This paper presents a study of the characteristics of a railway vibration at three key sections containing different track structures in a metro depot.The results show that the vertical and horizontal vibration accele...This paper presents a study of the characteristics of a railway vibration at three key sections containing different track structures in a metro depot.The results show that the vertical and horizontal vibration acceleration levels are proportional to train speed.The Z-weighted vertical acceleration levels obtained showed that the vibration source strengths at the ballast foot of the testing line and the throat area were very close.The vibration attenuation at the repair line was larger than that of the testing line.In the throat area,the peak frequency of vibration obtained at the ballast foot(2.5 m)could be shifted to a lower frequency band by using polyurethane sleepers instead of standard concrete sleepers.Polyurethane sleepers can help to reduce vertical vibration in a frequency band of 0-10 Hz.The vibration levels would satisfy the limits given in the ISO2631-2-2003(2013)for any location more than 5 m away from the source at the testing line and 2.5 m away from the source at the repair line and throat area.展开更多
基金National Natural Science Foundation of China under Grant Nos.52068029,51878277 and 52178423the Major Discipline Academic and Technical Leaders Training Program of Jiangxi Province Youth under Grant No.20194BCJ22008the Key Research and Development Program of Jiangxi Province under Grant No.20192BBE50008。
文摘This paper presents a study of the characteristics of a railway vibration at three key sections containing different track structures in a metro depot.The results show that the vertical and horizontal vibration acceleration levels are proportional to train speed.The Z-weighted vertical acceleration levels obtained showed that the vibration source strengths at the ballast foot of the testing line and the throat area were very close.The vibration attenuation at the repair line was larger than that of the testing line.In the throat area,the peak frequency of vibration obtained at the ballast foot(2.5 m)could be shifted to a lower frequency band by using polyurethane sleepers instead of standard concrete sleepers.Polyurethane sleepers can help to reduce vertical vibration in a frequency band of 0-10 Hz.The vibration levels would satisfy the limits given in the ISO2631-2-2003(2013)for any location more than 5 m away from the source at the testing line and 2.5 m away from the source at the repair line and throat area.