Cone-beam computed tomography(CBCT) is mostly used for position verification during the treatment process. However,severe image artifacts in CBCT hinder its direct use in dose calculation and adaptive radiation therap...Cone-beam computed tomography(CBCT) is mostly used for position verification during the treatment process. However,severe image artifacts in CBCT hinder its direct use in dose calculation and adaptive radiation therapy re-planning for proton therapy. In this study, an improved U-Net neural network named CBAM-U-Net was proposed for CBCT noise reduction in proton therapy, which is a CBCT denoised U-Net network with convolutional block attention modules. The datasets contained 20 groups of head and neck images. The CT images were registered to CBCT images as ground truth. The original CBCT denoised U-Net network, sCTU-Net, was trained for model performance comparison. The synthetic CT(SCT) images generated by CBAM-U-Net and the original sCTU-Net are called CBAM-SCT and U-Net-SCT images, respectively. The HU accuracies of the CT, CBCT, and SCT images were compared using four metrics: mean absolute error(MAE), root mean square error(RMSE), peak signal-to-noise ratio(PSNR), and structure similarity index measure(SSIM). The mean values of the MAE, RMSE, PSNR, and SSIM of CBAM-SCT images were 23.80 HU, 64.63 HU, 52.27 dB, and 0.9919, respectively,which were superior to those of the U-Net-SCT images. To evaluate dosimetric accuracy, the range accuracy was compared for a single-energy proton beam. The γ-index pass rates of a 4 cm × 4 cm scanned field and simple plan were calculated to compare the effects of the noise reduction capabilities of the original U-Net and CBAM-U-Net on the dose calculation results. CBAM-U-Net reduced noise more effectively than sCTU-Net, particularly in high-density tissues. We proposed a CBAM-U-Net model for CBCT noise reduction in proton therapy. Owing to the excellent noise reduction capabilities of CBAM-U-Net, the proposed model provided relatively explicit information regarding patient tissues. Moreover, it maybe be used in dose calculation and adaptive treatment planning in the future.展开更多
目的采用微焦点断层扫描(Micro-CT)评价超声骨焊接技术应用过程中超声震荡产热作用下PDLLA材料对骨愈合性能的影响。方法选择SPF级雄性新西兰大白兔36只,随机分为超声骨焊接技术辅助PDLLA材料组(A组)、拧入技术辅助PDLLA材料组(B组)、...目的采用微焦点断层扫描(Micro-CT)评价超声骨焊接技术应用过程中超声震荡产热作用下PDLLA材料对骨愈合性能的影响。方法选择SPF级雄性新西兰大白兔36只,随机分为超声骨焊接技术辅助PDLLA材料组(A组)、拧入技术辅助PDLLA材料组(B组)、假手术组(C组)、空白对照组(D组),各9只。于术后4、8、12周取下颌骨标本,周围骨组织进行HE染色,观察各组植入钉周围情况。对术后4、8、12周的下颌骨大体标本拍摄Micro-CT图,使用VG Studio MAX软件进行三维重建,摆正数据样本,即颌骨颊侧造模处为轴向,动态分析植入钉体积、植入钉周围200μm环状区及骨缺损处的植入材料体积数、相对骨体积分数(BV/TV)、骨小梁厚度(Tb.Th)、骨小梁数(Tb.N)、骨小梁间隙(Tb.Sp)等骨愈合相关指标。结果HE染色结果显示,按3个时间可动态观察到A、B、C组骨缺损处骨性骨痂替代纤维性骨痂,形成类骨质,编织骨的过程符合正常骨损伤愈合的过程。Micro-CT结果显示,A、B组术后3个时间点的材料体积比较差异均无统计学意义(P>0.05);在3个时间点,4组植入钉周围200μm环状区中BV/TV、Tb.Th、Tb.N、Tb.Sp比较差异均无统计学意义(P>0.05);在骨缺损处,A、B、C组三个时间点BV/TV、Tb.Th、Tb.N、Tb.Sp比较差异无统计学意义(P>0.05);术后4周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.N、Tb.Sp差异有统计学意义(P<0.05);与C组比较,A、B组Tb.N差异有统计学意义(P<0.01)。术后8周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.N、Tb.Sp差异有统计学意义(P<0.05);术后12周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.Sp差异有统计学意义(P<0.05)。结论超声骨焊接技术其超声震荡产热作用下PDLLA材料对骨愈合性能无不良影响。展开更多
Utilizing lightweight Al alloys in various industrial applications requires achieving precise pressure tightness and leak requirements.Vacuum pressure impregnation(VPI)with thermosetting polymers is commonly used to a...Utilizing lightweight Al alloys in various industrial applications requires achieving precise pressure tightness and leak requirements.Vacuum pressure impregnation(VPI)with thermosetting polymers is commonly used to address leakage defects in die-cast Al alloys.In this study,the efficacy of the VPI technique in sealing alloy parts was investigated using a combination of nondestructive micro X-ray computed tomography(micro XCT)and a standard leak test.The results demonstrate that the commonly used water leak test is insufficient for determining the sealing performance.Instead,micro XCT shows distinct advantages by enabling more comprehensive analysis.It reveals the presence of a low atomic number impregnates sealant within casting defects,which has low grey contrast and allows for visualizing primary leakage paths in 3D.The effective atomic number of impregnated resin is 6.75 and that of Al alloy is 13.69 by dual-energy X-ray CT.This research findings will contribute to enhancing the standard VPI process parameters and the properties of impregnating sealants to improve quality assurance for impregnation in industrial metals.展开更多
基金Digital Medical Equipment Research and Development Project,Ministry of Science and Technology,China:The development of Synchrotron-based proton therapy system(2016YFC0105400).
