Gypsum-based Silica Gel Humidity-controlling Composite Materials:Preparation,Characterization,and Performance
1
作者 李曦 冉茂宇 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2024年第2期337-344,共8页
Gypsum was used as substrate,and silica gel was mixed into substrate at a certain mass ratio to prepare humidity-controlling composites;moreover,the moisture absorption and desorption properties of gypsum-based compos... Gypsum was used as substrate,and silica gel was mixed into substrate at a certain mass ratio to prepare humidity-controlling composites;moreover,the moisture absorption and desorption properties of gypsum-based composites were compared with adding different silica gel particle size and proportion.The morphological characteristics,the isothermal equilibrium moisture content curve,moisture absorption and desorption rate,moisture absorption and desorption stability,and humidity-conditioning performance were tested and analyzed.The experimental results show that,compared with pure-gypsum,the surface structure of the gypsum-based composites is relatively loose,the quantity,density and aperture of the pores in the structure increase.The absorption and desorption capacity increase along with the increase of silica gel particle size and silica gel proportion.When 3 mm silica gel particle size is added with a mass ratio of 40%,the maximum equilibrium moisture content of humidity-controlling composites is 0.161 g/g at 98% relative humidity(RH),3.22 times that of pure-gypsum.The moisture absorption and desorption rates are increased,the equilibrium moisture absorption and desorption rates are 2.68 times and 1.61 times that of pure-gypsum at 58.5% RH,respectively.The gypsum-based composites have a good stability,which has better timely response to dynamic humidity changes and can effectively regulate indoor humidity under natural conditions. 展开更多
关键词 humidity controlling composite materials GYPSUM silica gel
下载PDF
Hydration Characteristics and Humidity Control Performance of Calcium Silicate Board Prepared from Mine Tailing and Diatomite 被引量:4
2
作者 战佳宇 YANG Feihua +3 位作者 LI Wanmin LIU Xiao WANG Linjun FANG Guiming 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2020年第1期147-154,共8页
The feasibility of utilizing molybdenum tailing and diatomite as siliceous materials to prepare calcium silicate board was explored.The influences of molybdenum tailing/diatomite proportion on hydration characteristic... The feasibility of utilizing molybdenum tailing and diatomite as siliceous materials to prepare calcium silicate board was explored.The influences of molybdenum tailing/diatomite proportion on hydration characteristics,thermal conductivity,water absorption,flexural strength and moisture adsorption-desorption property of calcium silicate board were investigated in detail.The experimental results reveal that molybdenum tailing is environmentally friendly to prepare building materials.The main hydration products in calcium silicate board under autoclaved condition are C-S-H with low crystallinity and tobermorite.Molybdenum tailing is favorable to the formation of tobermorite.The flexural strength and bulk density of the calcium silicate board gradually increase when the content of molybdenum tailing increases.Netlike C-S-H is formed with the increase of diatomite content during autoclaved curing process,resulting in the enhancement of moisture adsorptiondesorption performance and the reduction of thermal conductivity.The optimal content of molybdenum tailing is 20%,furthermore,the flexual strength and thermal conductivity of calcium silicate board at this content meet the Chinese standard JC/T564.1-2008. 展开更多
关键词 calcium SILICATE board MOLYBDENUM TAILING DIATOMITE HYDRATION humidity control PERFORMANCE
下载PDF
Preparation and hygrothermal performance of composite phase change material wallboard with humidity control based on expanded perlite/diatomite/paraffin 被引量:14
3
作者 YANG Hua LIU Yun +2 位作者 KONG Xiang-fei CHEN Wan-he YAO Cheng-qiang 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第10期2387-2398,共12页
