期刊文献+
共找到33篇文章
< 1 2 >
每页显示 20 50 100
Robustness Study and Superior Method Development and Validation for Analytical Assay Method of Atropine Sulfate in Pharmaceutical Ophthalmic Solution
1
作者 Md. Nazmus Sakib Chowdhury Sreekanta Nath Dalal +4 位作者 Md. Ariful Islam Md. Anwar Hossain Pranab Kumar Das Shakawat Hossain Parajit Das 《American Journal of Analytical Chemistry》 CAS 2024年第5期151-164,共14页
Background: The robustness is a measurement of an analytical chemical method and its ability to contain unaffected by little with deliberate variation of analytical chemical method parameters. The analytical chemical ... Background: The robustness is a measurement of an analytical chemical method and its ability to contain unaffected by little with deliberate variation of analytical chemical method parameters. The analytical chemical method variation parameters are based on pH variability of buffer solution of mobile phase, organic ratio composition changes, stationary phase (column) manufacture, brand name and lot number variation;flow rate variation and temperature variation of chromatographic system. The analytical chemical method for assay of Atropine Sulfate conducted for robustness evaluation. The typical variation considered for mobile phase organic ratio change, change of pH, change of temperature, change of flow rate, change of column etc. Purpose: The aim of this study is to develop a cost effective, short run time and robust analytical chemical method for the assay quantification of Atropine in Pharmaceutical Ophthalmic Solution. This will help to make analytical decisions quickly for research and development scientists as well as will help with quality control product release for patient consumption. This analytical method will help to meet the market demand through quick quality control test of Atropine Ophthalmic Solution and it is very easy for maintaining (GDP) good documentation practices within the shortest period of time. Method: HPLC method has been selected for developing superior method to Compendial method. Both the compendial HPLC method and developed HPLC method was run into the same HPLC system to prove the superiority of developed method. Sensitivity, precision, reproducibility, accuracy parameters were considered for superiority of method. Mobile phase ratio change, pH of buffer solution, change of stationary phase temperature, change of flow rate and change of column were taken into consideration for robustness study of the developed method. Results: The limit of quantitation (LOQ) of developed method was much low than the compendial method. The % RSD for the six sample assay of developed method was 0.4% where the % RSD of the compendial method was 1.2%. The reproducibility between two analysts was 100.4% for developed method on the contrary the compendial method was 98.4%. 展开更多
关键词 ROBUSTNESS Method validation HPLC Compendial Method Method Development GDP LOQ
下载PDF
Comparison of Crop Model Validation Methods 被引量:3
2
作者 CAO Hong-xin Jim Scott Hanan +11 位作者 LIU Yan LIU Yong-xia YUE Yan-bin ZHU Da-wei LU Jian- fei SUNJin-ying SHI Chun-lin GE Dao-kuo WEI Xiu-fang YAO An-qing TIAN Ping-ping BAO Tai-lin 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2012年第8期1274-1285,共12页
In this paper, the many indices used in validation of crop models, such as RMSE (root mean square errors), Sd (standard error of absolute difference), da (mean absolute difference), dap (ratio of da to the mean... In this paper, the many indices used in validation of crop models, such as RMSE (root mean square errors), Sd (standard error of absolute difference), da (mean absolute difference), dap (ratio of da to the mean observation), r (correlation), and R2 (determination coefficient), are compared for the same rice architectural parameter model, and their advantages and disadvantages are analyzed. A new index for validation of crop models, dap between the observed and the simulated values, is proposed, with dap〈5% as the suggested standard for precision of crop models. The different kinds of validation methods in crop models should be combined in the following aspects:(1) calculating da and dap; (2) calculating the RMSE or Sd; (3) calculating r and R2, at the same time, plotting 1:1 diagram. 展开更多
关键词 crop models validation methods COMPARISON
下载PDF
Solriamfetol impurities:Synthesis,characterization,and analytical method(UPLC-UV)validation
3
作者 Nafisah Al-Rifai Anas Alshishani +4 位作者 Fouad Darras Ola Taha Shereen Abu-Jalloud Lena Shaghlil Yousef Al-Ebini 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第4期403-411,共9页
