AIM:To examine performances regarding prediction of polyp histology using high-definition (HD) i-scan in a group of endoscopists with varying levels of experience. METHODS:We used a digital library of HD i-scan still ...AIM:To examine performances regarding prediction of polyp histology using high-definition (HD) i-scan in a group of endoscopists with varying levels of experience. METHODS:We used a digital library of HD i-scan still images, comprising twin pictures (surface enhancement and tone enhancement), collected at our university hospital. We defined endoscopic features of adenomatous and non-adenomatous polyps, according to the following parameters:color, surface pattern and vascular pattern. We familiarized the participating endoscopists on optical diagnosis of colorectal polyps using a 20-min didactic training session. All endoscopists were asked to evaluate an image set of 50 colorectal polyps with regard to polyp histology. We classified the diagnoses into high confidence (i.e., cases in which the endoscopist could assign a diagnosis with certainty) and low confidence diagnoses (i.e., cases in which the endoscopist preferred to send the polyp for formal histology). Mean sensitivity, specificity and accuracy per endoscopist/image were computed and differences between groups tested using independent-samples t tests. High vs low confidence diagnoses were compared using the pairedsamples t test. RESULTS:Eleven endoscopists without previous experience on optical diagnosis evaluated a total of 550 images (396 adenomatous, 154 non-adenomatous). Mean sensitivity, specificity and accuracy for diagnosing adenomas were 79.3%, 85.7% and 81.1%, respectively. No significant differences were found between gastroenterologists and trainees regarding performances of optical diagnosis (mean accuracy 78.0%vs 82.9%,P = 0.098). Diminutive lesions were predicted with a lower mean accuracy as compared to non-diminutive lesions (74.2% vs 93.1%, P = 0.008). A total of 446 (81.1%) diagnoses were made with high confidence. High confidence diagnoses corresponded to a significantly higher mean accuracy than low confidence diagnoses (84.0% vs 64.3%, P = 0.008). A total of 319 (58.0%) images were evaluated as having excellent quality. Considering excellent quality images in conjunction with high confidence diagnosis, overall accuracy increased to 92.8%. CONCLUSION:After a single training session, endoscopists with varying levels of experience can already provide optical diagnosis with an accuracy of 84.0%.展开更多
Cu-rich cell boundary phase is difficult to precipitate evenly,resulting in a generally poor demagnetization curve squareness for Fe-rich Sm_(2)Co_(17)-type magnet,which is a key factor limiting the further improvemen...Cu-rich cell boundary phase is difficult to precipitate evenly,resulting in a generally poor demagnetization curve squareness for Fe-rich Sm_(2)Co_(17)-type magnet,which is a key factor limiting the further improvement of magnetic energy product.In this study,we report that nanoscale strip-like ordered micro-domains distributed in1:7H disordered matrix phase of the solid solution precursor is a new factor significantly affecting the precipitation and distribution of the cell boundary phase.Long strip-like and continuous micro-twin structure with twin boundaries neatly perpendicular to the C-axis is observed after sintering treatment.After solution treatment,sequential and long strip-like micro-twins gradually transform into disordered state along the basal plane,forming narrow disordered 1:7H(TbCu_(7)-type structure)phase between the separated strip-like ordered micro-domains.This disordering transformation takes place via broken down of the long strip-like ordered micro-domains,which is accomplished by narrowing along the width direction followed by reduction of the length.Furthermore,a new model revealing the effect of the ordered micro-domains on the formation of the cell boundary phase is proposed.Antiphase boundaries enriched in Cu have already existed in the precursor with long strip-like ordered micro-domains.Therefore,the Cu-rich cell boundary phase acting as strong pinning centers cannot be precipitated homogeneously and distributed continuously after aging,resulting in a poor demagnetization curve squareness of Sm_(2)Co_(17)-type magnet.Our results indicate that significant broken down of the nanoscale ordered micro-domains in solution precursor is the key factor improving the distribution of cell boundary phase in Sm_(2)Co_(17)-type magnets.展开更多
