Micro-Computed Tomography Applications in Dentistry
1
作者 Ahmad Assari Maha Al Bukairi Reema Al Saif 《Open Journal of Stomatology》 2024年第1期32-41,共10页
Micro-computed tomography (MCT) encompasses two primary scanning options: ex-vivo and in-vivo imaging. Ex-vivo scanning involves the examination of extracted teeth or dental specimens, allowing for detailed analyses o... Micro-computed tomography (MCT) encompasses two primary scanning options: ex-vivo and in-vivo imaging. Ex-vivo scanning involves the examination of extracted teeth or dental specimens, allowing for detailed analyses of the microarchitecture of mineralized tissue. By analyzing the microarchitecture of dental tissues, MCT can provide valuable information about bone density, porosity, and microstructural changes, contributing to a better understanding of disease progression and treatment outcomes. Moreover, MCT facilitates the quantification of dental parameters, such as bone volume, trabecular thickness, and connectivity density, which are crucial for evaluating the efficacy of dental interventions. This present study aims to comprehensively review and explore the applications of MCT in dentistry and highlight its potential in advancing research and clinical practice. The results depicted that the quantitative approach of MCT enhances the precision and reliability of dental research. Researchers and clinicians can make evidence-based decisions regarding treatment strategies and patient management, relying on quantifiable data provided by MCT. The applications of MCT in dentistry extend beyond research, with potential clinical implications in fields such as dental implantology and endodontics. MCT is expected to play an increasingly significant role in enhancing our understanding of dental pathologies, improving treatment outcomes, and ultimately, benefiting patient care in the field of dentistry. 展开更多
关键词 Clinical Practice DENTISTRY Ex-Vivo Scanning micro-computed Tomography
下载PDF
Comparative study of chitosan/fibroin–hydroxyapatite and collagen membranes for guided bone regeneration in rat calvarial defects: micro-computed tomography analysis 被引量:15
2
作者 Jae Min Song Sang Hun Shin +4 位作者 Yong Deok Kim Jae Yeol Lee Young Jae Baek Sang Yong Yoon Hong Sung Kim 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第2期87-93,共7页
This study aimed to utilize micro-computed tomography (micro-CT) analysis to compare new bone formation in rat calvarial defects using chitosan/fibroin-hydroxyapatite (CFB-HAP) or collagen (Bio-Gide) membranes. ... This study aimed to utilize micro-computed tomography (micro-CT) analysis to compare new bone formation in rat calvarial defects using chitosan/fibroin-hydroxyapatite (CFB-HAP) or collagen (Bio-Gide) membranes. Fifty-four (54) rats were studied. A circular bony defect (8 mm diameter) was formed in the centre of the calvaria using a trephine bur. The CFB-HAP membrane was prepared by thermally induced phase separation. In the experimental group (n= 18), the CFB-HAP membrane was used to cover the bony defect, and in the control group (n= 18), a resorbable collagen membrane (Bio-Gide) was used. In the negative control group (n= 18), no membrane was used. In each group, six animals were euthanized at 2, 4 and 8 weeks after surgery. The specimens were then analysed using micro-CT. There were significant differences in bone volume (BV) and bone mineral density (BMD) (P〈O.05) between the negative control group and the membrane groups. However, there were no significant differences between the CFB-HAP group and the collagen group. We concluded that the CFB-HAP membrane has significant potential as a guided bone regeneration (GBR) membrane. 展开更多
关键词 chitosan/fibroin-hydroxyapatite collagen membrane guided bone regeneration micro-computed tomography rat calva rial defect
下载PDF
Investigating microstructure of Longmaxi shale in Shizhu area,Sichuan Basin, by optical microscopy, scanning electron microscopy and micro-computed tomography 被引量:7
3
作者 Yu Wang Li-Hua Wang +3 位作者 Jian-Qiang Wang Zheng Jiang Chan Jin Yan-Fei Wang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第11期226-235,共10页
Microstructure of shale formation is the key to understanding its petrophysical and chemical properties.Optical microscopy, scanning electron microscopy and micro-computed tomography(μ-CT) have been combined for char... Microstructure of shale formation is the key to understanding its petrophysical and chemical properties.Optical microscopy, scanning electron microscopy and micro-computed tomography(μ-CT) have been combined for characterization of microstructure of Longmaxi(LMX)shale from Shizhu area, Sichan Basin. The results indicate that laminated LMX shale consists of mineral matrix-rich layers and organic matter(OM)-rich layers at micrometer scale in two and three dimensions. Mineral matrix layers,mainly consisting of interparticle pores and intraplatelet pores, are approximately parallel to the bedding plane.Pyrite-rich layer, mainly containing intercrystalline pores,shows a strong preferred orientation parallel to the bedding plane. OM-rich layer, mainly containing OM pores, seems to be discontinuous. In addition, intercrystalline pores are enriched in some layers, while OM pores are distributed irregularly in matrix layers. This vertical heterogeneity of pore microscopic structures in LMX shale is of great importance to understand its petrophysical and chemical properties. 展开更多