Phase change material(PCM)can reduce the indoor temperature fluctuation and humidity control material can adjust relative humidity used in buildings.In this study,a kind of composite phase change material particles(CP... Phase change material(PCM)can reduce the indoor temperature fluctuation and humidity control material can adjust relative humidity used in buildings.In this study,a kind of composite phase change material particles(CPCMPs)were prepared by vacuum impregnation method with expanded perlite(EP)as supporting material and paraffin as phase change material.Thus,a PCM plate was fabricated by mould pressing method with CPCMPs and then composite phase change humidity control wallboard(CPCHCW)was prepared by spraying the diatom mud on the surface of PCM plate.The composition,thermophysical properties and microstructure were characterized using X-ray diffraction instrument(XRD),differential scanning calorimeter(DSC)and scanning electron microscope(SEM).Additionally,the hygrothermal performance of CPCHCW was characterized by temperature and humidity collaborative test.The results can be summarized as follows:(1)CPCMPs have suitable phase change parameters with melting/freezing point of 18.23°C/29.42°C and higher latent heat of 54.66 J/g/55.63 J/g;(2)the diatom mud can control the humidity of confined space with a certain volume;(3)the combination of diatom mud and PCM plate in CPCHCW can effectively adjust the indoor temperature and humidity.The above conclusions indicate the potential of CPCHCW in the application of building energy efficiency. 展开更多
关键词 thermal storage humidity control phase change material PARAFFIN expanded perlite diatom mud
下载PDF
Synthesis and analysis of new humidity-controlling composite materials 被引量:2
4
作者 Jian-li Shang Zhi-fang Zong Hao Zhang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第5期594-602,共9页
Gypsum is a traditional building material. To improve the humidity-controlling properties of gypsum, we prepared a new type of humidity-controlling composite using the sol-gel method. Methods to determine the maximum ... Gypsum is a traditional building material. To improve the humidity-controlling properties of gypsum, we prepared a new type of humidity-controlling composite using the sol-gel method. Methods to determine the maximum equilibrium moisture content and speed of adsorption/desorption were subsequently applied to analyze the performance of the samples. The appearance and structural properties of the samples were characterized by scanning electronic microscopy (SEM). The experimental results show that the humidity-controlling gel with added LiCl exhibits high moisture storage and that the equilibrium maximum moisture content is 5.652 g/g at a 75.29% relative humidity (RH). A mass ratio of LiCl/sol = 0.15 is demonstrated to be appropriate for the preparation of the new humidity-controlling composites. A coarse network with tiny pores is observed on the surface of the new humidity-controlling composites, and this pore network provides sufficient space for moisture adsorption. 展开更多
关键词 composite materials GYPSUM humidity control sol-gel processing ADSORPTION DESORPTION
下载PDF
Preparation and Absorption/Desorption Performance of Gypsum-based Humidity Controlling Materials 被引量:1
5
作者 姜洪义 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2011年第4期684-686,共3页
Absorption/desorption properties of some humidity controlling materials which contain gypsum as basic cement materials and activated Sepiolite powder as humidity controlling media were tested. The kinetics curve of mo... Absorption/desorption properties of some humidity controlling materials which contain gypsum as basic cement materials and activated Sepiolite powder as humidity controlling media were tested. The kinetics curve of moisture adsorption/desorption were drawn and humidity controlling performance in nature environment was verified. The experimental results show that moisture absorption/desorption rates are increased, and the speed is also accelerated. These materials, which can adjust environmental humidity effectively, are new ones with good humidity controlling performance. 展开更多
关键词 activated Sepiolite gypsum-composites humidity controlling performance
下载PDF
Development of Temperature-Humidity Independent Control Air-Conditioning Unit for Residential Buildings 被引量:3
6
作者 HAN Xing1,ZHANG Xu1,LIU Jin-tao2,GAO Si-yun2,KANG Yue2(1.Institute of HVAC & Gas,College of Mechanical Engineering,Tongji University,Shanghai 200092,China 2.Hisense R&D Center,Qingdao,266000,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期83-87,共5页