AIM: To evaluate the feasibility of a new computed virtual chromoendoscopy (CVC) device (M i-scan) in the diagnosis of gastric neoplasia. METHODS: Patients with superficial lesions no larger than 1.0 cm found during h...AIM: To evaluate the feasibility of a new computed virtual chromoendoscopy (CVC) device (M i-scan) in the diagnosis of gastric neoplasia. METHODS: Patients with superficial lesions no larger than 1.0 cm found during high definition endoscopy were included. Those with advanced or obviously protruded or depressed lesions, lesions larger than 1.0 cm and/or lesions which were not amenable to observation by zoom function were excluded. The endoscopist was required to give the real-time descriptions of surface pit patterns of the lesions, based on surface pattern classification of enhanced magnification endoscopy. According to previous reports, types Ⅰ-Ⅲ represent nonneoplastic lesions, and types Ⅳ-Ⅴ represent neoplastic lesions. Diagnosis with M i-scan and biopsy was performed before histopathological diagnosis. Magnified images of gastric lesions with and without enhancement were collected for further analysis. The diagnostic yield of real-time M i-scan and effects on magnification image quality by tone enhancement (TE), surface enhancement (SE) and color enhancement (CE) were calculated. The selected images were sent to another endoscopist. The endoscopist rated the image quality of each lesion at 3 levels. Ratings of image quality were based on visualization of pit pattern, vessel and demarcation line. RESULTS: One hundred and eighty-three patients were recruited. Five patients were excluded for advanced gastric lesions, 1 patient was excluded for poor preparation and 2 patients were excluded for superficial lesions larger than 1.0 cm; 132 patients were excluded for no lesions found by high definition endoscopy. In the end, 43 patients with 43 lesions were included. Histopathology revealed 10 inflammation, 14 atrophy, 10 metaplasia, 1 low grade dysplasia (LGD), 5 high grade dysplasia (HGD) and 3 cancers. For 7 lesions classified into type Ⅰ, histopathology revealed 6 atrophy and 1 metaplasia; for 10 lesions classified into type Ⅱ, histopathology revealed 2 inflammation, 7 atrophy and 1 metaplasia; for 10 lesions classified into type Ⅲ, histopathology revealed 1 inflammation, 8 metaplasia and 1 LGD; for 9 lesions classified into type Ⅳ, histopathology revealed 4 inflammation, 1 atrophy and 4 HGD; for 7 lesions classified into type Ⅴ, histopathology revealed 3 inflammation, 1 HGD and 3 cancers. A total of 172 still images, including 43 images by white light (MWL) and 129 images by M i-scan (43 with TE, 43 with SE and 43 with CE), were selected and sent to the endoscopist who did the analysis. General image quality of M i-scan with TE and SE was significantly better than that of MWL (TE, 4.55 ± 1.07; SE, 4.30 ± 1.02; MWL, 3.25 ± 0.99; P < 0.001). Visualization of pit pattern was significantly improved by M i-scan with SE (1.93 ± 0.25 vs 1.50 ± 0.50, P < 0.001). Microvessel visualization was significantly improved by M i-scan with TE (1.23 ± 0.78 vs 0.76 ± 0.73, P < 0.001). Demarcation line visualization was improved by M i-scan with both TE and SE (TE, 1.75 ± 0.52; SE, 1.56 ± 0.59; MWL, 0.98 ± 0.44; P < 0.001). M i-scan with CE did not show any significant improvements of image quality in general or in the 3 key parameters. Although M i-scan with TE and SE slightly increased the diagnostic yield of MWL, there was no significant difference (P > 0.1). CONCLUSION: Although digital enhancement improves the image quality of magnification endoscopy, its value in improving the diagnostic yield seems to be limited.展开更多
There have been major developments in endoscopic imaging techniques in recent years.Endoscopes with high definition and magnification can provide high quality images that allow for the histological estimation of lesio...There have been major developments in endoscopic imaging techniques in recent years.Endoscopes with high definition and magnification can provide high quality images that allow for the histological estimation of lesions in vivo and in situ when combined with ancillary enhancement techniques such as chromoendoscopy(CE)and virtual CE(narrow band imaging fujinon intelligent chromoendoscopy,or i-Scan).Despite the enormous potential for these advanced techniques,their value and feasibility in the clinic are still doubted,particularly in cases of colonic polyps that are slated for removal,where in vivo characterization may be deemed unnecessary.However,there are several advantages offered by such advanced endoscopic imaging.CE with or without magnification demonstrates highly accurate histology and invasion depth prediction,and virtual CE is a feasible and less cumbersome alternative to CE in terms of histological estimation,though not sufficiently accurate for depth invasion prediction.Furthermore,the supplementary information provided by advanced imaging systems can assist the endoscopist in the selection of a strategic approach,such as in deciding whether a colonic lesion should be resected,left in situ,or requires more intensive surgical treatment.Lastly,advanced high-resolution imaging techniques may be more cost effective,such that histopathology of lowrisk lesions following resection can be eliminated.The results of these evaluations and comparisons with traditional CE are presented and discussed.Taken together,the benefits provided by these advanced capabilities justify their development,and advocates their use for the treatment and management of colonic polyps.展开更多
