Biological specimens are fundamental for taxonomy and flora/fauna research.More importantly,they also play crucial roles in recording environmental impacts on morphology and behavior,which is vital for biodiversity re...Biological specimens are fundamental for taxonomy and flora/fauna research.More importantly,they also play crucial roles in recording environmental impacts on morphology and behavior,which is vital for biodiversity research and conservation.However,there are few systematic studies on the patterns and drivers of bird specimen number at regional scales.This study is the first attempt to examine the relationships between bird specimen number and species traits as well as climate niche breadth in China,aiming to answer two questions:1)how do species’temperature niche breadth and precipitation niche breadth influence specimen number?2)which trait is most associated with bird specimen number?The associations between bird specimen number and explanatory variables were examined using ordinary least squares,generalized linear models,phylogenetic generalized linear mixed models,and multiple comparisons.The results showed that Muscicapidae was the family with the highest specimen number,and Passeriformes was the order with the highest specimen number.Bird specimen number significantly increased with larger temperature niche breadth and precipitation niche breadth.Specimen number was also positively associated with geographic range size,habitat specificity,hunting vulnerability and clutch size,but negatively associated with body size.These findings suggest that future bird specimen collection should pay more attention to birds with limited ecological niches,large body sizes,and small clutch sizes.This research enhances the use of bird specimen data to study and preserve biodiversity.展开更多
The mechanical properties of residual coal pillars under the influence of upward mining disturbances significantly affect the safety of residual mining activities on working faces.This study conducted low-frequency di...The mechanical properties of residual coal pillars under the influence of upward mining disturbances significantly affect the safety of residual mining activities on working faces.This study conducted low-frequency disturbance dynamic uniaxial compression tests on coal specimens using a self-developed dynamic-static load coupling electro-hydraulic servo system,and studied the strength evolutions,surface deformations,acoustic emission(AE)characteristic parameters,and the failure modes of coal specimens with different static preloading levels were studied.The disturbance damage is positively correlated with the coal specimen static preload level.Specifically,the cumulative AE count rates of the initial accelerated damage stage for the coal specimens with static preloading level of 60%and 70%of the uniaxial compressive strength(UCS)were 2.66 and 3.19 times that of the 50%UCS specimens,respectively.Macroscopically,this behaviour manifested as a decrease in the compressive strength,and the mean strengths of the disturbance-damaged coal specimens with 60%and 70%of UCS static preloading decreased by 8.53%and 9.32%,respectively,compared to those of the specimens under pure static loading.The crack sources,such as the primary fissures,strongly control the dynamic response of the coal specimen.The difference between the dynamic responses of the coal specimens and that of dense rocks is significant.展开更多
Many different factors,such as species traits,socio-economic factors,geographical and environmental factors,can lead to specimen collection preference.This study aims to determine whether grassland specimen collection...Many different factors,such as species traits,socio-economic factors,geographical and environmental factors,can lead to specimen collection preference.This study aims to determine whether grassland specimen collection in China is preferred by species traits(i.e.,plant height,flowering and fruiting period),environmental range(i.e.,the temperature and precipitation range)and geographical range(i.e.,distribution range and altitudinal range).Ordinary least squares models and phylogenetic generalized linear mixed models were used to analyze the relationships between specimen number and the explanatory variables.Random Forest models were then used to find the most parsimonious multivariate model.The results showed that interannual variation in specimen number between 1900 and 2020 was considerable.Specimen number of these species in southeast China was notably lower than that in northwest China.Environmental range and geographical range of species had significant positive correlations with specimen number.In addition,there were relatively weak but significant associations between specimen number and species trait(i.e.,plant height and flowering and fruiting period).Random Forest models indicated that distribution range was the most important variable,followed by flowering and fruiting period,and altitudinal range.These findings suggest that future floristic surveys should pay more attention to species with small geographical range,narrow environmental range,short plant height,and short flowering and fruiting period.The correction of specimen collection preference will also make the results of species distribution model,species evolution and other works based on specimen data more accurate.展开更多
