期刊文献+
共找到51,611篇文章
< 1 2 250 >
每页显示 20 50 100
Collapse Behavior of Pipe-Framed Greenhouses with and without Reinforcement under Snow Loading:A 3-D Finite Element Analysis
1
作者 Yasushi Uematsu Kazuya Takahashi 《Journal of Civil Engineering and Architecture》 2024年第2期51-59,共9页
The present paper first investigates the collapse behavior of a conventional pipe-framed greenhouse under snow loading based on a 3-D finite element analysis,in which both geometrical and material non-linearities are ... The present paper first investigates the collapse behavior of a conventional pipe-framed greenhouse under snow loading based on a 3-D finite element analysis,in which both geometrical and material non-linearities are considered.Three snow load distribution patterns related to the wind-driven snow particle movement are used in the analysis.It is found that snow load distribution affects the deformation and collapse behavior of the pipe-framed greenhouse significantly.The results obtained in this study are consistent with the actual damage observed.Next,discussion is made of the effects of reinforcements by adding members to the basic frame on the strength of the whole structure,in which seven kinds of reinforcement methods are examined.A buckling analysis is also carried out.The results indicate that the most effective reinforcement method depends on the snow load distribution pattern. 展开更多
关键词 Pipe-framed greenhouse snow loading COLLAPSE BUCKLING finite element analysis
下载PDF
Finite Element Analysis of Coronal Shear Fractures of the Femoral Neck: Displacement of the Femoral Head and Effect of Osteosynthetic Implants
2
作者 Yukino Mori Hiroaki Kijima +2 位作者 Mei Terashi Takehiro Iwami Naohisa Miyakoshi 《World Journal of Engineering and Technology》 2024年第3期651-664,共14页
Coronal shear fractures of the femoral neck (CSFF) are the most challenging to treat among proximal femur fractures, directly affecting the life expectancy of patients with osteoporosis. However, an adequate osteosynt... Coronal shear fractures of the femoral neck (CSFF) are the most challenging to treat among proximal femur fractures, directly affecting the life expectancy of patients with osteoporosis. However, an adequate osteosynthesis method has not been elucidated yet. This study investigated the displacement direction of the femoral head fragment and its effect on the bone using finite element method. A finite element model for CSFF was developed from CT image data of a patient with osteoporosis using Mechanical Finder (ver. 11). Subsequently, finite element analyses were performed on six osteosynthesis models under maximum load applied during walking. The compressive stresses, tensile stresses, and compressive strains of each model were examined. The results suggested that the compressive and tensile stress distributions were concentrated on the anterior side of the femoral neck. Compressive strain distribution in the femoral head and neck was concentrated in four areas: at the tip of the blade or lag screw, the anteroinferior side of the blade or lag screw near the fracture site, and the upper right and lower left near the junction of the blade or lag screw and nail. Thus, the distribution of both these stresses revealed that the femoral head fragment was prone to anterior and inferior displacement. Distribution of compressive strains revealed the direction of the stress exerted by the osteosynthetic implant on the bone. The same results were observed in all osteosynthetic implants;thus, the findings could lay the foundation for developing methods for placing osteosynthetic implants less prone to displacement and the osteosynthetic implants themselves. In particular, the study provides insight into the optimal treatment of CSFF. 展开更多
关键词 finite element analysis Proximal Femur Fractures Intramedullary Fixation Coronal Shear Fractures Femoral Neck
下载PDF
Stress Distributions Created by Short and Regular Implants Placed in the Anterior Maxilla at Different Angles: A Finite Element Analysis
3
作者 Mehmet Fatih Özmen Funda Bayındır 《Open Journal of Stomatology》 2023年第1期32-49,共18页
