期刊文献+
共找到19篇文章
< 1 >
每页显示 20 50 100
Experimental Investigation of Solar Panel Cooling by a Novel Micro Heat Pipe Array 被引量:4
1
作者 Xiao Tang Zhenhua Quan Yaohua Zhao 《Energy and Power Engineering》 2010年第3期171-174,共4页
A novel micro heat pipe array was used in solar panel cooling. Both of air-cooling and water-cooling conditions under nature convection condition were investigated in this paper. Compared with the ordinary solar panel... A novel micro heat pipe array was used in solar panel cooling. Both of air-cooling and water-cooling conditions under nature convection condition were investigated in this paper. Compared with the ordinary solar panel, the maximum difference of the photoelectric conversion efficiency is 2.6%, the temperature reduces maximally by 4.7℃, the output power increases maximally by 8.4% for the solar panel with heat pipe using air-cooling, when the daily radiation value is 26.3 MJ. Compared with the solar panel with heat pipe using air-cooling, the maximum difference of the photoelectric conversion efficiency is 3%, the temperature reduces maximally by 8℃, the output power increases maximally by 13.9% for the solar panel with heat pipe using water-cooling, when the daily radiation value is 21.9 MJ. 展开更多
关键词 Solar PANEL COOLING PHOTOELECTRIC CONVERSION Efficiency micro Heat PIPE array
下载PDF
A Status Graph Based Control Allocation Algorithm of Digital Micro-Thruster Array for Micro/Nano-Satellites Orbit Control Application
2
作者 ZHANG Dandan ZHANG Yunyi +2 位作者 DONG Ke LI Haiwang WANG Shaoping 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2019年第5期779-788,共10页
Digital micro-thruster arrays can be used for special missions of micro/nano-satellites with the requirements of high precision and small impulse.This paper presents a novel control allocation algorithm for the digita... Digital micro-thruster arrays can be used for special missions of micro/nano-satellites with the requirements of high precision and small impulse.This paper presents a novel control allocation algorithm for the digital micro-thruster array,namely status graph based control allocation(SGBCA)algorithm,which aims at finding the optimal micro thrusters combination scheme to realize the sequential control synthesis for micro/nano-satellite during real-time orbit control tasks.A mathematical model is set up for the control allocation of this multivariate over-actuated system.Through dividing thrusters into disjoint segments by offline calculation and combining segments dynamically online to provide a sequence of the required impulse for the micro/nano-satellite,the time complexity of the control allocation algorithm decreases significantly.All levels of impulse can be generated by the digital micro thruster arrays and the service life of the arrays can be extended using the segment converting strategy proposed in this paper.The simulation indicates that the algorithm can satisfy the requirements of real-time orbit control for micro/nano-satellites. 展开更多
关键词 CONTROL allocation DIGITAL micro-THRUSTER array micro/nano-satellite orbit CONTROL
下载PDF
Micro Gas Sensor Array for Monitoring Highly Toxic Gases
3
作者 Duk-Dong Lee Nak-Jin Choi Kap-Duk Song 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期9-12,共4页
Recently,the possibility of a disaster due to the improper use of highly toxic gases which are known as agents throughout the world has been increased.Therefore,the development of technology for countermeasure against... Recently,the possibility of a disaster due to the improper use of highly toxic gases which are known as agents throughout the world has been increased.Therefore,the development of technology for countermeasure against CWA has been highly demanded.In this study,thick film SnO_2-based gas sensing devices were prepared and the sensing properties for the four different kinds of simulants such as dimethyl methyl phosphonate (DMMP),acetonitrile,dichloromethane and dipropylene glycol methyl ether have been investigated.And a micro sensor array consists of six devices was prepared using MEMS technology to provide high selective and reliable sensing system for the detection of chemical warfare agents.The micro gas sensor array prepared showed good sensitivity and selectivity to CWA. 展开更多
关键词 micro sensor array highly toxic gases sensitivity
下载PDF
Novel Fractal DGS Based on MEMS and Its Application in Miniaturization of Microstrip Antenna Array
4
作者 Yong-Zhong Chen 《Journal of Electronic Science and Technology》 CAS 2011年第3期250-255,共6页
An uncommon fractal construction method is applied in the microwave element design. A novel fractal defected ground structure (DGS) based on micro electro-mechanical system (MEMS) is proposed. The size of this nov... An uncommon fractal construction method is applied in the microwave element design. A novel fractal defected ground structure (DGS) based on micro electro-mechanical system (MEMS) is proposed. The size of this novel fractal DGS can achieve 86% size reduction compared with the conventional dumbbell type DGS. This novel fractal DGS is used in the miniaturization design of L-band microstrip antenna array. The simulation result shows that this novel fractal DGS can effectively reduce the mutual coupling between the antenna elements, so it is helpful to the miniaturization of microstrip array, namely the approximately same gain value can be achieved with the shorter distance between elements. 展开更多
关键词 Index Terms---Defected ground structure FRACTAL micro electro-mechanical-system microstrip antenna array miniaturization.