To compare finite element analysis(FEA)predictions and stereovision digital image correlation(StereoDIC)strain measurements at the same spatial positions throughout a region of interest,a field comparison procedure is...To compare finite element analysis(FEA)predictions and stereovision digital image correlation(StereoDIC)strain measurements at the same spatial positions throughout a region of interest,a field comparison procedure is developed.The procedure includes(a)conversion of the finite element data into a triangular mesh,(b)selection of a common coordinate system,(c)determination of the rigid body transformation to place both measurements and FEA data in the same system and(d)interpolation of the FEA nodal information to the same spatial locations as the StereoDIC measurements using barycentric coordinates.For an aluminum Al-6061 double edge notched tensile specimen,FEA results are obtained using both the von Mises isotropic yield criterion and Hill’s quadratic anisotropic yield criterion,with the unknown Hill model parameters determined using full-field specimen strain measurements for the nominally plane stress specimen.Using Hill’s quadratic anisotropic yield criterion,the point-by-point comparison of experimentally based full-field strains and stresses to finite element predictions are shown to be in excellent agreement,confirming the effectiveness of the field comparison process.展开更多
BACKGROUND Natural orifice specimen extraction surgery(NOSES)has emerged as a promising alternative compared to conventional laparoscopic-assisted total gastrectomy(LATG)for treating gastric cancer(GC).However,evidenc...BACKGROUND Natural orifice specimen extraction surgery(NOSES)has emerged as a promising alternative compared to conventional laparoscopic-assisted total gastrectomy(LATG)for treating gastric cancer(GC).However,evidence regarding the efficacy and safety of NOSES for GC surgery is limited.This study aimed to compare the safety and feasibility,in addition to postoperative complications of NOSES and LATG.METHODS Dual circular staplers were used in Roux-en-Y digestive tract reconstruction for transvaginal specimen extraction LATG,and its outcomes were compared with LATG in a cohort of 51 GC patients with tumor size≤5 cm.The study was conducted from May 2018 to September 2020,and patients were categorized into the NOSES group(n=22)and LATG group(n=29).Perioperative parameters were compared and analyzed,including patient and tumor characteristics,postoperative outcomes,and anastomosis-related complications,postoperative hospital stay,the length of abdominal incision,difference in tumor type,postoperative complications,and postoperative survival.RESULTS Postoperative exhaust time,operation duration,mean postoperative hospital stay,length of abdominal incision,number of specific staplers used,and Brief Illness Perception Questionnaire score were significant in both groups(P<0.01).In the NOSES group,the postoperative time to first flatus,mean postoperative hospital stay,and length of abdominal incision were significantly shorter than those in the LATG group.Patients in the NOSES group had faster postoperative recovery,and achieved abdominal minimally invasive incision that met aesthetic requirements.There were no significant differences in gender,age,tumor type,postoperative complications,and postoperative survival between the two groups.CONCLUSION The application of dual circular staplers in Roux-en-Y digestive tract reconstruction combined with NOSES gastrectomy is safe and convenient.This approach offers better short-term outcomes compared to LATG,while long-term survival rates are comparable to those of conventional laparoscopic surgery.展开更多
Using a scanning electron microscope (SEM) in the back-scattered electron (BSE) mode the composition of multi-element specimens may be determined based on the strong dependence of emission coefficient η on the averag...Using a scanning electron microscope (SEM) in the back-scattered electron (BSE) mode the composition of multi-element specimens may be determined based on the strong dependence of emission coefficient η on the average atomic number of elements Z. The output video signal of the usual BSE detectors is produced from their sensors, and the larger proportion of high-energy electrons with modified spectrum is added. Since η = is/ip (is and ip currents of specimen and probe), better accuracy must be achieved by direct measurements those currents on the specimen surface. Here, an experimental model of a current detector for a presented specimen is described. The cage is mounted on the carousel of the moving specimen stage. The input of the preamplifier is connected to the specimen holder in the form of a disk, the diameter of which is 12 mm. When the probe along its surface scanned, the input potential begins to pulsate with a negative polarity. The output of this preamplifier is connected to a small light-emitting diode, which creates intensity-modulated radiation in the chamber. Thus created the light video signal will be picked up by the photomultiplier of the E-T detector. The modes of true SE and BSE are set by applying tens bias volts of various polarities to the specimens or the cage itself.展开更多
