This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and ...This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and five simulated workplace fields with241Am-Be moderated sources).The calibration in standard fields with bare sources was conducted by following the recommendations of the ISO 8529 standard.The measured total neutron ambient dose equivalent rates,denoted as H*(10)tot,were analyzed to obtain direct components,denoted as H*(10)dir,using a reduced fitting method.The CF was then calculated as the ratio between the conventional true value of the neutron ambient dose equivalent rate in a free field,denoted as H*(10)FF,and the value of H*(10)dir.In contrast,in the simulated workplace neutron fields,the calibration of the neutron dose rate meter was conducted by following the ISO 12789 standard.The CF was calculated as the ratio between the values of H*(10)totmeasured by a standard instrument(i.e.,Bonner sphere spectrometer)and the neutron dose rate meter.The CF values were obtained in the range of 0.88–1.0.The standard uncertainties(k=1)of the CFs were determined to be in the range of approximately 6.6–13.1%.展开更多
基金by the National Foundation for Science and Technology Development of Vietnam(No.103.04-2017.37)。
文摘This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and five simulated workplace fields with241Am-Be moderated sources).The calibration in standard fields with bare sources was conducted by following the recommendations of the ISO 8529 standard.The measured total neutron ambient dose equivalent rates,denoted as H*(10)tot,were analyzed to obtain direct components,denoted as H*(10)dir,using a reduced fitting method.The CF was then calculated as the ratio between the conventional true value of the neutron ambient dose equivalent rate in a free field,denoted as H*(10)FF,and the value of H*(10)dir.In contrast,in the simulated workplace neutron fields,the calibration of the neutron dose rate meter was conducted by following the ISO 12789 standard.The CF was calculated as the ratio between the values of H*(10)totmeasured by a standard instrument(i.e.,Bonner sphere spectrometer)and the neutron dose rate meter.The CF values were obtained in the range of 0.88–1.0.The standard uncertainties(k=1)of the CFs were determined to be in the range of approximately 6.6–13.1%.