下载PDF
Immunohistochemical analysis of 8 biomarkers on tissue microarray (TMA) of 46 Moroccan invasive breast carcinoma
5
作者 Mariam Amrani Habiba Kadiri +3 位作者 Salma Bekarsabein Lorenzo Memeo Mohamed Alaoui Belabbas Mahash Mansukhani 《Journal of Biomedical Science and Engineering》 2013年第10期1014-1020,共7页
Aim of the study: Immunohistochemical evaluation of hormone receptors, Her2/neu, CK5/6, E-cadherin, beta-catenin, p53 and PTEN on Tissue Micro Array (TMA) of 46 Moroccan invasive breast carcinomas. Materials and Metho... Aim of the study: Immunohistochemical evaluation of hormone receptors, Her2/neu, CK5/6, E-cadherin, beta-catenin, p53 and PTEN on Tissue Micro Array (TMA) of 46 Moroccan invasive breast carcinomas. Materials and Methods: The cases comprised 40 invasive ductal carcinomas, 4 invasive lobular carcinomas, 1 mixed carcinoma and 1 invasive colloid carcinoma. TMA paraffin blocs were prepared with the Beecher manual arrayer and immunostaining was performed using standard immunoperoxidase techniques. Results: 58.69% of the cases were ER positive. 43.18% (19/44) were triple negative breast cancers (TNBC) of which 15.78% (3/19) were of the basal phenotype expressing CK5/6. On the other hand, 72.22% (13/18) of the TNBC cases were IDC grade 3. Of the 18 IDC grade 3, 22.22% (4/18) were CK5/6 positive. 41.30% and 10.86% of the cases showed reduced expression of E-cadherin and beta-catenin respectively. Beta-catenin nuclear and cytoplasmic staining was noted in 20% and 97.82% respectively. p53 was overexpressed in 10.86% of the cases whereas PTEN loss or reduced expression was noted in 86.95% of the cases. Conclusion: The aim of our study was to introduce TMA technique in our hospital which is considered a reference institution for cancer in Morocco. Although no statistical study was performed to look for any significance of the results obtained, we found good correlation with some of the data in the literature. To determine the molecular characteristics, if any, of the Moroccan patient, larger multidisciplinary and prospective studies would be interesting in the aim to personalize therapeutic decisions. 展开更多
关键词 Invasive Breast Carcinoma Tissue micro array HORMONE Receptors HER2/NEU CK5/6 p53 PTEN BETA-CATENIN E-Cadherin
下载PDF
SILICON NEEDLE ARRAY ON FLEXIBLE SUBSTRATE FOR FLUID TRANSFER 被引量:1
6
作者 MA Bin GAN Zhiyin LIU Sheng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第3期387-390,共4页
Transdermal delivery is an attractive alternative, but it is limited by the extremely low permeability of skin. To solve this problem, a novel means--micro needle array based on micro electro-mechanical system (MEMS... Transdermal delivery is an attractive alternative, but it is limited by the extremely low permeability of skin. To solve this problem, a novel means--micro needle array based on micro electro-mechanical system (MEMS) technology, is provided to increase permeability of human skin with efficiency, safety and painless delivery. The fabrication method consists of a sequence of deep-reactive ion etching (DRIE), anisotropic wet etching and conformal thin film deposition. The novel technology can enable the realization of micro fabricated micro needle array on a flexible silicon substrate. The micro needle array can be mounted on non-planar surface or even on flexible objects such as a human fingers and arms. The fabricated hollow wall straight micro needles are 200 μm in length, 30 μm inner diameter, and 50 μm outer diameter with 250 μm center-to-center spacing. Flow rate test proves that the polymeric base construction is important to function of micro needles array in package. Glucose solvent tests show that surface tension is the dominant force to affect the characters of flow in micro needles channel. 展开更多
关键词 micro needles array Drug delivery Flexibility Packaging Transdermal delivery
下载PDF
Fabrication of Ordered Micro/Nanostructures Using Probe‑Based Force‑Controlled Micromachining System
7
作者 Yanquan Geng Yuzhang Wang +2 位作者 Jianxiong Cai Jingran Zhang Yongda Yan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2022年第6期178-193,共16页
