Aniline is a vital industrial raw material.However,highly-toxic aniline wastewater usually deteriorated effluent quality,posed a threat to human health and ecosystem safety.Therefore,this study reported a novel intern...Aniline is a vital industrial raw material.However,highly-toxic aniline wastewater usually deteriorated effluent quality,posed a threat to human health and ecosystem safety.Therefore,this study reported a novel internal circulation iron-carbon micro-electrolysis(ICE)reactor to treat aniline wastewater.The effects of reaction time,pH,aeration rate and iron-carbon(Fe/C)ratio on the removal rate of aniline and the chemical oxygen demand were investigated using single-factor experiments.This process exhibited high aniline degradation performance of approximately 99.86% under optimal operating conditions(reaction time=20 min,pH=3,aeration rate=0.5 m3·h^(-1),and Fe/C=1:2).Based on the experimental results,the response surface method was applied to optimize the aniline removal rate.The Box–Behnken method was used to obtain the interaction effects of three main factors.The result showed that the reaction time had a dominant effect on the removal rate of aniline.The highest aniline removal rate was obtained at pH of 2,aeration rate of 0.5 m^(3)·h^(-1)and reaction time of 30 min.Under optional experimental conditions,the aniline content of effluent was reduced to 3 mg·L^(-1)and the removal rate was as high as 98.24%,within the 95% confidence interval(97.84%-99.32%)of the predicted values.The solution was treated and the reaction intermediates were identified by high-performance liquid chromatography,ultraviolet-visible spectroscopy,Fourier-transform infrared spectroscopy,gas chromatography-mass spectrometry,and ion chromatography.The main intermediates were phenol,benzoquinone,and carboxylic acid.These were used to propose the potential mechanism of aniline degradation in the ICE reactor.The results obtained in this study provide optimized conditions for the treatment of industrial wastewater containing aniline and can strengthen the understanding of the degradation mechanism of iron-carbon micro-electrolysis.展开更多
The degradation of five naphthalene derivatives in the simulated wastewater was investigated using the iron-carbon micro-electrolysis method.The optimal initial pH of solution and adsorption of iron-carbon and removal...The degradation of five naphthalene derivatives in the simulated wastewater was investigated using the iron-carbon micro-electrolysis method.The optimal initial pH of solution and adsorption of iron-carbon and removal efficiency of the total organic carbon(TOC)were investigated.The results show that the removal efficiency of the naphthalene derivatives can reach 48.9%?92.6% and the removal efficiency of TOC is 42.8%?78.0% for the simulated wastewater with 200 mg/L naphthalene derivatives at optimal pH of 2.0?2.5 after 120 min treatment.The degradation of five naphthalene derivatives with the micro-electrolysis shows the apparent first-order kinetics and the order of removal efficiency of the naphthalene derivatives is sodium 2-naphthalenesulfonate,2-naphthol,2,7-dihydroxynaphthalene,1-naphthamine,1-naphthol-8-sulfonic acid in turn.It is illustrated that the substituents of the naphthalene ring can affect the removal efficiency of naphthalene due to their electron-withdrawing or electron-donating ability.展开更多
Experiments were conducted to study the role of micro-electrolysis in removing chromaticity and COD and improving the biodegradability of wastewater from pharmaceutical, dye-printing and papermaking plants. Results sh...Experiments were conducted to study the role of micro-electrolysis in removing chromaticity and COD and improving the biodegradability of wastewater from pharmaceutical, dye-printing and papermaking plants. Results showed that the use of micro-electrolysis technology could remove more than 90% of chromaticity and more than 50% of COD and greatly improved the biodegradability of pharmaceutical wastewater. Lower initial pH could be advantageous to the removal of chromaticity. A retention time of 30 minutes was recommended for the process design of micro-electrolysis. For the use of micro-electrolysis in treatment of dye-printing wastewater, the removal rates of both chromaticity and COD were increased from neutral condition to acid condition for disperse blue wastewater; more than 90% of chromaticity and more than 50% of COD could be removed in neutral condition for vital red wastewater.展开更多