Given that impurities may affect the quality and safety of drug products,impurity identification and profiling is an integral part of drug quality control and is particularly important for newly developed medications ... Given that impurities may affect the quality and safety of drug products,impurity identification and profiling is an integral part of drug quality control and is particularly important for newly developed medications such as solriamfetol,which is used to treat excessive daytime sleepiness.Although the highperformance liquid chromatography analysis of commercial solriamfetol has revealed the presence of several impurities,their synthesis,structure elucidation,and chromatographic determination have not been reported yet.To bridge this gap,we herein identified,synthesized,and isolated eight processrelated solriamfetol impurities,characterized them using spectroscopic and chromatographic techniques,and proposed plausible mechanisms of their formation.Moreover,we developed and validated a prompt impurity analysis method based on ultrahigh-performance liquid chromatography with UV detection,revealing that its selectivity,linearity,accuracy,precision,and quantitation limit meet the acceptance criteria of method validation stipulated by the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use.Thus,the developed method was concluded to be suitable for the routine analysis of solriamfetol substances. 展开更多
关键词 Solriamfetol Impurity analysis Impurity synthesis UPLC Method validation
下载PDF
Influence of in vitro Methods, Receptor Fluids on Percutaneous Absorption and Validation of a Novel in vitro Method
4
作者 YU XIAO-ZHONG JIN XI-PENG +3 位作者 YIN LEI SHEN GUANG-ZU LIN HUI-FEN AND WANG YI-LAN (Laboratory of Skin Physiotogy and Toxicology, School of Public Health,Shanghai Medical University, Shanghai 200032, China)Correspondent: Yu Xiao-Zhon, P.O. Box 206 Department 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 1994年第3期248-258,共11页
In vitro experiment using excised skin has been valuable for studying the mechanism of percutaneous absorption. Based on previously established static diffusion cell system in this laboratory, a novel model-peifused g... In vitro experiment using excised skin has been valuable for studying the mechanism of percutaneous absorption. Based on previously established static diffusion cell system in this laboratory, a novel model-peifused glass diffusion cell system is desboed. The results of initial comporative study on percutaneous absorption between glass perfused diffusion cell and static diffusion cell, ih vitro and in vivo permeation as well as factors affecting permeation with seven radiolabelled chemicals are presented. The results demonstrate that the peifused diffusion cell system, which used a perfusion nuid betow the suiface of skin to take up the materials which penetrated the skin, is more similar to physiologic condition,convenient and automatic than that of the static cell. It well predicts the in vivo percutaneous absorption if appropriate areptor fluid is chosen. The results also show that the selection of receptor fluid is critical for in vitro permeation of chemicals with different soubility 展开更多
关键词 Receptor Fluids on Percutaneous Absorption and validation of a Novel in vitro Method Influence of in vitro methods
下载PDF
Quantification of Structurally Alert Mutagenic Impurities in Meropenem Trihydrate Drug Substance by Liquid Chromatography with High Resolution Mass Spectrometer (LC-HRMS)
5
作者 Anwar Sulaiman K. Ramakrishna Reddy +1 位作者 Vundavilli Jagadeesh Kumar Hemant Kumar Sharma 《American Journal of Analytical Chemistry》 CAS 2024年第3期119-133,共15页
Potential mutagenic impurities in Active Pharmaceutical Ingredient, Meropenem Trihydrate were assessed and a novel analytical method for their quantification was developed and validated. This Liquid Chromatographic me... Potential mutagenic impurities in Active Pharmaceutical Ingredient, Meropenem Trihydrate were assessed and a novel analytical method for their quantification was developed and validated. This Liquid Chromatographic method using High Resolution Mass Spectrometer (LC-HRMS) technique is proved to be suitable for simultaneous quantification of all ten identified impurities with required specificity, sensitivity, resolution, precision, accuracy, and other method characteristics as per ICH Guidelines. The acceptable limit of less than 2.9 μg/g was considered for evaluations, based on drug substance dosage and duration of treatment. The method stands most sensitive with a Limit of Detection of 0.35 μg/g, considering the challenge full acceptance criteria as per current regulatory standards. 展开更多
关键词 Mutagenic Impurities LC-HRMS Meropenem Trihydrate Method validation