Cooling panels are increasingly used in domestic residential buildings.To provide medium temperature cold water for the cooling panel,and dehumidify the indoor air simultaneously,a new kind of temperature-humidity ind... Cooling panels are increasingly used in domestic residential buildings.To provide medium temperature cold water for the cooling panel,and dehumidify the indoor air simultaneously,a new kind of temperature-humidity independent control air-conditioning unit was developed for single residential house by utilizing multi-variable technology.First,the supply air temperature was studied to determine the proper supply air flow rate for the humidity control.Then,the energy consumption of different temperature-humidity independent control systems was studied.The analysis indicates that unity evaporating temperature can be used to handle the moisture load and sensible heat load in two evaporators.So the unit scheme was put forward.Two evaporators were used to produce medium temperature water and dry air separately,and electric expansion valves were used to control the refrigerant distribution between the two evaporators.Then,experimental work was carried out to investigate the influence of compressor frequency,refrigerant distribution on the dehumidification capacity,energy efficiency and refrigeration capacity.In the end,the paper concludes that both compressor frequency and refrigerant distribution can control the dehumidification capacity,but the former influences the EER more than the latter,while the latter influences the refrigeration capacity more than the former.We can find a proper running point at certain sensible and latent cooling load by adjusting both compressor frequency and electric expansion valve.The energy consumption of this kind of unit was estimated and compared with present room air conditioners,which shows that it can save about 41% cooling energy consumption. 展开更多
关键词 temperature-humidity INDEPENDENT control RESIDENTIAL BUILDINGS COLD DEhumidIFICATION experimental study
下载PDF
Efficiency Improvement of PEM Fuel Cells via Humidity Control 被引量:1
7
作者 Ahmad Haddad Louay Elsoufi +1 位作者 Marc Mannah Hasan Bazzi 《Journal of Control Science and Engineering》 2016年第1期26-35,共10页
PEM (Proton Exchange Membrane) fuel cell is a promising renewable energy source to a wide range of applications for its clean products and high power density. However, controlling its humidity is a challenging probl... PEM (Proton Exchange Membrane) fuel cell is a promising renewable energy source to a wide range of applications for its clean products and high power density. However, controlling its humidity is a challenging problem due to the interdependence of several phenomena contributing in membrane's water content. This work deals with efficiency improvement of PEM fuel cells via humidity control. An innovative strategy of control based on the model of Ref. [1] is proposed. It consists on regulating gas humidification rates according to the power demand so that to minimize power losses. The proposed control takes into consideration constraints related to humidification in order to avoid dry out or flooding of the membrane. Simulations results show that time-phasing between hydrogen and oxygen humidification rates plays an important role in minimizing power losses. The proposed control shows significant improvement in the fuel cell's efficiency up to 20%. 展开更多
关键词 PEM fuel cell mathematical modeling humidity control efficiency improvement.
下载PDF
Indoor biology pollution control based on system-based humidity priority control strategy
8
作者 刘亚昱 谢慧 石博强 《Journal of Central South University》 SCIE EI CAS 2009年第S1期17-23,共7页
Indoor biological contamination and HVAC system secondary contamination problems caused wide public concerns. Biological contamination control will be the next step to achieve better IAQ. The most efficient and safe w... Indoor biological contamination and HVAC system secondary contamination problems caused wide public concerns. Biological contamination control will be the next step to achieve better IAQ. The most efficient and safe way to control biological contamination was to limit relative humidity in HVAC system and conditioned environment in the range that is more unsuitable for microorganism to survive. In this paper,by referring to bio-clean project experiences,a system-based humidity priority control manner came into being by lowering outdoor air humidity ratio to eliminate all indoor latent load and using self recirculation units to bear indoor sensible load. Based on the whole-course residue humidity contaminant control concept,dynamic step models for coil and conditioned zone were developed to describe mass and energy conservation and transformation processes. Then,HVAC system and conditioned zone dynamic models were established on LabVIEW+Matlab platform to investigate optimized regulation types,input signatures and control logics. Decoupling between cooling and dehumidification processes can be achieved and a more simplified and stable control system can be acquired by the system-based humidity priority control strategy. Therefore,it was a promising way for controlling biological pollution in buildings in order to achieve better IAQ. 展开更多
关键词 INDOOR biological CONTAMINATION humidity PRIORITY control dynamic STEP model virtual instrument
下载PDF
