To utilize heat and electricity in a clean and integrated manner,a zero-carbon-emission micro Energy Internet(ZCE-MEI) architecture is proposed by incorporating non-supplementary fired compressed air energy storage(NS...To utilize heat and electricity in a clean and integrated manner,a zero-carbon-emission micro Energy Internet(ZCE-MEI) architecture is proposed by incorporating non-supplementary fired compressed air energy storage(NSF-CAES) hub.A typical ZCE-MEI combining power distribution network(PDN) and district heating network(DHN) with NSF-CAES is considered in this paper.NSF-CAES hub is formulated to take the thermal dynamic and pressure behavior into account to enhance dispatch flexibility.A modified Dist Flow model is utilized to allow several discrete and continuous reactive power compensators to maintain voltage quality of PDN.Optimal operation of the ZCE-MEI is firstly modeled as a mixed integer nonlinear programming(MINLP).Several transformations and simplifications are taken to convert the problem as a mixed integer linear programming(MILP)which can be effectively solved by CPLEX.A typical test system composed of a NSF-CAES hub,a 33-bus PDN,and an 8-node DHN is adopted to verify the effectiveness of the proposed ZCE-MEI in terms of reducing operation cost and wind curtailment.展开更多
基金supported in part by the National Natural Science Foundation of China(No.51321005,No.51377092,No.51577163)Opening Foundation of the Qinghai Province Key Laboratory of Photovoltaic Power Generation and Grid-connected Technology
文摘To utilize heat and electricity in a clean and integrated manner,a zero-carbon-emission micro Energy Internet(ZCE-MEI) architecture is proposed by incorporating non-supplementary fired compressed air energy storage(NSF-CAES) hub.A typical ZCE-MEI combining power distribution network(PDN) and district heating network(DHN) with NSF-CAES is considered in this paper.NSF-CAES hub is formulated to take the thermal dynamic and pressure behavior into account to enhance dispatch flexibility.A modified Dist Flow model is utilized to allow several discrete and continuous reactive power compensators to maintain voltage quality of PDN.Optimal operation of the ZCE-MEI is firstly modeled as a mixed integer nonlinear programming(MINLP).Several transformations and simplifications are taken to convert the problem as a mixed integer linear programming(MILP)which can be effectively solved by CPLEX.A typical test system composed of a NSF-CAES hub,a 33-bus PDN,and an 8-node DHN is adopted to verify the effectiveness of the proposed ZCE-MEI in terms of reducing operation cost and wind curtailment.