下载PDF
Experimental validation method of elastic thin rod model for simulating the motional cable harness
6
作者 王春生 刘检华 +1 位作者 宁汝新 陈涛 《Journal of Beijing Institute of Technology》 EI CAS 2012年第2期192-197,共6页
To analyze the spring disturbance torque caused by motionai cable harness in a stabilized platform, the Kirchhoff theory based cable harness model has been previously developed to dynamically simulate the motional cab... To analyze the spring disturbance torque caused by motionai cable harness in a stabilized platform, the Kirchhoff theory based cable harness model has been previously developed to dynamically simulate the motional cable harness. In this paper, this model was validated by comparing the simulation results with the experiment results ( both the spring force and the deformed profile of the motional cable harness). In the experiment, a special optical measuring instrument based on binocular vision was developed and the motion and deformation of cable harness were measured. A simpli- fied stabilized platform system was constructed, and the absolute value of spring disturbance force during the motion of this simplified frame was obtained by using a force gauge (0. 02 N precision). The physical parameters of experimental specimen were also measured. The experimental and simulated results showed good agreement. These results should be useful for better motional cable harness layout design and reliable evaluation of the spring disturbance torque. 展开更多
关键词 experimental validation method binocular vision motional cable simulation Kirchhoffrod
下载PDF
Oocyte vitrification:A local validation of the method
7
作者 Pierre Boyer Debbie Montjean +1 位作者 Pierre Tourame Marie-Josée Gervoise-Boyer 《Open Journal of Obstetrics and Gynecology》 2013年第5期6-10,共5页
Is there a really need to validate oocyte vitrification technique in an ART laboratory before establishing it in daily practice? Validation of micromanipulationbased technique, in this case oocyte vitrification, is es... Is there a really need to validate oocyte vitrification technique in an ART laboratory before establishing it in daily practice? Validation of micromanipulationbased technique, in this case oocyte vitrification, is essential prior to enlarging its use to routine practice. Oocyte vitrification is a new worldwide used technique and legal recently inFrance. This micromanipulation needs to be performed by a skilled and experienced embryologist and requires an internal assessment in each ART unit before any wide use. We designed a prospective study, from September 2011 to July 2012, using sibling oocytes from women who recovered more than 12 Metaphase II oocytes. A part of freshly recovered oocytes underwent immediate ICSI while the remaining oocytes were vitrified. 87 couples undergoing ICSI were selected based on number of mature oocytes available on the recovery day after denudation. A part of fresh MII oocytes were microinjected and the others were vitrified using an open system (Cryotop?). The major criterion of interest was the number of embryo transferred/ number of Metaphase II ratio for after ICSI on fresh oocytes (42/211) versus vitrified/warmed oocytes (51/204) (p > 0.05). Secondary studied criteria were survival rate (80.5% ± 26.3%), fertilization rate (68.9 ± 33.5) and finally, cumulative pregnancy rate obtained in this study is 40.2%. One of the benefits of such practice is the limitation of embryo freezing. However, the study design delays oocytes warming cycles, due to pregnancies triggered by the transfer of fresh derived oocyte embryos and to the priority to transfer all the frozen embryos before starting oocytes warming. Moreover, no data is available about children’ health. Oocyte vitrification represents not only a change in our daily practice to improve cumulative pregnancy rate but also a promising tool to develop egg banking and donation. Clinical Trials Registration number: 209 R02. 展开更多
关键词 OOCYTE CRYOPRESERVATION VITRIFICATION ICSI Sibling Oocyte Study Method validation Pregnancy Rate Quality
下载PDF
Comparative Analysis and Validation Methodologies of GC and HPLC for Analysis of Cholesterol in Meat Products
8
作者 Gisely Luzia Stroher Angela Claudia Rodrigues +4 位作者 Lucia Felicidade Dias Mayka Reghiany Pedrao Luana Nascimento de Paula Jesui Vergilio Visentainer Nilson Evelazio de Souza 《American Journal of Analytical Chemistry》 2012年第4期306-311,共6页