Although short implants are seen as alternative treatments that require additional surgical techniques in posterior region, they can be applied to anterior maxilla and various studies are required on this subject. The... Although short implants are seen as alternative treatments that require additional surgical techniques in posterior region, they can be applied to anterior maxilla and various studies are required on this subject. The purpose of this study was to examine and compare the peak von Mises stress distributions in the crown, implant and abutment by using finite element analysis (FEA). Besides, a comparison of the implant-abutment connection types in the short implant with the FEA method was established. A short implant (4 × 5 mm) with a taper-lock connection and a regular implant (4 × 9 mm) with a screw connection were used in maxillary central incisor tooth area. Three different titanium abutments with 0?, 15? and 25? angles were used for abutments. In addition, in order to determine whether the stress change in short implants is due to the length of the implant-abutment connection, a screw was designed for a short implant and it was also evaluated in the same three angles. A total of three groups and nine models were generated. 114.6N load was applied to the cingulum area of the crown at an angle of 135? to the long axis of the crowns. A torque load of 25 Ncm was applied to the regular and short implant screw. Von Mises stress distributions of implants, abutments and crowns were evaluated by using FEA. Increased angle in implants increased von Mises stress values of implant, abutment and crown. Screw connection was found higher at all angles in short implants. Close values were found at different angles in taper-lock short implant crowns. The length and the angle in the bone of implant with the type of implant-abutment connection results in the accumulated stress values. Clinical Implications Taper implant-abutment connection system was found to be more promising in terms of stress accumulation in crowns. Although the amount of stress on the abutment increased due to the length of the implant in short implants, taper implant-abutment connection system slightly reduced related to this increase. 展开更多
关键词 Anterior Maxilla finite element analysis Von Mises Short Implant
下载PDF
Study on Development of Light Aluminum Step by Using Finite Element Analysis
4
作者 WU Jianlong 《International Journal of Plant Engineering and Management》 2023年第4期232-248,共17页
In order to ensure the safe operation of the escalator,the step as a part of transporting passengers,the design will consider a high safety factor,which will increase the weight,the manufacturing cost,and the energy c... In order to ensure the safe operation of the escalator,the step as a part of transporting passengers,the design will consider a high safety factor,which will increase the weight,the manufacturing cost,and the energy consumption of the steps band operation.Therefore,in order to reduce the weight and ensure the strength and stiffness of the step,through the optimization design,the number of reinforcing rib supports of the step tread plate and riser plate is increased,and the thickness of the step tread plate and riser plate is moderately reduced,so as to achieve the purpose of reducing the weight of the step and reducing the manufacturing cost and operating energy consumption.Through the finite element analysis and testing of the new type step design,Its strength and stiffness fully meet the requirements of GB 16899-2011 and EN 115-1:2017 standards,and the breaking force also meets the industry standards,so that the manufacturing and operating costs of the product can be reduced to improve the competitiveness of the product market. 展开更多
关键词 light aluminum step DEVELOPMENT finite element analysis
下载PDF
Finite element analysis of stress at implant-bone interface of dental implants with different structures 被引量:3
5
作者 陈良建 何浩 +3 位作者 李益民 李挺 郭小平 汪瑞芳 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第7期1602-1610,共9页
The effect of structure,elastic modulus and thickness of lower modulus layer in porous titanium implants on the stress distribution at the implant-bone interface was investigated.Three-dimensional finite element model... The effect of structure,elastic modulus and thickness of lower modulus layer in porous titanium implants on the stress distribution at the implant-bone interface was investigated.Three-dimensional finite element models of different titanium implants were constructed.The structures of the implants included the whole lower modulus style (No.1),bio-mimetic style (No.2),the whole lower modulus style in cancellous bone (No.3) and the whole dense style No.4.The stress distributions at bone-implant interface under static loading were analyzed using Ansys Workbench 10.0 software.The results indicated that the distribution of interface stress is strongly depended on the structure of the implants.The maximum stresses in cancellous bone and root region of implant No.2 are lower than those in the other three implants.A decrease in the modulus of the low modulus layer facilitates the interface stress transferring.Increasing the thickness of the low modulus layer can reduce the stress and induce a more uniform stress distribution at the interface.Among the four implants,biomimetic style implant No.2 is superior in transferring implant-bone interface stress to surrounding bones. 展开更多