The reduction of nitrate using internal circulation micro-electrolysis te chnology(ICE)was investigated.The effect of the reaction time,initial pH,Fe/C ratio,and aeration rate on the nitrate reduction was investigated...The reduction of nitrate using internal circulation micro-electrolysis te chnology(ICE)was investigated.The effect of the reaction time,initial pH,Fe/C ratio,and aeration rate on the nitrate reduction was investigated using a single factor experiment.Based on the results of the single factor experiment,a response surface methodology(RSM)was applied to optimize the N2 generation selectivity.The effects and interactions of three independent variables were estimated using a Box-Behnken design.Using the RSM analysis,a quadratic polynomial model with optimal conditions at pH=8.8,Fe/C=1:1,and an aeration rate of 30 L·min-1 was developed by means of the regre ssion analysis of the experimental data.Using the RSM optimization,the optimal conditions yielded a N2 generation selectivity of 72.0%,which is in good agreement with experimental result(73.2%±0.5%)and falls within the 95%confidence interval(IC:66.8%-77.3%)of the model results.This indicates that the model obtained in this study effectively predicts the N2 generation selectivity for nitrate reduction by the ICE process,thus providing a theoretical basis for process design.展开更多
The nitrate nitrogen removal efficiency of iron-carbon micro-electrolysis system was discussed in treating pharmaceutical wastewater with high nitrogen and refractory organic concentration. The results show that the g...The nitrate nitrogen removal efficiency of iron-carbon micro-electrolysis system was discussed in treating pharmaceutical wastewater with high nitrogen and refractory organic concentration. The results show that the granularity of fillings,pH,volume ratios of iron-carbon and gas-water,and HRT. have significant effects on the nitrogen removal efficiency of iron-carbon micro-electrolysis system. The iron-carbon micro-electrolysis system has a good removal efficiency of pharmaceutical wastewater with high nitrogen and refractory organic concentration when the influent TN,NH4+-N,NO3--N and BOD5/CODCr are 823 mg/L,30 mg/L,793 mg/L and 0.1,respectively,at the granularity of iron and carbon 0.425 mm,pH 3,iron-carbon ratio 3,gas-water ratio 5,HRT 1.5 h,and the removal rates of TN,NH4+-N and NO3--N achieve 51.5%,70% and 50.94%,respectively.展开更多
It is generally recognized that internal-loop reactors are well-developed mass and heat-transfer multiphase flow reactors. However, the internal flow field in the internal-loop reactor is influenced by the structure p...It is generally recognized that internal-loop reactors are well-developed mass and heat-transfer multiphase flow reactors. However, the internal flow field in the internal-loop reactor is influenced by the structure parameter of the reactor, which has a great effect on the reaction efficiency. In this study, the computational fluid dynamics simulation method was used to determine the influence of reactor structure on flow field, and a volume-offluid model was employed to simulate the gas–liquid, two-phase flow of the internal-loop micro-electrolysis reactor. Hydrodynamic factors were optimized when the height-to-diameter ratio was 4:1, diameter ratio was9:1, draft-tube axial height was 90 mm. Three-dimensional simulations for the water distributor were carried out, and the results suggested that the optimal conditions are as follows: the number of water distribution pipes was four, and an inhomogeneous water distribution was used. According to the results of the simulation,the suitable structure can be used to achieve good fluid mechanical properties, such as the good liquid circulation velocity and gas holdup, which provides a good theoretical foundation for the application of the reactor.展开更多
