A novel technique of Moveable Reduction Bed Hydride Generator(MRBHG)was applied tohe hydride generation or cold vapor generation of As,Se,Ge,and Hg existing In TraditionalChinese Medicinal Material(TCM).The si...A novel technique of Moveable Reduction Bed Hydride Generator(MRBHG)was applied tohe hydride generation or cold vapor generation of As,Se,Ge,and Hg existing In TraditionalChinese Medicinal Material(TCM).The simultaneous determination of the multi-elements wasperformed with ICP-MS.A solid reduction system involving the use of potassiumtetraborohydride and tartaric acid was applied to generating metal hydride or cold vaporefficiently.The factors affecting the metal cold vapor generation were studied.The mainadvantage of the technique is that only a 4μL volume of sample was required for the cold vapor展开更多
A direct analysis method combining an iminodiacetate extraction disk (IED) with graphite furnace atomic absorption spectrometry was developed for the determination of Co, Ni, Cu, Cd, Sn, Pb, and Bi at sub-ppb levels i...A direct analysis method combining an iminodiacetate extraction disk (IED) with graphite furnace atomic absorption spectrometry was developed for the determination of Co, Ni, Cu, Cd, Sn, Pb, and Bi at sub-ppb levels in water. A 100 mL water sample was adjusted to pH 5.6 with nitric acid and a 1 mol?L–1 ammonium acetate solution, and then passed through an IED (diameter, 47 mm;effective filtering diameter, 35 mm) at a flow rate of 80 - 100 mL?min–1 to preconcentrate seven analytes. The IED was dried at 100?C for 20 min in an electric oven, and 110 - 145 small disks, each 2 mm in diameter, were punched out from the IED. A small disk was introduced into the graphite furnace and atomized according to a heating program. For Cd, Sn, Pb, and Bi measurements, Pd was used as a chemical modifier to enhance the absorbances. Calibration was performed using aqueous standard solutions. The detection limits, corresponding to three times the standard deviation (n = 5) of the blank values, were 0.092 μg·L–1 for Co, 0.12 μg·L–1 for Ni, 0.40 μg·L–1 for Cu, 0.077 μg·L–1 for Cd, 0.92 μg·L–1 for Sn, 0.61 μg·L–1 for Pb, and 0.80 μg·L–1 for Bi with an enrichment factor of 140 using a 100-mL water sample. A spike test for the seven analytes in tap water, rainwater, river water, and mineral drinking water showed quantitative recoveries (93% - 108%).展开更多
将超声搅拌悬浮液进样技术应用于火焰原子吸收光谱法,成功地测定了茶叶中铜、铁、锌、铅、镉的含量,此法快速、简单、准确.样品在(80±2)℃烘干4 h后,研磨过160目筛,然后加入5 mL 0.15%琼脂悬浮液,用超声搅拌混匀后直接上机测定....将超声搅拌悬浮液进样技术应用于火焰原子吸收光谱法,成功地测定了茶叶中铜、铁、锌、铅、镉的含量,此法快速、简单、准确.样品在(80±2)℃烘干4 h后,研磨过160目筛,然后加入5 mL 0.15%琼脂悬浮液,用超声搅拌混匀后直接上机测定.测定结果与传统湿法一致,t检验表明两者无显著性差异,相对误差<±0.96%.展开更多
文摘A novel technique of Moveable Reduction Bed Hydride Generator(MRBHG)was applied tohe hydride generation or cold vapor generation of As,Se,Ge,and Hg existing In TraditionalChinese Medicinal Material(TCM).The simultaneous determination of the multi-elements wasperformed with ICP-MS.A solid reduction system involving the use of potassiumtetraborohydride and tartaric acid was applied to generating metal hydride or cold vaporefficiently.The factors affecting the metal cold vapor generation were studied.The mainadvantage of the technique is that only a 4μL volume of sample was required for the cold vapor
文摘A direct analysis method combining an iminodiacetate extraction disk (IED) with graphite furnace atomic absorption spectrometry was developed for the determination of Co, Ni, Cu, Cd, Sn, Pb, and Bi at sub-ppb levels in water. A 100 mL water sample was adjusted to pH 5.6 with nitric acid and a 1 mol?L–1 ammonium acetate solution, and then passed through an IED (diameter, 47 mm;effective filtering diameter, 35 mm) at a flow rate of 80 - 100 mL?min–1 to preconcentrate seven analytes. The IED was dried at 100?C for 20 min in an electric oven, and 110 - 145 small disks, each 2 mm in diameter, were punched out from the IED. A small disk was introduced into the graphite furnace and atomized according to a heating program. For Cd, Sn, Pb, and Bi measurements, Pd was used as a chemical modifier to enhance the absorbances. Calibration was performed using aqueous standard solutions. The detection limits, corresponding to three times the standard deviation (n = 5) of the blank values, were 0.092 μg·L–1 for Co, 0.12 μg·L–1 for Ni, 0.40 μg·L–1 for Cu, 0.077 μg·L–1 for Cd, 0.92 μg·L–1 for Sn, 0.61 μg·L–1 for Pb, and 0.80 μg·L–1 for Bi with an enrichment factor of 140 using a 100-mL water sample. A spike test for the seven analytes in tap water, rainwater, river water, and mineral drinking water showed quantitative recoveries (93% - 108%).
文摘将超声搅拌悬浮液进样技术应用于火焰原子吸收光谱法,成功地测定了茶叶中铜、铁、锌、铅、镉的含量,此法快速、简单、准确.样品在(80±2)℃烘干4 h后,研磨过160目筛,然后加入5 mL 0.15%琼脂悬浮液,用超声搅拌混匀后直接上机测定.测定结果与传统湿法一致,t检验表明两者无显著性差异,相对误差<±0.96%.