关键词 titanium implant elastic modulus finite element analysis porous structure
下载PDF
Finite element analysis of the Taizhou Water Station Site 被引量:2
6
作者 潘建伍 淳庆 《Journal of Southeast University(English Edition)》 EI CAS 2013年第3期289-293,共5页
The Taizhou Water Station Site is an ancient masonry structure ruin built in the Southern Song Dynasty. The main structure was severely damaged. In order to understand its current structural properties and provide a s... The Taizhou Water Station Site is an ancient masonry structure ruin built in the Southern Song Dynasty. The main structure was severely damaged. In order to understand its current structural properties and provide a scientific basis for protection design nonlinear finite element analysis and parameter analysis are carried out.The crack patterns deformations and stresses of the main structure under four load cases are analyzed by nonlinear finite element analysis and the effect of the backfill bulk density and modulus on the maximum principal tensile stress and maximum compressive stress are studied by parameter analysis.The results show that the most unfavorable condition for the foundation is the combination of weight+backfill soil pressure+additional load the most unfavorable load case to the main structure is weight +backfill soil pressure +water pressure+additional heap load the maximum principal tensile stress of the main structure is very sensitive to the changes in the bulk density of the backfill soil. 展开更多
关键词 finite element analysis Taizhou Water StationSite ancient masonry structure
下载PDF
Modeling Technology in Finite Element Analysis of Electrostatic Proximity Fuze Problem 被引量:2
7
作者 李银林 施聚生 《Journal of Beijing Institute of Technology》 EI CAS 2000年第3期286-290,共5页
In order to analyze the electrostatic field concerned with electrostatic proximity fuze problem using the available finite analysis software package, the technology to model the problem with a scale reduction object a... In order to analyze the electrostatic field concerned with electrostatic proximity fuze problem using the available finite analysis software package, the technology to model the problem with a scale reduction object and boundary was presented. The boundary is determined by the maximum distance the sensor can detect. The object model is obtained by multiplying the terms in Poisson's equation with a scale reduction factor and the real value can be reconstructed with the same reverse process after software calculation. Using the finite element analysis program, the simulation value is close to the theoretical value with a little error. The boundary determination and scale reduction method is suitable to modeling the irregular electrostatic field around air targets, such as airplane, missile and so on, which is based on commonly used personal computer (PC). The technology reduces the calculation and storage cost greatly. 展开更多
关键词 electrostatic proximity fuze finite element analysis boundary condition scale reduction method
下载PDF
Seismic performance of double-skin steel-concrete composite box piers: Part Ⅱ—Nonlinear finite element analysis
8
作者 夏坚 宗周红 +1 位作者 徐焯然 李明鸿 《Journal of Southeast University(English Edition)》 EI CAS 2016年第3期346-355,共10页
An accurate finite element ( FE) model was constructed to examine the hysteretic behavior of double-skin steel-concrete composite box ( DSCB) piers for further understanding the seismic performance of DSCB piers;... An accurate finite element ( FE) model was constructed to examine the hysteretic behavior of double-skin steel-concrete composite box ( DSCB) piers for further understanding the seismic performance of DSCB piers; where the local buckling behavior of steel tubes, the confinement of the in-filled concrete and the interface action between steel tube and in-filled concrete were considered. The accuracy of the proposed FE model was verified by the bidirectional cyclic loading test results. Based on the validated FE model, the effects of some key parameters, such as section width to steel thickness ratio, slenderness ratio, aspect ratio and axial load ratio on the hysteretic behavior of DSCB piers were investigated. Finally, the skeleton curve model of DSCB piers was proposed. The numerical simulation results reveal that the peak strength and elastic stiffness decrease with the increase of the section width to steel thickness ratio. Moreover, the increase of the slenderness ratio may result in a significant reduction in the peak strength and elastic stiffness while the ultimate displacement increases. The proposed skeleton curve model can be taken as a reference for seismic performance analyses of the DSCB piers. 展开更多