The zero valent iron/granular active carbon(ZVI/GAC) micro-electrolysis enhanced by ultrasound(US) coupled with hydrogen peroxide(H_2O_2) was investigated for the deep degradation of nitrobenzene-containing wastewater...The zero valent iron/granular active carbon(ZVI/GAC) micro-electrolysis enhanced by ultrasound(US) coupled with hydrogen peroxide(H_2O_2) was investigated for the deep degradation of nitrobenzene-containing wastewater. The results of scanning electron microscopy-energy dispersive X-rays analysis(SEM-EDS) demonstrated that continuously accelerated regeneration of ZVI and GAC in situ by US could improve the process for converting nitrobenzene(NB) to aniline(AN). H_2O_2 was decomposed catalytically by the byproduct Fe^(2+) ions generated in the micro-electrolysis process to hydroxyl radicals and the organic pollutants in the wastewater were finally mineralized to CO2 and H2O. Effects of the ZVI dosage, the ZVI/GAC mass ratio, the initial pH value and the H_2O_2 dosage on the efficiency for degradation of NB were studied in these experiments. The optimal operating conditions covered a ZVI dosage of 15 g/L, a ZVI/GAC mass ratio of 1:2,an initial pH value of 3 and a H_2O_2 dosage of 4 mL. In this case, the NB removal efficiency reached 97.72% and the total organic carbon(TOC) removal efficiency reached 73.42% at a NB concentration of 300 mg/L. The reduction of NB by USZVI/GAC followed the pseudo-first-order kinetics model, and the pseudo-first-order rate constants were given at different initial pH values. The reaction intermediates such as AN, benzoquinonimine, p-benzoquinone, p-nitrophenol and other organic acids were detected and a probable pathway for NB degradation has been proposed.展开更多
With the continuous deepening of rural revitalization strategy and the increasingly strict sewage discharge standards,rural domestic sewage treatment technology is facing higher challenges and requirements.The combine...With the continuous deepening of rural revitalization strategy and the increasingly strict sewage discharge standards,rural domestic sewage treatment technology is facing higher challenges and requirements.The combined process of micro-electrolysis+micro-nano bubbles coupled with peroxymonosulfate was constructed in this study,and the treatment effect and application value of this technology were explored with the actual rural domestic sewage as the treatment object.The experimental results showed that under the conditions of HRT of 120 min,PMS dosage of 0.15 mmol/L,pH=7,MBs air intake of 15 ml/min,current intensity of 15 A,and Fe/C mass ratio of 1:1,the removal rates of COD,ammonia nitrogen and total phosphorus can reach 88.55%,77.18%and 74.67%,respectively.Under the condition that the pH value of sewage was not adjusted,the non-biochemical simultaneous decarbonization,denitrification and phosphorus removal of rural domestic sewage can be achieved by micro-electrolysis and micro-nano bubbles coupled with peroxymonosulfate.The concentrations of effluent COD,ammonia nitrogen and total phosphorus met the requirements of the first level standard of the Discharge Standard of Water Pollutants for Rural Domestic Sewage Treatment Facilities(DB45T2413-2021).And the comprehensive operating cost was about 1.15 yuan/m 3.展开更多
针对配电系统中时有发生的并联电容器与电网阻抗之间谐振的现象,该文首先分析了传统的负载电流检测方式下并联型有源电力滤波器(parallel active power filter,PAPF)对系统谐振的抑制情况。分析表明,由于无功补偿电容器的影响,传统控制...针对配电系统中时有发生的并联电容器与电网阻抗之间谐振的现象,该文首先分析了传统的负载电流检测方式下并联型有源电力滤波器(parallel active power filter,PAPF)对系统谐振的抑制情况。分析表明,由于无功补偿电容器的影响,传统控制策略下的PAPF对系统谐振的抑制效果不理想,同时当检测的负载电流中包括无功补偿电容器电流时,系统还有可能出现不稳定的现象。针对这种情况该文提出了一种新的PAPF控制策略,该控制策略可以在进行谐波治理的同时有效抑制负载谐波电流或者系统谐波电压造成的并联电容器与电网阻抗之间的谐振。最后给出了实验验证结果。展开更多
Treatment of oilfield produced water was investigated using an anaerobic process coupled with micro-electrolysis (ME), focusing on changes in chemical oxygen demand (COD) and biodegradability. Results showed that ...Treatment of oilfield produced water was investigated using an anaerobic process coupled with micro-electrolysis (ME), focusing on changes in chemical oxygen demand (COD) and biodegradability. Results showed that COD exhibited an abnormal change in the single anaerobic system in which it increased within the first 168 hr, but then decreased to 222 mg/L after 360 hr. The biological oxygen demand (five-day) (BOD5)/COD ratio of the water increased from 0.05 to 0.15. Hydrocarbons in the wastewater, such as pectin, degraded to small molecules during the hydrolytic acidification process. Comparatively, the effect of ME was also investigated. The COD underwent a slight decrease and the BOD5/COD ratio of the water improved from 0,05 to 0.17 after ME. Removal of COD was 38.3% under the idealized ME conditions (pH 6.0), using iron and active carbon (80 and 40 g/L, respectively). Coupling the anaerobic process with ME accelerated the COD removal ratio (average removal was 53.3%). Gas chromatography/mass spectrometry was used to analyze organic species conversion. This integrated system appeared to be a useful option for the treatment of water produced in oilfields.展开更多