文摘AIM:To examine performances regarding prediction of polyp histology using high-definition (HD) i-scan in a group of endoscopists with varying levels of experience. METHODS:We used a digital library of HD i-scan still images, comprising twin pictures (surface enhancement and tone enhancement), collected at our university hospital. We defined endoscopic features of adenomatous and non-adenomatous polyps, according to the following parameters:color, surface pattern and vascular pattern. We familiarized the participating endoscopists on optical diagnosis of colorectal polyps using a 20-min didactic training session. All endoscopists were asked to evaluate an image set of 50 colorectal polyps with regard to polyp histology. We classified the diagnoses into high confidence (i.e., cases in which the endoscopist could assign a diagnosis with certainty) and low confidence diagnoses (i.e., cases in which the endoscopist preferred to send the polyp for formal histology). Mean sensitivity, specificity and accuracy per endoscopist/image were computed and differences between groups tested using independent-samples t tests. High vs low confidence diagnoses were compared using the pairedsamples t test. RESULTS:Eleven endoscopists without previous experience on optical diagnosis evaluated a total of 550 images (396 adenomatous, 154 non-adenomatous). Mean sensitivity, specificity and accuracy for diagnosing adenomas were 79.3%, 85.7% and 81.1%, respectively. No significant differences were found between gastroenterologists and trainees regarding performances of optical diagnosis (mean accuracy 78.0%vs 82.9%,P = 0.098). Diminutive lesions were predicted with a lower mean accuracy as compared to non-diminutive lesions (74.2% vs 93.1%, P = 0.008). A total of 446 (81.1%) diagnoses were made with high confidence. High confidence diagnoses corresponded to a significantly higher mean accuracy than low confidence diagnoses (84.0% vs 64.3%, P = 0.008). A total of 319 (58.0%) images were evaluated as having excellent quality. Considering excellent quality images in conjunction with high confidence diagnosis, overall accuracy increased to 92.8%. CONCLUSION:After a single training session, endoscopists with varying levels of experience can already provide optical diagnosis with an accuracy of 84.0%.
基金financially supported by the National Key R&D Program of China(No.2021YFB3503102)Zhejiang Provincial Key R&D Program(No.2021C01191)+2 种基金Science and Technology Innovation 2025 Major Project of Ningbo(No.2020Z037)Ningbo Key R&D Program(No.20222ZDYF020027)Ningbo Natural Science Foundation(No.2021J216)。
文摘Cu-rich cell boundary phase is difficult to precipitate evenly,resulting in a generally poor demagnetization curve squareness for Fe-rich Sm_(2)Co_(17)-type magnet,which is a key factor limiting the further improvement of magnetic energy product.In this study,we report that nanoscale strip-like ordered micro-domains distributed in1:7H disordered matrix phase of the solid solution precursor is a new factor significantly affecting the precipitation and distribution of the cell boundary phase.Long strip-like and continuous micro-twin structure with twin boundaries neatly perpendicular to the C-axis is observed after sintering treatment.After solution treatment,sequential and long strip-like micro-twins gradually transform into disordered state along the basal plane,forming narrow disordered 1:7H(TbCu_(7)-type structure)phase between the separated strip-like ordered micro-domains.This disordering transformation takes place via broken down of the long strip-like ordered micro-domains,which is accomplished by narrowing along the width direction followed by reduction of the length.Furthermore,a new model revealing the effect of the ordered micro-domains on the formation of the cell boundary phase is proposed.Antiphase boundaries enriched in Cu have already existed in the precursor with long strip-like ordered micro-domains.Therefore,the Cu-rich cell boundary phase acting as strong pinning centers cannot be precipitated homogeneously and distributed continuously after aging,resulting in a poor demagnetization curve squareness of Sm_(2)Co_(17)-type magnet.Our results indicate that significant broken down of the nanoscale ordered micro-domains in solution precursor is the key factor improving the distribution of cell boundary phase in Sm_(2)Co_(17)-type magnets.