Objective:To analyze the application effect of feedforward control in outpatient blood specimen management.Methods:1,200 patients who had their venous blood collected in outpatient phlebotomy room of our hospital'...Objective:To analyze the application effect of feedforward control in outpatient blood specimen management.Methods:1,200 patients who had their venous blood collected in outpatient phlebotomy room of our hospital's outpatient clinic from January 2021 to April 2021 were selected as study subjects and divided into 600 cases in the control group and 600 cases in the observation group.The two groups of patients were compared in terms of their satisfaction with the staff,the efficiency of the nurses and the quality of nursing care,turnaround time before specimen analysis,the rejection rate of the blood specimens,and the time of result reporting.Results:After the implementation of feedforward control,patients'satisfaction with staff,nurses work efficiency and quality of care,turnaround time before specimen analysis,specimen rejection rate,and result reporting time in the observation group were significantly higher than those in the control group(P<0.05).Conclusion:The application of feedforward control in the management of outpatient blood specimens has significant effect,which effectively improves patients'satisfaction,enhances the efficiency of nurses and the quality of nursing care,shortens the turnaround time of specimens before analysis and the reporting time of results,and reduces the rejection rate of specimens.展开更多
BACKGROUND Robotic resection using the natural orifice specimen extraction surgery I-type F method(R-NOSES I-F)is a novel minimally invasive surgical strategy for the treatment of lower rectal cancer.However,the curre...BACKGROUND Robotic resection using the natural orifice specimen extraction surgery I-type F method(R-NOSES I-F)is a novel minimally invasive surgical strategy for the treatment of lower rectal cancer.However,the current literature on this method is limited to case reports,and further investigation into its safety and feasibility is warranted.AIM To evaluate the safety and feasibility of R-NOSES I-F for the treatment of low rectal cancer.METHODS From September 2018 to February 2022,206 patients diagnosed with low rectal cancer at First Affiliated Hospital of Nanchang University were included in this retrospective analysis.Of these patients,22 underwent R-NOSES I-F surgery(RNOSES I-F group)and 76 underwent conventional robotic-assisted low rectal cancer resection(RLRC group).Clinicopathological data of all patients were collected and analyzed.Postoperative outcomes and prognoses were compared between the two groups.Statistical analysis was performed using SPSS software.RESULTS Patients in the R-NOSES I-F group had a significantly lower visual analog score for pain on postoperative day 1(1.7±0.7 vs 2.2±0.6,P=0.003)and shorter postoperative anal venting time(2.7±0.6 vs 3.5±0.7,P<0.001)than those in the RLRC group.There were no significant differences between the two groups in terms of sex,age,body mass index,tumor size,TNM stage,operative time,intrao-perative bleeding,postoperative complications,or inflammatory response(P>0.05).Postoperative anal and urinary functions,as assessed by Wexner,low anterior resection syndrome,and International Prostate Symptom Scale scores,were similar in both groups(P>0.05).Long-term follow-up revealed no significant differences in the rates of local recurrence and distant metastasis between the two groups(P>0.05).CONCLUSION R-NOSES I-F is a safe and effective minimally invasive procedure for the treatment of lower rectal cancer.It improves pain relief,promotes gastrointestinal function recovery,and helps avoid incision-related complications.展开更多
To explore ways to improve the accuracy of quantitative analysis of samples in the micrometer to nanometer range of magnitudes,we adopted analytical transmission electron microscopy(AEM/EDS)for qualitative and quantit...To explore ways to improve the accuracy of quantitative analysis of samples in the micrometer to nanometer range of magnitudes,we adopted analytical transmission electron microscopy(AEM/EDS)for qualitative and quantitative analysis of pyrite materials.Additionally,the k factor of pyrite is calculated experimentally.To develop an appropriate non-standard quantitative analysis model for pyrite materials,the experimentally calculated k factor is compared with that estimated from the non-standard quantitative analytical model of the instrument software.The experimental findings demonstrate that the EDS attached to a TEM can be employed for precise quantitative analysis of micro-and nanoscale regions of pyrite materials.Furthermore,it serves as a reference for improving the results of the EDS quantitative analysis of other sulfides.展开更多
The rejected specimens from the Emergency Department of the Center of Clinical Laboratory from January 1,2022 to January 1,2023 were analyzed to reduce the specimen rejection rates and to improve the quality of inspec...The rejected specimens from the Emergency Department of the Center of Clinical Laboratory from January 1,2022 to January 1,2023 were analyzed to reduce the specimen rejection rates and to improve the quality of inspection.The results showed that there were 1488 samples of rejected specimens and the non-conforming rate was 0.58%.The departments involved were mainly the Emergency Department,the Hematology Department,the Cardiology Department,the Intensive Care Department,and the Brain Surgery Department.Among the reasons for rejection,blood hemolysis accounted for 43.15%,blood coagulation accounted for 26.61%,and the rate of insufficient specimens was 17.14%.Among them,the sample rejection rate for arterial blood gas analysis was the highest,which accounted for 1.74%;followed by specimens for coagulation test,which was 1.18%.These results indicate the main reason for producing rejected specimens is mainly due to not following the standard operating procedure.Specimen rejection can largely be avoided if the standards for specimen collection are strictly followed.展开更多
基金supported by the Natural Science Foundation of Inner Mongolia,China(2023JQ01)the National Key R&D Program of China(2019YFA0607103)+2 种基金the Central Government Guides Local Science and Technology Development Fund Projects(2022ZY0224)the Open Project Program of’Ministry of Education Key Laboratory of Ecology and Resources Use of the Mongolian Plateau(KF2023003)’the Major Science and Technology Project of Inner Mongolia Autonomous Region:Monitoring,Assessment and Early Warning Technology Research of Biodiversity in Inner Mongolia(2021ZD0011)。