COMPUTER DECOUPLE CONTROL OF TEMPERATURE AND HUMIDITY IN PREPROCESSING CHAMBER OF AIR-CONDITIONING TEST EQUIPMENT
9
作者 陆宏正 盖其祥 《Journal of China Textile University(English Edition)》 EI CAS 1989年第2期29-34,共6页
This paper deals with the application of decouple Control theory to temperature and humidi-ty control in air-conditioning system. The decouple control algorithm for bivariable systems isderived applicablly for air-con... This paper deals with the application of decouple Control theory to temperature and humidi-ty control in air-conditioning system. The decouple control algorithm for bivariable systems isderived applicablly for air-conditioning system. The algorithm is used to design a temperatureand humidity computer control system for the preprocessing chamber of air-conditioning testequipment. The results of the real-time control experiments indicate that the decouple controlalgorithm is feasible, the control quality is improved and high control precision is achieved. 展开更多
关键词 COMPUTER applications COMPUTER control DECOUPLING temperature control SYSTEM humidity control SYSTEM air conditioning control
下载PDF
Temperature and Humidity Control in Greenhouses in Desert Areas
10
作者 Shigeki Hirasawa Mai Nakatsuka +2 位作者 Kunio Masui Tsuyoshi Kawanami Katsuaki Shirai 《Agricultural Sciences》 2014年第13期1261-1268,共8页
Water consumption can be reduced by using a greenhouse for agriculture in desert areas. We analyzed the effect of control of ventilation, sprinkler water, and solar radiation?shielding on changes of temperature and hu... Water consumption can be reduced by using a greenhouse for agriculture in desert areas. We analyzed the effect of control of ventilation, sprinkler water, and solar radiation?shielding on changes of temperature and humidity in a greenhouse under various desert area conditions. We calculated the changes in temperature and humidity in a greenhouse for a whole day in four seasons, and the calculation results of water consumption with and without a greenhouse were compared. When ventilation, shielding, and sprinkler water were controlled under suitable conditions to grow orchids in a desert area, water consumption in July was only 7% of that without a greenhouse. 展开更多
关键词 Temperature control humidity Ventilation SPRINKLER Water HEAT TRANSFER GREENHOUSE DESERT
下载PDF
Design of greenhouse temperature and humidity wireless control system based on CC3200
11
作者 ZHAO Cheng-cheng DING Hai-fei +1 位作者 LIU Wen-yi KANG Xi 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2018年第2期134-139,共6页
Referring to the shortages that the process of traditional greenhouse measurement by using thermometer and hygrometer is complex,the measurement result is not accurate,and the control system operation is cumbersome,a ... Referring to the shortages that the process of traditional greenhouse measurement by using thermometer and hygrometer is complex,the measurement result is not accurate,and the control system operation is cumbersome,a greenhouse temperature and humidity(TH)control system based on CC3200 is designed.The system uses FPGA as the main controller,sends the TH signals to the wireless module CC3200 by controlling DHT22.The proposed system realizes the remote transmission of data and the automatic control of system. 展开更多
关键词 field programmable gate array(FPGA) CC3200 DHT22 temperature and humidity(TH)of greenhouse wireless control
下载PDF
Hydrogen Humidity Control in Water-hydrogen Inner Cooled Generatorand Refrigerating Hydrogen Moisture Removal Device
12
作者 Sun Shixiong Yao Zhongan(Waiqaoqiao Power Plant) 《Electricity》 1998年第3期20-22,共3页
关键词 Hydrogen humidity control in Water-hydrogen Inner Cooled Generatorand Refrigerating Hydrogen Moisture Removal Device
下载PDF
Visco-elastic-plastic model of deep underground rock affected by temperature and humidity 被引量:9
13
作者 GAO, Yanan GAO, Feng +1 位作者 ZHANG, Zhizhen ZHANG, Tao 《Mining Science and Technology》 EI CAS 2010年第2期183-187,共5页
As the depth of exploitation increases,studies on constitutive models of rock affected by temperature and humidity become very important.Based on the Nishihara model,a visco-elastic-plastic rock model was established ... As the depth of exploitation increases,studies on constitutive models of rock affected by temperature and humidity become very important.Based on the Nishihara model,a visco-elastic-plastic rock model was established by using the coefficients of thermal and humidity expansion,thermal viscosity attenuation,humid viscosity attenuation and acceleration rheology components.We used the definition of a controlled heat circle to explain the model.The results show that the behavior of rock,affected by temperature and humidity,is stable as a function of time when the stress is lower than the first yield stress σS1;the creep rate will increase due to the effect of temperature and humidity when the stress is greater than or equal to σS1;the creep rate will accelerate at an increasing rate when the stress is greater than or equal to the second yield stress σS2,which results in a failure of the roadway.The model derived in this study can completely describe visco-elastic-plastic characteristics and reflects the three stages of rock creep. 展开更多