关键词 micro-computed tomography PORE MICROSTRUCTURE HETEROGENEITY Matrix LAYERS Longmaxi SHALE
下载PDF
Nondestructive Skeletal Imaging of Hyla suweonensis Using Micro-Computed Tomography 被引量:1
4
作者 Eunbin KIM Hacheol SUNG +3 位作者 Donghyun LEE Geunjoong KIM Dongha NAM Etmgsam KIM 《Asian Herpetological Research》 SCIE CSCD 2017年第4期235-243,共9页
We successfully obtained 3D skeletal images of Hyla suweonensis, employing a nondestructive method by applying appropriate anesthesia and limiting the radiation dose. H. suweonensis is a tree frog endemic to Korea and... We successfully obtained 3D skeletal images of Hyla suweonensis, employing a nondestructive method by applying appropriate anesthesia and limiting the radiation dose. H. suweonensis is a tree frog endemic to Korea and is on the list of endangered species. Previous studies have employed caliper-based measurements and two-dimensional (2D) X-ray imaging for anatomical analyses of the skeletal system or bone types of H. suweonensis. In this work we reconstructed three-dimensional (3D) skeletal images of H. suweonensis, utilizing a nondestructive micro-computed tomography (micro-CT) with a short scan and low radiation dose (i.e. 4 min and 0.16 Gy). Importantly, our approach can be applied to the imaging of 3D skeletal systems of other endangered frog species, allowing both versatile and high contrast images of anatomical structures without causing any significant damages to the living animal. 展开更多
关键词 Hyla suweonensis micro-computed tomography 3D skeletal structure Nondestructive imaging Endangered species Radiation dose.
下载PDF
Contrast-enhanced micro-computed tomography using Exi Tron nano6000 for assessment of liver injury
5
作者 Xiang-Wei Hua Tian-Fei Lu +6 位作者 Da-Wei Li Wei-Gang Wang Jun Li Zhen-Ze Liu Wei-Wei Lin Jian-Jun Zhang Qiang Xia 《World Journal of Gastroenterology》 SCIE CAS 2015年第26期8043-8051,共9页
AIM: To explore the potential of contrast-enhanced computed tomography(CECT) using Exi Tron nano6000 for assessment of liver lesions in mouse models.METHODS: Three mouse models of liver lesions were used: bile duct li... AIM: To explore the potential of contrast-enhanced computed tomography(CECT) using Exi Tron nano6000 for assessment of liver lesions in mouse models.METHODS: Three mouse models of liver lesions were used: bile duct ligation(BDL),lipopolysaccharide(LPS)/D-galactosamine(D-Gal N),and alcohol.After injection with the contrast agent Exi Tron nano6000,the mice were scanned with micro-CT.Liver lesions were evaluated using CECT images,hematoxylin and eosin staining,and serum aminotransferase levels.Macrophage distribution in the injury models was shown by immunohistochemical staining of CD68.The in vitro studies measured the densities of RAW264.7 under different conditions by CECT.RESULTS: In the in vitro studies,CECT provided specific and strong contrast enhancement of liver in mice.CECT could present heterogeneous images anddensities of injured livers induced by BDL,LPS/D-Gal N,and alcohol.The liver histology and immunochemistry of CD68 demonstrated that both dilated biliary tracts and necrosis in the injured livers could lead to the heterogeneous distribution of macrophages.The in vitro study showed that the RAW264.7 cell masses had higher densities after LPS activation.CONCLUSION: Micro-CT with the contrast agent Exi Tron nano6000 is feasible for detecting various liver lesions by emphasizing the heterogeneous textures and densities of CECT images. 展开更多
关键词 micro-computed TOMOGRAPHY ExiTronNano6000 LIVER INJURY
下载PDF
Microstructure Study of Normal Lunates with Micro-computed Tomography
6
作者 肖滋润 熊革 +2 位作者 shi-gong guo 杜传超 张友乐 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第3期384-389,共6页
In order to study the microstructure characteristics of normal lunate bones, eight fresh cadaver normal lunates were scanned with micro-computed tomography. High-resolution images of the micro-structure of normal luna... In order to study the microstructure characteristics of normal lunate bones, eight fresh cadaver normal lunates were scanned with micro-computed tomography. High-resolution images of the micro-structure of normal lunates were obtained and we analyzed the nutrient foramina. Then nine regions of interest(ROI) were chosen in the central sagittal plane so that we could obtain the parameters of trabecular bones of ROIs. The distal lamellar-like compact structure had statistically significant differences when it was compared with the ROIs in the volar and dorsal ends of the distal cortex. The difference of diameter between the volar and dorsal foramina was significant(P<0.05). However, there was no significant difference regarding the number. The trabecular bones of the volar and dorsal distal ends had lower intensity than those of the distal central subchondral bone plate. The diameters of the nutrient foramina on the volar cortex were larger than those on the dorsal. This research provided more detailed information about microstructure of normal lunate and the nutrient foramina on cortex, and a reference for further study about diseased lunate. 展开更多