This study validated different extraction methodologies and compared the quantification of cholesterol by gas chromatography (GC) and high performance liquid chromatography (HPLC) in mg per 100 g of Italian-type salam... This study validated different extraction methodologies and compared the quantification of cholesterol by gas chromatography (GC) and high performance liquid chromatography (HPLC) in mg per 100 g of Italian-type salami and traditional bologna. The GC method used was direct saponification of the samples without derivatizations and the HPLC method was used to extract of the lipid samples. The GC limits of detection and quantification obtained for cholesterol were, respectively, 0.001 and 0.003 mg.g–1. The HPLC values were 0.005 mg.g–1 and 0.016 mg.g–1. The GC recovery rate was 97.10 ± 0.13 and that of HPLC was 93.33 ± 0.22. Comparison of the cholesterol quantity found using the two chromatographic techniques shows that both are capable of quantifying cholesterol in the foods. With regard to costs, analysis time, the cost/benefit relationship was better with gas chromatography than that obtained with high performance liquid chromatography. 展开更多
关键词 Cholesterol determination Gas chromatography Liquid chromatography Method validation Meat Products
下载PDF
Enantioseparation of Palonosetron Hydrochloride and Its Related Enantiomeric Impurities by Computer Simulation and Validation
9
作者 M.Vishnu Murthy C.Krishnaiah +4 位作者 Kodithyala Jyothirmayi Katkam Srinivas K.Mukkanti Ramesh Kumar Gautam Samanta 《American Journal of Analytical Chemistry》 2011年第4期437-446,共10页
A rapid, simple and single stereo selective high-performance liquid chromatographic (HPLC) method was developed and validated for enantiomers of palonosetron hydrochloride (PALO) and its process related chiral impurit... A rapid, simple and single stereo selective high-performance liquid chromatographic (HPLC) method was developed and validated for enantiomers of palonosetron hydrochloride (PALO) and its process related chiral impurities. A computer simulating software was used for the development of chiral method. The developed method was able to separate not only the enantiomers of palonosetron hydrochloride but also its process related chiral impurities within 12 min. The chromatographic separation was carried out by normal phase chromatography using a 3 μm column of cellulose based chiral stationary phase (Chiralcel-OD 250mm × 4.6mm) with a mobile phase comprised of n-hexane: ethanol: methanol: heptafluoro butyric acid: diethyl amine (70:15:15:0.05:0.1, v/v) at a flow rate of 1.0 mL/min. The effects of additive concentration as well as nature of polar organic modifier, flow rate, and temperature on enantioselectivity were investigated. The limit of detection (LOD) and limit of quantification (LOQ) of the palonosetron isomers and its related chiral impurities were found to be in the range 0.06-0.10 μg/mL and 0.14 - 0.24 μg/mL respectively. The method showed excellent linearity (R2 > 0.998) over a range of 0.14 to 1.125 μg/mL. The percentage recovery of the isomers in bulk drug samples ranged from 87.0 to 116.0. 展开更多
关键词 High Performance Liquid Chromatography Palonosetron Hydrochloride Chiral Impurities Drylab^(█) Software Method Development Method validation
下载PDF
Nurses’ movements within and between various paths when improving their communication skills—An evaluation of validation method training
10
作者 Mona Soderlund Agneta Cronqvist +2 位作者 Astrid Norberg Britt-Marie Ternestedt Gorel Hansebo 《Open Journal of Nursing》 2013年第2期265-273,共9页
Aims and objectives: To explore any changes in nurses’ skills at communicating with residents with dementia disease when using the validation method, as observed in one-to-one videotaped conversations. Background: Co... Aims and objectives: To explore any changes in nurses’ skills at communicating with residents with dementia disease when using the validation method, as observed in one-to-one videotaped conversations. Background: Communication difficulties due to cognitive impairment among residents with dementia disease may complicate care situations. Training can improve nurses’ communication skills and increase care quality. The validation method aims to facilitate communication with residents with dementia disease through empathic and confirmatory approaches. Evaluations of the validation method have primarily focused on the residents’ perspective, and reports on nurses’ experiences are sparse. Improved communication and relationships with residents after validation method training have been described previously. Videotaped data could provide additional information about these earlier results. Design: A descriptive qualitative design. Methods: Eight nurses participated in a year of validation method training, including videotaped conversations with eleven residents. Videotapes with at least five months between the first and last recording