关键词 double-skin steel-concrete composite box(DSCB) pier finite element analysis local buckling hysteretic behavior skeleton curve model
下载PDF
STIFFNESS ANALYSIS OF THE MAIN MODULE FOR PARALLEL MACHINE TOOLS BY FINITE ELEMENT ANALYSIS 被引量:2
9
作者 周立华 王玉茹 +1 位作者 黄田 Modler K H 《Transactions of Tianjin University》 EI CAS 2001年第1期30-35,共6页
With the aid of commercial finite element analysis software package ANSYS,investigations are made on the contributions of main components to stiffness of the main module for parallel machine tools,and it is found that... With the aid of commercial finite element analysis software package ANSYS,investigations are made on the contributions of main components to stiffness of the main module for parallel machine tools,and it is found that the frame is the main contributor.Then,influences of constraints,strut length and working ways of the main module have also been investigated.It can be concluded that when one of the main planes of the frame without linear drive unit is constrained,the largest whole stiffness can be acquired.And,the stiffness is much better when the main module is used in a vertical machine tool instead of a horizontal one.Finally,the principle of stiffness variation is summarized when the mobile platform reaches various positions within its working space and when various loads are applied.These achievements have provided critical instructions for the design of the main module for parallel machine tools. 展开更多
关键词 parallel machine tool main module STIFFNESS finite element analysis
全文增补中
Finite element analysis of stress distribution and burst failure of SiC_f/Ti-6Al-4V composite ring 被引量:2
10
作者 张红园 杨延清 罗贤 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2015年第1期261-270,共10页
A three-dimensional cyclic symmetry finite element model of titanium-matrix composites(TMCs) ring was developed to investigate the stress distribution and burst failure. The effects of fiber volume fractions, reinfo... A three-dimensional cyclic symmetry finite element model of titanium-matrix composites(TMCs) ring was developed to investigate the stress distribution and burst failure. The effects of fiber volume fractions, reinforced areas, thermal residual stresses and two different temperatures on stress distribution were studied. The burst speed was obtained through analyzing the hoop tensile stresses under a series of rotating speeds. The results indicate that at the two different temperatures, the influences of fiber volume fractions and reinforced areas on stress level and distribution are different. Some proposals are provided for the structure design of the TMCs ring. With regard to thermal residual stresses, a larger reinforced area is an advisable choice for design of the ring at higher temperature. 展开更多
关键词 titanium-matrix composites RING stress distribution burst failure finite element analysis thermal residual stresses
下载PDF
Three-dimensional Finite Element Analysis of the Mechanical Properties of Helical Thread Connection 被引量:19
11
作者 YANG Guoqing HONG Jun +3 位作者 ZHU Linbo LI Baotong XIONG Meihua WANG Fei 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2013年第3期564-572,共9页
Conventional analytical and numerical methods for the mechanical properties of helical threads are relied on many assumptions and approximations and thus hardly yield satisfied results. A parameterized 3D finite eleme... Conventional analytical and numerical methods for the mechanical properties of helical threads are relied on many assumptions and approximations and thus hardly yield satisfied results. A parameterized 3D finite element model of bolted joints with real helical thread geometry is established and meshed with refined hexahedral elements. The Von Mises plasticity criterion, kinematic hardening rule of materials and interfacial contacts are employed to make it possible for the suggested model be able to approach real assembly conditions. Then, the mechanical properties of bolted joints with different thread pitches, thread numbers and modular ratios are investigated, including the contact pressure distribution at joint interfaces, the axial load distribution and stress concentration in screw threads during the loading and unloading process. Simulation results indicate that the load distribution in screw threads produced by the suggested model agrees well the results from CHEN’s photoelastic tests. In addition, an interesting phenomenon is found that tightening the bolt with a large preload first and then adjusting the clamping force by unloading can make the load distribution more uniform and reduce the maximum residual equivalent stress in thread roots by up to 40%. This research provides a simple and practical approach to constructing the 3D finite element model and predicting the mechanical properties of helical thread connection. 展开更多