关键词 normal lunate trabecular bones micro-computed tomography nutrient foramina
下载PDF
Monitoring vascular changes induced by photodynamic therapy using contrast-enhanced micro-computed tomography
7
作者 Otilia C. Nasui Stuart K. Bisland Nancy L. Ford 《Journal of Biomedical Science and Engineering》 2013年第2期124-133,共10页
The aim of this study was to determine whether contrast-enhanced micro-computed tomography can be used for non-invasive imaging of the early-stage changes in the vasculature of tumours that have been treated with phot... The aim of this study was to determine whether contrast-enhanced micro-computed tomography can be used for non-invasive imaging of the early-stage changes in the vasculature of tumours that have been treated with photodynamic therapy (PDT). The subjects used were C3H mice with an RIF-1 tumour implanted subcutaneously and allowed to grow for 3 weeks prior to treatment. The experimental groups were PDT-treated (150 J/cm2 and 50 J/cm2) and control (150 J/cm2 light-only and untreated). The laser light exposure was performed at 15 - 30 minutes after the administration of the photosensitizer (BPD-MA). The contrast-enhanced micro-computed tomography imaging procedure consisted of eight-second scans taking place before treatment and up to 24 hours after treatment. The 150 J/cm2 PDT group showed a significant increase in the ratio of blood volume to tumour volume at 2, 8 and 24 hours after treatment when compared to pre-treatment measurements (p 2 PDT group at 24 hours after treatment. This preliminary study indicates that micro-CT can detect compromised vasculature in tumours treated with high-fluence photodynamic therapy as early as 2 hours post treatment. 展开更多
关键词 micro-computed TOMOGRAPHY CONTRAST AGENT ANIMAL Model Photodynamic THERAPY Cancer
下载PDF
Micro-computed tomography assessment of human femoral trabecular bone for two disease groups(fragility fracture and coxarthrosis):Age and gender related effects on the microstructure
8
作者 Ana Catarina Vale Manuel F.C.Pereira +7 位作者 Antonio Maurício Bruno Vidal Ana Rodrigues Joana Caetano-Lopes Ara Nazarian Joao E.Fonseca Helena Canhao Maria Fatima Vaz 《Journal of Biomedical Science and Engineering》 2013年第2期175-184,共10页
The aim of this study was to identify three-dimensional microstructural changes of trabecular bone with age and gender, using micro-computed tomography. Human trabecular bone from two disease groups, osteoporosis and ... The aim of this study was to identify three-dimensional microstructural changes of trabecular bone with age and gender, using micro-computed tomography. Human trabecular bone from two disease groups, osteoporosis and osteoarthritis was analyzed. A prior analysis of the effects of some procedure variables on the micro-CT results was performed. Preliminary micro-CT scans were performed with three voxel resolutions and two acquisition conditions. On the reconstruction step, the image segmentation was performed with three different threshold values. Samples were collected from patients, with coxarthrosis (osteoarthritis) or fragility fracture (osteoporosis). The specimens of the coxarthrosis group include twenty females and fifteen males, while the fragility fracture group was composed by twenty three females and seven males. The mean age of the population was 69 ± 11 (females) and 67 ± 10 years (males), in the coxarthrosis group, while in the fragility fracture group was 81 ± 6 (females) and 78 ± 6 (males) years. The 30 μm voxel size provided lower percentage difference for the microarchitecture parameters. Acquisition conditions with 160 μA and 60 kV permit the evaluation of all the volume’s sample, with low average values of the coefficients of variation of the microstructural parameters. No statistically significant differences were found between the two diseases groups, neither between genders. However, with aging, there is a decrease of bone volume fraction, trabecular number and fractal dimension, and an increase of structural model index and trabecular separation, for both disease groups and genders. The parameters bone specific surface, trabecular thickness and degree of anisotropy have different behaviors with age, depending on the type of disease. While in coxarthrosis patients, trabecular thickness increases with age, in the fragility fracture group, there is a decrease of trabecular thickness with increasing age. Our findings indicate that disease, age and gender do not provide significant differences in trabecular microstructure. With aging, some parameters exhibit different trends which are possibly related to different mechanisms for different diseases. 展开更多
关键词 Trabecular Bone micro-computed Tomography Coxarthrosis Fragility Fracture Age GENDER
下载PDF
Structural analysis on cutting notch of tea stalk by X-ray micro-computed tomography
9
作者 Zhe Du Yongguang Hu +2 位作者 Wenye Wu Yongzong Lu Noman Ali Buttar 《Information Processing in Agriculture》 EI 2020年第2期242-248,共7页