基金Supported by The National Clinical Project from the Health Ministry of Chinathe Shandong Province Science and Technology Committee, No. 2010GSF10247National Natural Foundation of Science of China, No. NSFC81101098
文摘AIM: To evaluate the feasibility of a new computed virtual chromoendoscopy (CVC) device (M i-scan) in the diagnosis of gastric neoplasia. METHODS: Patients with superficial lesions no larger than 1.0 cm found during high definition endoscopy were included. Those with advanced or obviously protruded or depressed lesions, lesions larger than 1.0 cm and/or lesions which were not amenable to observation by zoom function were excluded. The endoscopist was required to give the real-time descriptions of surface pit patterns of the lesions, based on surface pattern classification of enhanced magnification endoscopy. According to previous reports, types Ⅰ-Ⅲ represent nonneoplastic lesions, and types Ⅳ-Ⅴ represent neoplastic lesions. Diagnosis with M i-scan and biopsy was performed before histopathological diagnosis. Magnified images of gastric lesions with and without enhancement were collected for further analysis. The diagnostic yield of real-time M i-scan and effects on magnification image quality by tone enhancement (TE), surface enhancement (SE) and color enhancement (CE) were calculated. The selected images were sent to another endoscopist. The endoscopist rated the image quality of each lesion at 3 levels. Ratings of image quality were based on visualization of pit pattern, vessel and demarcation line. RESULTS: One hundred and eighty-three patients were recruited. Five patients were excluded for advanced gastric lesions, 1 patient was excluded for poor preparation and 2 patients were excluded for superficial lesions larger than 1.0 cm; 132 patients were excluded for no lesions found by high definition endoscopy. In the end, 43 patients with 43 lesions were included. Histopathology revealed 10 inflammation, 14 atrophy, 10 metaplasia, 1 low grade dysplasia (LGD), 5 high grade dysplasia (HGD) and 3 cancers. For 7 lesions classified into type Ⅰ, histopathology revealed 6 atrophy and 1 metaplasia; for 10 lesions classified into type Ⅱ, histopathology revealed 2 inflammation, 7 atrophy and 1 metaplasia; for 10 lesions classified into type Ⅲ, histopathology revealed 1 inflammation, 8 metaplasia and 1 LGD; for 9 lesions classified into type Ⅳ, histopathology revealed 4 inflammation, 1 atrophy and 4 HGD; for 7 lesions classified into type Ⅴ, histopathology revealed 3 inflammation, 1 HGD and 3 cancers. A total of 172 still images, including 43 images by white light (MWL) and 129 images by M i-scan (43 with TE, 43 with SE and 43 with CE), were selected and sent to the endoscopist who did the analysis. General image quality of M i-scan with TE and SE was significantly better than that of MWL (TE, 4.55 ± 1.07; SE, 4.30 ± 1.02; MWL, 3.25 ± 0.99; P < 0.001). Visualization of pit pattern was significantly improved by M i-scan with SE (1.93 ± 0.25 vs 1.50 ± 0.50, P < 0.001). Microvessel visualization was significantly improved by M i-scan with TE (1.23 ± 0.78 vs 0.76 ± 0.73, P < 0.001). Demarcation line visualization was improved by M i-scan with both TE and SE (TE, 1.75 ± 0.52; SE, 1.56 ± 0.59; MWL, 0.98 ± 0.44; P < 0.001). M i-scan with CE did not show any significant improvements of image quality in general or in the 3 key parameters. Although M i-scan with TE and SE slightly increased the diagnostic yield of MWL, there was no significant difference (P > 0.1). CONCLUSION: Although digital enhancement improves the image quality of magnification endoscopy, its value in improving the diagnostic yield seems to be limited.
基金Supported by The CIBERehd(Centro de Investigación Biomédica en Red,enfermedades hepaticas y digestivas)to Sanabria E
文摘There have been major developments in endoscopic imaging techniques in recent years.Endoscopes with high definition and magnification can provide high quality images that allow for the histological estimation of lesions in vivo and in situ when combined with ancillary enhancement techniques such as chromoendoscopy(CE)and virtual CE(narrow band imaging fujinon intelligent chromoendoscopy,or i-Scan).Despite the enormous potential for these advanced techniques,their value and feasibility in the clinic are still doubted,particularly in cases of colonic polyps that are slated for removal,where in vivo characterization may be deemed unnecessary.However,there are several advantages offered by such advanced endoscopic imaging.CE with or without magnification demonstrates highly accurate histology and invasion depth prediction,and virtual CE is a feasible and less cumbersome alternative to CE in terms of histological estimation,though not sufficiently accurate for depth invasion prediction.Furthermore,the supplementary information provided by advanced imaging systems can assist the endoscopist in the selection of a strategic approach,such as in deciding whether a colonic lesion should be resected,left in situ,or requires more intensive surgical treatment.Lastly,advanced high-resolution imaging techniques may be more cost effective,such that histopathology of lowrisk lesions following resection can be eliminated.The results of these evaluations and comparisons with traditional CE are presented and discussed.Taken together,the benefits provided by these advanced capabilities justify their development,and advocates their use for the treatment and management of colonic polyps.