文摘Biological specimens are fundamental for taxonomy and flora/fauna research.More importantly,they also play crucial roles in recording environmental impacts on morphology and behavior,which is vital for biodiversity research and conservation.However,there are few systematic studies on the patterns and drivers of bird specimen number at regional scales.This study is the first attempt to examine the relationships between bird specimen number and species traits as well as climate niche breadth in China,aiming to answer two questions:1)how do species’temperature niche breadth and precipitation niche breadth influence specimen number?2)which trait is most associated with bird specimen number?The associations between bird specimen number and explanatory variables were examined using ordinary least squares,generalized linear models,phylogenetic generalized linear mixed models,and multiple comparisons.The results showed that Muscicapidae was the family with the highest specimen number,and Passeriformes was the order with the highest specimen number.Bird specimen number significantly increased with larger temperature niche breadth and precipitation niche breadth.Specimen number was also positively associated with geographic range size,habitat specificity,hunting vulnerability and clutch size,but negatively associated with body size.These findings suggest that future bird specimen collection should pay more attention to birds with limited ecological niches,large body sizes,and small clutch sizes.This research enhances the use of bird specimen data to study and preserve biodiversity.
基金Projects(51925402,52334005,52304094)supported by the National Natural Science Foundation of ChinaProject(20201102004)supported by the Shanxi Science and Technology Major Project,China。
文摘The mechanical properties of residual coal pillars under the influence of upward mining disturbances significantly affect the safety of residual mining activities on working faces.This study conducted low-frequency disturbance dynamic uniaxial compression tests on coal specimens using a self-developed dynamic-static load coupling electro-hydraulic servo system,and studied the strength evolutions,surface deformations,acoustic emission(AE)characteristic parameters,and the failure modes of coal specimens with different static preloading levels were studied.The disturbance damage is positively correlated with the coal specimen static preload level.Specifically,the cumulative AE count rates of the initial accelerated damage stage for the coal specimens with static preloading level of 60%and 70%of the uniaxial compressive strength(UCS)were 2.66 and 3.19 times that of the 50%UCS specimens,respectively.Macroscopically,this behaviour manifested as a decrease in the compressive strength,and the mean strengths of the disturbance-damaged coal specimens with 60%and 70%of UCS static preloading decreased by 8.53%and 9.32%,respectively,compared to those of the specimens under pure static loading.The crack sources,such as the primary fissures,strongly control the dynamic response of the coal specimen.The difference between the dynamic responses of the coal specimens and that of dense rocks is significant.
基金the Natural Science Foundation of Inner Mongolia,China(2023JQ01)the National Key R&D Program of China(2019YFA0607103)+2 种基金the Central Government Guides Local Science and Technology Development Fund Projects(2022ZY0224)the Open Project Program of Ministry of Education Key Laboratory of Ecology and Resources Use of the Mongolian Plateau,Hohhot,Inner Mongolia,China(KF2023003)Major Science and Technology Project of Inner Mongolia Autonomous Region:Monitoring,Assessment and Early Warning Technology Research of Biodiversity in Inner Mongolia(2021ZD0011)for financial support.
文摘Many different factors,such as species traits,socio-economic factors,geographical and environmental factors,can lead to specimen collection preference.This study aims to determine whether grassland specimen collection in China is preferred by species traits(i.e.,plant height,flowering and fruiting period),environmental range(i.e.,the temperature and precipitation range)and geographical range(i.e.,distribution range and altitudinal range).Ordinary least squares models and phylogenetic generalized linear mixed models were used to analyze the relationships between specimen number and the explanatory variables.Random Forest models were then used to find the most parsimonious multivariate model.The results showed that interannual variation in specimen number between 1900 and 2020 was considerable.Specimen number of these species in southeast China was notably lower than that in northwest China.Environmental range and geographical range of species had significant positive correlations with specimen number.In addition,there were relatively weak but significant associations between specimen number and species trait(i.e.,plant height and flowering and fruiting period).Random Forest models indicated that distribution range was the most important variable,followed by flowering and fruiting period,and altitudinal range.These findings suggest that future floristic surveys should pay more attention to species with small geographical range,narrow environmental range,short plant height,and short flowering and fruiting period.The correction of specimen collection preference will also make the results of species distribution model,species evolution and other works based on specimen data more accurate.