This paper presents a probe-based force-controlled nanoindentation method to fabricate ordered micro/nanostructures.Both the experimental and finite element simulation approaches are employed to investigate the influe... This paper presents a probe-based force-controlled nanoindentation method to fabricate ordered micro/nanostructures.Both the experimental and finite element simulation approaches are employed to investigate the influence of the interval between the adjacent indentations and the rotation angle of the probe on the formed micro/nanostructures.The non-contacting part between indenter and the sample material and the height of the material pile-up are two competing factors to determine the depth relationship between the adjacent indentations.For the one array indentations,nanostructures with good depth consistency and periodicity can be formed after the depth of the indentation becoming stable,and the variation of the rotation angle results in the large difference between the morphology of the formed nanostructures at the bottom of the one array indentation.In addition,for the indentation arrays,the nanostructures with good consistency and periodicity of the shape and depth can be generated with the spacing greater than 1μm.Finally,Raman tests are also carried out based on the obtained ordered micro/nanostructures with Rhodamine probe molecule.The indentation arrays with a smaller spacing lead to better the enhancement effect of the substrate,which has the potential applications in the fields of biological or chemical molecular detection. 展开更多
关键词 Ordered micro/nanostructure Probe-based micromachining In-process force-controlled Indentation array micro cutting
下载PDF
A Novel Stacked Array Antenna with Uni-planar Compact EBG Reflector
8
作者 Peng Chen Chaoyang Chen +1 位作者 Xiaodong Yang Xiaoming Zhu 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2015年第1期59-62,共4页
Most broadband microstrip antennae are implemented in the form of slot structure or laminate structure,which provide a broad impedance bandwidth and meanwhile bring large sidelobes and backlobes. A novel uni-planar co... Most broadband microstrip antennae are implemented in the form of slot structure or laminate structure,which provide a broad impedance bandwidth and meanwhile bring large sidelobes and backlobes. A novel uni-planar compact electromagnetic band-gap( EBG) structure is proposed, which shows excellent performance when applied to broadband stacked or aperture coupled microstrip array antennae. The test results indicate that,the directivity is effectively improved,and the front-to-back ratio is increased,and the thickness of the antenna is reduced. These improvements make this structure better used in airborne antennae. 展开更多
关键词 EBG UC-EBG microSTRIP array antenna stacked microS
下载PDF
Light field head-mounted display with correct focus cue using micro structure array 被引量:4
9
作者 宋维涛 王涌天 +1 位作者 程德文 刘越 《Chinese Optics Letters》 SCIE EI CAS CSCD 2014年第6期39-42,共4页
A new type of light fiehl display is proposed using a head-mounted display (HMD) and a micro structure array (MSA, lens array or pinhole array). Each rendering point emits abundant rays from different directions i... A new type of light fiehl display is proposed using a head-mounted display (HMD) and a micro structure array (MSA, lens array or pinhole array). Each rendering point emits abundant rays from different directions into the viewer's pupil, and at one time the dense light field is generated inside the exit pupil of the HMD through the eyepiece. Therefore, the proposed method not only solves the problem of accommodation and convergence conflict in a traditional HMD, but also drastically reduces the huge data in real three-dimensional (3D) display. To demonstrate the proposed method, a prototype is developed, which is capable of giving the observer a real perception of depth. 展开更多
关键词 HMD Light field head-mounted display with correct focus cue using micro structure array MSA head
原文传递
Performance simulation and optimization of new radiant floor heating based on micro heat pipe array 被引量:2
10
作者 Heran Jing Zhenhua Quan +3 位作者 Ruixue Dong Limin Hao Yunhan Liu Yaohua Zhao 《Building Simulation》 SCIE EI CSCD 2022年第7期1295-1308,共14页