were analysed and compared qualitatively. Results: The analysis revealed an overall pattern: nurses’ movements within and between various paths when improving their communication skills. This was based on three sub-patterns: from controlling communication towards developing attentiveness in communication, from ambiguous communication towards developing coherence in communication, and from being open and attentive towards having a refined attuned communication. Conclusions: All nurses developed their communication skills during the programme, albeit to different degrees. The findings are in congruence with the experiences described by nurses, and so it is reasonable to believe that the programme helped to improve the nurses’ skills in communicating with residents with dementia disease. Relevance to clinical practice: A validation method training programme could give nurses the possibility to develop their skills in communicating with residents with dementia disease. 展开更多
关键词 Training Communication Skills Dementia Care validation Method Qualitative Analysis of Videotapes
下载PDF
Appraisal of Engineering Phases of a Mineral Asset: From Exploration to Mine Approval
11
作者 Edmundo Tulcanaza 《Journal of Minerals and Materials Characterization and Engineering》 CAS 2023年第3期69-79,共11页
It is well known that the most common methodology for evaluating a mineral asset is the NPV. Most of the mining companies employ this technique for evaluating the expected economic benefits provided by the exploration... It is well known that the most common methodology for evaluating a mineral asset is the NPV. Most of the mining companies employ this technique for evaluating the expected economic benefits provided by the exploration and exploitation of a mineral deposit. However, companies also wish to know how their assets are creating value through the several exploration and development phases. The purpose being to assess the progressive value of the mineral asset in agreement with the information and data cumulated through the different steps from exploration to project approval. This paper establishes the value of a copper mineral deposit through their successive phases from exploration to feasibility and approval using the options’ binomial nodes framework. Results are applied to two copper negotiations for method validation. 展开更多
关键词 Mine Value Exploration Phases Binomial Nodes Copper Deposits Method validation
下载PDF
Measurement uncertainty in pharmaceutical analysis and its application 被引量:8
12
作者 Marcus Augusto Lyrio Traple Alessandro Morais Saviano +1 位作者 Fabiane Lacerda Francisco Felipe Rebello Lourencon 《Journal of Pharmaceutical Analysis》 CAS 2014年第1期1-5,共5页
The measurement uncertainty provides complete information about an analytical result. This is very important because several decisions of compliance or non-compliance are based on analytical results in pharmaceutical ... The measurement uncertainty provides complete information about an analytical result. This is very important because several decisions of compliance or non-compliance are based on analytical results in pharmaceutical industries. The aim of this work was to evaluate and discuss the estimation of uncertainty in pharmaceutical analysis. The uncertainty is a useful tool in the assessment of compliance or non-compliance of in-process and final pharmaceutical products as well as in the assessment of pharmaceutical equivalence and stability study of drug products. 展开更多
关键词 Measurement uncertainty Method validation Pharmaceutical analysis Quality control
下载PDF
A rapid and sensitive liquid chromatography-tandem mass spectrometric assay for duloxetine in human plasma:Its pharmacokinetic application 被引量:3
13
作者 Ramakrishna Gajula Rambabu Maddela +2 位作者 Vasu Babu Ravi Jaswanth Kumar Inamadugu Nageswara Rao Pilli 《Journal of Pharmaceutical Analysis》 SCIE CAS 2013年第1期36-44,共9页
This paper describes a simple, rapid and sensitive liquid chromatography tandem mass spectrometry assay for the determination of duloxetine in human plasma. A duloxetine stable labeled isotope (duloxetine ds) was us... This paper describes a simple, rapid and sensitive liquid chromatography tandem mass spectrometry assay for the determination of duloxetine in human plasma. A duloxetine stable labeled isotope (duloxetine ds) was used as an internal standard. Analyte and the internal standard were extracted from 100 btL of human plasma via solid phase extraction technique using Oasis HLB cartridges. The chromatographic separation was achieved on a Cl8 column by using a mixture of acetonitrile 5 mM ammonium acetate buffer (83:17, v/v) as the mobile phase at a flow rate of 0.9 mL/min. The calibration curve obtained was linear (r2≥0.99) over the concentration range of 0.05 101 ng/mL. Multiple-reaction monitoring mode (MRM) was used for quantification of ion transitions at rn/z 298.3/154.1 and 303.3/159.1 for the drug and the internal standard, respectively. Method validation was performed as per FDA guidelines and the results met the acceptance criteria. A run time of 2.5 min for each sample made it possible to analyze more than 300 plasma samples per day. The proposed method was found to be applicable to clinical studies. 展开更多
