This study describes the details of how to construct a three-dimensional (3D) finite element model of a maxillary first premolar tooth based on micro-CT data acquisition technique, MIMICS soft- ware and ANSYS softwa...This study describes the details of how to construct a three-dimensional (3D) finite element model of a maxillary first premolar tooth based on micro-CT data acquisition technique, MIMICS soft- ware and ANSYS software. The tooth was scanned by micro-CT, in which 1295 slices were obtained and then 648 slices were selected for modeling. The 3D surface mesh models of enamel and dentin were created by MIMICS (STL file). The solid mesh model was constructed by ANSYS. After the material properties and boundary conditions were set, a loading analysis was performed to demonstrate the ap- plicableness of the resulting model. The first and third principal stresses were then evaluated. The re- suits showed that the number of nodes and elements of the finite element model were 56 618 and 311801, respectively. The geometric form of the model was highly consistent with that of the true tooth, and the deviation between them was ~).28%. The loading analysis revealed the typical stress patterns in the contour map. The maximum compressive stress existed in the contact points and the maximum tensile stress existed in the deep fissure between the two cusps. It is concluded that by using the micro-CT and highly integrated software, construction of the 3D finite element model with high quality will not be difficult for clinical researchers.展开更多
The purpose of this study was to show the benefit of visualizing a tree-dimensional (3D) image of the tongue’s muscle structure, which until now has been regarded as fully understood. Until now, no suitable 3D observ...The purpose of this study was to show the benefit of visualizing a tree-dimensional (3D) image of the tongue’s muscle structure, which until now has been regarded as fully understood. Until now, no suitable 3D observation methods have been developed for soft tissue, such as the tongue, using?histological magnification. For this purpose, this study used a micro-computed tomographic method (micro-CT) and image processing after the fixation, decalcification, and dehydration of a mouse tongue. Results: 3D rendered images of tongue muscles obtained by micro-CT showed every muscle and their relationships to each other. The superior longitudinal and the hyoglossus muscles of the tongue made up one group, while the inferior longitudinal and the styloglossus muscles of the tongue made up another. The boundary of the two muscles in each group was difficult to distinguish. On the other hand, what appear to be newly described muscles were identified. These results indicate that our micro-CT method is beneficial and that classical knowledge of tongue muscles derived from two-dimensional (2D) images does not fully describe the actual complexity of the tongue muscles. In our opinion, 3D rendered images mixed with raw structure can provide a more in-depth picture of the tongue from an integrated as well as an analytical perspective.展开更多
Thirty adult upper extremities were used to study the arteries of the hand byangiography,cross-sectional dissection and three-dimensional reconstruction withmicrocomputer.The arterial skeleton of the palm was composed...Thirty adult upper extremities were used to study the arteries of the hand byangiography,cross-sectional dissection and three-dimensional reconstruction withmicrocomputer.The arterial skeleton of the palm was composed of superficial,deep anddorsal planes.There were three main anastomotic pathways between the radial and ulnararteries or their branches in the radio-ulnar direction,while in the palmar dorsal dirce-tion there were three anastomotic zones between the palrnar and dorsal arterial plancs.The branches of the deep palmar arch radiated distally,proximally,palmarly anddorsally,so that the arch acted as the center of the arterial network of the hand.Thetransverse arterial allocations in the carpo-metacarpal segment of the palm were four intypes,but in the mid-palmar and metacarpo-phalangcal segments were three only.Accord-ing to the sources,cross-sectional area,irrigation territories and anastomoses of the ar-teries in each segment,the clinical significance in the rcplantation of the amputatcd palmshas been展开更多
The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical ...The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical devices,3D-XRF analysis with a micro confocal volume will create a great potential for 2D and 3D microstructural analysis and accurate quantitative analysis.However,the classic measurement method of scanning metal foils of a certain thickness leads to inaccuracy.A method for calibrating the confocal volume is proposed in this paper.The new method is based on the basic content of the textbook,and the theoretical results and the feasibility are given in detail for the 3D-XRF mono-chromatic x-ray condition and the poly-chromatic x-ray condition.We obtain a set of experimental confirmation using the poly-chromatic x-ray tube in the laboratory.It is proved that the sensitivity factor of the 3D-XRF can be directly and accurately obtained in a real calibration process.展开更多