Quantitative analysis on cutting notch of tea stalk is one method to better understand shear resistance and mechanical properties of the stalk,which could improve cutting performance and efficiency for tea harvesting.... Quantitative analysis on cutting notch of tea stalk is one method to better understand shear resistance and mechanical properties of the stalk,which could improve cutting performance and efficiency for tea harvesting.Optimal design of the cutter might be achieved through structural analysis of cutting notch by X-ray micro-computed tomography(micro-CT).The third inter-node of the stalks were sampled and scanned by micro-CT after they were cut at different cutting depths(0.7,1.5,2.3 mm)and cutting edge angles of cutter(30,35,40).The structural change of the cutting notch and cutting force was observed.Grey-scale histogram analysis and bimodal segmentation method were used to extract the information about cutting notch from 2D slice images.A 3D model of the stalk was established with reconstruction and volume rendering.Besides,maximum crosssectional area ratio of cutting notch(MCSARCN)and volume ratio of cutting notch(VRCN)were calculated.The results show that MCSARCN and VRCN had a closely relationship with the cutting force,cutting depth and cutting edge angle according to 3D tomographic images and 2D slice images.Both MCSARCN and VRCN increased with cutting depth,despite of cutting edge angle.For cutting edge angle of 30,35and 40at different cutting depths,MCSARCN increased from 4.89%to 9.47%,from 8.51%to 22.83%and from 4.30%to 16.87%,respectively.Meanwhile,VRCN increased from 1.59%to 2.13%,from 2.98%to 5.76%and from 3.04%to 5.01%,respectively.When cutting depth was 1.5 mm,cutting force increased but VRCN present a decreased trend with cutting edge angle.X-ray micro-CT could be used to analyze the structure on cutting notch of tea stalks which is helpful in optimizing the structural parameters of the cutter. 展开更多
关键词 Tea stalk Cutting notch X-ray micro-computed tomography Structural analysis
原文传递
Anti-catabolic effect of caffeic acid phenethyl ester, an active component of honeybee propolis on bone loss in ovariectomized mice: a micro-computed tomography study and histological analysis
10
作者 Duan Wangping Wang Qing +5 位作者 Li Fang Xiang Chuan Zhou Lin Xu Jiake Feng Haotian Wei Xiaochun 《Chinese Medical Journal》 SCIE CAS CSCD 2014年第22期3932-3936,共5页
Background Osteoporosis (OP) is a common bone disease,which adversely affects life quality.Effective treatments are necessary to combat both the loss and fracture of bone.Recent studies indicated that caffeic acid p... Background Osteoporosis (OP) is a common bone disease,which adversely affects life quality.Effective treatments are necessary to combat both the loss and fracture of bone.Recent studies indicated that caffeic acid phenethyl ester (CAPE) is a natural chemical compound from honeybee propolis which is capable of attenuating osteoclastogenesis and bone resorption.Therefore,this study aimed to investigate the effect of CAPE on bone loss in OP mice using micro-computed tomography (CT) and histology.Methods Eighteen mice were prepared and evenly divided into three groups.The six mice in the sham+PBS group did not undergo ovariectomy and were intraperitoneally injected with PBS during the curing period.Twelve mice were ovariectomized (OVX) to induce OP.Six of them in the OVX+CAPE group were intraperitoneally injected with 0.5 mg/kg CAPE twice per week for 4 weeks after ovariectomy.The other six OVX mice in OVX+PBS group were treated with PBS.All the mice were sacrificed 4 weeks after ovariectomy.The tibias were bilaterally excised for micro-CT scan and histological analysis.The Mann-Whitney U test was used to test the statistical differences among groups.Results Bone loss occurred in OVX mice.Compared with the sham+PBS group,mice in the OVX+PBS group exhibited a significant decrease in bone mineral density (BMD,P <0.05),bone volume fraction (BV/TV,P <0.01),trabecular thickness (Tb.Th,P <0.05),and trabecular number (Tb.N,P <0.01),as well as a non-insignificant increase in the number of osteoclasts (N.Oc/B.Pm).With CAPE treatment,the microarchitecture of the tibial metaphyses was significantly improved with a reduction of osteoclast formation.Compared with the OVX+PBS group,BV/TV in the OVX+CAPE group was significantly increased by 33.9% (P <0.05).Conclusion CAPE therapy results in the protection of bone loss induced by OVX. 展开更多
关键词 caffeic acid phenethyl ester osteoporosis bone loss micro-computed tomography
原文传递
Influence of inter-grain cementation stiffness on the effective elastic properties of porous Bentheim sandstone
11
作者 Bin Chen Jiansheng Xiang John-Paul Latham 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2023年第3期573-583,共11页
