期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Solvent extraction of La(III) with 2-ethylhexyl phosphoric acid-2-ethylhexyl ester (EHEHPA) by membrane dispersion micro-extractor 被引量:7
1
作者 侯海龙 王运东 +1 位作者 徐建鸿 陈晋南 《Journal of Rare Earths》 SCIE EI CAS CSCD 2013年第11期1114-1118,共5页
The conventional rare earth solvent extraction equipments have many problems such as long mixing time, low processing capacity, large factory area occupation, high energy consumption and so on. In order to solve the p... The conventional rare earth solvent extraction equipments have many problems such as long mixing time, low processing capacity, large factory area occupation, high energy consumption and so on. In order to solve the problems, many types of equipments were brought out. In this work, studies were carried out on the La(III) extraction process with 2-ethylhexyl phosphoric acid-2-ethylhexyl ester (EHEHPA) by membrane dispersion micro-extractor. Equilibrium studies showed that the initial aqueous pH value 4.15 with the saponification rate 40%was the optimal operation condition. The effects of membrane dispersion micro-extractor operational conditions such as dispersion mode, bulk flow rate and organic phase flow rate on the extraction efficiency were studied. The results showed that when the organic solution was the dispersed phase, the extraction efficiency was higher than that of others. Increasing bulk flow ratio could enhance the extraction efficiency greatly. When the ratio of organic phase flow rate to that of aque-ous phase was 80:80, the extraction efficiency was over 95%. The effect of stripping phase acidity on the La(III) recovery was studied. The results showed that when the stripping phase pH was 2.0, organic phase flow rate to stripping phase flow rate was 20:80;the re-covery efficiency of La(III) can reach 82%. 展开更多
关键词 lanthanum(Ill) membrane dispersion micro-extractor bulk flow rate stripping acidity rare earths
原文传递
Efficient extraction and stripping of Nd(Ⅲ),Eu(Ⅲ) and Er(Ⅲ) by membrane dispersion micro-extractors 被引量:2
2
作者 Zhuo Chen Jianhong Xu +1 位作者 Funing Sang Yundong Wang 《Journal of Rare Earths》 SCIE EI CAS CSCD 2018年第8期851-856,共6页
The extraction of low concentration rare earth elements at high phase ratio was investigated. The traditional extraction set-up, such as mixer-settler, have drawbacks of easy emulsification, difficult separation and l... The extraction of low concentration rare earth elements at high phase ratio was investigated. The traditional extraction set-up, such as mixer-settler, have drawbacks of easy emulsification, difficult separation and low efficiency if operated at the above condition. Membrane dispersion micro-extractor,owing to its well-dispersed, high