关键词 Duloxetine in humanplasma Solid-phase extraction(SPE) Liquidchromatography-tandem mass spectro-metry Method validation Pharmacokinetic studies
下载PDF
Simultaneous quantitation of atorvastatin and its two active metabolites in human plasma by liquid chromatography/(–) electrospray tandem mass spectrometry 被引量:3
14
作者 Pankaj Partani S.Manaswita Verma +2 位作者 Sanjay Gurule Arshad Khuroo Tausif Monif 《Journal of Pharmaceutical Analysis》 SCIE CAS 2014年第1期26-36,共11页
A sensitive, accurate and selective liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for the simultaneous quantitation of atorvastatin (AT) and its equipotent hydroxyl m... A sensitive, accurate and selective liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for the simultaneous quantitation of atorvastatin (AT) and its equipotent hydroxyl metabolites, 2-hydroxy atorvastatin (2-AT) and 4-hydroxy atorvastatin (4-AT), in human plasma. Electrospray ionization (ESI) interface in negative ion mode was selected to improve the selectivity and the sensitivity required for this application. Additionally, a solid phase extraction (SPE) step was performed to reduce any ion-suppression and/or enhancement effects. The separation of all compounds was achieved in less than 6 min using a C18 reverse-phase fused-cores column and a mobile phase, composed of a mixture of 0.005%formic acid in water:acetonitrile:methanol (35:25:40, v/v/v), in isocratic mode at a flow rate of 0.6 mL/min. The method has lower limit of quantitation (LLOQ) of 0.050 ng/mL for all analytes. The method has shown tremendous reproducibility, with intra-and inter-day precision less than 6.6%, and intra- and inter-day accuracy within 74.3% of nominal values, for all analytes, and has proved to be highly reliable for the analysis of clinical samples. 展开更多
关键词 ATORVASTATIN LC-MS/MS Solid phase extractionPharmacokinetics Method validation
下载PDF
Development of an analytical method for multi-residue quantification of 18 anthelmintics in various animal-based food products using liquid chromatography-tandem mass spectrometry 被引量:1
15
作者 Kyung-Hee Yoo Da-Hee Park +8 位作者 A.M.Abd El-Aty Seong-Kwan Kim Hae-Ni Jung Da-Hye Jeong Hee-Jung Cho Ahmet Hacimuftuoglu Jae-Han Shim Ji Hoon Jeong Ho-Chul Shin 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2021年第1期68-76,共9页
In this study,we developed a simple screening procedure for the determination of 18 anthelmintics(including benzimidazoles,macrocyclic lactones,salicylanilides,substituted phenols,tetrahydropyrimidines,and imidazothia... In this study,we developed a simple screening procedure for the determination of 18 anthelmintics(including benzimidazoles,macrocyclic lactones,salicylanilides,substituted phenols,tetrahydropyrimidines,and imidazothiazoles)in five animal-derived food matrices(chicken muscle,pork,beef,milk,and egg)using liquid chromatography-tandem mass spectrometry.Analytes were extracted using acetonitrile/1% acetic acid(milk and egg)and acetonitrile/1% acetic acid with 0.5 mL of distilled water(chicken muscle,pork,and beef),and purified using saturated n-hexane/acetonitrile.A reversed-phase analytical column and a mobile phase consisting of(A)10 mM ammonium formate in distilled water and(B)methanol were used to achieve optimal chromatographic separation.Matrix-matched standard calibration curves(R^(2)≥0.9752)were obtained for concentration equivalent to ×1/2,×1,×2,×3,×4,and×5 fold the maximum residue limit(MRL)stipulated by the Korean Ministry of Food and Drug Safety.Recoveries of 61.2e118.4%,with relative standard deviations(RSDs)of ≤19.9%(intraday and interday),were obtained for each sample at three spiking concentrations(×1/2,×1,and ×2 the MRL values).Limits of detection,limits of quantification,and matrix effects were 0.02e5.5 mg/kg,0.06e10 mg/kg,and -98.8 to 13.9%(at 20 μg/kg),respectively.In five samples of each food matrix(chicken muscle,pork,beef,milk,and egg)purchased from large retailers in Seoul that were tested,none of the target analytes were detected.It has therefore been shown that this protocol is adaptable,accurate,and precise for the quantification of anthelmintic residues in foods of animal origin. 展开更多