Effective elastic properties of porous media are known to be significantly influenced by porosity.In this paper,we investigated the influence of another critical factor,the inter-grain cementation stiffness,on the eff... Effective elastic properties of porous media are known to be significantly influenced by porosity.In this paper,we investigated the influence of another critical factor,the inter-grain cementation stiffness,on the effective elastic properties of a granular porous rock(Bentheim sandstone)using an advanced numerical workflow with realistic rock microstructure and a theoretical model.First,the disparity between the experimentally tested elastic properties of Bentheim sandstone and the effective elastic properties predicted by empirical equations was analysed.Then,a micro-computed tomography(CT)-scan based approach was implemented with digital imaging software AVIZO to construct the 3D(three-dimensional)realistic microstructure of Bentheim sandstone.The microstructural model was imported to a mechanics solver based on the 3D finite element model with inter-grain boundaries modelled by cohesive elements.Loading simulations were run to test the effective elastic properties for different shear and normal intergrain cementation stiffness.Finally,a relation between the macroscale Young’s modulus and inter-grain cementation stiffness was derived with a theoretical model which can also account for porosity explicitly.Both the numerical and theoretical results indicate the influence of the inter-grain cementation stiffness,on the effective elastic properties is significant for porous sandstone.The calibrated normal and shear stiffnesses at the inter-grain boundaries are 1.2×10^(5) and 4×10^(4) GPa/m,respectively. 展开更多
关键词 Porous sandstone Cohesive finite element model Grain-based model Rock microstructure micro-computed tomography(CT)
下载PDF
Three-Point Bending Test and Crack Detection by Acoustic Emission on Different Spring Steel Wires with Different Crystallographic Textures
12
作者 Mathias Lorenz Mohammed Salih +4 位作者 Daniela Schwerdt Nowfal Al-Hamdany Emad Maawad Norbert Schell Eckehard Müller 《材料科学与工程(中英文A版)》 2023年第3期53-67,共15页
In the production of compression springs,high forming velocities and grades of deformation during winding and setting may induce cracks that can lead to failure causing risks of an accident and damage.The AE(acoustic ... In the production of compression springs,high forming velocities and grades of deformation during winding and setting may induce cracks that can lead to failure causing risks of an accident and damage.The AE(acoustic emission)technology,a non-destructive monitoring method,can detect acoustic signals reflected from cracks.To establish this method in the production of technical springs,it was necessary,to find out whether the AE signal is influenced by material properties,phase fractions distribution from tempered martensite,retained austenite,and microstructure including crystallographic texture.In addition,it was investigated to what extent the detected AE signal can be useful to separate between an actual crack and other material responses.Within an in-situ three-point bending test with the AE technology,macro-and micro-crack-typical AE signals were detected for five different spring steel wires(SH,VDSiCr,and FDSiCr according to EN-10270-1 and EN-10270-2).The relative energy related to the initiation,propagation,and growth of cracks caused by mechanical stress was measured using a piezoelectric sensor.If a crack AE signal appeared for the first time,the bending tests were stopped immediately.The results show that the frequency spectrum combined with the intensity of the acoustic signals generated during crack growth depends on the material properties and the crystallographic texture.Furthermore,it could be shown that it is possible to differentiate between micro-crack-typical AE signals and other signals that result from different material responses. 展开更多
关键词 Technical springs AE analysis micro-computer tomography TEXTURE
下载PDF
Dental and periodontal phenotype in sclerostin knockout mice 被引量:7
13
作者 Ulrike Kuchler Uwe Y Schwarze +4 位作者 Toni Dobsak Patrick Heimel Dieter D Bosshardt Michaela Kneissel Reinhard Gruber 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第2期70-76,共7页
Sclerostin is a Wnt signalling antagonist that controls bone metabolism. Sclerostin is expressed by osteocytes and cementocytes; however, its role in the formation of dental structures remains unclear. Here, we analys... Sclerostin is a Wnt signalling antagonist that controls bone metabolism. Sclerostin is expressed by osteocytes and cementocytes; however, its role in the formation of dental structures remains unclear. Here, we analysed the mandibles of sclerostin knockout mice to determine the influence of sclerostin on dental structures and dimensions using histomorphometry and micro-computed tomography (μCT) imaging, μCT and histomorphometric analyses were performed on the first lower molar and its surrounding structures in mice lacking a functional sclerostin gene and in wild-type controls, pCT on six animals in each group revealed that the dimension of the basal bone as well as the coronal and apical part of alveolar part increased in the sclerostin knockout mice. No significant differences were observed for the tooth and pulp chamber volume. Descriptive histomorphometric analyses of four wild-type and three sclerostin knockout mice demonstrated an increased width of the cementum and a concomitant moderate decrease in the periodontal space width. Taken together, these results suggest that the lack of sclerostin mainly alters the bone and cementum phenotypes rather than producing abnormalities in tooth structures such as dentin. 展开更多
关键词 alveolar bone micro-computed tomography mouse PERIODONTIUM SCLEROSTIN TOOTH
下载PDF