基金Financial support provided by Correlated Solutions Incorporated to perform StereoDIC experimentsthe Department of Mechanical Engineering at the University of South Carolina for simulation studies is deeply appreciated.
文摘To compare finite element analysis(FEA)predictions and stereovision digital image correlation(StereoDIC)strain measurements at the same spatial positions throughout a region of interest,a field comparison procedure is developed.The procedure includes(a)conversion of the finite element data into a triangular mesh,(b)selection of a common coordinate system,(c)determination of the rigid body transformation to place both measurements and FEA data in the same system and(d)interpolation of the FEA nodal information to the same spatial locations as the StereoDIC measurements using barycentric coordinates.For an aluminum Al-6061 double edge notched tensile specimen,FEA results are obtained using both the von Mises isotropic yield criterion and Hill’s quadratic anisotropic yield criterion,with the unknown Hill model parameters determined using full-field specimen strain measurements for the nominally plane stress specimen.Using Hill’s quadratic anisotropic yield criterion,the point-by-point comparison of experimentally based full-field strains and stresses to finite element predictions are shown to be in excellent agreement,confirming the effectiveness of the field comparison process.
文摘BACKGROUND Natural orifice specimen extraction surgery(NOSES)has emerged as a promising alternative compared to conventional laparoscopic-assisted total gastrectomy(LATG)for treating gastric cancer(GC).However,evidence regarding the efficacy and safety of NOSES for GC surgery is limited.This study aimed to compare the safety and feasibility,in addition to postoperative complications of NOSES and LATG.METHODS Dual circular staplers were used in Roux-en-Y digestive tract reconstruction for transvaginal specimen extraction LATG,and its outcomes were compared with LATG in a cohort of 51 GC patients with tumor size≤5 cm.The study was conducted from May 2018 to September 2020,and patients were categorized into the NOSES group(n=22)and LATG group(n=29).Perioperative parameters were compared and analyzed,including patient and tumor characteristics,postoperative outcomes,and anastomosis-related complications,postoperative hospital stay,the length of abdominal incision,difference in tumor type,postoperative complications,and postoperative survival.RESULTS Postoperative exhaust time,operation duration,mean postoperative hospital stay,length of abdominal incision,number of specific staplers used,and Brief Illness Perception Questionnaire score were significant in both groups(P<0.01).In the NOSES group,the postoperative time to first flatus,mean postoperative hospital stay,and length of abdominal incision were significantly shorter than those in the LATG group.Patients in the NOSES group had faster postoperative recovery,and achieved abdominal minimally invasive incision that met aesthetic requirements.There were no significant differences in gender,age,tumor type,postoperative complications,and postoperative survival between the two groups.CONCLUSION The application of dual circular staplers in Roux-en-Y digestive tract reconstruction combined with NOSES gastrectomy is safe and convenient.This approach offers better short-term outcomes compared to LATG,while long-term survival rates are comparable to those of conventional laparoscopic surgery.
文摘Using a scanning electron microscope (SEM) in the back-scattered electron (BSE) mode the composition of multi-element specimens may be determined based on the strong dependence of emission coefficient η on the average atomic number of elements Z. The output video signal of the usual BSE detectors is produced from their sensors, and the larger proportion of high-energy electrons with modified spectrum is added. Since η = is/ip (is and ip currents of specimen and probe), better accuracy must be achieved by direct measurements those currents on the specimen surface. Here, an experimental model of a current detector for a presented specimen is described. The cage is mounted on the carousel of the moving specimen stage. The input of the preamplifier is connected to the specimen holder in the form of a disk, the diameter of which is 12 mm. When the probe along its surface scanned, the input potential begins to pulsate with a negative polarity. The output of this preamplifier is connected to a small light-emitting diode, which creates intensity-modulated radiation in the chamber. Thus created the light video signal will be picked up by the photomultiplier of the E-T detector. The modes of true SE and BSE are set by applying tens bias volts of various polarities to the specimens or the cage itself.