基金supported by the National Natural Science Foundation of China(21677018)the Joint Fund of the Beijing Municipal Natural Science Foundation and Beijing Municipal Education Commission(KZ201810017024)the Cross-Disciplinary Science Foundation from Beijing Institute of Petrochemical Technology(BIPTCSF–22032205003/014)。
文摘Aniline is a vital industrial raw material.However,highly-toxic aniline wastewater usually deteriorated effluent quality,posed a threat to human health and ecosystem safety.Therefore,this study reported a novel internal circulation iron-carbon micro-electrolysis(ICE)reactor to treat aniline wastewater.The effects of reaction time,pH,aeration rate and iron-carbon(Fe/C)ratio on the removal rate of aniline and the chemical oxygen demand were investigated using single-factor experiments.This process exhibited high aniline degradation performance of approximately 99.86% under optimal operating conditions(reaction time=20 min,pH=3,aeration rate=0.5 m3·h^(-1),and Fe/C=1:2).Based on the experimental results,the response surface method was applied to optimize the aniline removal rate.The Box–Behnken method was used to obtain the interaction effects of three main factors.The result showed that the reaction time had a dominant effect on the removal rate of aniline.The highest aniline removal rate was obtained at pH of 2,aeration rate of 0.5 m^(3)·h^(-1)and reaction time of 30 min.Under optional experimental conditions,the aniline content of effluent was reduced to 3 mg·L^(-1)and the removal rate was as high as 98.24%,within the 95% confidence interval(97.84%-99.32%)of the predicted values.The solution was treated and the reaction intermediates were identified by high-performance liquid chromatography,ultraviolet-visible spectroscopy,Fourier-transform infrared spectroscopy,gas chromatography-mass spectrometry,and ion chromatography.The main intermediates were phenol,benzoquinone,and carboxylic acid.These were used to propose the potential mechanism of aniline degradation in the ICE reactor.The results obtained in this study provide optimized conditions for the treatment of industrial wastewater containing aniline and can strengthen the understanding of the degradation mechanism of iron-carbon micro-electrolysis.
基金Project(05KJD6010110) supported by the Natural Science Foundation of the Education Commission of Jiangsu Province,ChinaProject(2005005) supported by the Science and Technology Foundation of the Environmental Protection Bureau of Jiangsu Province,China
文摘The degradation of five naphthalene derivatives in the simulated wastewater was investigated using the iron-carbon micro-electrolysis method.The optimal initial pH of solution and adsorption of iron-carbon and removal efficiency of the total organic carbon(TOC)were investigated.The results show that the removal efficiency of the naphthalene derivatives can reach 48.9%?92.6% and the removal efficiency of TOC is 42.8%?78.0% for the simulated wastewater with 200 mg/L naphthalene derivatives at optimal pH of 2.0?2.5 after 120 min treatment.The degradation of five naphthalene derivatives with the micro-electrolysis shows the apparent first-order kinetics and the order of removal efficiency of the naphthalene derivatives is sodium 2-naphthalenesulfonate,2-naphthol,2,7-dihydroxynaphthalene,1-naphthamine,1-naphthol-8-sulfonic acid in turn.It is illustrated that the substituents of the naphthalene ring can affect the removal efficiency of naphthalene due to their electron-withdrawing or electron-donating ability.
文摘Experiments were conducted to study the role of micro-electrolysis in removing chromaticity and COD and improving the biodegradability of wastewater from pharmaceutical, dye-printing and papermaking plants. Results showed that the use of micro-electrolysis technology could remove more than 90% of chromaticity and more than 50% of COD and greatly improved the biodegradability of pharmaceutical wastewater. Lower initial pH could be advantageous to the removal of chromaticity. A retention time of 30 minutes was recommended for the process design of micro-electrolysis. For the use of micro-electrolysis in treatment of dye-printing wastewater, the removal rates of both chromaticity and COD were increased from neutral condition to acid condition for disperse blue wastewater; more than 90% of chromaticity and more than 50% of COD could be removed in neutral condition for vital red wastewater.