surface-to-volume ratio and fast mass transfer rate, was employed in our work. Nd(Ⅲ),Eu(Ⅲ),Er(Ⅲ) were chosen to represent light, medium,heavy rare earth elements(REEs). The extraction process of REEs with 2-ethylhexyl phosphoric acid-2-ethylhexyl ester(P507) was investigated by membrane dispersion micro-extractors. Firstly, the extraction equilibrium of these three elements was explored in the stirred conical flasks, and it is indicated that the extraction efficiencies can be 0.95, 0.97 and 0.98, respectively within 40 min at phase ratio of 100:1. Then the effects of operational conditions such as the residence time, organic and aqueous flow rates on extraction efficiency were also explored in micro-extractors. The results indicate that the efficiency decreases and then increases if increasing aqueous phase flow rate, residence time and droplets' diameter are the key factors of this process. Increasing the phase ratio reduces the extraction efficiency significantly. When the REEs solution has an initial pH of 4.00, the flow rates of continuous and dispersed phase are 40 and 1.6 mL/min,respectively, and 90 mg/L Nd(Ⅲ), Eu(Ⅲ) and Er(Ⅲ) is extracted by 1 mol/L P507 at the out-let length of8 m. The extraction efficiencies are 0.978,0.983 and 0.991, respectively. Finally the stripping process was also studied with the micro-extractor. The stripping efficiencies of Nd(Ⅲ), Eu(Ⅲ) and Er(Ⅲ) can reach0.99, 0.96 and 0.91, respectively when the out-let length is 8 m and the concentration of hydrochloric acid is 1 mol/L. The developed approach offers a novel and simple strategy on the fast extraction and enrichment of low concentration rare earth elements from waste water. 展开更多
关键词 Rare earth elements Membrane dispersion micro-extractor EXTRACTION STRIPPING
原文传递
新型搅拌棒式微萃取器萃取气相色谱法分析蔬菜中毒死蜱残留量 被引量:2
3
作者 王丽丽 张晓 +2 位作者 胡宝祥 丁梨慧 陈尔芬 《农药》 CAS 北大核心 2006年第9期624-626,共3页
用自制新型搅拌棒式微萃取器吸着萃取、溶剂解吸,结合配有电子捕获检测器(ECD)的气相色谱分析蔬菜中毒死蜱残留量,以此建立一种快速、简单而准确的分析方法。对影响萃取的重要参数如萃取时间、解吸时间、解吸溶剂等进行了优化。该方法在... 用自制新型搅拌棒式微萃取器吸着萃取、溶剂解吸,结合配有电子捕获检测器(ECD)的气相色谱分析蔬菜中毒死蜱残留量,以此建立一种快速、简单而准确的分析方法。对影响萃取的重要参数如萃取时间、解吸时间、解吸溶剂等进行了优化。该方法在1 ̄500ng/L有很好的线性,线性相关系数为0.9914,最低检测限为0.3ng/L。用50ng/L的毒死蜱标准品做重现性实验,其RSD低于6.7%(n=5)。并对实际蔬菜样品进行了分析,结果令人满意。 展开更多
关键词 自制搅拌棒式微萃取器 吸着萃取 溶剂解吸 毒死蜱残留
下载PDF
毛细管微萃取结合光纤传感在线检测全血中异丙酚含量 被引量:1
4
作者 李莉 王庆振 《西北药学杂志》 CAS 2016年第1期37-40,共4页
目的建立快速测定全血中异丙酚含量原位、在线分析的新方法。方法利用毛细管微萃取器联合紫外光纤传感仪及微顺序注射-阀上实验室系统在线测定全血中异丙酚含量。结果方法的提取回收率为78.5%~81.3%,日内精密度均小于3%。异丙酚全血样... 目的建立快速测定全血中异丙酚含量原位、在线分析的新方法。方法利用毛细管微萃取器联合紫外光纤传感仪及微顺序注射-阀上实验室系统在线测定全血中异丙酚含量。结果方法的提取回收率为78.5%~81.3%,日内精密度均小于3%。异丙酚全血样品平均萃取率与传统液液萃取的平均萃取率无统计学差异(P〉0.05),但萃取时间缩短5~7min。结论该法无需离心、除蛋白等手工操作,能快速测定全血中异丙酚的含量,为全血中异丙酚含量在线检测提供良好的手段。 展开更多
关键词 异丙酚 光纤化学传感 毛细管微萃取器 微顺序注射-阀上实验室系统
下载PDF