关键词 finite element analysis thread connection load distribution stress concentration
下载PDF
Finite element analysis of multi-piece post-crown restoration using different types of adhesives 被引量:8
12
作者 Lin-Wei L Guang-Wei Meng Zhi-Hui Liu 《International Journal of Oral Science》 SCIE CAS CSCD 2013年第3期162-166,共5页
The multi-piece post-crown technique is more effective in restoring residual root than other restoration techniques.Various types of adhesives have different material properties that affect restoration.Therefore,the c... The multi-piece post-crown technique is more effective in restoring residual root than other restoration techniques.Various types of adhesives have different material properties that affect restoration.Therefore,the choice of adhesive is particularly important for patients.However,the effect of different kinds of adhesives was not too precise by experimental methods when concerning about individual differences of teeth.One tooth root can only be restored with one type of adhesive in experiment.After the mechanical test,this tooth root cannot be restored with other adhesives.With the help of medical imaging technology,reverse engineering and finite element analysis,a molar model can be reconstructed precisely and restored using different types of adhesives.The same occlusal and chewing loads were exerted on the same restored residual root models with different types of adhesives separately.Results of von Mises stress analysis showed that the adhesives with low Young’s modulus can protect the root canal effectively.However,a root canal concentration is apparently produced around the root canal orifice when chewing.Adhesives with large Young’s modulus can buffer the stress concentration of the root canal orifice.However,the root canal tissue may be destroyed because the adhesive is too hard to buffer the load. 展开更多
关键词 ADHESIVE finite element analysis molar restoration multi-piece post-crown STOMATOLOGY
下载PDF
Influence of Various Materials on Biomechanical Behavior of Endocrown-Restored, Endodontically-Treated Mandibular First Molar: A 3D-Finite Element Analysis 被引量:10
13
作者 陈彬文 马彦昭 +5 位作者 WU Kunxue CHEN Hong LI Lu LIANG Liang LIU Jun 陈智 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2015年第3期643-648,共6页
To evaluate the effect of restorative materials on stress distribution of endodontically treated teeth, the 3D models of an endodontically treated mand^ular first molar, restoration, and cement layer were created. Thr... To evaluate the effect of restorative materials on stress distribution of endodontically treated teeth, the 3D models of an endodontically treated mand^ular first molar, restoration, and cement layer were created. Three different materials (composite resin, ceramage and ceramic) were studied and two loading conditions (vertical and oblique load) were simulated. Mohr-Coulomb failure criterion of enamel, dentine, endocrown and cement were evaluated separately. It is indicated that under both loading conditions, the highest values of Mohr-Coulomb failure criterion were observed in Ceramage-restored group for remaining tooth structure while in ceramic-restored group for the restoration. Compared to composite resin and Ceramage, ceramic endocrown transferred less stress, namely was more protective to the tooth structure. 展开更多
关键词 endocrown endodontically-treated teeth restorative material finite element analysis
下载PDF
Nonlinear Finite Element Analysis of Ocean Cables 被引量:9
14
作者 Nam-Il KIM Sang-Soo JEON Moon-Young KIM 《海洋工程:英文版》 2004年第4期537-550,共14页
This study has focused on developing numerical procedures for the dynamic nonlinear analysis of cable structures subjected to wave forces and ground motions in the ocean. A geometrically nonlinear finite element proce... This study has focused on developing numerical procedures for the dynamic nonlinear analysis of cable structures subjected to wave forces and ground motions in the ocean. A geometrically nonlinear finite element procedure using the isoparametric curved cable element based on the Lagrangian formulation is briefly summarized. A simple and accurate method to determine the initial equilibrium state of cable systems associated with self-weights, buoyancy and the motion of end points is presented using the load incremental method combined with penalty method. Also the Newmark method is used for dynamic nonlinear analysis of ocean cables. Numerical examples are presented to validate the present numerical method. 展开更多
关键词 NONLINEAR CABLE WAVE finite element analysis
下载PDF