Three-dimensional analysis of the physiological foramen geometry of maxillary and mandibular molars by means of micro-CT 被引量:4
14
作者 Thomas Gerhard Wolf Frank Paqué +2 位作者 Michael Sven Patyna Brita Willershausen Benjamín Briseno-Marroquín 《International Journal of Oral Science》 SCIE CAS CSCD 2017年第3期151-157,共7页
The aim of this study was to investigate the physiological foramen diameter, shape and distance between physiological and anatomical apex of maxillary and mandibular first and second molars. Accurate knowledge of the ... The aim of this study was to investigate the physiological foramen diameter, shape and distance between physiological and anatomical apex of maxillary and mandibular first and second molars. Accurate knowledge of the physiological foramina morphology; thus, inherent mechanical shaping technical hindrances, is decisive when taking the corresponding root canal final preparation decision. The morphological dimensions of a total of 1 727 physiological foramina were investigated by means of micro-computed tomography. Mean narrow and wide (to a high number, oval) diameters of the physiological foramen were 0.24, 0.22 and 0.33 mm and 0.33, 0.31 and 0.42 mm in mesiobuccal (MB), distobuccal (DB) and palatal (P) roots in maxillary first molars; 0.24, 0.22 and 0.33 mm and 0.41, 0.33 and 0.44 in MB, DB, and P roots in maxillary second molars. Mandibular first molars showed mean narrow and wide diameters of 0.24 and 0.30 mm and of 0.39 and 0.46 mm in mesial (M) and distal (D) roots; second mandibular molars showed 0.25 and 0.31 mm and 0.47 mm in M and D roots. The mean distance between the physiological foramina and anatomical apex was 0.82, 0.81 and 1.02 mm and 0.54, 0.43 and 0.63 mm in MB, DB and P roots of the maxillary first and second molars, respectively. A mean distance of 0.95 mm (M) and 1.05 mm (D) in the first and 0.78 mm (M) and 0.81 mm (D) in the second mandibular molars was observed. Based on the results obtained, assumable recommendations for final preparation size of the physiological foramen were calculated. However, when taking into consideration, the resulting standard deviations of marginal errors must be cautiously considered when taking a final decision in clinical endodontic treatment. 展开更多
关键词 apical constriction final apical file maxillary and mandibular molars morphology micro-computed tomography physiological foramen
下载PDF
Optimization of taste-masking on ibuprofen microspheres with selected structure features 被引量:3
15
作者 Wei Qin Yuanzhi He +8 位作者 Zhen Guo Liu Zhang Li Wu Xianzhen Yin Shailendra Shakya Abi Maharjan Yan Tang Weifeng Zhu Jiwen Zhang 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2019年第2期174-182,共9页
The microsphere was a primary particulate system for taste-masking with unique structural features defined by production process. In this article, ibuprofen lipid microspheres of octadecanol and glycerin monostearate ... The microsphere was a primary particulate system for taste-masking with unique structural features defined by production process. In this article, ibuprofen lipid microspheres of octadecanol and glycerin monostearate were prepared to mask the undesirable taste of ibuprofen via three kinds of spray congealing processes, namely, air-cooling, water-cooling and citric acid solution-cooling. The stereoscopic and internal structures of ibuprofen microspheres were quantitatively analyzed by synchrotron radiation X-ray micro-computed tomography(SR-μCT) to establish the relationship between the preparation process and microsphere architectures. It was found that the microstructure and morphology of the microspheres were significantly influenced by preparation processes as the primary factors to determine the release profiles and taste-masking effects. The sphericity of ibuprofen microspheres congealed in citric acid solution was higher than that of other two and its morphology was more regular than that being congealed in air or distilled water, and the contact angles between congealing media and melted ibuprofen in octadecanol and glycerin monostearate well demonstrated the structure differences among microspheres of three processes which controlled the release characteristics of the microspheres. The structure parameters like porosity, sphericity, and radius ratio from quantitative analysis were correlated well with drug release behaviors. The results demonstrated that the exterior morphology and internal structure of microspheres had considerable influences on the drug release behaviors as well as taste-masking effects. 展开更多
关键词 IBUPROFEN MICROSPHERE SPRAY congealing Internal structure SYNCHROTRON radiation X-ray micro-computed tomography
下载PDF
Application of custom anatomy-based nerve conduits on rabbit sciatic nerve defects: in vitro and in vivo evaluations 被引量:1
16
作者 Yamuhanmode·Alike Maimaiaili·Yushan +6 位作者 Ajimu·Keremu Alimujiang·Abulaiti Zhen-Hui Liu Wei Fu Li-Wei Yan Aihemaitijiang·Yusufu Qing-Tang Zhu 《Neural Regeneration Research》 SCIE CAS CSCD 2019年第12期2173-2182,共10页