基金Supported by the National Natural Science Foundation of China(21677018)the Joint Fund of the Beijing Natural Science Foundation and Beijing Municipal Education Commission(KZ201810017024).
文摘The reduction of nitrate using internal circulation micro-electrolysis te chnology(ICE)was investigated.The effect of the reaction time,initial pH,Fe/C ratio,and aeration rate on the nitrate reduction was investigated using a single factor experiment.Based on the results of the single factor experiment,a response surface methodology(RSM)was applied to optimize the N2 generation selectivity.The effects and interactions of three independent variables were estimated using a Box-Behnken design.Using the RSM analysis,a quadratic polynomial model with optimal conditions at pH=8.8,Fe/C=1:1,and an aeration rate of 30 L·min-1 was developed by means of the regre ssion analysis of the experimental data.Using the RSM optimization,the optimal conditions yielded a N2 generation selectivity of 72.0%,which is in good agreement with experimental result(73.2%±0.5%)and falls within the 95%confidence interval(IC:66.8%-77.3%)of the model results.This indicates that the model obtained in this study effectively predicts the N2 generation selectivity for nitrate reduction by the ICE process,thus providing a theoretical basis for process design.
基金Project(2009ZX07315-005) supported by the National Water Pollution Controlled and Treatment Great Special of China
文摘The nitrate nitrogen removal efficiency of iron-carbon micro-electrolysis system was discussed in treating pharmaceutical wastewater with high nitrogen and refractory organic concentration. The results show that the granularity of fillings,pH,volume ratios of iron-carbon and gas-water,and HRT. have significant effects on the nitrogen removal efficiency of iron-carbon micro-electrolysis system. The iron-carbon micro-electrolysis system has a good removal efficiency of pharmaceutical wastewater with high nitrogen and refractory organic concentration when the influent TN,NH4+-N,NO3--N and BOD5/CODCr are 823 mg/L,30 mg/L,793 mg/L and 0.1,respectively,at the granularity of iron and carbon 0.425 mm,pH 3,iron-carbon ratio 3,gas-water ratio 5,HRT 1.5 h,and the removal rates of TN,NH4+-N and NO3--N achieve 51.5%,70% and 50.94%,respectively.
基金Supported by the National Natural Science Foundation of China(21677018)Jointly Projects of Beijing Natural Science Foundation and Beijing Municipal Education Commission(KZ201810017024)
文摘It is generally recognized that internal-loop reactors are well-developed mass and heat-transfer multiphase flow reactors. However, the internal flow field in the internal-loop reactor is influenced by the structure parameter of the reactor, which has a great effect on the reaction efficiency. In this study, the computational fluid dynamics simulation method was used to determine the influence of reactor structure on flow field, and a volume-offluid model was employed to simulate the gas–liquid, two-phase flow of the internal-loop micro-electrolysis reactor. Hydrodynamic factors were optimized when the height-to-diameter ratio was 4:1, diameter ratio was9:1, draft-tube axial height was 90 mm. Three-dimensional simulations for the water distributor were carried out, and the results suggested that the optimal conditions are as follows: the number of water distribution pipes was four, and an inhomogeneous water distribution was used. According to the results of the simulation,the suitable structure can be used to achieve good fluid mechanical properties, such as the good liquid circulation velocity and gas holdup, which provides a good theoretical foundation for the application of the reactor.