Background: The suitability of micro-computed tomography (CT) for soft tissue applications has been well documented. Although the application of micro-CT to the three dimensional (3D) structure of the tongue muscle ha...Background: The suitability of micro-computed tomography (CT) for soft tissue applications has been well documented. Although the application of micro-CT to the three dimensional (3D) structure of the tongue muscle has been reported, a 3D rendering and/or a schematic view of the tongue muscle has yet to be published. Material and Method: First, muse tongues were fixed and decalcified, and then the vertical muscle (Ve), the transverse muscle (Tr), and/or the genioglossus muscle of the mouse tongue (Ge) were analyzed using micro-CT and are shown in this report in rendered images and pattern diagrams. Results: 1) The Tr is classified into three parts: the first part extends from the middle to the apical part of the tongue;the second part is strongly connected to the superior longitudinal muscles of the tongue (Lo);the third part fans out from the middle to the root of the tongue. 2) The Ve is classified into two main groups: the first group joins the dorsal and the lateral parts of the tongue;the second group joins the dorsal part and the floor of the tongue. 3) Ge is classified into four parts: three parts comprise the Ge apical and middle parts of the tongue, with one part in the inferior longitudinal muscles of the tongue, one joining the lingual septum of the tongue (LS), and the other joining the sub-surface of the dorsal part of the Lo. The remaining Ge exits in a fan-like manner through the root of the tongue and then joins the Tr.展开更多
The most common methods for three-dimensional reconstruction of peripheral nerve fascicles include histological and radiology techniques. Histological techniques have many drawbacks including an enormous manual worklo...The most common methods for three-dimensional reconstruction of peripheral nerve fascicles include histological and radiology techniques. Histological techniques have many drawbacks including an enormous manual workload and poor image registration. Micro-magnetic resonance imaging(Micro-MRI), an emerging radiology technique, has been used to report results in the brain, liver and tumor tissues. However, micro-MRI usage for obtaining intraneural structures has not been reported. The aim of this study was to present a new imaging method for three-dimensional reconstruction of peripheral nerve fascicles by ~1T micro-MRI. Freshly harvested sciatic nerve samples from an amputated limb were divided into four groups. Two different scanning conditions(Mannerist Solution/GD-DTPA contrast agent, distilled water) were selected, and both T1 and T2 phases programmed for each scanning condition. Three clinical surgeons evaluated the quality of the images via a standardized scale. Moreover, to analyze deformation of the two-dimensional image, the nerve diameter and total area of the micro-MRI images were compared after hematoxylin-eosin staining. The results show that rapid micro-MRI imaging method can be used for three-dimensional reconstruction of the fascicle structure. Nerve sample immersed in contrast agent(Mannerist Solution/GD-DTPA) and scanned in the T1 phase was the best. Moreover, the nerve sample was scanned freshly and can be recycled for other procedures. MRI images show better stability and smaller deformation compared with histological images. In conclusion, micro-MRI provides a feasible and rapid method for three-dimensional reconstruction of peripheral nerve fascicles, which can clearly show the internal structure of the peripheral nerve.展开更多
文摘This study describes the details of how to construct a three-dimensional (3D) finite element model of a maxillary first premolar tooth based on micro-CT data acquisition technique, MIMICS soft- ware and ANSYS software. The tooth was scanned by micro-CT, in which 1295 slices were obtained and then 648 slices were selected for modeling. The 3D surface mesh models of enamel and dentin were created by MIMICS (STL file). The solid mesh model was constructed by ANSYS. After the material properties and boundary conditions were set, a loading analysis was performed to demonstrate the ap- plicableness of the resulting model. The first and third principal stresses were then evaluated. The re- suits showed that the number of nodes and elements of the finite element model were 56 618 and 311801, respectively. The geometric form of the model was highly consistent with that of the true tooth, and the deviation between them was ~).28%. The loading analysis revealed the typical stress patterns in the contour map. The maximum compressive stress existed in the contact points and the maximum tensile stress existed in the deep fissure between the two cusps. It is concluded that by using the micro-CT and highly integrated software, construction of the 3D finite element model with high quality will not be difficult for clinical researchers.
文摘The purpose of this study was to show the benefit of visualizing a tree-dimensional (3D) image of the tongue’s muscle structure, which until now has been regarded as fully understood. Until now, no suitable 3D observation methods have been developed for soft tissue, such as the tongue, using?histological magnification. For this purpose, this study used a micro-computed tomographic method (micro-CT) and image processing after the fixation, decalcification, and dehydration of a mouse tongue. Results: 3D rendered images of tongue muscles obtained by micro-CT showed every muscle and their relationships to each other. The superior longitudinal and the hyoglossus muscles of the tongue made up one group, while the inferior longitudinal and the styloglossus muscles of the tongue made up another. The boundary of the two muscles in each group was difficult to distinguish. On the other hand, what appear to be newly described muscles were identified. These results indicate that our micro-CT method is beneficial and that classical knowledge of tongue muscles derived from two-dimensional (2D) images does not fully describe the actual complexity of the tongue muscles. In our opinion, 3D rendered images mixed with raw structure can provide a more in-depth picture of the tongue from an integrated as well as an analytical perspective.
