New methodology of designing the differential pressure flow meters for fluid energy carriers is developed in order to provide minimum uncertainty of results of flow rate measurement. This methodology is implemented in...New methodology of designing the differential pressure flow meters for fluid energy carriers is developed in order to provide minimum uncertainty of results of flow rate measurement. This methodology is implemented in “Raskhod-RU” CAD system for computer aided design and calculation of differential pressure flow meters. “Raskhod-RU” CAD meets the requirements of new Standards implemented in CIS countries (GOST 8.586.1,2,3,4,5-2005) and provides accomplishment of the following tasks: verification of conditions (constraints) for application of the differential pressure method according to the requirements of new Standards;calculation of parameters of primary device, pipe straight lengths and flow meter in general according to the requirements of new Standards;calculation of uncertainty of results of fluid flow rate and volume measurement.展开更多
This paper advances the viewpoints and methods of the rapid sample product trial manufacture technique for developing water meter new products by CAD and simulation, computer virtual assembling and optimizing, rapid m...This paper advances the viewpoints and methods of the rapid sample product trial manufacture technique for developing water meter new products by CAD and simulation, computer virtual assembling and optimizing, rapid machining process and measurement etc. as the design and sample product trial manufacture process of water meter new products are long in product development period, and low in product development efficiency in the present time.展开更多
The design of a new type heat meters based on RFID technology are presented in this paper. By use of RFID technology in heat meters, the data can be exchanged between heat meters and heat supplying department by RF ca...The design of a new type heat meters based on RFID technology are presented in this paper. By use of RFID technology in heat meters, the data can be exchanged between heat meters and heat supplying department by RF cards. The information can be transmitted in a non-contact way. In this way, the purpose of automatic identification can be achieved. The experimental study of the heat meters is also performed in the paper. The results show that the new type of heat meters can meet the demands of users. Compared with the ordinary heat meters, the new type of heat meters have the advantages of small in meter volume, high accuracy, no impact of water quality and good reliability.展开更多
The monitoring of power consumption has become of a great interest in recent years as well as the innovative technologies available to realize Wireless Sensor Networks (WSNs) have experienced a great growth. While sma...The monitoring of power consumption has become of a great interest in recent years as well as the innovative technologies available to realize Wireless Sensor Networks (WSNs) have experienced a great growth. While smart metering technologies for electric energy are already established, as sensors power supply comes directly from power lines, WSN nodes for gas metering should necessarily be equipped with long life batteries. The presented work describes a new prototypal low cost WSN designed ad hoc for gas smart metering. The network has a star topology: each sensor node can be completely integrated with standard reed relay gas meter, and it is capable to measure the gas consumption. The information is sent to the central node (the Access Point, AP) through an RF links. The sensor nodes have been designed with custom electronics and a proprietary firmware, in order to work with a common 3.6 V lithium battery which is able to ensure a life period of about 10 years for each node. Only the AP must be connected directly to electric power. The AP is connected through the RS-232 interface to a control embedded PC equipped with a LAMP (Linux, Apache, MySQL, PHP) framework: it stores all the information coming from each node in a coherent database and allows authorized users to check the network status using a web interface. The WSN is self-learning and it is capable to detect new nodes joining the network without altering the normal operative flow. Moreover e-mail and SMS alerts can be activated to alert if a node is disconnected from the network or some problems occur. A first prototype of the WSN has been already tested achieving good results.展开更多
文摘New methodology of designing the differential pressure flow meters for fluid energy carriers is developed in order to provide minimum uncertainty of results of flow rate measurement. This methodology is implemented in “Raskhod-RU” CAD system for computer aided design and calculation of differential pressure flow meters. “Raskhod-RU” CAD meets the requirements of new Standards implemented in CIS countries (GOST 8.586.1,2,3,4,5-2005) and provides accomplishment of the following tasks: verification of conditions (constraints) for application of the differential pressure method according to the requirements of new Standards;calculation of parameters of primary device, pipe straight lengths and flow meter in general according to the requirements of new Standards;calculation of uncertainty of results of fluid flow rate and volume measurement.
文摘This paper advances the viewpoints and methods of the rapid sample product trial manufacture technique for developing water meter new products by CAD and simulation, computer virtual assembling and optimizing, rapid machining process and measurement etc. as the design and sample product trial manufacture process of water meter new products are long in product development period, and low in product development efficiency in the present time.
文摘The design of a new type heat meters based on RFID technology are presented in this paper. By use of RFID technology in heat meters, the data can be exchanged between heat meters and heat supplying department by RF cards. The information can be transmitted in a non-contact way. In this way, the purpose of automatic identification can be achieved. The experimental study of the heat meters is also performed in the paper. The results show that the new type of heat meters can meet the demands of users. Compared with the ordinary heat meters, the new type of heat meters have the advantages of small in meter volume, high accuracy, no impact of water quality and good reliability.
文摘The monitoring of power consumption has become of a great interest in recent years as well as the innovative technologies available to realize Wireless Sensor Networks (WSNs) have experienced a great growth. While smart metering technologies for electric energy are already established, as sensors power supply comes directly from power lines, WSN nodes for gas metering should necessarily be equipped with long life batteries. The presented work describes a new prototypal low cost WSN designed ad hoc for gas smart metering. The network has a star topology: each sensor node can be completely integrated with standard reed relay gas meter, and it is capable to measure the gas consumption. The information is sent to the central node (the Access Point, AP) through an RF links. The sensor nodes have been designed with custom electronics and a proprietary firmware, in order to work with a common 3.6 V lithium battery which is able to ensure a life period of about 10 years for each node. Only the AP must be connected directly to electric power. The AP is connected through the RS-232 interface to a control embedded PC equipped with a LAMP (Linux, Apache, MySQL, PHP) framework: it stores all the information coming from each node in a coherent database and allows authorized users to check the network status using a web interface. The WSN is self-learning and it is capable to detect new nodes joining the network without altering the normal operative flow. Moreover e-mail and SMS alerts can be activated to alert if a node is disconnected from the network or some problems occur. A first prototype of the WSN has been already tested achieving good results.