This paper proposes two new radiant floor heating structures based on micro heat pipe array(MHPA),namely cement-tile floor and keel-wood floor.The numerical models for these different floor structures are established ... This paper proposes two new radiant floor heating structures based on micro heat pipe array(MHPA),namely cement-tile floor and keel-wood floor.The numerical models for these different floor structures are established and verified by experiments.The temperature distribution and heat transfer process of each part are comprehensively obtained,and the structure is optimized.The results show that the cement-tile floor has the better heat transfer performance of the two.When under the same inlet water temperature and flow rate,the keel-wood floor's surface temperature distribution is about 2℃ lower than that of the cement-tile floor.The inlet water temperature of cement-tile floor is about 10℃ lower than that of keel-wood structure when the floor surface temperature is the same.During a longitudinal heat transfer above MHPA,the floor surface temperature decreases by 0.5℃ for every 10 mm filling layer increase.In order to reduce the non-uniformity of the floor's surface temperature and improve the thermal comfort of the heated room,the optimal structure for a floor is given,with the maximum surface temperature difference reduced by 3.35℃.We used research focusing on new radiant floor heating,with advantages including high efficiency heat transfer,low water supply temperature,simple waterway structure,low resistance and leakage risk,to provide theory and data to support the application of an effective radiant floor heating based on MHPA. 展开更多
关键词 radiant floor heating micro heat pipe array numerical simulation heat transfer
原文传递
Numerical and Experimental Investigation on the Performance of Battery Thermal Management System Based on Micro Heat Pipe Array 被引量:1
11
作者 YANG Lulu XU Hongbo +3 位作者 ZHANG Hainan CHEN Yiyu LIU Ming TIAN Changqing 《Journal of Thermal Science》 SCIE EI CAS CSCD 2022年第5期1531-1541,共11页
Battery thermal management is very crucial for the safe and long-term operation of electric vehicles or hybrid electric vehicles.In this study,numerical simulation method is adopted to simulate the temperature field o... Battery thermal management is very crucial for the safe and long-term operation of electric vehicles or hybrid electric vehicles.In this study,numerical simulation method is adopted to simulate the temperature field of Li-ion battery cell and module.It is proved that the maximum temperature and maximum temperature difference of battery cell and module increase with the increase of charge/discharge rate(C-rate)of the battery.For battery module,it can reach a maximum temperature of 61.1℃at a C-rate of 2 under natural convection condition with the ambient temperature of 20.0℃.A battery thermal management system based on micro heat pipe array(BTMS-MHPA)is deeply investigated.Experiments are conducted to compare the cooling effect on the battery module with different cooling methods,which include natural cooling,only MHPA,MHPA with fan.The maximum temperature of battery module which is cooled by MHPA with a fan is 43.4℃at a C-rate of 2,which is lower than that in the condition of natural cooling.Meanwhile,the maximum temperature difference was also greatly reduced by the application of MHPA cooling.The experimental results confirm that the feasibility and superiority of the BTMS-MHPA for guaranteeing the working temperature range and temperature uniformity of the battery. 展开更多
关键词 battery thermal management micro heat pipe array Li-ion battery temperature field
原文传递
Thermal Performance of a Micro Heat Pipe Array for Battery Thermal Management Under Special Vehicle-Operating Conditions 被引量:1
12
作者 Chengning Yao Dan Dan +4 位作者 Yangjun Zhang Yueqi Wang Yuping Qian Yuying Yan Weilin Zhuge 《Automotive Innovation》 CSCD 2020年第4期317-327,共11页