基金supported by the Natural Science Foundation of China (U1610106)the Excellent Youth Science and Technology Foundation of Province Shanxi of China (2014021007)+1 种基金the Specialized Research Fund for Sanjin Scholars Pragram of Shanxi Prouince (201707)the North University of China Fund for Distinguished Young Scholars (201701)
文摘The zero valent iron/granular active carbon(ZVI/GAC) micro-electrolysis enhanced by ultrasound(US) coupled with hydrogen peroxide(H_2O_2) was investigated for the deep degradation of nitrobenzene-containing wastewater. The results of scanning electron microscopy-energy dispersive X-rays analysis(SEM-EDS) demonstrated that continuously accelerated regeneration of ZVI and GAC in situ by US could improve the process for converting nitrobenzene(NB) to aniline(AN). H_2O_2 was decomposed catalytically by the byproduct Fe^(2+) ions generated in the micro-electrolysis process to hydroxyl radicals and the organic pollutants in the wastewater were finally mineralized to CO2 and H2O. Effects of the ZVI dosage, the ZVI/GAC mass ratio, the initial pH value and the H_2O_2 dosage on the efficiency for degradation of NB were studied in these experiments. The optimal operating conditions covered a ZVI dosage of 15 g/L, a ZVI/GAC mass ratio of 1:2,an initial pH value of 3 and a H_2O_2 dosage of 4 mL. In this case, the NB removal efficiency reached 97.72% and the total organic carbon(TOC) removal efficiency reached 73.42% at a NB concentration of 300 mg/L. The reduction of NB by USZVI/GAC followed the pseudo-first-order kinetics model, and the pseudo-first-order rate constants were given at different initial pH values. The reaction intermediates such as AN, benzoquinonimine, p-benzoquinone, p-nitrophenol and other organic acids were detected and a probable pathway for NB degradation has been proposed.
基金Supported by Research Foundation Ability Enhancement Project for Young and Middle-aged Teachers in Guangxi Universities(2023KY2049).
文摘With the continuous deepening of rural revitalization strategy and the increasingly strict sewage discharge standards,rural domestic sewage treatment technology is facing higher challenges and requirements.The combined process of micro-electrolysis+micro-nano bubbles coupled with peroxymonosulfate was constructed in this study,and the treatment effect and application value of this technology were explored with the actual rural domestic sewage as the treatment object.The experimental results showed that under the conditions of HRT of 120 min,PMS dosage of 0.15 mmol/L,pH=7,MBs air intake of 15 ml/min,current intensity of 15 A,and Fe/C mass ratio of 1:1,the removal rates of COD,ammonia nitrogen and total phosphorus can reach 88.55%,77.18%and 74.67%,respectively.Under the condition that the pH value of sewage was not adjusted,the non-biochemical simultaneous decarbonization,denitrification and phosphorus removal of rural domestic sewage can be achieved by micro-electrolysis and micro-nano bubbles coupled with peroxymonosulfate.The concentrations of effluent COD,ammonia nitrogen and total phosphorus met the requirements of the first level standard of the Discharge Standard of Water Pollutants for Rural Domestic Sewage Treatment Facilities(DB45T2413-2021).And the comprehensive operating cost was about 1.15 yuan/m 3.
文摘针对配电系统中时有发生的并联电容器与电网阻抗之间谐振的现象,该文首先分析了传统的负载电流检测方式下并联型有源电力滤波器(parallel active power filter,PAPF)对系统谐振的抑制情况。分析表明,由于无功补偿电容器的影响,传统控制策略下的PAPF对系统谐振的抑制效果不理想,同时当检测的负载电流中包括无功补偿电容器电流时,系统还有可能出现不稳定的现象。针对这种情况该文提出了一种新的PAPF控制策略,该控制策略可以在进行谐波治理的同时有效抑制负载谐波电流或者系统谐波电压造成的并联电容器与电网阻抗之间的谐振。最后给出了实验验证结果。
基金supported by the Water Pollution Control and Management Project,China(No. 2009ZX07208)the Ministry of Science and Technology,China,for partially funding this study
文摘Treatment of oilfield produced water was investigated using an anaerobic process coupled with micro-electrolysis (ME), focusing on changes in chemical oxygen demand (COD) and biodegradability. Results showed that COD exhibited an abnormal change in the single anaerobic system in which it increased within the first 168 hr, but then decreased to 222 mg/L after 360 hr. The biological oxygen demand (five-day) (BOD5)/COD ratio of the water increased from 0.05 to 0.15. Hydrocarbons in the wastewater, such as pectin, degraded to small molecules during the hydrolytic acidification process. Comparatively, the effect of ME was also investigated. The COD underwent a slight decrease and the BOD5/COD ratio of the water improved from 0,05 to 0.17 after ME. Removal of COD was 38.3% under the idealized ME conditions (pH 6.0), using iron and active carbon (80 and 40 g/L, respectively). Coupling the anaerobic process with ME accelerated the COD removal ratio (average removal was 53.3%). Gas chromatography/mass spectrometry was used to analyze organic species conversion. This integrated system appeared to be a useful option for the treatment of water produced in oilfields.