文摘Cone-beam computed tomography(CBCT) is mostly used for position verification during the treatment process. However,severe image artifacts in CBCT hinder its direct use in dose calculation and adaptive radiation therapy re-planning for proton therapy. In this study, an improved U-Net neural network named CBAM-U-Net was proposed for CBCT noise reduction in proton therapy, which is a CBCT denoised U-Net network with convolutional block attention modules. The datasets contained 20 groups of head and neck images. The CT images were registered to CBCT images as ground truth. The original CBCT denoised U-Net network, sCTU-Net, was trained for model performance comparison. The synthetic CT(SCT) images generated by CBAM-U-Net and the original sCTU-Net are called CBAM-SCT and U-Net-SCT images, respectively. The HU accuracies of the CT, CBCT, and SCT images were compared using four metrics: mean absolute error(MAE), root mean square error(RMSE), peak signal-to-noise ratio(PSNR), and structure similarity index measure(SSIM). The mean values of the MAE, RMSE, PSNR, and SSIM of CBAM-SCT images were 23.80 HU, 64.63 HU, 52.27 dB, and 0.9919, respectively,which were superior to those of the U-Net-SCT images. To evaluate dosimetric accuracy, the range accuracy was compared for a single-energy proton beam. The γ-index pass rates of a 4 cm × 4 cm scanned field and simple plan were calculated to compare the effects of the noise reduction capabilities of the original U-Net and CBAM-U-Net on the dose calculation results. CBAM-U-Net reduced noise more effectively than sCTU-Net, particularly in high-density tissues. We proposed a CBAM-U-Net model for CBCT noise reduction in proton therapy. Owing to the excellent noise reduction capabilities of CBAM-U-Net, the proposed model provided relatively explicit information regarding patient tissues. Moreover, it maybe be used in dose calculation and adaptive treatment planning in the future.
文摘目的采用微焦点断层扫描(Micro-CT)评价超声骨焊接技术应用过程中超声震荡产热作用下PDLLA材料对骨愈合性能的影响。方法选择SPF级雄性新西兰大白兔36只,随机分为超声骨焊接技术辅助PDLLA材料组(A组)、拧入技术辅助PDLLA材料组(B组)、假手术组(C组)、空白对照组(D组),各9只。于术后4、8、12周取下颌骨标本,周围骨组织进行HE染色,观察各组植入钉周围情况。对术后4、8、12周的下颌骨大体标本拍摄Micro-CT图,使用VG Studio MAX软件进行三维重建,摆正数据样本,即颌骨颊侧造模处为轴向,动态分析植入钉体积、植入钉周围200μm环状区及骨缺损处的植入材料体积数、相对骨体积分数(BV/TV)、骨小梁厚度(Tb.Th)、骨小梁数(Tb.N)、骨小梁间隙(Tb.Sp)等骨愈合相关指标。结果HE染色结果显示,按3个时间可动态观察到A、B、C组骨缺损处骨性骨痂替代纤维性骨痂,形成类骨质,编织骨的过程符合正常骨损伤愈合的过程。Micro-CT结果显示,A、B组术后3个时间点的材料体积比较差异均无统计学意义(P>0.05);在3个时间点,4组植入钉周围200μm环状区中BV/TV、Tb.Th、Tb.N、Tb.Sp比较差异均无统计学意义(P>0.05);在骨缺损处,A、B、C组三个时间点BV/TV、Tb.Th、Tb.N、Tb.Sp比较差异无统计学意义(P>0.05);术后4周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.N、Tb.Sp差异有统计学意义(P<0.05);与C组比较,A、B组Tb.N差异有统计学意义(P<0.01)。术后8周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.N、Tb.Sp差异有统计学意义(P<0.05);术后12周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.Sp差异有统计学意义(P<0.05)。结论超声骨焊接技术其超声震荡产热作用下PDLLA材料对骨愈合性能无不良影响。
文摘Utilizing lightweight Al alloys in various industrial applications requires achieving precise pressure tightness and leak requirements.Vacuum pressure impregnation(VPI)with thermosetting polymers is commonly used to address leakage defects in die-cast Al alloys.In this study,the efficacy of the VPI technique in sealing alloy parts was investigated using a combination of nondestructive micro X-ray computed tomography(micro XCT)and a standard leak test.The results demonstrate that the commonly used water leak test is insufficient for determining the sealing performance.Instead,micro XCT shows distinct advantages by enabling more comprehensive analysis.It reveals the presence of a low atomic number impregnates sealant within casting defects,which has low grey contrast and allows for visualizing primary leakage paths in 3D.The effective atomic number of impregnated resin is 6.75 and that of Al alloy is 13.69 by dual-energy X-ray CT.This research findings will contribute to enhancing the standard VPI process parameters and the properties of impregnating sealants to improve quality assurance for impregnation in industrial metals.