The thermal management of battery systems is critical for maintaining the energy storage capacity,life span,and thermal safety of batteries used in electric vehicles,because the operating temperature is a key factor a... The thermal management of battery systems is critical for maintaining the energy storage capacity,life span,and thermal safety of batteries used in electric vehicles,because the operating temperature is a key factor affecting battery performance.Excessive temperature rises and large temperature differences accelerate the degradation rate of such batteries.Currently,the increasing demand for fast charging and special on-vehicle scenarios has increased the heat dissipation requirements of battery thermal management systems.To address this demand,this work proposes a novel micro heat pipe array(MHPA)for thermal management under a broadened research scope,including high heat generation rates,large tilt angles,mild vibration,and distributed heat generation conditions.The experimental results indicate that the temperature difference is maintained 3.44°C at a large heat generation of 50 W for a limited range of tilt angles.Furthermore,a mild vehicle vibra-tion condition was found to improve temperature uniformity by 3.3°C at a heat generation of 10 W.However,the use of distributed heat sources results in a temperature variation of 3.88°C,suggesting that the heat generation distribution needs to be considered in thermal analyses.Understanding the effects of these special battery-operating conditions on the MHPA could significantly contribute to the enhancement of heat transfer capability and temperature uniformity improvement of battery thermal management systems based on heat pipe technologies.This would facilitate the realization of meeting the higher requirements of future battery systems. 展开更多
关键词 Battery thermal management Thermal performance micro heat pipe array Operating conditions
原文传递
Partially-Premixed Combustion Characteristics and Thermal Performance of Micro Jet Array Burners with Different Nozzle Spacings
13
作者 YANG Haolin WU Yong +2 位作者 ZENG Xiaojun WANG Xiaohan ZHAO Daiqing 《Journal of Thermal Science》 SCIE EI CAS CSCD 2021年第5期1718-1730,共13页
In order to develop a burner with uniform temperature field,the combustion characteristics and thermal performance of partially premixed methane/air jet flames were experimentally studied by using micro jet array burn... In order to develop a burner with uniform temperature field,the combustion characteristics and thermal performance of partially premixed methane/air jet flames were experimentally studied by using micro jet array burners.The circular tubes of 1.0-mm inner diameter and 1.5-mm outer diameter were used as nozzles.The effects of nozzle spacing and equivalence ratio on flame phenomenology,temperature distribution and pollutant emissions were respectively investigated by camera photography,thermocouple measurement and sampling analysis.Results show that there are two clean flame patterns:clean merged-flame and clean non-merging flames.The flame patterns depend on the strength of flame interaction,the equivalence ratio of the mixture and the quantity of air entrainment through the gap between nozzles.The burners with small nozzle spacing such as 2 mm and 2.5 mm tend to produce fully merged flame with low equivalence ratio limit and the corresponding temperature fields are very uniform with fluctuations less than 0.3%,but a small increase in equivalence ratio will lead to rapid deterioration of combustion property.The burner with a medium spacing of 3 mm can produce partially merged flame in a wide equivalence ratio range with low emissions,and the temperature fluctuation can be less than 0.5%(<7 K)in the optimal region.The burner with a large spacing of 4 mm will basically form independent array flames with the largest temperature fluctuation over 1%,while it can achieve clean combustion under high equivalence ratio due to large air entrainment.Comprehensive analysis shows that the micro jet array burner with medium nozzle spacing of 3 mm has the best combustion characteristics and thermal performance. 展开更多
关键词 micro jet array burner flame interaction methane/air flame temperature fluctuation thermal performance
原文传递
Highly precise micro torsion angle detection by fringe array
14
作者 高旸 王省书 +2 位作者 胡春生 黄宗升 战德军 《Chinese Optics Letters》 SCIE EI CAS CSCD 2014年第8期10-14,共5页
Pringe array is proposed as the cooperated target in the precise torsion angle detection. The target fringe array image is generated according to the structure of the optical system, and the torsion angle detection al... Pringe array is proposed as the cooperated target in the precise torsion angle detection. The target fringe array image is generated according to the structure of the optical system, and the torsion angle detection algorithm is analyzed in response to the gray distribution of the image. The factors affecting the detection precision of the fringe torsion angle are analyzed theoretically and numerically. It indicates that the detection precision of the torsion angle is 1 angular second or even less, carefully selecting the detector array. Significantly, experiments are performed to demonstrate the precision and the results match well with the simulations. 展开更多