Finite Element Analysis of 3-D Electromagnetic Field in Bloom Continuous Casting Mold 被引量:6
15
作者 LIU Xu-dong YANG Xiao-dong +2 位作者 ZHU Miao-yong CHEN Yong YANG Su-bo 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2007年第3期6-12,共7页
Three-dimensional finite element model of electromagnetic stirrer was built to predict magnetic field in a bloom continuous casting mold for steel during operation. The effects of current intensity, current frequency,... Three-dimensional finite element model of electromagnetic stirrer was built to predict magnetic field in a bloom continuous casting mold for steel during operation. The effects of current intensity, current frequency, and mold copper plate thickness on the magnetic field distribution in the mold were investigated. The results show that the magnetic induction intensity increases linearly with the increase in current intensity and decreases with the increase in current frequency. Increasing current intensity and frequency is available in increasing the electromagnetic force. The Joule heat decreases gradually from surface to center of bloom, and a maximum Joule heat can be found on corner of bloom. The prediction of magnetic induction intensity is in good agreement with the measured values. 展开更多
关键词 MOLD electromagnetic stirring finite element analysis numerical simulation
下载PDF
Structure,Orientation and Finite Element Analysis of the Tail Club of Mamenchisaurus hochuanensis 被引量:5
16
作者 XING Lida YE Yong +2 位作者 SHU Chunkang PENG Guangzhao YOU Hailu 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2009年第6期1031-1040,共10页
The structure and orientation of the posterior extremity (tail club) of the caudal vertebrae of Mamenchisaurus hochuanensis Young and Chao, 1972 from the Upper Jurassic Shangshaximiao Formation has been analyzed to ... The structure and orientation of the posterior extremity (tail club) of the caudal vertebrae of Mamenchisaurus hochuanensis Young and Chao, 1972 from the Upper Jurassic Shangshaximiao Formation has been analyzed to determine the tail club function using Finite Element Analysis. Of the four caudal vertebrae composing the tail club, the second largest (C"1") was probably the most proximal, and is fixed with the preceding sequence of the caudal vertebrae, whereas the smallest (C"4") is free and forms the termination of the tail club. Our analysis also suggests that the tail club is more efficient in lateral swinging rather than up-and-down motion, and that the best region for the tail club to impact is at the spine of the largest of the four caudals (C"2"), with a maximum load for impact at about 450 N. The tail club of Mamenchisaurus hochuanensis probably also had limitations as a defense weapon and was more possibly a sensory organ to improve nerve conduction velocity to enhance the capacity for sensory perception of its surroundings. 展开更多
关键词 Mamenchisaurus tail club finite element analysis Shangshaximiao Formation JURASSIC
下载PDF
Finite Element Analysis of the Contact Mechanics of Ceramic-on-Ceramic Hip Resurfacing Prostheses 被引量:4
17
作者 Ahmet C.Cilingir 《Journal of Bionic Engineering》 SCIE EI CSCD 2010年第3期244-253,共10页
Ceramics are good alternative to metal as bearing couple materials because of their better wear resistance. A Finite Element(FE) study was performed to investigate the contact mechanics and stress distribution of Cera... Ceramics are good alternative to metal as bearing couple materials because of their better wear resistance. A Finite Element(FE) study was performed to investigate the contact mechanics and stress distribution of Ceramic-on-Ceramic (COC) hip resurfacingprostheses. It was focused in particular on a parametric study to examine the effects of radial clearance, loading,alumina coating on the implants, bone quality, and fixation of cup-bone interface. It was found that a reduction in the radialclearance had the most significant effect on the predicted contact pressure distribution among all of the parameters considered inthis study. It was determined that there was a significant influence of non-metallic materials, such as the bone underneath thebearing components, on the predicted contact mechanics. Stress shielding within the bone tissue was found to be a major concernwhen regarding the use of ceramic as an alternative to metallic resurfacing prostheses. Therefore, using alumina implantswith a metal backing was found to be the best design for ceramic resurfacing prostheses in this study. The loading, bone quality,and acetabular cup fixation conditions were found to have only minor effects on the predicted contact pressure distribution alongthe bearing surfaces. 展开更多
关键词 contact mechanics HIP RESURFACING CERAMIC finite element analysis
下载PDF
