior exenteration.We reported this complication after an anterior exenteration for bladder cancer with bleeding complication requiring packing and second-look laparotomy.Perineal approach is a simple and effective method for repair of perineal hernia.展开更多
Objective:The objective of this article is to systematically analyse the randomized,controlled trials comparing transinguinal preperitoneal(TIPP)and Lichtenstein repair(LR)for inguinal hernia.Methods:Randomized,contro...Objective:The objective of this article is to systematically analyse the randomized,controlled trials comparing transinguinal preperitoneal(TIPP)and Lichtenstein repair(LR)for inguinal hernia.Methods:Randomized,controlled trials comparing TIPP vs LR were analysed systematically using RevMan®and combined outcomes were expressed as risk ratio(RR)and standardized mean difference.Results:Twelve randomized trials evaluating 1437 patients were retrieved from the electronic databases.There were 714 patients in the TIPP repair group and 723 patients in the LR group.There was significant heterogeneity among trials(P<0.0001).Therefore,in the random effects model,TIPP repair was associated with a reduced risk of developing chronic groin pain(RR,0.48;95%CI,0.26,0.89;z=2.33;P<0.02)without influencing the incidence of inguinal hernia recurrence(RR,0.18;95%CI,0.36,1.83;z=0.51;P=0.61).Risk of developing postoperative complications and moderate-to-severe postoperative pain was similar following TIPP repair and LR.In addition,duration of operation was statistically similar in both groups.Conclusion:TIPP repair for inguinal hernia is associated with lower risk of developing chronic groin pain.It is comparable with LR in terms of risk of hernia recurrence,postoperative complications,duration of operation and intensity of postoperative pain.展开更多
Surface triangle meshes and volume data are two commonly used representations of digital geometry. Converting from triangle meshes to volume data is challenging, since triangle meshes often contain defects such as sma...Surface triangle meshes and volume data are two commonly used representations of digital geometry. Converting from triangle meshes to volume data is challenging, since triangle meshes often contain defects such as small holes, internal structures, or self-intersections. In the extreme case, we may be simply presented with a set of arbitrarily connected triangles, a "triangle soup". This paper presents a novel method to generate volume data represented as an octree from a general 3D triangle soup. Our motivation is the Faraday cage from electrostatics. We consider the input triangles as forming an approximately closed Faraday cage, and set its potential to zero. We then introduce a second conductor surrounding it, and give it a higher constant potential. Due to the electrostatic shielding effect, the resulting electric field approximately lies in that part of space outside the shape implicitly determined by the triangle soup. Unlike previous approaches, our method is insensitive to small holes and internal structures, and is observed to generate volumes with low topological complexity. While our approach is somewhat limited in accuracy by the requirement of filling holes, it is still useful, for example, as a preprocessing step for applications such as mesh repair and skeleton extraction.展开更多
文摘BACKGROUND A meshoma formation and erosion to the small intestine is rare.Herein,we report one case of a meshoma that was not treated early;causing it to displace and erode the small intestine,with infection,complete control of symptoms was achieved after removal of the infected patch mass,no recurrence of hernia after 2 years of follow-up.CASE SUMMARY A 62-year-old male patient presented with recurrent abdominal pain repeatedly for 1 wk,which has worsened 2 d before admition,accompanied by fever.Five years before presentation he underwent right inguinal hernia Plug and patch repair approach.Two years ago,a computed tomography scan revealed a right lower abdominal mass with soft tissue density,measuring approximately 30 mm×17 mm,which was diagnosed as meshoma that was not treated.The patient had poorly controlled diabetes in the past year.CONCLUSION The formation of meshoma is rare,and that if not treated in time it might erode and require resection of the involved organ.
文摘AIM To outline current evidence regarding prevention and treatment of parastomal hernia and to compare use of synthetic and biologic mesh.METHODS Relevant databases were searched for studies reporting hernia recurrence, wound and mesh infection, other complications, surgical techniques and mortality. Weighted pooled proportions (95%CI) were calculated using StatsDirect. Heterogeneity concerning outcome mea-sures was determined using Cochran’s Q test and was quantifed using I2. Random and fxed effects models were used. Meta-analysis was performed with Review Manager software with the statistical signifcance set at P ≤ 0.05.RESULTSForty-four studies were included: 5 reporting biologic mesh repairs; 21, synthetic mesh repairs; and 18, prophylactic mesh repairs. Most of the studies were retrospective cohorts of low to moderate quality. The hernia recurrence rate was higher after undergoing biologic compared to synthetic mesh repair (24.0% vs 15.1%, P = 0.01). No significant difference was found concerning wound and mesh infection (5.6% vs 2.8%; 0% vs 3.1%). Open and laparoscopic techniques were comparable regarding recurrences and infections. Prophylactic mesh placement reduced the occurrence of a parastomal hernia (OR = 0.20, P 〈 0.0006) without increasing wound infection [7.8% vs 8.2% (OR = 1.04, P = 0.91)] and without differences between the mesh types.