文摘Objective:To analyze the application effect of feedforward control in outpatient blood specimen management.Methods:1,200 patients who had their venous blood collected in outpatient phlebotomy room of our hospital's outpatient clinic from January 2021 to April 2021 were selected as study subjects and divided into 600 cases in the control group and 600 cases in the observation group.The two groups of patients were compared in terms of their satisfaction with the staff,the efficiency of the nurses and the quality of nursing care,turnaround time before specimen analysis,the rejection rate of the blood specimens,and the time of result reporting.Results:After the implementation of feedforward control,patients'satisfaction with staff,nurses work efficiency and quality of care,turnaround time before specimen analysis,specimen rejection rate,and result reporting time in the observation group were significantly higher than those in the control group(P<0.05).Conclusion:The application of feedforward control in the management of outpatient blood specimens has significant effect,which effectively improves patients'satisfaction,enhances the efficiency of nurses and the quality of nursing care,shortens the turnaround time of specimens before analysis and the reporting time of results,and reduces the rejection rate of specimens.
基金National Natural Science Foundation of China,No.81860519.
文摘BACKGROUND Robotic resection using the natural orifice specimen extraction surgery I-type F method(R-NOSES I-F)is a novel minimally invasive surgical strategy for the treatment of lower rectal cancer.However,the current literature on this method is limited to case reports,and further investigation into its safety and feasibility is warranted.AIM To evaluate the safety and feasibility of R-NOSES I-F for the treatment of low rectal cancer.METHODS From September 2018 to February 2022,206 patients diagnosed with low rectal cancer at First Affiliated Hospital of Nanchang University were included in this retrospective analysis.Of these patients,22 underwent R-NOSES I-F surgery(RNOSES I-F group)and 76 underwent conventional robotic-assisted low rectal cancer resection(RLRC group).Clinicopathological data of all patients were collected and analyzed.Postoperative outcomes and prognoses were compared between the two groups.Statistical analysis was performed using SPSS software.RESULTS Patients in the R-NOSES I-F group had a significantly lower visual analog score for pain on postoperative day 1(1.7±0.7 vs 2.2±0.6,P=0.003)and shorter postoperative anal venting time(2.7±0.6 vs 3.5±0.7,P<0.001)than those in the RLRC group.There were no significant differences between the two groups in terms of sex,age,body mass index,tumor size,TNM stage,operative time,intrao-perative bleeding,postoperative complications,or inflammatory response(P>0.05).Postoperative anal and urinary functions,as assessed by Wexner,low anterior resection syndrome,and International Prostate Symptom Scale scores,were similar in both groups(P>0.05).Long-term follow-up revealed no significant differences in the rates of local recurrence and distant metastasis between the two groups(P>0.05).CONCLUSION R-NOSES I-F is a safe and effective minimally invasive procedure for the treatment of lower rectal cancer.It improves pain relief,promotes gastrointestinal function recovery,and helps avoid incision-related complications.
基金Funded by the International Science&Technology Cooperation Program of Hubei Province of China(No.2022EHB024)。
文摘To explore ways to improve the accuracy of quantitative analysis of samples in the micrometer to nanometer range of magnitudes,we adopted analytical transmission electron microscopy(AEM/EDS)for qualitative and quantitative analysis of pyrite materials.Additionally,the k factor of pyrite is calculated experimentally.To develop an appropriate non-standard quantitative analysis model for pyrite materials,the experimentally calculated k factor is compared with that estimated from the non-standard quantitative analytical model of the instrument software.The experimental findings demonstrate that the EDS attached to a TEM can be employed for precise quantitative analysis of micro-and nanoscale regions of pyrite materials.Furthermore,it serves as a reference for improving the results of the EDS quantitative analysis of other sulfides.
文摘The rejected specimens from the Emergency Department of the Center of Clinical Laboratory from January 1,2022 to January 1,2023 were analyzed to reduce the specimen rejection rates and to improve the quality of inspection.The results showed that there were 1488 samples of rejected specimens and the non-conforming rate was 0.58%.The departments involved were mainly the Emergency Department,the Hematology Department,the Cardiology Department,the Intensive Care Department,and the Brain Surgery Department.Among the reasons for rejection,blood hemolysis accounted for 43.15%,blood coagulation accounted for 26.61%,and the rate of insufficient specimens was 17.14%.Among them,the sample rejection rate for arterial blood gas analysis was the highest,which accounted for 1.74%;followed by specimens for coagulation test,which was 1.18%.These results indicate the main reason for producing rejected specimens is mainly due to not following the standard operating procedure.Specimen rejection can largely be avoided if the standards for specimen collection are strictly followed.