3-D FINITE ELEMENT ANALYSIS OF THE EFFECT OF WELDING RESIDUAL STRESS ON HYDROGEN DIFFUSION IN HYDROGEN CONTAINED ENVIRONMENT 被引量:5
18
作者 W.C. Jiang J.M. Gong J.Q. Tang H. Chen S.T. Tu 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2007年第5期347-354,共8页
The hydrogen distribution of 16MnR steel weldment in hydrogen contained environment was calculated using the finite element method ( FEM). The effect of welding residual stress on hydrogen diffusion has been discuss... The hydrogen distribution of 16MnR steel weldment in hydrogen contained environment was calculated using the finite element method ( FEM). The effect of welding residual stress on hydrogen diffusion has been discussed using a 3-D sequential coupling finite element analysis procedure complied by Abaqus code. The hydrogen diffusion coefficient in weld metal, the heat affected zone (HAZ), and the base metal of the 16MnR steel weldment were measured using the electrochemical permeation technique. The hydrogen diffusion without the effect of stress was also calculated and compared. Owing to the existence of welding residual stress, the hydrogen concentration was obviously increased and the hydrogen wouM diffuse and accumulate in the higher stress region. 展开更多
关键词 16MnR steel hydrogen diffusion welding residual stress finite element analysis
下载PDF
Finite element analysis of stiffness and static dent resistance of aluminum alloy double-curved panel in viscous pressure forming 被引量:10
19
作者 LI Yi WANG Zhong-Jin 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2009年第S02期312-317,共6页
The static dent resistance performance of the aluminum alloy double-curved panel formed using viscous pressure forming (VPF)was studied by finite element analysis,which mainly considers the forming process conditions.... The static dent resistance performance of the aluminum alloy double-curved panel formed using viscous pressure forming (VPF)was studied by finite element analysis,which mainly considers the forming process conditions.The whole simulation consisting of three stages,i.e.,forming,spring-back and static dent resistance,was carried out continuously using the finite element code ANSYS.The influence of blank holder pressure(BHP)and the drawbead on the stiffness and the static dent resistance of the panels formed using VPF was analyzed.The results show that the adequate setting of the drawbead can increase the plastic deformation of the double-curved panel,which is beneficial to the initial stiffness and the static dent resistance.There is an optimum BHP range for the stiffness and the static dent resistance. 展开更多
关键词 aluminum alloy double-curved panel viscous pressure forming panel stiffness static dent resistance finite element analysis
下载PDF
Dynamic Adaptive Finite Element Analysis of Acoustic Wave Propagation Due to Underwater Explosion for Fluid-structure Interaction Problems 被引量:4
20
作者 Seyed Shahab Emamzadeh Mohammad Taghi Ahmadi +1 位作者 Soheil Mohammadi Masoud Biglarkhani 《Journal of Marine Science and Application》 CSCD 2015年第3期302-315,共14页
In this paper, an investigation into the propagation of far field explosion waves in water and their effects on nearby structures are carried out. For the far field structure, the motion of the fluid surrounding the s... In this paper, an investigation into the propagation of far field explosion waves in water and their effects on nearby structures are carried out. For the far field structure, the motion of the fluid surrounding the structure may be assumed small, allowing linearization of the governing fluid equations. A complete analysis of the problem must involve simultaneous solution of the dynamic response of the structure and the propagation of explosion wave in the surrounding fluid. In this study, a dynamic adaptive finite element procedure is proposed. Its application to the solution of a 2D fluid-structure interaction is investigated in the time domain. The research includes:a) calculation of the far-field scatter wave due to underwater explosion including solution of the time-depended acoustic wave equation, b) fluid-structure interaction analysis using coupled Euler-Lagrangian approach, and c) adaptive finite element procedures employing error estimates, and re-meshing. The temporal mesh adaptation is achieved by local regeneration of the grid using a time-dependent error indicator based on curvature of pressure function. As a result, the overall response is better predicted by a moving mesh than an equivalent uniform mesh. In addition, the cost of computation for large problems is reduced while the accuracy is improved. 展开更多
关键词 adaptive mesh fluid-structure interaction acoustic wave finite element analysis underwater explosion
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部