期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Micro/nano-fiber-based source of heralded single photons at the telecom band 被引量:1
1
作者 Jie Su Liang Cui +1 位作者 Yuhang Li Xiaoying Li 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第4期86-89,共4页
We experimentally demonstrate a heralded single photon source at 1290 nm by exploiting the spontaneous four wave mixing in a taper-drawn micro/nano-fiber(MNF). Because the frequency detuning between the pump and her... We experimentally demonstrate a heralded single photon source at 1290 nm by exploiting the spontaneous four wave mixing in a taper-drawn micro/nano-fiber(MNF). Because the frequency detuning between the pump and heralded single photons is ~58 THz, the contamination by Raman scattering is significantly reduced at room temperature. Since the MNF is naturally connected to standard single mode fibers via fiber tapers, the source would be compatible with the existing fiber networks. When the emission rate of heralded signal photons is about 4.6 kHz, the measured second-order intensity correlation function g(2)(0) is 0.017 ± 0.002, which is suppressed by a factor of more than 55, relative to the classical limit. 展开更多
关键词 micro/nano-fiber-based source of heralded single photons at the telecom band MNF SPD
原文传递
Micro EEG/ECG signal's chopper-stabilization amplifying chip for novel drycontact electrode 被引量:1
2
作者 Jianhui Sun Chunxing Wang +8 位作者 Gongtang Wang Jinhui Wang Qing Hua Chuanfu Cheng Xinxia Cai Tao Yin Yang Yu Haigang Yang Dengwang Li 《Journal of Semiconductors》 EI CAS CSCD 2017年第2期96-104,共9页
Facing the body's EEG(electroencephalograph, 0.5–100 Hz, 5–100 μV) and ECG's(electrocardiogram,〈 100 Hz, 0.01–5 mV) micro signal detection requirement, this paper develops a pervasive application micro sign... Facing the body's EEG(electroencephalograph, 0.5–100 Hz, 5–100 μV) and ECG's(electrocardiogram,〈 100 Hz, 0.01–5 mV) micro signal detection requirement, this paper develops a pervasive application micro signal detection ASIC chip with the chopping modulation/demodulation method. The chopper-stabilization circuit with the RRL(ripple reduction loop) circuit is to suppress the ripple voltage, which locates at the single-stage amplifier's outputting terminal. The single-stage chopping core's noise has been suppressed too, and it is beneficial for suppressing noises of post-circuit. The chopping core circuit uses the PFB(positive feedback loop) to increase the inputting resistance, and the NFB(negative feedback loop) to stabilize the 40 dB intermediate frequency gain. The cascaded switch-capacitor sample/hold circuit has been used for deleting spike noises caused by non-ideal MOS switches, and the VGA/BPF(voltage gain amplifier/band pass filter) circuit is used to tune the chopper system's gain/bandwidth digitally. Assisted with the designed novel dry-electrode, the real test result of the chopping amplifying circuit gives some critical parameters: 8.1 μW/channel, 0.8 μVrms(@band-widthD100 Hz), 4216–11220 times digitally tuning gain range, etc. The data capture system uses the NI CO's data capturing DAQmx interface,and the captured micro EEG/ECG's waves are real-time displayed with the PC-Labview. The proposed chopper system is a unified EEG/ECG signal's detection instrument and has a critical real application value. 展开更多
关键词 EEG/ECG novel dry-contact electrode weak and micro signal detection chopping modulation/demodulation de-noising gain/band width digitally tuning
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部