微池热萃取法-热脱附-气相色谱质谱法测定汽车零部件及内饰材料中挥发性有机化合物 被引量:2
5
作者 王金陵 洪颖 +5 位作者 陈建松 唐晨 陶涛 曹丽华 陈文彪 丁军 《检验检疫学刊》 2017年第2期9-13,22,共6页
为了快速准确测定样品中挥发性有机化合物,使用微池热萃取法采集样品,用热脱附-气相色谱质谱法进行含量测定,并优化了采样时间和流速。该方法较传统的气袋法和采样舱法有着高通量、全自动化等优点;方法的加标回收率为89.1%-94.0%,测定... 为了快速准确测定样品中挥发性有机化合物,使用微池热萃取法采集样品,用热脱附-气相色谱质谱法进行含量测定,并优化了采样时间和流速。该方法较传统的气袋法和采样舱法有着高通量、全自动化等优点;方法的加标回收率为89.1%-94.0%,测定结果的相对标准偏差为2.13%-5.14%(n=7)。该方法适用于汽车零部件及内饰材料中挥发性有机化合物的检测。 展开更多
关键词 微池热萃取法 热脱附-气相色谱质谱法 汽车零部件及内饰材料 挥发性有机化合物
下载PDF
固相微萃取-气相色谱-质谱法测定血中痕量毒鼠强 被引量:5
6
作者 赵舰 顾万江 +1 位作者 周倩如 张学煃 《理化检验(化学分册)》 CAS CSCD 北大核心 2009年第6期729-731,共3页
血样中的毒鼠强用固相微萃取法分离。取2mL血样加水稀释至15mL,插入聚丙烯酸酯萃取纤维头30min,取出萃取头用水洗提2~3次后,在仪器的前进样口加热除去残留的水分,然后将萃取头插入仪器的进样口进行热解吸,并测定其含量。此方法的... 血样中的毒鼠强用固相微萃取法分离。取2mL血样加水稀释至15mL,插入聚丙烯酸酯萃取纤维头30min,取出萃取头用水洗提2~3次后,在仪器的前进样口加热除去残留的水分,然后将萃取头插入仪器的进样口进行热解吸,并测定其含量。此方法的检出限(3S/N)为1.1μg·L^-1。在毒鼠强质量浓度为100μg·L^-1的水平上测定了方法的相对标准偏差(n=6)为4.03%。 展开更多
关键词 固相微萃取 气相色谱-质谱法 毒鼠强 聚丙烯酸酯萃取纤维头 血样
下载PDF
旋风除尘设备智能化测量系统
7
作者 王敏 曾周末 李金泉 《电子测量技术》 2006年第2期68-69,共2页
基于微控制器实现的旋风除尘设备智能化测量系统可实现监测参数的精确传感、快速统计及数字化显示等功能;可精确、快速地测得设备在运行过程中所需的参数。文中介绍了系统的硬、软件设计及其实现方法。
关键词 旋风除尘装置 微控制器 智能化
下载PDF
浅析微电脑控制的电动摇蜜机 被引量:2
8
作者 何小飞 和绍禹 +3 位作者 李建科 周丹银 刘意秋 郑永春 《蜜蜂杂志》 2014年第9期5-6,共2页
蜂农在转地饲养过程中,电源是主要问题。在实验推广中了解到部分蜂农已经使用上小型太阳能发电系统,解决了蜂场的电源问题。为此,就已有研究成果(一种适用于蜜蜂转地饲养的电动摇蜜机及配套多功能电气控制装置)进行改进分析研究,设计了... 蜂农在转地饲养过程中,电源是主要问题。在实验推广中了解到部分蜂农已经使用上小型太阳能发电系统,解决了蜂场的电源问题。为此,就已有研究成果(一种适用于蜜蜂转地饲养的电动摇蜜机及配套多功能电气控制装置)进行改进分析研究,设计了用一种微电脑控制的电动摇蜜机,以适应具备直流12 V电源的蜂场情况,节省了蜂农不必要的开支,同时也降低摇蜜机的生产成本。经过实地考察,得到了广大蜂农的支持及专家的认可,从而验证了该研究的可行性。 展开更多
关键词 转地饲养 摇蜜机 微电脑控制
下载PDF
毛细管微萃取结合微顺序注射在线检测全血中异丙酚含量 被引量:2
9
作者 王庆振 李莉 《中国现代应用药学》 CAS CSCD 2016年第1期16-19,共4页
目的 建立一种快速测定全血中异丙酚含量的原位、在线分析的新方法。方法 利用毛细管微萃取器联合紫外光纤传感仪及微顺序注射-阀上实验室系统在线测定全血中异丙酚含量。结果 该方法的加样回收率为95.8%~103.6%;低、中、高3个浓度(10... 目的 建立一种快速测定全血中异丙酚含量的原位、在线分析的新方法。方法 利用毛细管微萃取器联合紫外光纤传感仪及微顺序注射-阀上实验室系统在线测定全血中异丙酚含量。结果 该方法的加样回收率为95.8%~103.6%;低、中、高3个浓度(100,150,200μg·m L^-1)的日内精密度RSD分别为7.2%,8.2%和2.6%,日间精密度RSD分别为10.0%,6.1%和7.7%。与传统液液萃取方法相比,该方法异丙酚平均萃取率提高3.5%,萃取时间缩短5~7 min。结论 该方法样品前处理无需离心、除蛋白等操作,能快速测定全血中异丙酚的含量,为全血中异丙酚含量原位、在线检测提供了良好的手段。 展开更多
关键词 异丙酚 光纤化学传感 毛细管微萃取器 微顺序注射-阀上实验室系统
原文传递
固相微萃取和同时蒸馏萃取法分析臭椿叶挥发性组分的初步研究 被引量:5
10
作者 李大鹏 曹逸霞 +4 位作者 陈乃中 马菲 于艳雪 李志红 陈洪俊 《植物检疫》 北大核心 2013年第1期1-6,共6页
本实验采用同时蒸馏萃取法(simultaneous distillation extraction,SDE)和固相微萃取法(solidphase micro-extraction,SPME)提取臭椿(Ailanthus altissima)叶片的挥发性物质,经气相色谱/质谱联用仪分析,共检测出8类42种挥发性化合物,挥... 本实验采用同时蒸馏萃取法(simultaneous distillation extraction,SDE)和固相微萃取法(solidphase micro-extraction,SPME)提取臭椿(Ailanthus altissima)叶片的挥发性物质,经气相色谱/质谱联用仪分析,共检测出8类42种挥发性化合物,挥发物中烯类最多,22种,其次是醇类6种、烷烃类6种,另外酮类、酯类、芳香烃类、酸类和酚类分别检测出2、2、2、1、1种。采用SPME法提取的挥发性化合物中醇类、酮类和烷烃类的种类多于SDE法,烯类少于SDE法。酚类物质仅在SPME法检出,而芳香烃类仅在SDE法检出。检测到的挥发物组分中有对昆虫起驱避作用的成分。 展开更多
关键词 臭椿 挥发性物质 同时蒸馏萃取 固相微萃取 气相色谱 质谱
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部