关键词 Highly precise micro torsion angle detection by fringe array length
原文传递
Influence of Parameters in the Design of a Faceted Structure for Incoherent Beam Shaping
15
作者 Lihong Liu Thierry Engel- +4 位作者 Huwen Ding Yuanzhi Cui Jing Zhang Yayi Wei Manuel Flury 《Journal of Microelectronic Manufacturing》 CAS 2021年第4期1-11,共11页
A reflective faceted structure is proposed to reshaping an incoherent light beam into two focalized spots-To obtain the desired irradiance distribution on a detector,custom optimization function is written,and the two... A reflective faceted structure is proposed to reshaping an incoherent light beam into two focalized spots-To obtain the desired irradiance distribution on a detector,custom optimization function is written,and the two dimensional tilt angles of each facet are optimized automatically in a pure non-sequential mode in Zemax OpticStudio 16.The result is also confirmed inside LightTools&2 from Synopsys.For measuring the quality of the optimization result in the case of two spots focalization,four factors including efficiency on the detector,uniformity,the root mean square error and the correlation coefficient are calculated.These four factors are used to evaluate the influence of several parameters on the irradiance distribution.These parameters include the incidence angle,the divergence angle,the facet size,the source type and the resolution of the facet angular positions.Finally,an analysis of those parameters is made and the performance of this type of component is demonstrated. 展开更多
关键词 Incoherent beam shaping micro lens array custom optimization
下载PDF
Tsinghua-1 Micro-Satellite Power System Architecture and Design 被引量:4
16
作者 吴知非 尤政 《Tsinghua Science and Technology》 SCIE EI CAS 2001年第4期289-293,共5页
The Tsinghua 1 Micro satellite, the first satellite made by Tsinghua University, was launched in 2000. The power system of the Tsinghua 1 Micro satellite is one of the most important subsystems. It provides all... The Tsinghua 1 Micro satellite, the first satellite made by Tsinghua University, was launched in 2000. The power system of the Tsinghua 1 Micro satellite is one of the most important subsystems. It provides all the power for the satellite platform and the payloads. The power system design includes the regulation, protection and distribution of a 4×35 W solar array and 7 Ah NiCd batteries. This subsystem essentially offers two buses: an unregulated 14 V bus and a regulated 5 V bus. All distributed power lines to the users are protected by current tripping switches. In addition, some essential loads, such as the tele command system, are supplied through fuses. The Tsinghua 1 Micro satellite power system provides an efficient, flexible, reliable, and cost effective solution for small satellites in low earth orbit. A better maximum power point tracking method has been used to increase reliability margins and to increase the efficiency of the power system. The power system reliability was evaluated using several different tests, such as the power board test, the assembly integrate test (AIT), the electromagnetic compatibility (EMC) test and the thermal vacuum test (TVT). 展开更多
关键词 micro satellite power system solar array BATTERY
原文传递
The Research on Micro Electronic-Magnetic Forming of Sheet Metal
17
作者 ZHAO Qing-juan GUO Bin +3 位作者 WANG Chun-ju SHAN De-bin YU Hai-ping LI Chun-feng 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2012年第S1期434-437,共4页