关键词 temperature humidity CREEP controlled heat circle
下载PDF
Analysis of the Effect and Solution of Geomagnetic Room Humidity on Geomagnetic Observation 被引量:1
14
作者 Zhi Hongkui Cheng Nan +4 位作者 Geng Shufen Guo Hui Ma Zhiyong Chi Yuan Song Jianshuo 《Earthquake Research in China》 CSCD 2016年第2期264-270,共7页
It is not easy to control humidity in a geomagnetic room. If humidity is too high or the change is too fast it will lead to an abnormal change on data. The intelligent real-time humidity analysis and monitoring system... It is not easy to control humidity in a geomagnetic room. If humidity is too high or the change is too fast it will lead to an abnormal change on data. The intelligent real-time humidity analysis and monitoring system of a geomagnetic room and probe can not only monitor and display the change of humidity in the geomagnetic room and send an alarm signal when it exceeds the pre-set range, but also dehumidify intelligently. One can arbitrarily control the sensor to monitor the ambient humidity of the probe in order to ensure that the data is stable and true. The design idea and main functions of the system are introduced in the paper. 展开更多
关键词 Geomagnetic room humidity Fluxgate magnetometer humidity sensorExact humidity control Intelligent real-time monitoring
下载PDF
Occurrence and Epidemic Dynamics and Control Countermeasures of Important Sugarcane Diseases in Rainy and Humid Season
15
作者 Li Wenfeng Shan Hongli +5 位作者 Huang Yingkun Zhang Rongyue Cang Xiaoyan Yin Jiong Wang Xiaoyan Luo Zhiming 《Plant Diseases and Pests》 CAS 2017年第6期35-38,共4页
The rainy and humid season from July to September is the crucial period for elongation and jointing and yield performance of sugarcane,and also a peak occurrence and damage period of many important sugarcane diseases.... The rainy and humid season from July to September is the crucial period for elongation and jointing and yield performance of sugarcane,and also a peak occurrence and damage period of many important sugarcane diseases. In order to prevent large-area outbreak of sugarcane diseases and ensure safe growth in late stage,the occurrence dynamics of important sugarcane diseases in the rainy and humid season was analyzed and discussed from the aspects of three epidemic outbreak elements of plant diseases: host plant,pathogen and environmental condition. Moreover,the corresponding control ideas and technical countermeasures were put forward according to the epidemic characteristic of sugarcane diseases and the actual sugarcane production. 展开更多
关键词 RAINY and humid SEASON SUGARCANE DISEASES OCCURRENCE dynamics control COUNTERMEASURE Technical measures
下载PDF
A topology approach to overcome the pore size/volume trade-offs for autonomous indoor humidity control
16
作者 Zhi-Shuo Wang Xue-Wen Zhang +3 位作者 Kai Zheng Xiao-Xian Chen Dong-Dong Zhou Jie-Peng Zhang 《Science China Chemistry》 SCIE EI CAS CSCD 2024年第9期2968-2974,共7页
Autonomous indoor humidity control is gaining more and more attention but is limited by the trade-offs among pore volume,pore size and water stability of water adsorbents.We solve this problem by using a unique coordi... Autonomous indoor humidity control is gaining more and more attention but is limited by the trade-offs among pore volume,pore size and water stability of water adsorbents.We solve this problem by using a unique coordination network topology combined with hydrolytically stable M(Ⅲ)carboxylate clusters.By extending the ligand length from 9.0 to 11.2 and 13.7?,the pore volume significantly increases from 0.99 to 1.40 and 1.78 cm^(3)g^(-1),which proportionally increases the saturated water adsorption capacity.Meanwhile,the pore size slightly increases from 10.4 to 11.0 and 13.5A,which restricts the isotherm inflection pressure and hysteresis width to meet the requirement of indoor humidity control.Large single-crystals suitable for Xray diffraction studies were obtained by using Fe(Ⅲ)salts,while isostructural frameworks with sufficiently high water stabilities were synthesized by using Cr(Ⅲ)salts,which offer record working capacity of 0.90 and 1.10 g g^(-1)for indoor humidity control. 展开更多