The intermingling of regenerated nerve fibers inside nerve grafts is the main reason for mismatched nerve fibers. This is one of the key factors affecting limb function recovery after nerve injury. Previous research h... The intermingling of regenerated nerve fibers inside nerve grafts is the main reason for mismatched nerve fibers. This is one of the key factors affecting limb function recovery after nerve injury. Previous research has shown that the accuracy of axon regeneration can be improved by a bionic structural implant. To this aim, iodine and freeze-drying high-resolution micro-computed tomography was performed to visualize the 3D topography of the New Zealand rabbit sciatic nerve (25 mm). A series of 1-, 2-, 3-, and 4-custom anatomy-based nerve conduits (CANCs) were fabricated based on the anatomical structure of the nerve fascicle. The match index, luminal surface, and mechanical properties of CANCs were evaluated before implanting in a 10-mm gap of the sciatic nerve. Recovery was evaluated by histomorphometric analyses, electrophysiological study, gastrocnemius muscle weight recovery ratio, and behavioral assessments at 12 and 24 weeks postoperatively. The accuracy of nerve regeneration was determined by changes in fluorescence-labeled profile number during simultaneous retrograde tracing. Our results showed that the optimal preprocessing condition for high-resolution micro-computed tomography visualization was treatment of the sciatic nerve with 40% Lugol’s solution for 3 days followed by lyophilization for 2 days. In vitro experiments demonstrated that the match index was highest in the 3-CANC group, followed by the 2-, 1-, and 4-CANC groups. The luminal surface was lowest in the 1-CANC group. Mechanical properties (transverse compressive and bending properties) were higher in the 3- and 4-CANC groups than in the 1-CANC group. In vivo experiments demonstrated that the recovery (morphology of regenerated fibers, compound muscle action potential, gastrocnemius muscle weight recovery ratio, pain-related autotomy behaviors, and range of motion) in the 3-CANC group was superior to the other CANC groups, and achieved the same therapeutic effect as the autograft. The simultaneous retrograde tracing results showed that the percentages of double-labeled profiles of the 2-, 3-, and 4-CANC groups were comparatively lower than that of the 1-CANC group, which indicates that regenerated nerve fascicles were less intermingled in the 2-, 3-, and 4-CANC groups. These findings demonstrate that the visualization of the rabbit sciatic nerve can be achieved by iodine and freeze-drying high-resolution micro-computed tomography, and that this method can be used to design CANCs with different channels that are based on the anatomical structure of the nerve. Compared with the 1-CANC, 3-CANC had a higher match index and luminal surface, and improved the accuracy of nerve regeneration by limiting the intermingling of the regenerated fascicles. All procedures were approved by the Animal Care and Use Committee, Xinjiang Medical University, China on April 4, 2017 (ethics approval No. IACUC20170315-02). 展开更多
关键词 NERVE REGENERATION NERVE conduits mismatch iodine and FREEZE-DRYING high-resolution micro-computed tomography bio-mimic CUSTOM RABBIT SCIATIC NERVE in vitro in vivo neural REGENERATION
下载PDF
Calcitonin and vitamin D3 have high therapeutic potential for improving diabetic mandibular growth 被引量:1
17
作者 Mona A Abbassy Ippei Watari +2 位作者 Ahmed S Bakry Takashi Ono Ali H Hassan 《International Journal of Oral Science》 SCIE CAS CSCD 2016年第1期39-44,共6页
The goal of this study was to assess the effect of the intermittent combination of an antiresorptive agent (calcitonin) and an anabolic agent (vitamin D3) on treating the detrimental effects of Type 1 diabetes mel... The goal of this study was to assess the effect of the intermittent combination of an antiresorptive agent (calcitonin) and an anabolic agent (vitamin D3) on treating the detrimental effects of Type 1 diabetes mellitus (DM) on mandibular bone formation and growth. Forty 3-week-old male Wistar rats were divided into four groups: the control group (normal rats), the control C+D group (normal rats injected with calcitonin and vitamin D3), the diabetic C+D group (diabetic rats injected with calcitonin and vitamin D3) and the diabetic group (uncontrolled diabetic rats). An experimental DM condition was induced in the male Wistar rats in the diabetic and diabetic C+ D groups using a single dose of 60 mg.kg-1 body weight of streptozotocin. Calcitonin and vitamin D3 were simultaneously injected in the rats of the control C+D and diabetic C+D groups. All rats were killed after 4 weeks, and the right mandibles were evaluated by micro-computed tomography and histomorphometric analysis. Diabetic rats showed a significant deterioration in bone quality and bone formation (diabetic group). By contrast, with the injection of calcitonin and vitamin D3, both bone parameters and bone formation significantly improved (diabetic C+ D group) (P 〈 0.05). These findings suggest that these two hormones might potentially improve various bone properties. 展开更多
关键词 type 1 diabetes mellitus mandibular bone structure mandibular bone formation micro-computed tomography BONE HISTOMORPHOMETRY
下载PDF
Trabecular bone deterioration at the greater trochanter ol mice with unilateral obstructive nephropathy 被引量:1
18
作者 Sa-Sa Gu Yan Zhang +3 位作者 Xi Chen Teng-Yue Diao Yoseph Gebru Man-Sau Wong 《Asian Journal of Andrology》 SCIE CAS CSCD 2013年第4期564-566,I0011,I0012,共5页