Micro channel of T2 copper were molding through electronic-magnetic forming experiments.Laser scanning confocal microscope and contourgraph were used to measure the section profile and sheet thickness.The effects of v... Micro channel of T2 copper were molding through electronic-magnetic forming experiments.Laser scanning confocal microscope and contourgraph were used to measure the section profile and sheet thickness.The effects of voltage,shape of channel and discharge cycles on laws of metal flow were studied.Results showed that forming depth of micro channel and thinning of sheet thickness increased as the increasing of the voltage.Mold-filling capacity of components formed by two molds with different structures had been increased when the voltage was increased.Mold with semicircle structure facilitate the material flow and the forming depth of parts was relative large.Semicircle structure was better than taper structure in mold-filling capacity.A number of small pulse discharges can improve the forming quality and deformation,but local thinning in sheet metal leads to non-uniform distribution of thickness. 展开更多
关键词 electromagnetic forming array microstructure foil board micro forming micro channel
原文传递
Express and sensitive detection of multiple miRNAs via DNA cascade reactors functionalized photonic crystal array
18
作者 Yingfei Wang Yuyi Li +3 位作者 Yue Zhang Kewei Ren Huangxian Ju Ying Liu 《Science China Chemistry》 SCIE EI CAS CSCD 2020年第5期731-740,共10页
Array based detection techniques with fluorescence signal reading is a powerful tool for multiple targets analysis. However,when applied fluorescence array for micro RNA detection, time-consuming multi-steps surface s... Array based detection techniques with fluorescence signal reading is a powerful tool for multiple targets analysis. However,when applied fluorescence array for micro RNA detection, time-consuming multi-steps surface signal amplification is usually required due to the low abundance of micro RNA in total RNA expressions, which impairs detection efficiency and limits its application in point of care test(POCT) manner. Herein, DNA cascade reactors(DCRs) functionalized photonic crystal(PC)array was fabricated for express and sensitive detections of mi RNA-21 and mi RNA-155. DCRs were assembled by interval conjugation of self-quenched hairpin DNA probes to single strand DNA nanowire synthesized by rolling circle amplification,which generated cascade DNA hybridization reactions in response to target mi RNAwith instant fluorescence recovery signal. PC array patterns with multi-structure colors further amplified fluorescence with their respective photonic bandgaps(PBGs)matching with the emission peaks of fluorescence molecules labelled on DCRs. The as-prepared DCRs functionalized PC array demonstrated express and sensitive simultaneous detections of mi RNA-21 and mi RNA-155 with hundreds f M detection limits only in 15 min, and was successfully applied in fast quantifications of low abundance mi RNAs from cell lysates and spiked mi RNAs from human serum, which would hold great potential for disease diagnosis and therapeutic effect monitoring with a POCT manner. 展开更多
关键词 micro RNA detection photonic crystal array DNA cascade reactors fluorescence amplification express detection
原文传递
Polarization Band Effect and MEMS-Based Plasma Generation
19
作者 Henggao Ding Zhongyu Hou 《Instrumentation》 2024年第2期1-8,共8页
We find that effects resulting from micro/nano scale structures can regulate space charges which excite and lead to the special electric field distribution featuring the flux convergence band structure. It is here ref... We find that effects resulting from micro/nano scale structures can regulate space charges which excite and lead to the special electric field distribution featuring the flux convergence band structure. It is here referred to as the polarization band effect, which stems from the specific field-induced interactions among atoms and molecules. The micro/nanoelectrode array structures were designed and fabricated using the non-silicon micro/nano processing technology, forming micro/nano electrode arrays-based plasma microelectromechanical systems(NPMEMS). The integrated NPMEMS device can be used to regulate the inner energy states of matters and generate plasma based on the polarization band effect, all within a single chip-size limited local area or extending into a large volume space with the deployment of a distributed array of multiple devices. Its special physical and chemical properties can be utilized to greatly improve the efficiency of potential application systems or solve mechanism-level challenges in plasma-related applications of multiple fields. 展开更多
关键词 polarization band effect MEMS micro/nanoelectrode array plasma
下载PDF
上一页 1 下一页 到第