A three-dimensional computational fluid dynamics (CFD) model was developed to simulate a 150-t top-blown converter. The ef-fect of different lance heights on the cavity shape was investigated using the volume of flu...A three-dimensional computational fluid dynamics (CFD) model was developed to simulate a 150-t top-blown converter. The ef-fect of different lance heights on the cavity shape was investigated using the volume of fluid (VOF) method. Numerical simulation results can reflect the actual molten bath surface waves impinged by the supersonic oxygen jets. With increasing lance height, the cavity depth de-creases, and the cavity area, varying like a parabola, increases and then decreases. The cavity area maximizes at the lance height of 1.3 m. Under the three different lance heights simulated in this study, all of the largest impact velocities at the molten bath surface are between 50 m/s and 100 m/s.展开更多
文摘A three-dimensional computational fluid dynamics (CFD) model was developed to simulate a 150-t top-blown converter. The ef-fect of different lance heights on the cavity shape was investigated using the volume of fluid (VOF) method. Numerical simulation results can reflect the actual molten bath surface waves impinged by the supersonic oxygen jets. With increasing lance height, the cavity depth de-creases, and the cavity area, varying like a parabola, increases and then decreases. The cavity area maximizes at the lance height of 1.3 m. Under the three different lance heights simulated in this study, all of the largest impact velocities at the molten bath surface are between 50 m/s and 100 m/s.