关键词 ANTHELMINTICS Tandem mass spectrometry Animal-based food products Residue analysis Method validation
下载PDF
On the validity of the Boltzmann–BGK model through relaxation evaluation 被引量:2
16
作者 Quan-Hua Sun Chun-Pei Cai Wei Gao 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2014年第2期133-143,共11页
The Boltzmann-Bhatnagar-Gross-Krook(BGK)model is investigated for its validity regarding the collision term approximation through relaxation evaluation. The evaluation is based on theoretical analysis and numerical ... The Boltzmann-Bhatnagar-Gross-Krook(BGK)model is investigated for its validity regarding the collision term approximation through relaxation evaluation. The evaluation is based on theoretical analysis and numerical comparison between the BGK and direct simulation Monte Carlo(DSMC) results for three specifically designed relaxation problems. In these problems, one or half component of the velocity distribution is characterized by another Maxwellian distribution with a different temperature. It is analyzed that the relaxation time in the BGK model is unequal to the molecular mean collision time. Relaxation of component distribution fails to involve enough contribution from other component distributions, which makes the BGK model unable to capture details of velocity distribution, especially when discontinuity exists in distribution. The BGK model,however, predicts satisfactory results including fluxes during relaxation when the temperature difference is small. Particularly, the model-induced error in the BGK model increases with the temperature difference, thus the model is more reliable for low-speed rarefied flows than for hypersonic flows. 展开更多
关键词 BGK model Boltzmann equation Validity evaluation DSMC method Time relaxation
下载PDF
Optimization of Shanghai marine environment monitoring sites by integrating spatial correlation and stratified heterogeneity 被引量:2
17
作者 FAN Haimei GAO Bingbo +1 位作者 XU Ren WANG Jinfeng 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第2期111-121,共11页
The water quality grades of phosphate(PO4-P) and dissolved inorganic nitrogen(DIN) are integrated by spatial partitioning to fit the global and local semi-variograms of these nutrients. Leave-one-out cross validat... The water quality grades of phosphate(PO4-P) and dissolved inorganic nitrogen(DIN) are integrated by spatial partitioning to fit the global and local semi-variograms of these nutrients. Leave-one-out cross validation is used to determine the statistical inference method. To minimize absolute average errors and error mean squares,stratified Kriging(SK) interpolation is applied to DIN and ordinary Kriging(OK) interpolation is applied to PO4-P.Ten percent of the sites is adjusted by considering their impact on the change in deviations in DIN and PO4-P interpolation and the resultant effect on areas with different water quality grades. Thus, seven redundant historical sites are removed. Seven historical sites are distributed in areas with water quality poorer than Grade IV at the north and south branches of the Changjiang(Yangtze River) Estuary and at the coastal region north of the Hangzhou Bay. Numerous sites are installed in these regions. The contents of various elements in the waters are not remarkably changed, and the waters are mixed well. Seven sites that have been optimized and removed are set to water with quality Grades III and IV. Optimization and adjustment of unrestricted areas show that the optimized and adjusted sites are mainly distributed in regions where the water quality grade undergoes transition.Therefore, key sites for adjustment and optimization are located at the boundaries of areas with different water quality grades and seawater. 展开更多
关键词 area of water quality grade stratified Kriging(SK) leave-one-out cross validation method spatial simulated annealing method monitoring sites optimization
下载PDF
Enantiomeric Separation of S-Epichlorohydrin and R-Epichlorohydrin by Capillary Gas Chromatography with FID Detector 被引量:1
18
作者 Cholleti Vijay Kumar Pavan Kumar Vasa +2 位作者 Y. Ravindra Kumar Pasula Aparna Padi Pratyusha 《American Journal of Analytical Chemistry》 2016年第11期772-784,共13页