文摘BACKGROUND Sacrococcygeal hernia is a very rare condition that is usually secondary to sacrococcygectomy, and its ideal treatment regimen is unclear. Herein, we report a case of sacrococcygeal hernia occurring in a patient who had no history of sacrococcygeal operation, present the operative procedures of mesh repair via a combined laparoscopic and sacrococcygeal approach that has not been described,and discuss our experience in diagnosis and treatment with a review of the literature.CASE SUMMARY A 54-year-old woman who chiefly complained of a 10-year history of a reversible bulge in her right sacrococcygeal region was admitted to our hospital. The physical examination revealed a bulge in the right sacrococcygeal region upon standing, which disappeared in the prone position but relapsed when performing the Valsalva manoeuvre. Computed tomography displayed an abnormality in the structure of the tissues between the midline of the sacrococcygeal region and the right gluteus muscle. The patient was diagnosed with sacrococcygeal hernia and received hernia repair with mesh through a combined laparoscopic and sacrococcygeal approach. On laparoscopy, the rectum was dissected posterolaterally, and a defect was identified in the right anterior sacrococcygeal region through which part of the rectum protruded. This was followed by the placement of a self-gripping polyester mesh via a sacrococcygeal approach. There were no postoperative complications. The patient was discharged on postoperative day 7 and was followed for more than 6 mo with no recurrence.CONCLUSION Laparoscopic mesh repair is recommended as a priority of surgical options for sacrococcygeal hernias, while choosing a self-gripping mesh can help avoid the risk of presacral vessel injury by reducing suture fixation.
文摘<strong>Rationale:</strong> The three-dimensional (3D) computer-made titanium mesh is widely used in the skull repair for those patients receiving decompression of the bone flap. It can restore normal anatomy to a greater extent and make a better appearance. <strong>Case Presentation: </strong>We reported two cases of patients admitted to our hospital who have experienced high scalp tension after skull repair. At first, these two patients underwent decompression of the bone flap, and the physical examination results showed a defect of skull. No neurological symptoms and signs were found. The 3D computed tomography (CT) reconstruction of skull was performed, and then the skull repair with 3D titanium mesh was conducted. But because of high scalp tension, they underwent a second operation, during which we re-trimmed and reduce the arc of the titanium mesh. The scalp incision of both patients healed well and no titanium mesh was exposed. Both patients have a good prognosis. <strong>Lessons:</strong> We highlight that the high tension of scalp due to overstretching after 3D titanium mesh repair for skull defect should be paid much attention to. Trimming and reducing the arc of titanium mesh is an effective treatment for this situation.
文摘Objective To explore the application of scalp rotation flap in reconstruction of infectious scalp defect with titanium mesh exposure. Methods Twelve patients were treated in this group including 4 males and 8 female. S The defective size ranged from 2. 0 cm × 5. 0 cm to 0.
文摘Chronic Groin Pain (Inguinodynia) following inguinal hernia repair is a significant,though under-reported problem. Mild pain lasting for a few days is common following mesh inguinal hernia repair. However,moderate to severe pain persisting more than 3 mo after inguinal herniorrhaphy should be considered as pathological. The major reasons for chronic groin pain have been identified as neuropathic cause due to inguinal nerve(s) damage or non-neuropathic cause due to mesh or other related factors. The symptom complex of chronic groin pain varies from a dull ache to sharp shooting pain along the distribution of inguinal nerves. Thorough history and meticulous clinical examination should be performed to identify the exact cause of chronic groin pain,as there is no single test to confirm the aetiology behind the pain or to point out the exact nerve involved. Various studies have been performed to look at the difference in chronic groin pain rates with the use of mesh vs non-mesh repair,use of heavyweight vs lightweight mesh and mesh fixation with sutures vs glue. Though there is no convincing evidence favouring one over the other,lightweight meshes are generally preferred because of their lesser foreign body reaction and better tolerance by the patients. Identification of all three nerves has been shown to be an important factor in reducing chronic groin pain,though there are no well conducted randomised studies to recommend the benefits of nerve excision vs preservation. Both nonsurgical and surgical options have been tried for chronic groin pain,with their consequent risks of analgesic sideeffects,recurrent pain,recurrent hernia and significant sensory loss. By far the best treatment for chronic groin pain is to avoid bestowing this on the patient by careful intra-operative handling of inguinal structures and better patient counselling pre-and post-herniorraphy.