文摘Thirty adult upper extremities were used to study the arteries of the hand byangiography,cross-sectional dissection and three-dimensional reconstruction withmicrocomputer.The arterial skeleton of the palm was composed of superficial,deep anddorsal planes.There were three main anastomotic pathways between the radial and ulnararteries or their branches in the radio-ulnar direction,while in the palmar dorsal dirce-tion there were three anastomotic zones between the palrnar and dorsal arterial plancs.The branches of the deep palmar arch radiated distally,proximally,palmarly anddorsally,so that the arch acted as the center of the arterial network of the hand.Thetransverse arterial allocations in the carpo-metacarpal segment of the palm were four intypes,but in the mid-palmar and metacarpo-phalangcal segments were three only.Accord-ing to the sources,cross-sectional area,irrigation territories and anastomoses of the ar-teries in each segment,the clinical significance in the rcplantation of the amputatcd palmshas been
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11675019 and 11875087).
文摘The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical devices,3D-XRF analysis with a micro confocal volume will create a great potential for 2D and 3D microstructural analysis and accurate quantitative analysis.However,the classic measurement method of scanning metal foils of a certain thickness leads to inaccuracy.A method for calibrating the confocal volume is proposed in this paper.The new method is based on the basic content of the textbook,and the theoretical results and the feasibility are given in detail for the 3D-XRF mono-chromatic x-ray condition and the poly-chromatic x-ray condition.We obtain a set of experimental confirmation using the poly-chromatic x-ray tube in the laboratory.It is proved that the sensitivity factor of the 3D-XRF can be directly and accurately obtained in a real calibration process.
文摘Background: The suitability of micro-computed tomography (CT) for soft tissue applications has been well documented. Although the application of micro-CT to the three dimensional (3D) structure of the tongue muscle has been reported, a 3D rendering and/or a schematic view of the tongue muscle has yet to be published. Material and Method: First, muse tongues were fixed and decalcified, and then the vertical muscle (Ve), the transverse muscle (Tr), and/or the genioglossus muscle of the mouse tongue (Ge) were analyzed using micro-CT and are shown in this report in rendered images and pattern diagrams. Results: 1) The Tr is classified into three parts: the first part extends from the middle to the apical part of the tongue;the second part is strongly connected to the superior longitudinal muscles of the tongue (Lo);the third part fans out from the middle to the root of the tongue. 2) The Ve is classified into two main groups: the first group joins the dorsal and the lateral parts of the tongue;the second group joins the dorsal part and the floor of the tongue. 3) Ge is classified into four parts: three parts comprise the Ge apical and middle parts of the tongue, with one part in the inferior longitudinal muscles of the tongue, one joining the lingual septum of the tongue (LS), and the other joining the sub-surface of the dorsal part of the Lo. The remaining Ge exits in a fan-like manner through the root of the tongue and then joins the Tr.
基金supported by grants from the National Key Research and Development Plan of China,No.31670986(to QTZ)the Science and Technology Project of Guangdong Province of China,No.2014B020227001,2017A050501017(to QTZ)the Science and Technology Project of Guangzhou of China,No.201807010082(to QTZ),201704030041(to JQ)
文摘The most common methods for three-dimensional reconstruction of peripheral nerve fascicles include histological and radiology techniques. Histological techniques have many drawbacks including an enormous manual workload and poor image registration. Micro-magnetic resonance imaging(Micro-MRI), an emerging radiology technique, has been used to report results in the brain, liver and tumor tissues. However, micro-MRI usage for obtaining intraneural structures has not been reported. The aim of this study was to present a new imaging method for three-dimensional reconstruction of peripheral nerve fascicles by ~1T micro-MRI. Freshly harvested sciatic nerve samples from an amputated limb were divided into four groups. Two different scanning conditions(Mannerist Solution/GD-DTPA contrast agent, distilled water) were selected, and both T1 and T2 phases programmed for each scanning condition. Three clinical surgeons evaluated the quality of the images via a standardized scale. Moreover, to analyze deformation of the two-dimensional image, the nerve diameter and total area of the micro-MRI images were compared after hematoxylin-eosin staining. The results show that rapid micro-MRI imaging method can be used for three-dimensional reconstruction of the fascicle structure. Nerve sample immersed in contrast agent(Mannerist Solution/GD-DTPA) and scanned in the T1 phase was the best. Moreover, the nerve sample was scanned freshly and can be recycled for other procedures. MRI images show better stability and smaller deformation compared with histological images. In conclusion, micro-MRI provides a feasible and rapid method for three-dimensional reconstruction of peripheral nerve fascicles, which can clearly show the internal structure of the peripheral nerve.
基金National Key Research and Development Project during the 14th Five-year Plan Period(2023YFF0905800)Science and Technology Program of Jiangxi Provincial Education Department(GJJ160879)。