关键词 metal-organic frameworks water adsorption indoor humidity control water stability pore engineering
原文传递
Thermodynamic performance assessment of vacuum membrane-based dehumidification and air carrying energy radiant air-conditioning system(VMD-ACERS) 被引量:2
17
作者 Liang Chun Guangcai Gong +1 位作者 Xi Fang Pei Peng 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第6期217-227,共11页
Temperature and humidity independent control(THIC)air-conditioning system is a promising technology.In this work,a novel temperature and humidity independent control(THIC)system is proposed,namely VMD-ACERS,which inte... Temperature and humidity independent control(THIC)air-conditioning system is a promising technology.In this work,a novel temperature and humidity independent control(THIC)system is proposed,namely VMD-ACERS,which integrates vacuum membrane-based dehumidification and air carrying energy radiant air-conditioning system.This work establishes a novel coefficient of performance(COP)model of VMD-ACERS.The main parameters affecting the COP of conventional fan coil unit cooling system(FCUCS)and VMD-ACERS are investigated.The performance of FCUCS and VMD-ACERS are compared,and the energy-saving potential of VMD-ACERS is proved.Results indicate that,for FCUCS,the importance ranking of parameters is basically stable.However,for VMD-ACERS,the importance ranking will be affected by FCU and refrigerant.The most important parameters of VMD-ACERS are condensation temperature and permeate side pressure.On the contrary,superheating,subcooling are relatively less important parameters.For VMD-ACERS,it is not necessary to pursue the membrane with very high selectivity,because the selectivity of membrane would also be a less important parameter when it reaches 500.The COP of VMD-ACERS is higher than that of FCUCS when the permeate side pressure is higher than 8 k Pa.The VMD-ACERS solves two technical problems about power-saving and thermal comfort of conventional THIC,and can extend the application of THIC air-conditioning system. 展开更多
关键词 Fan coil unit cooling system Temperature and humidity independent control ACERS Vacuum membrane-based dehumidification COP
下载PDF
Feasibility Assessment of Fast Numerical Simulations for Real-Time Monitoring and Control of PEM Fuel Cells
18
作者 Abbas Ghasemi Samaneh Shahgaldi Xianguo Li 《Transactions of Tianjin University》 EI CAS 2023年第1期31-45,共15页
Computational models that ensure accurate and fast responses to the variations in operating conditions,such as the cell tem-perature and relative humidity(RH),are essential monitoring tools for the real-time control o... Computational models that ensure accurate and fast responses to the variations in operating conditions,such as the cell tem-perature and relative humidity(RH),are essential monitoring tools for the real-time control of proton exchange membrane(PEM)fuel cells.To this end,fast cell-area-averaged numerical simulations are developed and verifi ed against the present experiments under various RH levels.The present simulations and measurements are found to agree well based on the cell voltage(polarization curve)and power density under variable RH conditions(RH=40%,RH=70%,and RH=100%),which verifi es the model accuracy in predicting PEM fuel cell performance.In addition,computationally feasible reduced-order models are found to deliver a fast output dataset to evaluate the charge/heat/mass transfer phenomena as well as water production and two-phase fl ow transport.Such fast and accurate evaluations of the overall fuel cell operation can be used to inform the real-time control systems that allow for the improved optimization of PEM fuel cell performance. 展开更多
关键词 fuel cell Relative humidity Real-time control Gas diff usion layer Catalyst layer
下载PDF
昆虫病原线虫防控苹果蠹蛾的影响因素 被引量:1
19
作者 张金花 田成丽 +3 位作者 姜纬明 丁岩 周佳春 李茂海 《植物检疫》 2024年第1期13-17,共5页
苹果蠹蛾(Cydia pomonella L.)是一种重要的世界性害虫,目前已在我国9个省(自治区、直辖市)发现,对我国苹果、梨等果树产业构成了严重威胁。目前,化学防治仍是防控苹果蠹蛾的主要措施,化学农药大量使用导致农药残留严重超标,影响果实品... 苹果蠹蛾(Cydia pomonella L.)是一种重要的世界性害虫,目前已在我国9个省(自治区、直辖市)发现,对我国苹果、梨等果树产业构成了严重威胁。目前,化学防治仍是防控苹果蠹蛾的主要措施,化学农药大量使用导致农药残留严重超标,影响果实品质及人类健康,因此研发新的生防制品具有重要意义。昆虫病原线虫具有主动寻找寄主害虫的能力,具有生物防治苹果蠹蛾越冬幼虫的应用潜能。本文从防控苹果蠹蛾的昆虫病原线虫高效品系以及影响其防控效果的因子(温度、湿度、紫外线等)进行了综述,以期为田间有效利用昆虫病原线虫防控苹果蠹蛾提供参考。 展开更多
关键词 苹果蠹蛾 昆虫病原线虫 生物防治 温度 湿度 紫外线
下载PDF
杭州国家版本馆恒温恒湿空调系统设计 被引量:2
20
作者 余红英 金涛 张浩 《暖通空调》 2024年第3期28-34,共7页
介绍了恒温恒湿库房空调系统的设计,提出了可在库房建成初期、运行稳定期、战时等灵活切换的3种运行模式,分析了其各自的处理过程与节能性;给出了平、战时空调系统选择方案,提出了平时回收空气源热泵机组和冷水机组的冷凝热作为再热热源... 介绍了恒温恒湿库房空调系统的设计,提出了可在库房建成初期、运行稳定期、战时等灵活切换的3种运行模式,分析了其各自的处理过程与节能性;给出了平、战时空调系统选择方案,提出了平时回收空气源热泵机组和冷水机组的冷凝热作为再热热源,战时利用新风预冷实现温湿度独立控制的方法;利用CFD模拟对室内气流组织进行了优化设计;提出了采用含湿量控制代替定露点法进行湿度控制和风机变频等控制策略。通过调试与运行,证明了各项设计措施在项目中应用的有效性。 展开更多
关键词 恒温恒湿 平战结合 库房 空调 热回收 再热 含湿量控制
下载PDF