The aim of this study was to develop a simple and derivatization free method for the Quantification of S-Epichlorohydrin in R-Epichlorohydrin by using a gas chromatography coupled with flame ionization detector (FID).... The aim of this study was to develop a simple and derivatization free method for the Quantification of S-Epichlorohydrin in R-Epichlorohydrin by using a gas chromatography coupled with flame ionization detector (FID). Enantiopure epichlorohydrin was a valuable epoxide key starting material for preparing optically active Rivaroxaban. The enantiomeric separations of S-Epichlorohydrin and R-Epichlorohydrin were achieved on Gamaa-Dex-225 (30 meters × 0.25 mm I.D, 0.25 μm) column with a total run time of 30 min. Nitrogen was used as a carrier gas with constant pressure 25.0 psi. The critical experimental parameters such as, column selection, flow rate, injection volume and diluent were studied and optimized. Excellent correlation coeffient between peak responses and concentrations was >0.9998. The recoveries of S-Epichlorohydrin spiked in R-Epichlorohydrin were in the range from 98.2% to 102.8%. Limit of quantitation for S-Epichlorohydrin was sufficiently lower than limits specified by ICH. The method has validated as per International Conference on Harmonization (ICH) guidelines. A precise, accurate, linear and robust Gas Chromatography method was developed for the quantification of S-Epichlorohydrin in R-Epichlorohydrin for Rivaroxaban. 展开更多
关键词 S-Epichlorohydrin R-Epichlorohydrin Method Development ICH Guidelines Method validation Gas Chromatography
下载PDF
Stability Indicating HPLC Method for Quantification of Solifenacin Succinate &Tamsulosin Hydrochloride along with Its Impurities in Tablet Dosage Form 被引量:1
19
作者 Hari Kishan Reddy Ganthi Raveendra Reddy P +3 位作者 Young Jun Park Hanimi Reddy Bapatu So Jin Park Woo Hyong Cho 《American Journal of Analytical Chemistry》 2016年第11期840-862,共23页
A novel stability-indicating RP-HPLC method was developed and validated for simultaneous determination of Solifenacin Succinate & Tamsulosin Hydrochloride and its impurities in tablet dosage form. The method was d... A novel stability-indicating RP-HPLC method was developed and validated for simultaneous determination of Solifenacin Succinate & Tamsulosin Hydrochloride and its impurities in tablet dosage form. The method was developed using L1 column with gradient using the mobile phase consist of solvent-A (pH = 6.6, phosphate buffer + 0.5% Triethylamine) and solvent-B (90% Acetonitrile). The eluted compounds were monitored at 225 nm. Solifenacin Succinate & Tamsulosin Hydrochloride was subjected to oxidative, acid, base, hydrolytic, thermal and photolytic stress conditions. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantitation, accuracy, precision and robustness. The limit of quantification results was ranged from 0.135 - 0.221 μg/mL for Solifenacin Succinate impurities and 0.043 - 0.090 μg/mL for Tamsulosin Hydrochloride impurities. This method is suitable for the estimation of impurities and assay of Solifenacin Succinate & Tamsulosin Hydrochloride in tablets dosage form. 展开更多
关键词 SOLIFENACIN TAMSULOSIN RP-HPLC IMPURITIES Method validation
下载PDF
Systematical approach in evaluation of LC method for determination of raloxifene hydrochloride and its impurities employing experimental design
20
作者 B.Jani Stojanovi T.Raki +3 位作者 B.Slavkovi N.Kosti A.Vemi A.Malenovi 《Journal of Pharmaceutical Analysis》 SCIE CAS 2013年第1期45-52,共8页
Method validation presents a detailed investigation of analytical method and provision of the evidence that the method, when correctly applied, produces results that fit to the purpose. In order to achieve the method ... Method validation presents a detailed investigation of analytical method and provision of the evidence that the method, when correctly applied, produces results that fit to the purpose. In order to achieve the method validation scope efficiently, experimental design presents a very useful tool. The greatest benefits of such approach could be seen in robustness testing through the provision of very useful data about the control of the chromatograp6hic system during the routine application. In this paper, robustness testing of the LC method proposed for the determination of raloxifene hydrochloride and its four impurities was done employing Plackett-Burman design. Applying this design, the effect of five real factors (acetonitrile content, sodium dodecyl sulfate content, column temperature, pH of the mobile phase and flow rate) on the corresponding resolution factors was investigated through twelve experiments. Furthermore, the insignificance intervals for significant factors were calculated and the parameters for system suitability tests were defined. Eventually, the other validation parameters were tested and the effectiveness of the proposed analytical method with a high degree of accuracy was confirmed. 展开更多
关键词 Experimental design Method validation Raloxifenehydrochloride IMPURITIES Liquid chromatography
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部