Our previous study showed the early molecular responses of bone in response to obstructive nephropathy in a unilateral ureteral obstruction (UUO) mouse model. Here, we addressed the changes in trabecular bone proper... Our previous study showed the early molecular responses of bone in response to obstructive nephropathy in a unilateral ureteral obstruction (UUO) mouse model. Here, we addressed the changes in trabecular bone properties at greater trochanter, the proximal and the distal metaphysis of femur in UUO mice. The male mice were subjected to UUO (n= 10) or sham operation (n= 10). All mice were killed on day 7 after the surgical operation. The micro-computed tomography (micro-CT) analysis for different femoral trabecular bone sites demonstrated pathological alterations of trabecular bone mass and micro-networks at greater trochanter as shown by decreases in bone mineral density/bone volume (P〈O.05) and trabecular number (P〈O.05) and increases in trabecular separation (P〈O.01) and bone surface/bone volume (P〈O.05) in UUO mice. The present study demonstrates that UUO-induced unilateral obstructivenephropathy has markedly detrimental effects on the trabecular trochanter of the femur. 展开更多
关键词 BONE FEMUR micro-computed tomography (micro-CT) trochanter unilateral ureteral obstruction (UUO)
下载PDF
A robust methodology for the quantitative assessmentof the rat jawbone microstructure
19
作者 Marissa Chatterjee Fernanda Faot +3 位作者 Cassia Correa Joke Duyck Ignace Naert Katleen Vandamme 《International Journal of Oral Science》 SCIE CAS CSCD 2017年第2期87-94,共8页
Micro-computed tomography can be applied for the assessment of the micro-architectural characteristics of the cortical and trabecular bones in either physiological or disease conditions. However, reports often lack a ... Micro-computed tomography can be applied for the assessment of the micro-architectural characteristics of the cortical and trabecular bones in either physiological or disease conditions. However, reports often lack a detailed description of the methodological steps used to analyse these images, such as the volumes of interest, the algorithms used for image filtration, the approach used for image segmentation, and the bone parameters quantified, thereby making it difficult to compare or reproduce the studies. This study addresses this critical need and aims to provide standardized assessment and consistent parameter reporting related to quantitative jawbone image analysis. Various regions of the rat jawbones were screened for their potential for standardized micro-computed tomography analysis. Furthermore, the volumes of interest that were anticipated to be most susceptible to bone structural changes in response to experimental interventions were defined. In the mandible, two volumes of interest were selected, namely, the condyle and the trabecular bone surrounding the three molars. In the maxilla, the maxillary tuberosity region and the inter-radicular septum of the second molar were considered as volumes of interest. The presented protocol provides a standardized and reproducible methodology for the analysis of relevant jawbone volumes of interest and is intended to ensure global, accurate, and consistent reporting of its morphometry. Furthermore, the proposed methodology has potential, as a variety of rodent animal models would benefit from its implementation. 展开更多
关键词 bone microarchitecture JAWBONE METHODOLOGY micro-computed tomography RAT
下载PDF
Effects of methotrexate on collagen-induced arthritis in male Wistar rats
20
作者 Jin Seok Kang 《The Journal of Biomedical Research》 CAS CSCD 2019年第4期244-249,共6页
To evaluate the effect of methotrexate on collagen-induced arthritis,micro-computed tomography(micro-CT)and histopathological analyses were used in male Wistar rats.Rats were divided randomly into three groups.Group 1... To evaluate the effect of methotrexate on collagen-induced arthritis,micro-computed tomography(micro-CT)and histopathological analyses were used in male Wistar rats.Rats were divided randomly into three groups.Group 1 was treated with 0.9% saline,and groups 2 and 3 were boosted with type II collagen.From day 21 to 42,groups 1 and 2 were orally treated with 0.9% saline and group 3 was orally treated with 1.5 mg/kg methotrexate.All rats were sacrificed at day 42 after the first collagen treatment.Micro-CT analyses showed bony parameters,such as bone volume and trabecular number,were decreased in group 2 compared to group 1,and these parameters were recovered in group 3.Histopathological examination and pathological parameter scoring showed that the knee joints of rats in group 2 had severe joint destruction,showing cartilage and bone erosion,enlarged cavities with inflammatory cell infiltration and activation of synovial fibroblasts.By contrast,these changes were reduced in group 3.Taken together,methotrexate treatment showed therapeutic potential in male rat collageninduced arthritis model,and micro-CT analysis and histopathological tools could be integrated to assess the quantification/qualification of arthritic lesions. 展开更多
关键词 ARTHRITIS rat COLLAGEN micro-computed TOMOGRAPHY HISTOPATHOLOGY