基金Supported by The Department of Surgery Fujita Health University School of Medicine and University Hospital
文摘Although mesenterioaxial gastric volvulus is an uncommon entity characterized by rotation at the transverse axis of the stomach, laparoscopic repair procedures have still been controversial. We reported a case of mesenterioaxial intrathoracic gastric volvulus, which was successfully treated with laparoscopic repair of the diaphragmatic hiatal defect using a polytetrafluoroethylene mesh associated with Toupet fundoplication. A 70-year-old Japanese woman was admitted to our hospital because of sudden onset of upper abdominal pain. An upper gastrointestinal series revealed an incarcerated intrathoracic mesenterioaxial volvulus of the distal portion of the stomach and the duodenum. The complete laparoscopic approach was used to repair the volvulus. The laparoscopic procedures involved the repair of the hiatal hernia using polytetrafluoroethylene mesh and Toupet fundoplication. This case highlights the feasibility and effectiveness of the laparoscopic procedure, and laparoscopic repair of the hiatal defect using a polytetrafluoroethylene mesh associated with Toupet fundoplication may be useful for preventing postoperative recurrence of hiatal her-nia, volvulus, and gastroesophageal reflux.
文摘Perineal hernia is a rare complication of anterior exenteration.We reported this complication after an anterior exenteration for bladder cancer with bleeding complication requiring packing and second-look laparotomy.Perineal approach is a simple and effective method for repair of perineal hernia.
文摘Objective:The objective of this article is to systematically analyse the randomized,controlled trials comparing transinguinal preperitoneal(TIPP)and Lichtenstein repair(LR)for inguinal hernia.Methods:Randomized,controlled trials comparing TIPP vs LR were analysed systematically using RevMan®and combined outcomes were expressed as risk ratio(RR)and standardized mean difference.Results:Twelve randomized trials evaluating 1437 patients were retrieved from the electronic databases.There were 714 patients in the TIPP repair group and 723 patients in the LR group.There was significant heterogeneity among trials(P<0.0001).Therefore,in the random effects model,TIPP repair was associated with a reduced risk of developing chronic groin pain(RR,0.48;95%CI,0.26,0.89;z=2.33;P<0.02)without influencing the incidence of inguinal hernia recurrence(RR,0.18;95%CI,0.36,1.83;z=0.51;P=0.61).Risk of developing postoperative complications and moderate-to-severe postoperative pain was similar following TIPP repair and LR.In addition,duration of operation was statistically similar in both groups.Conclusion:TIPP repair for inguinal hernia is associated with lower risk of developing chronic groin pain.It is comparable with LR in terms of risk of hernia recurrence,postoperative complications,duration of operation and intensity of postoperative pain.
基金supported by the National Basic Research 973 Program of China under Grant No. 2006CB303106the National Natural Science Foundation of China under Grant Nos. 90718035 and U0735001
文摘Surface triangle meshes and volume data are two commonly used representations of digital geometry. Converting from triangle meshes to volume data is challenging, since triangle meshes often contain defects such as small holes, internal structures, or self-intersections. In the extreme case, we may be simply presented with a set of arbitrarily connected triangles, a "triangle soup". This paper presents a novel method to generate volume data represented as an octree from a general 3D triangle soup. Our motivation is the Faraday cage from electrostatics. We consider the input triangles as forming an approximately closed Faraday cage, and set its potential to zero. We then introduce a second conductor surrounding it, and give it a higher constant potential. Due to the electrostatic shielding effect, the resulting electric field approximately lies in that part of space outside the shape implicitly determined by the triangle soup. Unlike previous approaches, our method is insensitive to small holes and internal structures, and is observed to generate volumes with low topological complexity. While our approach is somewhat limited in accuracy by the requirement of filling holes, it is still useful, for example, as a preprocessing step for applications such as mesh repair and skeleton extraction.